INTRODUCTION The Martin King Dome is a light weight, inflatable transparent housing for protection of a luminaire from precipitation in temporary outdoor applications. It features a powerful fan that inflates the envelope and cools the lighting fixture, and a pressure-activated switch that automatically cuts off power to the luminaire in the event of deflation. COMPATIBLE LUMINAIRES Use the King Dome only with a luminaire meeting the criteria listed on the back cover. SAFETY PRECAUTIONS Warning! This product is for professional use only. Always ground (earth) the King Dome electrically. Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection. Do not use the King Dome with luminaires that consume more than 1200 watts of power. Do not cover or paint the transparent envelope. Do not push, poke, or press the King Dome once inflated. Do not lean or sit on the King Dome. Do not use the King Dome in very dusty areas. Do not block the air vents. Do not install or operate the King Dome in heavy winds (over 17 m/s or 37 M.P.H.). Keep the King Dome away from small children when not in use.
OPERATION To inflate the King Dome 1 Place the base of the dome on a level surface. 2 Center the luminaire on the King Dome base. Verify that no part of the luminaire can extend over the edge of the base during operation. 3 If you have not already done so, set the fixture operating mode and control address. 4 Connect the luminaire s AC power lead to the 230 V (blue) or 110 V (yellow) outlet on the King Dome base. 5 Lead the data cables through an air vent and connect them to the luminaire. 6 If the luminaire has a power switch, set it to the ON position. (Fixture power is disabled until the King Dome is fully inflated.) 7 Fit the inflatable plastic dome over the base so that the Velcro strip on the dome is right next to, and parallel with, the Velco strip on the base. Secure the plastic dome by wrapping the double Velco tape over both Velcro strips. 8 Apply power to the King Dome. The King Dome automatically inflates when power is applied. Power to the fixture is enabled as soon as the King Dome is fully inflated, To deflate the King Dome 1 Extinguish the lamp by sending a lamp-off command from the controller. 2 Allow the luminaire to cool for at least 10 minutes, then disconnect the King Dome from power. 3 Remove the double band of Velco that secures the plastic dome to the base. 4 Carefully fold and store the plastic dome. 5 Disconnect and remove the luminaire. 6 Remove the data cables and put everything away.
SPECIFICATIONS PHYSICAL Base diameter:......................................... 80 cm (31.5 in) Base height:............................................ 25 cm (9,9 in) Base weight:.......................................... 0.6 kg (1.3 lbs) Long envelope height:.................................. 160 cm (63.0 in) Short envelope height:................................... 80 cm (31.5 in) COMPATIBLE LUMINAIRES Maximum vertical dimension:........................ up to envelope height Maximum base dimensions:..................... 54 x 48 cm (21.2 x 18.9 in) Maximum weight:...................................... 65 kg (143 lbs) Maximum power consumption:.................................. 1500 W ENVIRONMENTAL Maximum ambient temperature (Ta):......................... 25 C (77 F) Maximum wind speed:................................ 17 m/s (37 M.P.H.) Maximum noise:................................... 60 db at 1 m (39 in) AC SUPPLY EU model:...........230 V / 50 Hz with female connection for fixture (2P+T) US model:............120 V / 60 H with female connection for fixture (2P+T) CONSTRUCTION Base:.............................................. 5 mm ABS plastic Base finish:........................................ black, integral color Envelope:..................... transparent 200 my non-flammable PVC film Protection factor:............................................... IP 44 Martin Professional A/S Olof Palmes Allé 18 8200 Aarhus N Denmark Phone: +45 87 40 00 00 Internet: http://www.martin.dk
OUTDOOR PROTECTION DOME
Assembly Procedure Triangle notch points down Reinforcement plate L-shaped lip Leave top and bottom holes free Assembling the side plates 1. Remove the parts from the packing boxes. 2. Assemble the plastic side plates. Stand 2 plates with the L-shaped lip pointing up. Fit the plates together with the ends overlapping. Place a metal reinforcing plate behind the joints with the notch pointing down. Start 6 self-tapping screws (M4 x 10 mm) in each joint, leaving the top and bottom holes free. Make sure these holes are lined up as you tighten the screws. 3. Place an assembled set of side plates on a level surface. Sealing the polycarbonate dome with silicone is recommended, but not absolutely necessary if total disassembly of the Dome is required. If sealing, cut 20 to 25 mm off the end of the sealant applicator tip. Apply a heavy bead (about 7 mm) of sealant in the corner of the L-shaped lip. 4. Line up the holes in the rim of the polycarbonate dome with the holes at the top of the side plates and set the dome on. Place rubber grommets at the 4 screw holes between the PN 35000055, Rev C Outdoor Protection Dome 2
dome and the side plates. Insert screws (M4 x 20 mm). From inside, put a washer and thumb nut on the screws and hand tighten. If the nuts are hard to start behind the reinforcing plates, the washers may be omitted. 5. To lengthen the Dome for use with the MAC 1200 or PAL 1200, place the upper section on an assembled set of side plates. Rotate the upper section so that the reinforcing plates are offset 1/4 turn from the reinforcing plates in the lower section. Insert M4 x 20 mm screws in the 4 holes. Place a washer and hex nut on each screw and tighten. Repeat to lengthen the Dome for use with the PAL 1200. 6. There are two ways to lead the power and control cables into the bottom of the base: through the square hole or the smaller slot. For temporary installations, use the square hole for easier access. The slot may provide a more secure cable lead for permanent installation. If the slot is used, remove a side plate from the base assembly in order to pass the power and control cables through the slot. Feed the control cable up through the peanut-shaped ventilation hole to the top of the base section. 7. Reach inside the base and plug the power cable into the male power connector. This connector feeds power to the cooling fan as well as the socket on the base. 8. Mount the base in position. The Dome may be secured through 4 holes in the base. Make sure that the air vents are not obstructed and that air can circulate in and out. Do not locate the Dome in low spots where water can collect. 9. If the Dome is to be used with a PAL 1200, attach 2 ventilation-spacer bars, included, to the base of the PAL. Remove the 4 bolts indicated and place the bars on the base as shown, with the shorter length facing the front. Fasten each bar with 2 M6 x 35 mm Allen-head bolts. 10. Plug the fixture power cable into the base. Place the fixture on the base. Make sure the base ventilation holes are not blocked. 11. PAL 1200 Dome only: Orient the PAL so that the back of the fixture faces the square ventilation hole. 12. MAC 500/600 Dome only: Align the base of the MAC with the raised mounting plate. Lock the MAC to the base by inserting the quarter-turn fasteners into the MAC base and turning them a full quarter turn clockwise. 13. Remove the 4 screws - located every 90 degrees around the top - from the base. Place the upper section on the base. Rotate the upper section until the joints are offset 1/4 turn from the joints in the base. Replace the 4 screws and tighten. PN 35000055, Rev C Outdoor Protection Dome 3
Safety Precautions Do not place the Dome where water can build up. Always stand the Dome vertically with the clear plastic dome on top. The Dome is not designed to be used in any other position. Make sure the base air vents are not blocked. Do not paint or cover the Dome, or in any way block the light path. Always connect the Dome to mains power as specified on the serial number label. Use only undamaged cables rated for outdoor use. Do not disassemble the base. There are no user-serviceable parts inside. Specifications IP Rating:... IP 44 PAL 1200 Dome Power and Current:...160 W, 0.7 A at 230 V/50 Hz MAC 1200 Dome Power and Current:...160 W, 0.7 A at 230 V/50 Hz MAC 500/600 Dome Power and Current:...105 W, 0.5 A at 230 V/50 Hz AC Voltage and Frequency:... 230 V, 50-60 Hz Diameter:...825 mm PAL 1200 Dome Height, Weight:... 1740 mm, 55 kg MAC 1200 Dome Height, Weight:... 1380 mm, 53 kg MAC 500/600 Dome Height, Weight:... 1020 mm, 52.5 kg PN 35000055, Rev C Outdoor Protection Dome 4