V200 POSITIONER. Datasheet

Similar documents
V200 POSITIONER. Datasheet

V200 POSITIONER r14 1

V200 POSITIONER r0 1

DeZURIK P200-P204 POSITIONERS. With Feedback and External Options

V200 POSITIONER

V100 Positioner CONTENTS

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

V200 Series Positioners

V200 Series Positioners

Features. Flexibility

V200 Series Positioners

PMV P36C AND P41C POSITIONERS ACTUATORS

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Valve Positioners Series 760P/E Valve Positioners

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

The EP5 electropneumatic positioner is

Valve Positioners Series 760P/E Valve Positioners

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Control Valves Positioner

Control Valves Positioner

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

YT-1200 Series VERSION 1.02

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV1 and AV2 Characterizable pneumatic and electro-pneumatic positioners

Trouble Shooting Guide for V100 Positioner

RTX1000 SERIES ELECTRO-PNEUMATIC POSITIONER

brands you trust. CRANE - Automation Actuators and Instrumentation

Pneumatic Positioner PNY Series USER'S MANUAL. Max-Air Technology. Version 1.0

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual


Fisher 585C Series Piston Actuators

KIT INSTALLATION INSTRUCTION

FasTrak High Capacity Smart Positioner

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

TZIM. Electropneumatic Analog Positioner 10/ EN

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

V200 POSITIONER. V200 FEEDBACK OPTION r14

CONTROLS INC. Position Indicators. Valve Positioners

CENTAC Inlet and Bypass Valve Positioners

Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX P/P Ver. 0.1 Dated: MAY / 2009 REV 01: SEP/2010 Page 1 of 16

Fig Single-Acting Rotary Smart Positioner

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

CONTROL VALVE ACCESSORIES CVA : 0611 ELECTRO PNEUMATIC / PNEUMATIC POSITIONER POSITION TRANSMITTER SIL

Spring Cylinder Rotary Actuator

Series AV1 / 2 / 4 Characterizable pneumatic positioners

Series AV1 / 2 / 3 / 4 Characterizable pneumatic positioners

PP Series Pneumatic Actuators

Type 3660 and 3661 Positioners

Actuators & Positioners Characterizable Pneumatic Positioners Series AV1/2/3

Quarter Master Chief Series 92 Actuator

POSITIONERS and Controls for Complete Valve Automation

Product Specification

Electro-Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX E/P Ver. 0.1 Dated: dd / mm / yy Page 1 of 18

AS-I

Quarter Master Series 94 Actuator

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

Type 4746 Electric or Pneumatic Limit Switch

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Masoneilan. Model 8007 and 8008 Electropneumatic Transducers. New Nozzle Design Minimises Effect of Vibration. Specification Data BS 6500 E 06/03

Fisher i2p 100 Electro Pneumatic Transducer

Fisher 546 Electro Pneumatic Transducer

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

fact sheet Masoneilan * 8012/8013 Series Electro-pneumatic Valve Positioners GE Oil & Gas Excellent Dynamic Response and Positioning Accuracy

PNEUMATIC ACTUATORS. Linear acting

MTC Series. Double Acting and Spring Return Actuator and Accessories. MasterTorq. Pneumatic Actuators. Atex Class 2

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

Type 730 Diaphragm Valves

PP Series Pneumatic Actuators

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

ABB Automation. Characterizable Pneumatic Positioners Series AV1/2/3/4. Series AV1/2/3/4 Pneumatic Positioners

350 Series Electrohydraulic Actuators

Manual. P3 Modular Linear Positioner

Valtek XL Series High Performance Positioner. for Control Valves

COMPLETE LISTING OF OPTIONS. Toggles, Lights

Mounting: The following instructions apply to rotary actuators only. Linear applications require special mounting and coupling (consult factory).

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Electropneumatic positioner APIS

Pneumatic rotary drive

Linear Valve Electric Actuator

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

RDN4 - RDN8 Differential pressure switch

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

Biffi Morin S series actuators

Fisher 3710 and 3720 Valve Positioners and 3722 Electro-Pneumatic Converter

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Series 800 SRP and SReP

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Transcription:

atasheet 1

CONTENTS 1 INTOUCTION... 3 1.1 Principle of Operation... 3 1.2 Product Identification... 3 1.3 Air quality recommendations... 4 1.4 Safety Instructions... 4 2 INSTALLATION... 5 2.1 Connections... 5 2.2 General mounting instructions... 6 2.2.1 otary actuators... 6 2.2.2 Linear actuators... 6 2.3 Installation instructions for rotary actuators... 7 2.3.1 ouble acting... 7 2.3.2 Single acting... 7 2.4 Installation instructions for linear actuators... 8 2.4.1 ouble acting... 8 2.4.2 Single acting... 8 2.5 Cam... 9 2.5.1 Adjustments... 9 2.5.2 Cam specifications... 9 3 SPECIFICATIONS... 10 3.1 Specifications V200... 10 3.2 Ordering Codes... 11 4 IMENSION... 12 4.1 V200 P/E std... 12 2 92214r0

1 INTOUCTION 1.1 Principle of Operation The V200 incorporates the force balance principal of operation. The desired value, in the form of pressure, affects the membrane(1) with the force that is created and transferred to the balance arm(2). The opposing force, which represents the actual control value, is provided by the feedback spring(5) and creating force in the opposite direction on the balance arm(2). The feedback spring, resting on the feedback arm(3), is positioned by the shape and response of the cam. The cam(4) is connected to the cylinder s (actuator) piston rod via the drive. The pilot valve(6) is connected to the balance arm and follows the balance arm s movement. The system is stable when the gold plated spool(7) is in the neutral position and the forces that affect the balance arm is in equilibrium. As soon as a signal change occurs or a change in the position of the valve/actuator package occurs, the force balance is also changed and the spool responds. Air immediately begins to flow into the part of the actuator (C+ or C-) which allows the feedback mechanism to return the spool to the neutral position. The system is self-stabilizing and searches for a steady state position. 7 1 2 3 5 6 1.2 Product identification 4 The V200 identification tags, Serial number tag(1), product model tag(2) and feedback option tags(3), are placed as shown. The product model tag contains information on control signal, maximum working pressure and temperature ranges. Other information can be shown depending on the model. 92214r0 3

1.3 Air quality recommendations Poor air quality is one of the main causes of premature functional problems with pneumatic and electro pneumatic equipment. The pilot valve and IP-converter are precision instruments, and are therefore the most sensitive parts of the positioner. a) Water in the supply air is a natural occurrence. This happens when air is compressed. The compression heats the air and the natural degree of water in the air can remain as moisture. When the air cools in pipes etc. the moisture condenses and becomes liquid water. Large quantities can build and sometimes flood small water separators. This excess water will eventually reach the control valve and positioner. This can cause corrosion damage to the IP converter, causing the unit to malfunction. We strongly recommend the use of water separators with adequate capacity. Coalesing filters from a reputable manufacturer is an inexpensive way to help prevent unit malfunctions or failures, and add life to the product. These filters remove particles and moisture from air lines. b) Oil in the supply air usually is from the main compressor. Oil can clog the small nozzles and disturb the flapper in the IP-converter. It can also cause the gold plated spool to drag within the pilot valve. The result is poor control or in the worst case, failure. c) Particles in the air usually occur because of corrosion. irt and particles can block the small nozzles of the IP-converter. They can also cause the pilot valve to malfunction. The unit may completely fail. To ensure normal operational safety with VAC positioner products, we recommend that a water separator and a <80 micrometer filter are mounted as close to the product as possible. If large amounts of oil are present an oil separator should be installed as well. To further increase operational safety, we recommend that the working air is clean, dry and free of moisture, water, oil, particles and other contaminants, in accordance with the standard ANSI/ISA 7.0.01 1996 1.4 Safety Instructions CAUTION: Beware of moving parts when positioner is operated! CAUTION: Beware of parts with live voltage! A voltage, which is normally not dangerous, is supplied to the positioner. Avoid touching live parts and bare wires as well as short circuiting live parts and the housing. CAUTION: o not dismantle a pressurized positioner! ismantling a pressurized positioner will result in uncontrolled pressure release. Always isolate the relevant part of the pipeline. elease the pressure from the positioner and the piping. Failure to do this may result in damage or personal injury. CAUTION: o not exceed the positioner performance limitations! Exceeding the limitations marked on the positioner may cause damage to the positioner, actuator and valve. amage or personal injury may result. 4 92214r0

2. INSTALLATION 2.1 Connections S Supply air V200P: max. 10 bar / 1 MPa / 145 psi V200E: 1,5-10 bar / 0,15-1 MPA / 23-145 psi I Input, pressure signal V200P: 0,2 1 bar / 20-100 kpa / 3-15 psi V200E: Plugged I E Input, current signal V200E: 4-20 ma (i max 250 ohm) V200P: Plugged C+ - Actuator connection + stroke C- - Actuator connection - stroke OUT - All air from the actuator, IP and positioner is vented through this port. Standard equipped with a bug screen/silencer Air connections for male 1/4 NPT or G 1/4. Connection Back III.eps Gauge connections for male 1/8 NPT or G 1/8. Cable entry for male 1/2 NPT or M20 cable fittings. G threads are indicated by an engraved G on the air connection side of the positioner. Gauge ports I, C+, C- and S are factory plugged. emove plugs and replace with gauges. The IP connection must be plugged in V200E. The IE entrys should be plugged in V200P 92214r0 5

2.2 General mounting instructions. The V200 has the ISO F05 hole pattern(1) and 2¼ x 2¼ hole pattern(2). depth depth Hole pattern II.eps 2.2.1 otary actuator The VAC V200 has a very stable and properly sized drive shaft bearing. However, the positioner drive(a) should be aligned properly to the rotary actuator spindle(b). A relatively small error combined with a rigid coupling can create very powerful radial forces, which can overload and cause premature wear. 2.2.2 Linear actuator When mounting to linear actuators, the positioner should be attached in such a way that its drive is in the center (mid stroke) of the actuator s stroke. Proper installation and alignment will minimize linearity error. 6 92214r0

V200 POSITIONE 2.3 Installation instructions for rotary actuators 2.3.1 ouble acting irect (CCW) 90 10 SPLIT ANGE 5 10 Signal opens everse (CW) 10 B 10 SPLIT ANGE 90 5 Signal closes 2.3.2 Single acting Spring opens everse (CW) Spring closes irect (CCW) 10 B 10 SPLIT ANGE 90 5 90 SPLIT ANGE 5 10 10 Signal closes Signal opens Spring opens irect (CCW) Spring closes everse (CW) 90 SPLIT ANGE 5 10 10 B 10 SPLIT ANGE 90 5 10 Signal opens Signal closes 92214r0 7

2.4 Installation instructions for linear actuators 2.4.1 ouble acting irect (CCW) Signal closes Signal opens everse (CW) Signal opens Signal closes 2.4.2 Single acting Spring opens irect (CCW) Spring closes Spring opens Signal closes everse (CW) Signal opens Spring closes 8 92214r0 Signal opens Signal closes

V200 POSITIONE 2.5 Cam The V200 is standard shipped with the C1-cam, factory set for 90 ±1, direct (CCW) turning. 2.5.1 Adjustments emove the front cover and indicator. (see page 15) 10 9 1. Loosen the locking screw(2) and the cam nut(1). 5 SPLIT ANGE 90 10 2. Stroke the valve/actuator to the stop/end position at input. 3. Turn the cam(3) so that the index mark(5) for the selected curve aligns with the ball bearing(4). A small gap between the roller and the cam tip is desirable. 4. Tighten the cam nut by hand(1). Check that the locking screw(2) is still loose. (if not, loosen the locking screw slightly and tighten the nut again). 5. Tighten the locking screw(2). o not tighten cam nut with screw(2) down. 2.5.2 Cam specifications C1 Index mark / Starting point of rotation * 5. 90 Linear 0-10 CCW 6. 180 Linear 0-10 CW 6. 90 Linear 0-5 CW split range 7. 90 Linear 50-10 CW split range 8. 90 Linear 0-10 CW 9. 180 Linear 0-10 CCW 10. 90 Linear 0-5 CCW split range 11. 90 Linear 50-10 CCW split range *Increasing signal rotation. Most valves rotate CW to close / CCW to open 5 SPLIT ANGE 90 10 10 B 10 90 SPLIT ANGE 5 When field reversing action of positioner tubing must be reversed as well (see page 7 and 8) 10 92214r0 9

3. SPECIFICATIONS 3.1 Specifications V200 Input Signal: Supply Pressure: Linearity error: Hysteresis: epeatability: Pneumatic V200P 0,2-1 bar / 3-15 psi <10 bar / <1MPa / <145 psi <0.7% f.s <0.4% f.s <0.3% f.s Electropneumatic V200E (WS 122 I/P. V010) Electropneumatic Intrinsically Safe V200IS (WS 122 I/P. FV010) 4-20mA (Max.:i 250 Ohm) 4-20mA (Max.:i 250 Ohm) 1,5-10bar / 0,15-1MPa / 21,8-145 psi 1,5-10bar / 0,15-1MPa / 21,8-145 psi <1. f.s <1. f.s <0.6% f.s <0.6% f.s <0.5% f.s <0.5% f.s Temperature range: -40 bis +85 C -40 bis +185 F -40 bis +85 C -40 bis +185 F Values with standard pilot valve, LB installed. Pressure gain: @ 6bar / 600kPa / 87 psi 240:1 240:1 240:1 Bleed ate: Nm 3 /h (Nl/min) Nm 3 /h (Nl/min) Nm 3 /h (Nl/min) @ 6bar / 600kPa / 87 psi 0,34 (5,6) 0,42 (7,0) 0,42 (7,0) Air elivery Nm 3 /h (Nl/min) Nm 3 /h (Nl/min) Nm 3 /h (Nl/min) @ 6bar / 600kPa / 87 psi 48 (800) 48 (800) 48 (800) -40 bis +85 C * -40 bis +185 F* *Temp.range depending on certification Air connections: Gauges: Cable entry: 1/4 G (optional NPT threads) 1/4 G (optional NPT threads) 1/4 G (optional NPT threads) 1/8 G (optional NPT threads) 1/8 G (optional NPT threads) 1/8 G (optional NPT threads) M20x1,5 (optional 1/2 NPT) M20x1,5 (optional 1/2 NPT) M20x1,5 (optional 1/2 NPT) Ingress & corrosion protection: Standard coating: NEMA 4X and IP66 Polyester NEMA 4X and IP66 Polyester NEMA 4X and IP66 Polyester Weight: Weight with gauges: 1,45kg (3,2 lbs) 1,7kg (3,8 lbs) 1,7kg (3,8 lbs) 1,54kg (3,4 lbs) 1,9kg (4,2 lbs) 1,9kg (4,2 lbs) Valve types. (SG/LB valve is installed as standard) SG/LB SHG (3) SHGSHF (4) Pressure Gain: Pressure Gain: Acc. to ISA S75.13 Air elivery: @ 2bar / 0,2MPa / 29 psi Poutput / Pinput 80 367 370 @ 6bar / 0,6MPa / 87 psi Poutput / Pinput 240 1100 1100 @ 10bar / 1,0MPa / 145 psi Poutput / Pinput 400 1833 1830 Any %Poutput / %Pinput 16 79 72 @ 2bar / 0,2MPa / 29 psi Nm 3 /h/(nl/min) 16,2 / (270) 17,82 / (297) 28,2 / (470) @ 6bar / 0,6MPa / 87 psi Nm 3 /h/(nl/min) 48 / (800) 53,4 / (890) 84 / (1400) @ 10bar / 1,0MPa / 145 psi Nm 3 /h/(nl/min) 79,8 / (1330) 89,2 / (1486) 139,8 / (2330) Bleed ate: Options: @ 2bar / 0,2MPa / 29 psi Nm 3 /h/(nl/min) 0,2 / (3,4) 0,47 / (7,9) 0,74 / (12,3) @ 6bar / 0,6MPa / 87 psi Nm 3 /h/(nl/min) 0,34 / (5,6) 1,41 / (23,5) 2,21 / (36,8) @10bar / 1,0MPa / 145 psi Nm 3 /h/(nl/min) 0,6 / (10,0) 2,35 / (39,1) 3,68 / (61,3) Feedback Spring for 0,4-2 bar / 40-200kPa / 6-30 psi input signal. Gauges. Stability kit, feedback modules. 10 92214r0

.2 Ordering Codes Pneumatic Electropneumatic Explosion Proof Intrinsically Safe Fail Freeze V200P V200E V200EX V200IS V200FF Spindle 1 Namur (standard) For additional spindle options, please contact VAC or visit our website at Front Cover 90 degree rotation 90 60 degree rotation 60 45 degree rotation 45 30 degree rotation 30 Blank scale 00 Indicator Arrow Standard Beacon/aised (Black/Yellow) Optional Beacon/aised (ed/green) A B BG Cam (standard) 90 C1 (standard) For additional cam options, please contact VAC or visit our website at Spool Valve Options (shipped with standard spool) Standard (Low Bleed) SG/LB Shipped as Standard Super High Gain SHG (3) Super High Gain Super High Flow SHGSHF (4) Options Extra High Temp (Pneumatic only) (-40 to +163 C / -40 to +325 F) EHT Low Temp (Pneumatic only) (-50 to +85 C / -58 to +185 F) LT 0/10 Volt I/P (V200E only) 0/10V Gas Approved GA ATEX ATEX Tufram Coating (V200 P and E) TUF Nickel Coating (V200 P and E) NIC 40-200kPa / 6-30 psi Spring 6-30 Feedback Options FB 2 SPT Mechanical Switches M 2 SPT eed Switches 2 SPT Inductive Switches N 4-20 ma Transmitter ma Mech Switches w/transmitter MmA eed Switches w/transmitter ma 1 K potentiometer 1K 10 K potentiometer 10K Example: V200E-1-90-B-C1 Electropneumatic with namur spindle, 90 degree cover, raised indicator, 90 degree cam Example: FB-MmA Mechanical switches with 4/20 ma transmitter. 92214r0 11

4. IMENSIONS 4.1 V200P/E std Gauges 1/8" NPT(4x) (optional) Hex size 10 13/32" 68 2 11/16" 6 13/16" 173,4 1 25/32" 45 1 25/32" 45 1 5/8" 41 2 13/32" 61 4 3/4" 121 3/16" 5 208 8 3/16" 12,5 1/2" 25/32" 20 31/32" 25 Air connections 1/4" NPT (5x) 39,5 1 9/16" 22,5 7/8" 40,5 1 19/32" Conduit Entry 1/2" NPT (2x) ome Indicator(optional) Conduit Entry 1/2" NPT (2x) 47,5 1 7/8" 1 3/8" 35 3/16" 5 2 1/16" 52,5 1 3/16" 30 3 27/32" 97,5 2 15/32" 62,5 5/8" 15,5 1 7/8" 47,5 133 5 1/4" 57 2 1/4" 25 31/32" 56 2 7/32" 1,5 1/16" 75 2 31/32" ISO F05 (4x) M6-1/2"[12mm] Westlock (4x) UNC 5/16" - 1/2"[12mm 75 2 15/16" Sqr 75,6 2 31/32" Westlock Sqr. 57,2 2 1/4" ISOF05 Sqr 35,4 1 13/32" 108 4 1/4" 5" 127 1 31/32" 50 2 11/32" 59,7 imensional rawing VAC Positioner V200 P and E 12 92214r0

esigned and manufactured in Sweden by: