HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Similar documents
CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

RKB. Heat recovery units from 100 to m 3 /h >50 %

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

technical catalogue tetris KW Chiller and heat pumps air/water

RECU-NOVO. heat recovery unit

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

UMXCA/UMXCBA ECVA/ECVBA

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Accessories. Series REC

AQVSL/AQVSH STAR 85 to 140

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

AQWL/AQWH/AQWR 1404 to 2406

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

Air Cooled Packaged Units

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

WQL/WQH/WQRC 524 to 1204

D M S 760 C01 A A 1 1

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

Prepared By : Checked By : Approved By : Page 1 out of 6

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Reversible air-to-water scroll heat pumps

AZURA. Air/water multifunctional chiller&heat pump, kw

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air-Cooled Liquid Chiller with integrated hydraulic module

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CXAM. Options. Accessories

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

AHN 064 to 304 EHN/CHN 064 to 304

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Epsilon Echos DK kw

NEW Slimpak EC Box Fan (SLPT EC)

NCF fans 50 Hz. Protection class IP 55

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

Heat recovery units type GTDHR

Ducted Split System Air Conditioners

Multi-pipe units with scroll compressors

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Rotary heat exchangers

... RTU Technical Manual. Packaged Air Conditioning Unit...

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

Y-Flow TCHEY-THHEY

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

ROOF FAN ROOFMASTER STEC

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Sentinel D-Box Twin Fan

TRI-CAPACITY PACKAGE UNIT

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw

BRIZA 22 HYBRID HEATING & COOLING

Everest XV. ErP. High Efficiency HRV Fan Unit READY

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

OMICRON V EVO. Multifunctional unit

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

Cubic unit cooler. SKB semi-industrial range

DIRECT-AIR ILB / ILT Series Rectangular duct fans

ENR Incorporating

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU)

Heat Exchangers. Evaporator Catalogue

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

HWT 1402/9603. free cooling

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

Ducted Split System Air Conditioners

Air Cooled Packaged Units Technical Data

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Transcription:

1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain panels (42mm. thick) of sandwich type with special sealing gaskets; exterior finish RAL 92; thermal acoustic mineral wool insulation class and high density. Filtering sections of F7 efficiency class with soft pocket on the outside air circuit and M5 on exhaust air circuit, removable from the side. Fan sections with single inlet rear curved blades plug-fans directly coupled to EC Brushless electronic motors. Dynamic air-to-air type recovery system consisting of high efficiency enthalpy rotor, Eurovent certificate, produced in aluminium alloy with hygroscopic treatment, complete cleaning sector and drive belt engine designed for free-cooling management in on/off mode. Second section of dynamic heat recovery obtained with cooling reversible R41A system, essentially consisting of: hermetic compressor/s, twin rotary brush less EC complete with dedicated inverter, evaporator/condenser with finned tubes in Cu/Al, electronic expansion valve, reverse cycle valve, high pressure gauge, high and low pressure transducers, separators and fluid receivers. Complete control panel with display on board machine and microprocessor for temperature control at inlet flow fixed point, based on the operation logics designed to maximize energy savings and environmental comfort, thanks to the modulation of cooling power and air flow guaranteed by the inverter technology. The unit is designed for RS485 connection to supervision systems based on Modbus RTU protocol. R41A HP ROTARY EC FANS EC COMP PLUG&PLAY

FERRARO GROUP Lmf Clima 216 11 Accessories Pre and/or post-heating electrical coil SKE External water cooling/heating section CCS 3-way valve with actuator V33 3 damper mixing chamber MS3 Additional compact filter M6 class, on fresh air side FC6 Bag filter F7 class, on return air side FT7 Bag filter F8 class, on fresh air side (to be combined with FC6) FT8 Filters differential pressure gauge PSTD Differential pressure transducer DPS CO2 air quality sensor AQS Room hygrostat HAS Ductable hygrostat HCS External damper SKR On/off actuator with spring return for external damper SSE External hood with network CFA Flexible connection GAT Roof for outdoor installation TPR ENTHALPIC HIGH-EFFICIENCY HEAT RECOVERY UNIT BUILT-IN ELECTRONIC CONTROL WITH GRAPHICAL DISPLAY INTEGRATED REVERSIBLE HEAT-PUMP SYSTEM >8 % EFFICIENCY ERP 215 INSIDE FULL OUTSIDE

12 Lmf Clima 216 FERRARO GROUP Models HPR 14 2 26 5 92 144 25 Airflow m³/h 1 21 29 57 95 135 19 Rated static prevalence Pa 25 25 25 25 25 25 25 Maximum static pressure Pa 42 392 53 495 815 73 725 1 m sound pressure level at the outside of the machine db(a) 43 47 43 47 51 5 53 Total max current absorption A 12,2 19,2 28,8 32,3 5,1 69,9 1,3 Power supply V-Ph-Hz -3+N-5-3-5 Efficiency (1) % 8,6 8,4 8,6 8,6 8,6 8,7 76, Recovered cooling capacity (1) kw 3,6 5,35 7,4 14,6 24,3 34,5 45,9 Compressor cooling capacity (1) kw 5,6 8,86 12,2 24,1 4,1 57, 8,2 Total cooling capacity (1) kw 8,12 14,2 19,6 38,7 64,4 91,5 126 Available cooling capacity (1) kw 2,45 4,28 5,92 11,6 19,4 27,5 38,8 EER (1) 4,8 4,3 4,1 4,8 4,9 4,7 4,1 Supply temperature (1) C 2, 2, 2, 2, 2, 2, 2, Efficiency (2) % 8,2 8, 8,1 8,2 8,1 8,2 75,1 Recovered heating capacity (2) kw 14,9 26, 35,9 7,6 118, 167 22 Compressor heating capacity (2) kw 5,2 8,85 12,2 23,8 4,1 56,5 9,4 Total heating capacity (2) kw 19,9 34,9 48,1 94,4 158 224 31 Available heating capacity (2) kw 2,45 4,28 5,92 11,6 19,4 27,5 38,8 COP (2) 3,58 3,56 3,5 3,64 3,58 3,6 3,62 Supply temperature (2) C 28, 28, 28, 28, 28, 28, 28, FANS Max current consumption A 2 x 2,17 2 x 5,83 2 x 5,91 2 x 3,8 2 x 7,98 4 x 5,13 4 x 7,98 Max. total power absorbed kw 2 x,5 2 x 1,35 2 x 1,35 2 x 2,5 2 x 5,2 4 x 3,3 4 x 5,2 9/125/EC ErP Compliance - 215 215 215 215 215 215 215 Motor protection rating IP54 IP54 IP54 IP54 IP54 IP54 IP54 Power supply V-Ph-Hz 23-1-5-3-5 COMPRESSOR Refrigerant gas R41A Type rotary rotary rotary rotary rotary rotary/scroll rotary/scroll Quantity 1 1 1 1 1 2 2 Max current consumption A 12,2 19,2 28,8 24,7 34,2 2 x 24,7 2 x 34,2 Full load power input kw 2,38 3,74 5,63 13, 18, 2 x 13, 2 x 18, Power supply V-Ph-Hz 23-1-5-3-5 ELECTRIC SKE HEATING ACCESSORY (1) Stages 1 1 1 1 1 1 1 Heating capacity kw 6, 1, 14, 28, 48, 64, 8, Current consumption A 8,66 14,4 2,2 4,4 69,3 92,4 115 T air side C 14,7 14, 14,2 14,4 14,9 13,9 12 Pressure drop Pa 25 25 25 25 25 25 25 Power supply V-Ph-Hz -3-5 ELECTRIC SKE HEATING ACCESSORY (2) Stages 1 1 1 1 1 1 1 Heating capacity kw 3, 5, 7, 14, 24, 32, 4, Current consumption A 4,33 7,22 1,1 2,2 34,6 46,2 57,7 T air side C 7,4 7, 7,1 7,2 7,4 7, 6,2 Pressure drop Pa 17 17 17 17 17 17 17 Power supply V-Ph-Hz -3-5 (1) Outdoor air 32 C 5% RH, ambient air 26 C 5% RH (2) Outdoor air -1 C 9% RH, ambient air 22 C 5% RH

FERRARO GROUP Lmf Clima 216 13 Performance PERFORMANCE HPR 14 HPR 2 7 5 3 7 5 3 1 1 1 1 1 1 1 5 1 15 25 3 1 HPR 26 9 7 5 3 1 5 1 15 25 3 35 HPR 5 1 1 1 1 1 3 5 7 1 1 1 1 1 HPR 92 3 5 7 9 1 HPR 144 1 1 1 1 1 1 1 1 1 HPR 25 1 1 1 1 1 3 5 7 9 11 13 15 17 19 21

14 Lmf Clima 216 FERRARO GROUP Noise levels The table lists the sound power values (SWL) in octave bands and totals; it also indicates the values of sound pressure level (SPL) at 1 m, 5 m and 1 m at supply, return and at the outside of the unit. All values refer to the operation of the ducted unit at FULL speed and at the nominal flow rate. SPL return SPL supply SPL external HPR SWL [db] OCTAVE BAND [HZ] SWL SPL SUPPLY SPL RETURN SPL OUTSIDE 1 m 5 m 1 m 1 m 5 m 1 m 1 m 5 m 1 m 63 125 25 5 1 db db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) 14 43, 5, 7, 66, 66, 69, 66, 59, 75 74 58 48 42 55 45 39 43 33 27 2 55, 6, 74, 74, 71, 73, 7, 64, 8 78 62 52 46 59 49 43 48 38 32 26 5, 56, 71, 7, 67, 69, 66, 6, 76 74 57 48 42 54 45 39 43 34 28 5 46, 54, 75, 76, 74, 74, 71, 7, 82 8 62 53 48 58 49 44 47 38 33 92 5, 58, 8, 78, 8, 78, 75, 83, 87 86 68 59 54 64 55 5 52 43 38 144 47, 56, 81, 76, 78, 78, 75, 75, 86 84 65 57 52 61 53 48 5 42 37 25 53, 61, 84, 81, 83, 81, 78, 86, 91 89 69 61 57 65 57 53 53 45 41 Dimensions and weights HPR 14 2 26 5 92 144 25 a mm 25 25 25 25 35 35 35 B mm 13 1195 136 169 22 235 235 C mm 119 119 119 152 185 218 251 L mm 62 785 95 128 161 194 194 H mm 475 475 475 64 85 97 1135 Weight kg 47 56 64 89 112 136 163 E A R M C 16 H 4 H 4 4 L 37 a B KEY M R E A supply return exhaust fresh air

FERRARO GROUP Lmf Clima 216 15 HPR 14 2 26 5 92 144 25 L1 mm 15 L2 mm 1 L3 mm 635 635 635 965 965 965 L4 mm 535 W1 mm 62 785 95 128 161 194 194 H1 mm 455 455 455 62 785 95 1115 L1 L2 L3 L4 H1 x W1 H1 x W1 CFA GAT SKR MS3 CCS Controls Automatic selection of speed EC fans management Management of the cooling circuit with inverter compressor Management of the electronic expansion valve Reading pressure and temperature of the cooling circuit Management of cooling unit defrost Management of summer dehumidification Manual ON-OFF Cool/change over valve management CCS+V33 Defrost recovery management Water coil anti-freeze management ON-OFF electric heater management SKE Filter pressure switch management PSTD Management of ventilation with CO2 probe AQS Management of ventilation with one or two pressure sensors DPS Free-cooling modulating management Free-heating modulating management Management of mixing chamber MS3 Management of motorized dampers SKR+SSE Alarms management Post ventilation Weekly programming Remote ON-OFF Mode change (hot/cold) from digital input Display on board machine Remote display RCT Fixed point adjustment at flow Adjustment of temperature and ambient humidity BMS Modbus RS485 protocol Reference diagram 25 HAV HCV