S3090X-001* S3175X-001*

Similar documents
ALG LED Area Light K lm 21000lm 33000lm 100W 150W 300W. Type III Type V

SPECIFICATION FOR APPROVAL

SPECIFICATION OF. USFLxxWTS LED FLOODLIGHT 5YEARS E468007

INUI - 400W-CREE-XTE Specification

Applications. Standard Colors. Features. T1P Series LED Street Light (Ver2.0)

LED Value Ceiling Light

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

LED. High-performance streetlight. -afortable and reliable

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

LED Vapor Tight For Tough Environments

Reliable low profile LED Street Light

25 Watt Magnetic LED Light - 250W Metal Halide Equivalent Watt High Output LEDs - LEDWP-250

4 Watt LED Bulb ENERGY BULBS MODELS: EST C pic 1. pic 2. pic 3. pic 4

High-density LED modules that sell

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

Application Note SubstiTUBE ST8-SD4

UNIVERSAL LIGHT 15-24W. IP64 WARRANTY

CT8000. NEW The World's 1st 4th Generation IOT / CuI Technology. Housing Color. Weight & Dimension p.217. Standard & Option.

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

PRODUCT FAMILY DATASHEET LEDVANCE HIGH BAY LED

Description: RX-ALF28T Series Waterproof LED module, Ultra-Slim Light Box direct type light source - can be continuously

CT2500. NEW The World's 1st 4th Generation IOP / CuI Technology. Housing Color. Weight & Dimension p.189. CCT (Correlated Color Temperature)

P855. Next Generation High Mast LED Luminaire with variable geometry STAR-optic

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

LED DOWNLIGHTS. Prime K L LED Downlights HIGH QUALITY COB TECHNOLOGY LED-DOWNLIGHTS

75% ENERGY SAVINGS 200W-600W HID Light Replacement

Fortimo LED Line Gen3

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Experience bright and vivid colors

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Application. Standard Colors. Features. - Tunnel lighting. Black

CD3000. NEW The World's 1st 4th Generation IOP / CuI Technology. Housing Color. Weight & Dimension. CCT (Correlated Color Temperature)

Technology with Vision. HeLLA HypaLUME HEAVY DUTY LED FLOOD LIGHT

Experience bright and vivid colors

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Low profile frame is just 0.5" thick CONFIGURATIONS

ABOUT MIDNIGHT DIMMING

TUNNEL LED LIGHTING. High power, low consumption public LED lighting

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

S T O R K L I T T L E B R O T H E R

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

Explosion Proof 70W LED Light Fixture - C1D2 - Adjustable Magnet Base - Curved Mounting Surfaces

LED Sport Flood 250W-1250W

Specifications. Product Name : LED Freezer Light. Model : Date : Version : A 1 ONN-X3F. Shenzhen Onn Semi-conductor lighting Co.

TMU040005ELXXXA TMU040005ELXXXB

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Innovation. New LED Lights for Smart Indian & Global Cities. Lights for Life. For Exploring LED Technology Benefits. 12m m

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS

defender-s NJZ-FEL-B Series Hazardous Locations&Explosive Atmospheres Zone1&2, Zone21&22 II 2G Ex d IIB T5 Gb II2D Ex tb IIIC 95 Max Db IP 66

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

TMU040010ELXXXA TMU040010ELXXXB TMU040010ELXXXC

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LF30Series LED Flood Light

240 Photo: Omri Amsalem

Corn Light Series. Various lamp holder are available, a wide range of applications. (E26/E27/E39/E40);

LED T8 glass tube 4ft 18W

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Specification Manual HIGHBAY LED HIGHBAY SL80N4-KE-CRB(DC) SL80N4-KE-CRB(DF) SL80N4-KE-CRB(DW) Pre-Promotion Version_01

CH2500. NEW The World's 1st 4th Generation IOP / CuI Technology. Housing Color. Weight & Dimension. CCT (Correlated Color Temperature)

Technical information MINI NICOLE, NICOLE & MAXI NICOLE LUMINAIRES

POWER SAVED IS POWER GENERATED

Technical Specification

LuxBeacon Series. rontand. Best Maker for LED Lighting. High Power LED Flooding/ Spot Lamp. Index

34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise

150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

PCB & DRIVER LED SOLUTIONS

KATU- JA ALUEVALAISTUS PRO FLOW

TET120013RDXX-X1,TEMUNV013RDXX-X1 TKT120013RDXX-X1,TKMUNV013RDXX-X1

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

LEDVANCE SUPERSTAR LED Downlight Gen 2

242 Photo: Omri Amsalem

Honeycomb briquette cooling technology Double-coupling IP68 protection, highest waterproof level

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

TECHNICAL DIVISION GALILEO 1 EB Rev. OCT-15

Specification sheet of T8 LED Tube

E-CORE LED LIGHT ENGINE 2 AND DALI DATA SHEET 1 / 7. Application:

ClearFlood Large The best solution for 1:1 retrofit

IVIOS LED III. LUM Technical Information

Technical Application Guide for UP-SHINE LED Tube Light

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

UFO LED High Bay Light DATASHEET

G4 LED HID Retrofit. Standards Manual

LD10 Luminus Light Engine

Flexible system approach

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

OBB. NEW The World s 1st 4th Generation IOP / CTI Technology Explosion Proof Light Security Light Street Light

Efficient fluorescent lighting with improved color rendering

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

TECHNICAL DIVISION GALILEO 2 EB Rev. MAY-16

EcoSpec Linear INT - Standard Power

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine

Special for big or middle column billboard,for example,18x6m single

Technical Application Guide for UP-SHINE Tri-proof LED light UP-TRP W

Associated Rsets. Associated Drivers. XI013C030V048DNM1 0-10V dimming Rset2. XI025C100V045DNM1 0-10V dimming Rset2

ZIPAR FAMILY MINIMALISTIC DESIGN WITH IDEAL FOR RETAIL. MINIMALISTIC SYSTEM EFFICACY IDEAL FOR RETAIL. 83 Ra PASSIVE COOLING. up to.

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

Transcription:

CooLED Corp. 9000 Lm Street Light Spec Sheet S3 Series P/N S3090X-001* S3175X-001* Picture Rated Lumen ** Rated Voltage 9000 lm (Measured value:9073.8 lm) 100~240V, 50/60HZ 17500 lm (Measured value:17580.3 lm) Power Factor >0.95 Lighting Efficacy ** 5000K / 3000K Rated Power 75W 150W Color Temp 119.1 lm/w 117.3 lm/w CRI >80 >80 Beam Angle 140 x 75 Central lux@6500k (1M/2M/3M) 2745Lx/ 686Lx/ 305Lx 5041Lx/ 1260Lx/ 560Lx Dimension(±2mm) 431mm(L)x 160mm(W)x89mm(H) 632mm(L)x 215mm(W)x90mm(H) Weight(±5%) 3200g 5100g * X Can be replaced by C:5000K/ W:3000K. **The value is measured at 5000K.

Content 1. Introduction 2. Features 3. Application 4. Dimensions 5. Photometry 6. Operation Condition 7. Specification 8. Packaging 9. Wiring and Installation Instruction 11. Out-Door Wiring for Water-Proof 10. Warranty 3 3 3 4 5 6 6 7 8 9 10

Introduction S3090 9000Lm LED Out-Door Street light is a revolutionary product, its higher efficacy (115Lm/W) and powered by Meanwell(ELG) provides a better energy saving solution, longer product life time, and good stability(ip66) in out-door environment. Features 1. Use fin-structure aluminum hosing for excellent thermal dissipation and light weight. 2. Using high efficacy LED module to perform 115 steady lighting lumen per wattage. 3. Higher color rendering, CRI>80 with R9>0 4. IP66 waterproof level. 5. Testing report ready by TAF lab (IP66 and light density distribution for 5000K) 6. Easy to install. 7. Meet RoHS standard. Application 1. Landscape lighting 2. Sidewalk lighting 3

Dimension unit:mm Photometry Central Lux 5000K@220V 1M 2745.3LUX 2M 686.3LUX 3M 305.0LUX 4

Photometry S3090C-001@220V Isocandela diagram C0/C180 C90/C270 Cartesian coordinates 5

Operation Condition Input voltage :100~240V / 50/60Hz Operation ambient temperature :-30 to +40 Storage temperature :-40 to +60 Specification Parameter Rating Unit AC Input Voltage 100~240 VAC Frequency 50/60 Hz Operation Ambient Temperature -30 to+40 Color Temperature 5000 / 3000 K Rated Lumen 9000(Measured value:9073.8 ) lm Lighting Efficacy 119.1 lm/w CRI >80 Dimension(±2mm) 431(L)x 160(W)x89(H) mm Weight(±5%) 3200 g Lifetime 40000 hour Beam Angle 140 x 75 degree Notes: 1. Luminous flux is measured at 5000K and with an accuracy of ±10%. 2. Luminous flux is measured at TA= 25 C and reaches thermal equilibrium. 6

Packaging 47(L)*22(W) *14.5(H) 1 layer= 10 ea total 12 layers 1 pallet= 120ea S3090 Pallet dimension: 110*110*13 unit: cm 7

Wiring and Installation Instruction 40mm pole cover 60mm pole cover Confirm the pole diameter to use the correct accessories, then screw the pole cover at the back side of lamp by cross screwdriver. Before installation After installation Wiring Instruction: 1. Install lamp by the professional person with electrical license. 2. Make sure the power is off before installation. 3. Make sure no high power-consumption equips nearby the lamp (e.g., elevator, refrigerator, air-conditioner). It will generate surge that may damage the lamp while start up. 4. Connect blue cord of lamp to AC/N; brown cord to AC/L. 5. Connect ground cord of lamp(yellow/green) to ground. 6. DO NOT use any tools to disassemble or repair lamps. 7. Products are available for AC 100V~240V, 50/60Hz. DO NOT install lamp to the environment out of the range. Installation Instruction: 1. Follow the blue arrow to unscrew the bolts and nuts by hexagon key in a counterclockwise direction before installation. 2. Confirm the pole diameter to choose the correct pole cover (40 mm or 60 mm) before installation. Then screw it at the back side of lamp. 3. Connect the power cords of lamp with AC power cords inside the pole before install the lamp on the pole. 4. Follow the red arrow to push the lamp into the pole. 5. Follow the yellow arrow to screw the bolts tight by hexagon key, then tight nuts by wrench in a clockwise direction. 6. Make sure the screws are tight and the lamp are fixed firmly with the pole. 8

Out-Door Wiring for Water-Proof Caution: 1. Read the instruction carefully before wiring. 2. Make sure the power is off before installation. 3. Make sure no high power-consumption equips nearby the lamp (e.g., elevator, refrigerator, airconditioner). It will generate surge that may damage the lamp while start up. 4. Non-professional staff shall not use any tools to disassemble or repair lamps. 5. Products are available for AC 100V~240V, 50/60Hz. DO NOT install lamp to the environment out of the range. Note: Emergency handling: Turn off the power when the lamp is abnormal. 1 2 3 4 Tie the 3-cord cable of lamp by insulation tape to cover all branch area for water-proof. Same as the cable of AC side. Twist bare wires of lamp ground cord and AC ground cord together at the same direction. Same as live cords(l) and neutral cords(n). Fold up the front end of bare wires to prevent tape falling off. Then cover it by isolation tape. Continue winding bare wires by tape. It should be over the front end of bare wires 4 to 8 cm. 5 6 7 8 Pull the surplus tape back to prevent bare area from getting vapor. Repeat step 4 and 5 at least 3 times. Refer to Electrical Engineering Rules about winding methods and standards. Make sure 3 groups of wires are covered by tape firmly, then start to wind the tape from the branch point of two main cords. Keep winding the tape and ensure two main cords covered by tape firmly. 9 10 11 12 Continue winding 3 groups of wires by tape. It should be over the front end of bare wires 10 to 15 cm. Pull the surplus tape back to prevent bare area from getting vapor. Note: Turn off the power during wiring to prevent lamp damage because of abnormal wiring. 9 Repeat step 8 and 9 at least 3 times. Refer to Electrical Engineering Rules about winding methods and standards. Fold up the cords with tape and face up. The cord position has to lower than lamp, or vapor will follow the cords into the lamp when it rains.

Warranty We offer two year limited warranty on the entire system. 1.Under normal condition with no mechanical damage or LED light module disassembly, LED lumen degradation is within 30%. (Under the environment of room temperature 25 C, the LED life maybe more than 50000 hr) 2.Warranty does not provide coverage for product damage resulting from the end user s failure to replace surge protection devices before they have reached their useful life. 3. Warranty does not provide coverage for product damage resulting from the natural disasters like typhoon, flood etc. 4.CooLED is not responsible for the product which is transformed or dismantled without permission. We reserve the right to modify, and/or to withdraw any part of data sheet herein. 10