Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Similar documents
Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

Self-Testing Industrial Series

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Spectron Industrial Series

IMPORTANT SAFEGUARDS

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

When using electrical equipment, basic safety precautions should always be followed including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions Central Battery Units

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

MIRRORLITE RECESSED EMERGENCY LIGHTING

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTALLATION AND OPERATING INSTRUCTIONS

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

EMIU 720W Mini Inverter

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

SAVE THESE INSTRUCTIONS

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Installation Instruction

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

Cat# DC LED Array Emergency Driver

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

SCION FR-S FOG LIGHTS

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

SAVE THESE INSTRUCTIONS

SURE-LITES FBP140XLP Instruction Manual

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instructions & Users Manual

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Concealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions

SCION xb 2004 SECURITY (V5) Section I Installation Preparation. Part Number:

To The. We ve Taken Exit Signs. Elegant Styling Industry-Leading Quality And Performance Easy, Trouble-Free Installation

The Da-Lite Difference.

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

Installation And Operation Instructions

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

Installation and Operation Instructions 10/04/13

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Instruction Book for. ContouR ElECtRol

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

INSTRUCTION MANUAL SINKER. By HAY

The Da-Lite Difference.

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

TOYOTA TUNDRA TVIP V3 (RS3000) Section I - Installation Preparation

SCION tc ILLUMINATED DOOR SILLS Preparation

The Da-Lite Difference.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Installation Instructions: Eco Linear High Bay

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation And Operation Instructions

Technical Service Bulletin

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

UL AND CODE COMPLIANCE

WARNING. Important Notice

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

LEXUS GS 350/450h ILLUMINATED DOOR SILLS Preparation

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

The LED Driver Expert

FHS2-UNV-56S SPECIFICATIONS

Installation Instructions and User Manual For. 100 Watt Inverter Power System

LIPPERTCOMPONENTS, INC.

TOYOTA im INTERIOR LIGHT KIT Preparation

The Da-Lite Difference.

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

TOYOTA RAV FOG LIGHT KIT Preparation

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

3 in 1 TRAIL CHARGER with LOCKOUT

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

OutdoorXUPS-600AHV-8364

Optima ETF-600/ETF-610

SAVE THESE INSTRUCTIONS!!

Q35 Series Automatic Vent Damper System

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

2002 Dodge Intrepid ES ACCESSORIES & EQUIPMENT Anti-Theft Systems - Concorde, Intrepid & 300M

Installing Power Components

Color Applicability/Trim Level. Hardware Bag Contents Item # Quantity Reqd. Description

FHS2-UNV-36L INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

LED Downlight Ceiling Fixtures

PIL0478 ISSUE 01/ 07/16

Transcription:

Prestige Series Edge-Lit LED Sign AC, AC/DC and Self-Powered models Prestige Series Edge-Lit LED Sign WARNING: Risk of Shock. Disconnect Power before Installation. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: 2 4 8 Surface mount 3 5 6 7 Recessed mount 1 9 10 READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. All servicing should be performed by qualified service personnel. 2. Do not use outdoors. 3. Do not let power supply cords touch hot surfaces. 4. Do not mount near gas or electric heaters. 5. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 6. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 7. Do not use this equipment for other than its intended use. SAVE THESE INSTRUCTIONS Installation Instructions Turn off AC power. This sign shall be installed only where there is adequate colour contrast between the sign legend and the interior wall finish behind the sign, to provide for sufficient visibility. Wiring connections need to be done away from PCBA and in designated area as shown in figure 8 or 9. Recessed mount installation (New construction or rear access) (Figure 2a & b) 1. Remove the proper knockout in the back box for the entry of the AC wires. 2. Assemble the recessed mounting brackets to the back box. Install the bar hangers in the adjustment brackets. Mount the back box. The back box must be flush with the wall or ceiling surface (see figure 2b). Contact customer service in the event where it s not possible to have the back box flush with the wall or ceiling. 3. Route AC circuit of rated voltage into the back box and leave 6 of wire length. 4. Connect the incoming ground to the short ground wire provided in the back box. Surface mount installation (Figures 3a,b,c) 1. Remove the proper knockout in the canopy plate to mount to the junction box, check the orientation of the back box (see figures 3a, b or c). 2. Route the wires through one of the Ø5/8 knockout holes in the canopy plate and mount the plate to the electrical box using the junction box screws. Make sure that the canopy plate will mount so the securement screw is accessible. Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1421 Rev. F 11 Figure 1 Parts List 1. Recessed mount brackets 8. Securement screw (recessed only) 9. 2. Junction box 10. Trim ring (recessed only) 3. Canopy plate 11. Nipples (2) 4. Junction box screws (not 12. assembly provided) 13. Clips (2) 5. Nuts (2) 14. Exit panel 6. Nylon washer (2) 15. Hook (refer to fig.7) 7. Canopy Figure 2a FLUSH Figure 2b Ceiling or Wall assembly to be flush with this surface. 13 14 Bar Hangers 12 L shaped brackets (not needed for flat trim) Adjustment brackets OFFSET 1/4

3. Remove the proper knockouts in the back box to mount the canopy (see figures 3a, b or c). 4. Mount the canopy to the back box using the hardware supplied (see figures 3a, b or c). 5. Route wires from the harness through the back box/canopy assembly. 6. Using the hook provided, hang the canopy/back box assembly to the canopy plate (figure 7). 7. Go to electrical connections for wiring information. 8. Mount the canopy/back box assembly to the canopy plate using the securement screw provided. Figure 3a Figure 3b Wall mount Ceiling mount Prestige Series Edge-Lit LED Sign Figure 3c End mount For end mount use: use the 2 knock-out holes located on one end of the back box. installation 1. The trim plate module comes assembled for surface mount or recessed ceiling mount installation (figure 4). If surface or recessed ceiling mount, continue with step 3. Surface ceiling mount Surface wall mount Recessed ceiling mount Recessed wall mount Figure 4 2. Recessed wall-mount installation (Figures 5a,b,c) a. To remove the electronic module, unscrew the bracket on either end of the module. Disconnect the transformer harness from the electronic module in the plastic housing. Remove the electronic module. b. Unscrew the side plate of the trim plate body. Turn the side plate around and screw it back in place, this time flush with the trim plate body. Figure 5a Lip up Lip down Figure 5b Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1421 Rev. F 2/4

Prestige Series Edge-Lit LED Sign c. Re-install the electronic module and the bracket, this time oriented as in (Figure 5c). Reconnect the transformer harness to the electronic module. 3. Recessed installation (figure 6). Attach the flat trim ring to the trim plate. Orient the trim ring and snap it with the two tabs behind the hooks of the side brackets. 4. Electrical connection (Figures 8,9) a. Connect the long ground lead with eyelet from the back box to the trim plate assembly with the hardware provided. b. Make the proper connections. The system can accept input voltages of 120 VAC to 347 VAC. For regular models connect the purple (line) and white (common) leads to the building utility (figure 8). For models with diagnostic feature connect the white (common) and black (120 VAC) or orange (277 VAC) leads to the building utility (figure 9). c. For remote power DC unites, connect the red wire to the positive of the DC supply and the blue to the negative (6 to 24 volts). 5. Take the trim plate assembly and connect the harnesses together with the back box mating colors. 6. Compress the retention springs and insert the trim plate assembly into the back box. Align the trim plate assembly flush with the back box, wall or ceiling installation. Figure 5c Figure 6 Trim ring tab Trim ring tab this side Hook on trim plate assembly Figure 7 Red + DC Purple AC White neutral 15 Canopy Blue - DC Note: The hook is used for surface mount units only. DC wires for remote DC supply Figure 8 (Regular models) LED Strip Make wiring connection inside back box within this area, away from PCBA. Red + Fire alarm Blue + Fire alarm DC wires for Fire alarm input Orange 277VAC Black 120VAC White neutral Transformer Canopy LED Strip Figure 9 (Models with diagnostic feature) Make wiring connection inside back box within this area, away from PCBA. Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1421 Rev. F 3/4

Prestige Series Edge-Lit LED Sign Exit panel installation (Figure 10) 1. Remove the exit panel from its carton, do not remove the protective sleeve until the installation is complete. 2. Partially remove the protective sleeve at the top of the exit panel. Push the exit panel, with the clips, into the slot in the trim plate assembly until it snaps. Gently try to pull out the panel to ensure that it is engaged in the trim plate assembly. Remove the protective sleeve. 3. For self powered models, connect the two terminals (located on the red wires) together. 4. Energize AC circuit. Exit and green pilot indicator (self-powered models) will illuminate. The exit panel can only be removed by lowering the trim plate and pushing on the end clip located on the opposite side of the test switch with a screwdriver. Figure 10 Self Powered models Manual testing (Figure 11) Press test switch. Legend will flicker then will remain lit. On release an external green LED will illuminate and the automatic charger will restore battery to full power. AC Pilot light / Test switch Diagnostic light (optional) Automatic testing and diagnostics (optional) The models with the automatic testing and diagnostic option include a microcontroller which tests the unit on a monthly basis and identifies as well as displays failures of the electrical components: battery, charger circuit, LED lamps. Self-test The self-test is performed every 30 days for 30 seconds, every 60 days for 30 minutes, and annually for 90 minutes. Diagnostic function (Figure 11) The diagnostic function uses the pilot light LED indicator. Service is required if the green LED changes color to red indicating that an alarm condition is detected. Figure 11 Pilot light Status Diagnostic Green Steady Normal (AC On) Green Blinking Auto Test Red Steady on Battery Disconnect Red One Blink Battery Failure Red Two Blinks Charger Failure Red Four Blinks LED Lamp Failure Maintenance None required. Models equipped with batteries: if AC supply is to be disconnected for 2 months or more, the battery must be disconnected (Self-Powered Models only). Note For safety reasons Nickel Cadmium batteries are shipped discharged. The unites may require 10 minutes of connection to AC supply before start-up test procedure, and two to seven days to reach full charge. Warranty: For the complete warranty information, please refer to the landing page of our website (http://www.emergi-lite.com/usa/). Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1421 Rev. F 4/4

Prestige Series - Edge-Lit LED Less panel AC, AC/DC and Self-Powered models IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. All servicing should be performed by qualified service personnel. 2. Do not use outdoors. 3. Do not let power supply cords touch hot surfaces. 4. Do not mount near gas or electric heaters. 5. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 6. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 7. Do not use this equipment for other than intended use. SAVE THESE INSTRUCTIONS Installation Instructions Turn off AC power. WARNING: Risk of Shock. Disconnect Power before Installation. This sign shall be installed only where there is adequate colour contrast between the sign legend and the interior wall finish behind the sign, to provide for sufficient visibility. Wiring connections need to be done away from PCBA and in designated area as shown in figure 8 or 9. 4 2 8 11 Figure 1 Prestige Series - Edge-Lit LED Less panel Surface mount 3 5 6 7 Recessed mount or EXIT Panel may not be provided. Refer to /Panel assembly parts list (located on last page) for ordering. CAUTION: Only the listed assemblies can be installed with this unit. Parts List 1. Recessed mount brackets (recessed only) 2. Junction box 3. Canopy plate 4. Junction box screws (not provided) 5. Nuts (2) 6. Nylon washer (2) 7. Canopy 8. Securement screw 9. 10. Trim ring (recessed only) 11. Nipples (2) 12. assembly 13. Clips (2) (Shipped with panel) 14. *Exit panel (Not included. Shipped separately. Refer to panel parts list). 15. Hook (refer to fig.7) 13 14 1 9 10 12 * Recessed mount installation (New construction or rear access) (Figure 2a & b) 1. Remove the proper knockout in the back box for the entry of the AC wires. 2. Assemble the recessed mounting brackets to the back box. Install the bar hangers in the adjustment brackets. Mount the back box. The back box must be flush with the wall or ceiling surface (see figure 2b). Contact customer service in the event where it s not possible to have the back box flush with the wall or ceiling. 3. Route AC circuit of rated voltage into the back box and leave 6 of wire length. 4. Connect the incoming ground to the short ground wire provided in the back box. Surface mount installation (Figures 3a,b,c) 1. Remove the proper knockout in the canopy plate to mount to the junction box -check the orientation of the back box (see figures 3a, b or c). 2. Route the wires through one of the Ø5/8 knockout holes in the canopy plate and mount the plate to the electrical box using the junction box screws. Make sure that the canopy plate will mount so that the securement screw is accessible. Figure 2a FLUSH Figure 2b Ceiling or Wall assembly to be flush with this surface. Bar Hangers L shaped brackets (not needed for flat trim) Adjustment brackets OFFSET Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1586 Rev. B 1/4

Prestige Series - Edge-Lit LED Less panel 3. Remove the proper knockouts in the back box for mounting to the canopy (see figures 3a, b or c). 4. Mount the canopy to the back box using the hardware supplied (see figures 3a, b or c). 5. Route wires from the harness through the back box and canopy. 6. Using the hook provided, hang the canopy/back box assembly to the spider plate (figure 7). 7. Go to electrical connections for wiring information. 8. Mount the canopy/back box assembly to the spider plate using the two 1" screws provided. Figure 3a Figure 3b wall mount ceiling mount Figure 3c end mount For end mount use the 2 knockout holes located on one end of the back box. installation 1. The trim plate module comes assembled for surface mount or recessed ceiling mount installation (Figure 4). For surface or recessed ceiling mount, go to step 3. Surface ceiling mount Surface wall mount Recessed ceiling mount Recessed wall mount Figure 4 or EXIT Panel may not be provided. Refer to /Panel assembly part list (located on last page) for ordering. CAUTION: Only the listed assemblies can be installed with this unit. 2. Recessed wall-mount installation (Figures 5a,b,c) a. To remove the electronic module, unscrew a bracket on either end of the module. If the unit has a transformer: disconnect the transformer harness from the electronic module in the plastic housing. Remove the electronic module. b. Unscrew the side plate of the trim plate body. Turn the side plate around and screw it back in place, this time flush with the trim plate body. Figure 5a Lip up Lip down Figure 5b Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1586 Rev. B 2/4

Prestige Series - Edge-Lit LED Less panel c. Re-install the electronic module, this time oriented as in (Figure 5c). For units with transformer: reconnect the transformer harness to the electronic module. 3. Recessed installation (Figure 6). Attach the flat trim ring to the trim plate. Orient the trim ring and snap it with the two tabs behind the hooks of the side brackets. 4. Electrical connection (Figures 8,9) a. Make the proper connections. The system can accept input voltages of 120 VAC to 347 VAC. For regular models connect the purple (hot) and white (common) leads to the building utility (Figure 8). For models with diagnostic feature connect the white (common) and black (120 VAC) or orange (277 VAC) leads to the building utility (Figure 9). b. For remote power DC unites, connect the red wire to the positive of the DC supply and the blue to the negative (6 to 24 volts). 5. Take the trimplate assembly and connect the harnesses together with the back box mating connector. 6. Compress the retention springs and insert the trim plate assembly in the back box. Align the trim plate assembly flush with the back box, wall or ceiling as installed. Figure 7 Figure 5c Figure 6 Trim ring tab Trim ring tab this side Hook on trim plate assembly 15 Red + DC Blue - DC Purple AC White neutral Note: The hook is used for surface mount units only. Canopy DC wires for remote DC supply Figure 8 (Regular models) LED Strip Make wiring connection inside back box within this area, away from PCB. Exit panel installation (Figure 10) 1. Remove the exit panel from its carton, do not remove the protective sleeve until the installation is complete. 2. Partially remove the protective sleeve at the top of the exit panel. Push the exit panel, with the clips, into the slot in the trim plate assembly until it snaps. Gently try to pull out the panel to ensure that it is engaged in the trim plate assembly. Remove the protective sleeve. 3. For self powered models, connect the two terminals (located on the red wires) together. 4. Energize AC circuit. Legend and green pilot indicator (self-powered models) will illuminate. The Exit panel can only be removed by lowering the trim plate and pushing on the end clip located on the opposite side of the test switch with a screwdriver. Self Powered models Manual testing (Figure 11) Press test switch. Legend will flicker then will remain lit. On release an external green LED will illuminate and the automatic charger will restore battery to full power. Red + Fire Alarm Blue - Fire Alarm Canopy LED Strip DC wires for Fire alarm input Orange 277VAC Black 120VAC White neutral Figure 9 (Models with diagnostic feature) (Optional) Transformer Make wiring connection inside back box within this area, away from PCB. Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1586 Rev. B 3/4

Prestige Series - Edge-Lit LED Less panel Automatic testing and diagnostics (optional) The models with the automatic testing and diagnostic option include a microcontroller which tests the unit on a monthly basis and identifies as well displays failures of the electrical components: battery, charger circuit, LED lamps. Self-test The self-test is performed every 30 days for 30 seconds, every 60 days for 30 minutes, and annually for 90 minutes. Diagnostic function (Figure 11) The diagnostic function uses the pilot light LED indicator. Service is required if the green LED changes color to red indicating that an alarm condition is detected. Pilot light Status Diagnostic Green Steady Normal (AC ON) Green Blinking Auto Test Red Steady on Battery Disconnect Red One Blink Battery Failure Red Two Blinks Charger Failure Red Four Blinks LED Lamp Failure Maintenance None required. Models equipped with batteries: if AC supply is to be disconnected for 2 months or more, the battery must be disconnected (Self-Powered Models only). Note For safety reasons Nickel Cadmium batteries are shipped discharged. The unites may require 10 minutes of connection to AC supply before start-up test procedure, and two to seven days to reach full charge. Warranty: For the complete warranty information, please refer to the landing page of our website (http://www.emergi-lite.com/usa/). or EXIT Panel may not be provided. Refer to /Panel assembly part list (located on last page) for ordering. CAUTION: Only the listed assemblies can be installed in this unit. Figure 10 Figure 11 AC Pilot light / Test switch Diagnostic light (optional) Description Description Description Part No. Red Legend (Legend/Background color) Part No. Green Legend (Legend/Background color) Part No. Blue Legend (Legend/Background color) Back Box 004216-E 1-F (Red/Clear) no Arrow 004251-E 1-F (Green/Clear) no Arrow 004713-E 1-F (Blue/Clear) no Arrow 004216-E 1-F (Red/Clear) Arrow Left 004268-E 1-F (Green/Clear) Arrow Left 004741-E 1-F (Blue/Clear) Arrow Left 004218-E 1-F (Red/Clear) Arrow Right 004269-E 1-F (Green/Clear) Arrow Right 004899-E 1-F (Blue/Clear) Arrow Right 004219-E 1-F (Red/Clear) Dbl-Arrow 004252-E 1-F (Green/Clear) Dbl-Arrow 004900-E 1-F (Blue/Clear) Dbl-Arrow 005650 - Recessed mount Back Box (Recessed model only) 004208-E 1-F (Red/White) no Arrow 004243-E 1-F (Green/White) no Arrow 004901-E 1-F (Blue/White) no Arrow 005651 to 005XXX - 004209-E 1-F (Red/White) Arrow Left 004271-E 1-F (Green/White) Arrow Left 004902-E 1-F (Blue/White) Arrow Left Surface mount Back 004210-E 1-F (Red/White) Arrow Right 004279-E 1-F (Green/White) Arrow Right 004903-E 1-F (Blue/White) Arrow Right Box (the Three last digits 004211-E 1-F (Red/White) Dbl-Arrow 004270-E 1-F (Green/White) Dbl-Arrow 004904-E 1-F (Blue/White) Dbl-Arrow designate color) 004229-E 2-F (Red/White) no Arrow 004274-E 2-F (Green/White) no Arrow 004905-E 2-F (Blue/White) no Arrow 004230-E 2-F (Red/White) Arrow Right and Left 004264-E 2-F (Green/White) Arrow Right and Left 004742-E 2-F (Blue/White) Arrow Right and Left 004255-E 2-F (Red/White) Dbl-Arrow 004284-E 2-F (Green/White) Dbl-Arrow 004906-E 2-F (Blue/White) Dbl-Arrow 004242-E 1-F (Red/Mirror) no Arrow 004260-E 1-F (Green/Mirror) no Arrow 004907-E 1-F (Blue/Mirror) no Arrow 004265-E 1-F (Red/Mirror) Arrow Left 004288-E 1-F (Green/Mirror) Arrow Left 004908-E 1-F (Blue/Mirror) Arrow Left 004262-E 1-F (Red/Mirror) Arrow Right 004287-E 1-F (Green/Mirror) Arrow Right 004909-E 1-F (Blue/Mirror) Arrow Right Note: 004257-E 1-F (Red/Mirror) Dbl-Arrow 004286-E 1-F (Green/Mirror) Dbl-Arrow 004910-E 1-F (Blue/Mirror) Dbl-Arrow 1-F = Single Side 004249-E 2-F (Red/Mirror) no Arrow 004261-E 2-F (Green/Mirror) no Arrow 004911-E 2-F (Blue/Mirror) no Arrow 2-F = Double 004259-E 2-F (Red/Mirror) Arrow Right and Left 004254-E 2-F (Green/Mirror) Arrow Right and Left 004743-E 2-F (Blue/Mirror) Arrow Right and Left Side 004258-E 2-F (Red/Mirror) Dbl-Arrow 004253-E 2-F (Green/Mirror) Dbl-Arrow 004912-E 2-F (Blue/Mirror) Dbl-Arrow Emergi-Lite Tel: (888) 552-6467 Fax: (800) 316-4515 www.emergi-lite.com 09/15 750.1586 Rev. B 4/4