Horizontal Distribution Units - HDU Multi-port

Similar documents
SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

RAY COMPACT ENERGY METER MECHANICAL

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter

Superstatic 440. Static Heat- and Cooling Meter. Application

HYDRUS ULTRASONIC METER

Automatic balancing valves ASV-PV DN (3rd gen.)

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

SonoSensor 30 Ultrasonic flow sensor

Valve bodies type RA-N with integrated presetting

Compact Static Heat Meter of High-Tech Composite

HYDRUS ULTRASONIC METER

WZMC-402 Ultrasonic Apartment Energy Meters

Pressure independent balancing and control valve

Supercal 539 Universal compact heat meter

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Flow controller (PN 25) AVQ - return and flow mounting

High Capacity Valve Body, Type RA-G

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Flow-compensated temperature controller AVTQ DN 15

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

CORONA E ELECTRONIC METER MULTI-JET

Supercal 539. Compact thermal energy meter

MULTICAL 6M2. Data sheet

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

SHARKY FS 473 ULTRASONIC FLOW SENSOR

Pressure independent balancing and control valve AB-QM DN

SonoSelect and SonoSafe energy meters

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

Manual presetting valves LENO MSV-BD

Ultrasonic heat meter

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

CORONA ER ELECTRONIC METER MULTI-JET

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Infocal 9 Energy calculator for heating and cooling applications

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

WESAN WPV E ELECTRONIC METER WOLTMAN

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Manual Presetting Valves LENO MSV-B

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Flow controller (PN 25) AVQ - return and flow mounting

Pressure independent balancing and control valve AB-QM DN

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Pressure relief controller AVA (PN 25)

Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size

tprime TM Series 280T

VE-S_15-32 Pressure Independent Balancing & Control Valves

TDU.3 floor distribution unit SK

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

GEMÜ 539 esydrive Motorized globe valve

SonoSelect and SonoSafe energy meters

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

ULTRASONIC HEAT METER

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

ON/OFF zone valves AMZ 112, AMZ 113

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Floor heating system, heating circuit with FHV-A in flow.

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Heat Meter Integrator

Differential Pressure and Flow meters Accessories for the Media Series

Actuator type ABNM with Theft Protection, 0-10 V Proportional

MULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication

GEMÜ 549 esydrive Motorized globe valve

Manual presetting valve MSV-C

X-tra Collection for designer radiators and bathroom towel rails

A 601 A B C. 1. How it works

Flow meter Type Recordall (RCDL)

Measuring capsule heat meter G54 / G55

TOPAS PMW-basic. Customer benefits. Product features

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Transcription:

Application Danfoss pre-fabricated HDU distribution units are made for distribution and measuring of waterbased heating in 2-pipe horizontal systems. A HDU is easily mounted on the apartment wall and connected to the riser. The radiators in the apartment are connected through the manifold. The unit design provides a good overview of the installation, which makes after-service easy. All Danfoss distribution units are equipped with: heat meter, for individual measuring of energy consumption. dp controller, to ensure hydraulic stability in the heating system. HDU multi-port units are wall-mounted and created for parallel radiator distribution. HDU multiport units are available with 4 or 7 manifold ports, each in two versions with left or right connection. HDU 4-port - with left connection Installation Example HDU multi-port system Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 1

Technical Data Max. temperature 90 C Max. working pressure in heating system piping before the unit 2 bar Normal required differential pressure over unit (HDU-SF) 0.26 bar* Max. differential pressure in a control loop 0.22 bar Max. static pressure 10 bar (PN10) Connection to riser (in and out) R ¾" Connection to manifold (out) ¾" Power supply (Heat Meter) A-cell battery, 3.6 VDC *At differential pressure in control loop 10 kpa at 100% AB-PM setting. Ordering HDU-SF Connection Code no. Horizontal Distribution Unit Single Flat - HDU-SF 4-port left 003L1222 Horizontal Distribution Unit Single Flat - HDU-SF 4-port right 003L1228 Horizontal Distribution Unit Single Flat - HDU-SF 7-port left 003L1225 Horizontal Distribution Unit Single Flat - HDU-SF 7-port right 003L1231 Accessories and Spare Parts Manifold port plug (10 pcs.) Capillary tube for AB-PM Filter for strainer Code no. 003L1246 003L8152 065B8248 Modules for Heat Meter M-Bus module L-Bus module (use for external radio) Communication RS232 module RS485 module Analogue output module (4-20 ma) Combined module (2 pulse inputs / 1 pulse output) Function Pulse input module (2 inputs) Pulse output module (2 outputs) Code no. 087G6027 087G6035 087G6029 087G6032 087G6034 087G6041 087G6037 087G6039 Compression Fittings Data Size Code no. For PEX tubing (in accordance with ISO 15875) For ALUPEX tubing For steel and copper tubing PN6 G ¾ internal thread PN10 G ¾ internal thread PN10 G ¾ internal thread Note! Max. flow temperature given by the tube manufacturer must not be exceeded. 16 x 2 mm 013G4156 20 x 2 mm 013G4160 20 x 2.25 mm 013G4093 20 x 2.5 mm 013G4161 16 x 2 mm 013G4186 20 x 2 mm 013G4190 20 x 2.25 mm 013G4093 20 x 2.5 mm 013G4191 16 mm 013G4126 18 mm 013G4128 2 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Design 1. Ball valve for in- and outlet connection to the riser. 2. Strainer to trap dirt, sand etc. from pipe water (replacement filter available as accessory). 3. AB-PM automatic balancing valve, combines three functions: differential pressure controller, control valve with linear characteristic and flow limiter. 4. Manifold for radiator connection, flow. 5. Manifold for radiator connection, return. 6. Automatic air vent and drainage (both inlet and outlet has drainage and air vent possibilities). 7. Heat Meter for energy measuring, with 8-digit LCD. 8. Cabinet (with lockable door). 1 1 2 3 4 5 7 8 6 6 Materials in Contact with Water 1 Shut- off valves Body, tailpiece, ball Brass Seals PTFE O-ring EPDM 2 Strainer Body Brass Filter Stainless steel O-ring EPDM 3 AB-PM valve Body, cone (CV), seat (CV) Brass Membrane, O-ring, seat (PC) EPDM Spring, cone (PC), screw Stainless steel Flat gasket NBR Sealing agent Dimethacrylate Ester Capillary tube Copper 4 & 5 Manifold Inlet adapter, shutter, manifold pipe, Euro cone connector O-rings Brass EPDM 6 Air vent & drainage Body Brass Seals EPDM 7 Heat Meter Body of flow meter Brass Temperature sensors, reflectors Measuring tube Stainless steel qp 0.6-2.5 --> PES qp 3.5-60 --> PEEK-GF or PPS-GF Other parts Assembly nipples Brass Flat gaskets Aramide fibres, NBR Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 3

Settings Q [l/h] ΔP_v ΔP_a Q = Needed design flow for the loop. Δ P_loop = Needed design Δ P for the loop. Δ P_a = available Δ P. Δ P_ V = min needed Δ P for AB-PM (starting Δ P V ) = 16 kpa ΔP_a ΔP_v + ΔP_loop ΔP_loop ΔP_loop ΔP_loop ΔP_loop Flow l/h 700 600 500 100% 90% 80% 70% 400 300 60% 50% 40% 200 100 30% 20% 0 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Δ P_loop [kpa] Δ P_loop [kpa] Flow [l/h] - average 20% 30% 40% 50% 60% 70% 80% 90% 100% 5 142 209 294 360 443 509 591 642 684 6 138 201 284 346 424 484 563 611 655 7 134 193 274 331 405 460 534 580 626 8 129 185 263 316 386 435 505 548 595 9 125 177 252 300 366 410 476 516 564 10 120 168 240 285 346 386 447 484 531 11 115 160 228 269 326 361 418 452 498 12 110 151 215 253 305 337 388 420 464 13 104 142 202 237 284 313 359 388 430 14 99 134 189 221 263 288 329 355 394 15 93 125 175 205 241 264 299 322 357 16 87 116 161 188 219 240 269 289 320 17 81 107 146 172 196 216 239 256 282 18 74 97 131 155 174 192 209 222 243 19 68 88 116 138 150 168 179 189 203 20 61 79 100 120 127 144 148 155 162 4 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Example Given: Design flow trough radiatorsloop: 450 l/h Pressure drop trough the loop at design flow: 10 kpa Solution: Set to 80 %, AB-PM will control differential pressure of 10 kpa when design flow is achieved. It will at any loads including keep it under 22 kpa at zero load, while limiting the flow to radiator system to 450 l/h. AB-PM Automatic Balancing Valve AB-PM is a combined automatic balancing valve. It features three functions in a compact valve body: 1. Differential pressure controller. 2. Control valve with linear characteristic. 3. Flow limiter. Benefits: Reliable heating system resulting in proper heat distribution even at partial loads and noise free operation based on stable low Δp over thermostatic radiator valves even in installation where higher pump head is needed. Lower heating cost. Better indoor temperature control Faster in simpler installation with less installation space needed. Technical data Nominal diameter Control valves characteristic Shut-off leakage rate CV stroke Connection Ext. thread ISO 228/1 DN20 Linear Acc. to ISO 5208 class A - no visible leakage 2.25 mm G 1 A Actuator M 30 x 1.5 Design 1. Spindle. 2. Stuffing box. 3. Pointer. 4. Control valve s cone. 5. Membrane. 6. Main spring. 7. Hollow cone (pressure controller). 8. Vulcanized seat (pressure controller). 9. Impulse tube. 5 6 7 8 9 1 2 3 4 AB-PM is a combined automatic balancing valve. It is working as Δp controller, flow limiter and zone controller. Higher pressure acts on the upper side of the control diaphragm (5) while via an impulse tube (9) lower pressure in the return pipe acts on the lower side of the diaphragm. When available pressure increases at partial loads, the membrane closes and thus keeps stable Δp inside the controlled loop. Δp controller keeps constant differential pressure on the controlled loop including the control part of AB-PM (similar as if ASV-I would be integrated into ASV-P). The control part of AB-PM is working as a flow limiter. This enables to set both the design flow as well as needed Δp. The flow rate is defined by presetting AB-PM, based on pressure demand of the loop. With actuator mounted on the valve, AB-PM can be used as zone valve. When connected to the room controller with time programs, functions such as night setback, holiday mode, etc become available. Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 5

Sonometer 1100 Heat Meter The SONOMETER 1100 is an ultrasonic static compact energy meter especially designed for heating, cooling or combined heating/cooling application in local and district energy systems. The SONOMETER 1100 as a compact energy meter consists of the following components: Ultrasonic flow sensor. Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption. Pair of temperature sensors. SONOMETER 1100 V ΔT ΔT -V GPM Heat meter Made in Germany 3030716 087G6103 Installation: high temp. S/N: 41598383 qs: 5m 3 /h Θ: 1...180 C qp: 2.5m 3 /h ΔΘ: 3...177K qi: 0.025m 3 /h Pt 500 PS/PN: 16 class 2 DN20 IP54 E1 / M1 Θq: 5...130 C P.-Year 2012 Features Complete dynamic range: 1 : 1500. Lithium battery, 230 V AC or 24 V AC mains unit. Battery lifetime 11 years (16 years optional). Unique free- beam principle. Swirl-free flow around reflector. Lower pressure loss. Robust stainless steel reflector. Insensitive to dirt. Measuring accuracy meets the requirements of EN 1434 ( MID) class 2. Special features Remote reading via M-Bus, L-Bus, RS 232, RS 485, Radio or optical interface. Individual remote reading (Automatic Meter Reading) with add on modules Plug & Play. 2 communication ports (e.g. M-Bus + M-Bus). Insensitive to presence of magnetite parts in heating water. Straight parts before and after HDU-SF are not required. History memory for 24 months. Extensive diagnostic displays. IZAR@SET parameterization software on Windows basis guarantees optimum adaptation to the user s specific needs. Software The IZAR@SET parameterization software on windows basis is a convenient tool for handling the energy meter. The IZAR@SET software is available on web site www.hydrometer.de. It is used for: commissioning reading out measured values printing out energy meter logs energy meter configuration application analysis print the meter protocol 6 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Technical Data Temperature sensors Type Pt 500 with 2-wire leads Input Supply voltage Basic features Display indication Sensor current ma Pt 500 peak < 2; rms < 0.012 Measuring cycle T s Mains unit supply: 2 (A-cell battery: 16; D-cell battery: 4) Max. temperature difference Min. temperature difference Starting temperature difference Absolute temperature measuring range Δθmax K 177 Δθmax K 3 Δθmax K 0.125 θ C 1...180 Operating voltage U N 3.6 V DC (Lithium-battery) / 230 V AC / 24 V AC Ambient class EN 1434 class E1 + M1 Protection class IP 54 Type Measuring process Display Units Static energy meter to EN 1434 (MID) Ultrasonic volume measurement LCD, 8-digit MWh - kwh - GJ - Gcal - MBtu - gal - GMP - C - F - m³ - m³/h Total values 99 999 999-9999 999.9-999 999.99-99 999.999 Values displayed Power - energy - flow rate - temperature - volume Measuring accuracy to EN 1434 Class 2 Design and Function The SONOMETER 1100 as a compact energy meter consists of the following components: Ultrasonic flow sensor. Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption. Optimized pair of temperature sensors. The calculator contains all the necessary circuits for recording the flow rate and temperature and for calculating, logging and displaying the data. The energy meter can be conveniently read from a single-line 8-digit display with units and symbols. A push-button provides user-friendly control of the various display loops. All failures and faults are recorded automatically and shown on the LC display. To protect the reading data, all the relevant data are saved in a non-volatile memory (EEPROM). This memory saves the measured values, device parameters and types of error at regular intervals. Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 7

Ultrasonic flow sensor The ultrasonic technology of the flow sensor permits very high measuring accuracy and can be used in the supply or return line. The flow sensor meets the requirements of EN 1434 / class 2. Supply voltage: Lithium battery 3.6 V DC A-cell (11 years typical lifetime). Temperature Sensors Pairs of Pt 500 temperature sensors with 2-wire leads are used. 8 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Interfaces Optical: ZVEI interface as standard, for communication and testing, M-Bus protocol. M-Bus: The M-Bus communication module is a serial interface for communication with external M-Bus control centre. The module contains a 2-pole terminal strip with terminals marked 24, 25, which are connected to M-Bus control centre. M-Bus protocol to EN 1434-3 standard. L-Bus: Adapter for external radio module; configurable telegram, according to EN1434-3. Data reading and parametrization are via two wires with polarity reversal protection. M-Bus protocol. RS232:The RS232 communication module is a serial interface for communication with external devices, e.g. PC. The module contains a 3-pole terminal strip with terminals marked 62(Dat), 63(Req) and 64(GND). A special adapter cable is required for connection. (order no. 087H0121). RS485: The RS485 communication module is a serial interface for communication with external devices, e.g. PC. The module contains a 4-pole terminal strip with terminals marked "D+", "D-", "+12V", "-12V". The module needs an external power supply of 12 V DC ±5 V. Pulse output: The module contains connections for 2 pulse outputs,, proportional to the flow or heat consumption. The module contains a 4-pole terminal strip with pulse input 1 marked as O1 - _ and input 2 as O2 - _. External supply: Vcc = 3-30 V DC. Output current < 20 ma with a residual voltage of < 0.5 V Open collector (drain) Electrically isolated Output 1: f < 4 Hz. Pulse duration: 125 ms ±10 %. Pulse break: > 125 ms 10 % Output 1: Output frequency: f < 4 Hz Pulse duration: 125 ms ±10 % Pulse break: > 125 ms 10 % Output 2: Output frequency: f < 100 Hz Pulse duration Pulse break ~1:1 Volume pulse value is configurablevia IZAR@SET software Pulse input: Module for two additional pulse counters. The module contains a 4-pole terminal strip with pulse input 1 marked as I1 - _ and input 2 as I2 - _. Pulse inputs 1 and 2 are programmable for a value of: 1, 2.5, 10, 25, 100, 250, 1000, 2500 litres per pulse. Possible units are all the energy units available in the meter, the volume unit m³ or no unit Input frequency is in the range < 8 Hz. Min. pulse duration 10 ms. Input resistance 2.2 MΩ. Terminal voltage 3 V DC. Data is accumulated separately in registers Data is readable as IN1 and IN2 in the display and can be transmitted over the communication modules Cable length up to 10 m The combined module is equipped with 2 inputs and 1 output. Combined pulse input / output:the pulse input specification is the same as that of the pulse input module above. The pulse output specification is the same as pulse output module above, but not electrically isolated. pulse duration /pulse break ~ 1:1. Configurable via IZAR@SET software. Analogue output: The module contains connections for 2 passive analogue outputs, which can be programmed as desired using the IZAR@SET software. The outputs are marked on the terminal strip as 1 and 2 with the respective polarity + and. Passive; external power supply: 10 30 V DC Current loop 4 20 ma, where 4 ma = 0 value; 20 ma = programmed max. value Overload up to 20.5 ma, then fault current Errors are generated at 3.5 ma or 22.6 ma (programmable) Output values: power, flow rate, Configurable via IZAR@SET software. Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 9

Slot 1 Analogue output module (4-20 ma). Combined module (2 pulse inputs / 1 pulse output). Pulse input module (2 inputs). M-Bus module. L-Bus module (use for external radio). RS232 module. RS485 module. Slot 2 Pulse output module. Combined module (2 pulse inputs / 1 pulse output). Pulse input module (2 inputs). M-Bus module. L-Bus module (use for external radio). RS232 module. RS485 module. Event Memory Events such as changes and faults are stored in a nonvolatile memory with a capacity of up to 127 entries. The following events are recorded: Checksum error. Temperature measurement error. Ultrasonic operating time measurement errors. Start and end of test mode. Changing of the main configuration. 10 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Monthly Memory The SONOMETER 1100 has a history memory of 24 months. The following values are stored in the EEPROM on the programmable interval (daily, weekly, monthly): Date/ Time. Cumulated energy. Tariff energy 1. Tariff energy 2. Tariff definition 1. Tariff definition 2. Cumulated volume. Error hour counter. Value of max. flow. Time max. flow. Date max. flow. Value of max. power. Time max. power. Date max. power. Pulse input counter 1. Pulse input counter 2. Pulse 1 definition. Pulse 2 definition. Operating days. Max. forward temperature. Time max. forward temperature. Date max. forward temperature. Max. return temperature. Time max. return temperature. Date max. return temperature. Log Memory The large two log memory blocks are used to store consumption values. The storage frequency can be selected from various storage intervals (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 minutes or the default setting of 24 hours, Day in the month, Day of the week, (1024 seconds), 15th or end of month). The data saved in the log memory can be used for the following analyses: Reading the calculator on a certain day. Example: If the day for reading is 01.10, the calculator reading is displayed for the period from 01.10 of the previous year to 30.09 of the current year. Comparison of the last consumption period with the preceding period. Extract of possible log memory settings Memory block Storage interval Values Date block size example Number of data records Recording period area 1 1 hour Error status, overload time temperature, overload 16 byte 556 23 days area 2 24 hours time flow rate, supply temperature, return temperature, date and time, energy, tariff energy 1, tariff energy 16 byte 299 299 days area 1 1 hour 2, tariff definition 1, tariff definition 2, volume, er- 8 byte 1113 46 days area 2 24 hours ror day counter 8 byte 599 599 days Max. Actual Values Memories The calculator creates maximum values for power, flow rate and temperatures based on consumption time, which are stored in the EEPROM. The integration intervals are adjustable to 6, 15, 30 or 60 minutes, 24 hours (and 1024 seconds). Default setting is 60 minutes. Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 11

Tariff Function The calculator offers four optional tariff memories for monitoring plant load states for limit tariffs. Extensive tariff conditions make it possible to adapt the energy meter individually to the required customer-specific applications. The following limit types are possible (this example applies to the display with 3 decimal places): Type LIMIT LIMIT resolution T 1... 255 C 1 C T R T F 1... 255 C 1 C P 1... 255 C 1 kw Q 100... 25 500 l/h 100 l/h Z 15 minutes Display Control The readings are displayed on the calculator by a 8-digit LCD with units and symbols. Loop Structure The SONOMETER 1100 display has six loops. Some display windows consist of two (to maximum seven) displays that are shown alternately at 4-second intervals. Some pictures in loops or a complete loop can be deactivated separately. For quick visual guidance, the loops in the display are numbered from 1 to 6. The main loop with the current data, e.g. for energy, volume and flow rate is programmed as default setting. Overview of Loops 12 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Informative Displays Loop Sequence Window 1 Window 2 "1" Main loop 1.1 Accumulated energy 1.2 Volume 1.3 Flow 1.4 Power 1.5 Forward temperature Return temperature 1.6 Difference temperature 1.7 Operating days 1.9 Error status 1.10 Display test Loop Sequence Window 1 Window 2 Window 3 "2" Accounting date loop 2.1 Accounting date 1 (date 1) Accounting date 1 energy 'Accd 1A' 2.2 Next accounting date 1 (date 1) Next accounting date 1 energy 'Accd 1L' 2.3 Previous accounting date 1 (date 1) Previous accounting date 1 energy 'Accd 1' 2.4 'Accd 1' Date of next accounting date 1 2.5 Accounting date 2 (date 2) Accounting date 2 energy 'Accd 2A' 2.6 Next accounting date 2 (date 2) Next accounting date 2 energy 'Accd 2L' 2.7 Previous accounting date 2 (date 2) Previous accounting date 2 energy 'Accd 2' 2.8 'Accd 2' Date of next accounting date 2 Loop Sequence Window 1 Window 2 "3" Info loop 3.1 Current date 3.2 'SEC_Adr' Secondary address 3.3 'Pri_Adr 1' Primary address 1 3.4 'Pri_Adr 2' Primary address 2 3.5 Installation position 3.6 'Port 1' No. of the mounted module at port 1 3.7 'Port 2' No. of the mounted module at port 2 3.8 Status integrated radio (Sequence will be shown only in meters with integrated radio) 3.9 No. of error hours 3.10 'F01-001' (software version) Checksum Loop "4" Pulse input loop Window 1 Window 2 Window 3 4.1 'In1' Accumulated values pulse input 1 'PPI' pulse value 1 4.2 'In2' Accumulated values pulse input 2 'PPI' pulse value 2 Loop "5" Tariff loop Sequence Sequen ce Window 1 Window 2 Window 3 Window 4 Window 5 Window 6 Window 7 The tariff loop is switched off as a standard at the heat meter or meter for cooling. Loop "6" Monthly value loop Sequen ce Window 1 Window 2 Window 3 Window 4 Window 5 Window 6 6.1 'Date last month' 6.2 'Date month - 1' 6.3 'Date month - 2'... Accumulated energy date month - 1 date month - 2...... 6.24 'Date month - 23' date month - 23 Energy Tariff 1 Tariff 2 Volume Energy Tariff 1 Tariff 2 Volume Energy Tariff 1 Tariff 2 Volume Energy Tariff 1 Tariff 2 Volume Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 13

480 266 Data Sheet Loop review A push-button mounted on the front of the calculator is used to switch to the various displays. The button can be pressed for a short or long time. A short press of the button ( < 3 seconds) switches to the next display within a loop and a long press ( > 3 seconds) switches to the next display loop. The Energy window (sequence 1.1) in the main loop is the basic display. The calculator switches automatically to power save mode if the button is not pressed for approx. 4 minutes and returns to the basic display when the button is pressed again. The loop settings can be programmed to suit the customer s individual requirements using the IZAR@SET software. Dimensions 95 62 A B 23 49 125 C D 380 51 25 50 665 685 213 113-200 120 4-port 7-port A 480 mm 630 mm B 265 mm 365 mm C 670 mm 820 mm D 715 mm 865 mm 14 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions

Danfoss Heating Solutions VDIGB102 Danfoss 08/2012 15

Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone:+45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. 16 VDIGB102 Danfoss 08/2012 Danfoss Heating Solutions