W-200-IS Specifications

Similar documents
W-300-AST Specifications

Installation & Operation Instructions For EZ Klear Systems Model EZK-25



Centro-Matic Automatic Lubrication Systems FlowMaster Hydraulic Pump


GREASE INTERCEPTORS. OPTIONS and VARIATIONS

Packaged Design Day Tank Systems

Setting the Global Standard for Quality, Durability and Reliability

GREASE ENFORCER Operation & Maintenance Manual

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

Smart controls Reliable operation User friendly design Plug and play operation

DME Valve Gate Controls

07 Oil Change & Diesel Transfer Pumps

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

TYPE PC Propeller Condensate Pumps

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

07 Oil Change & Diesel Transfer Pumps

05 Water Pressure Systems INTRODUCTION

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

MODEL CMA-44 PARTS MANUAL Rev 2.13

Climate Control Products

PROTECTOR FIBERGLASS ENCLOSURES

1BGrease Traps and. Frequently Asked Questions About Grease:

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Climas y Proyectos Leyco, S.A. de C.V.

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

GREASE INTERCEPTOR REQUIREMENTS

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

Compact LTC Oil Filtration System Manual

THE MAGNUM SUCTION SYSTEM

Mono Pumps PSS Eco 1-60

UV DISINFECTION UNIT MODEL 3G

Smart controls Reliable operation User friendly design Plug and play operation

Auxiliary Equipment. Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) Duplex Remote Pumping Unit Option #397-12B

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL



SINGLE DUCT TERMINAL UNITS

MAP Automatic Strainers In-Line Series

FireCoil. Commercial Fire Doors FireCoil

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

MLT6 Mobile Light Towers

WATER & WASTE management 2015 edition

WITH 300 CFM RECLAIM MANUAL NUMBER: 563 TABLE OF CONTENTS

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Tank Filling Systems for Petroleum Products

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

XV-JP # Silver Peak Ave. Dacono, Colorado 80514

FAN POWERED TERMINAL UNITS

MODEL 10LH SPECIFICATION

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER

PROPER ELECTRICAL CONNECTIONS

EnPak A28GBW. Only One All-In-One Stands Alone

Vacuums. Air Dryers. Decontamination Trailers. Dust Collectors. Generators. Heaters. Sandblast Pots. Spray Pumps. Steel Grit Recyclers

Industrial Generator Set Accessories

CA3000C & CA6000C Cartridge Air Cleaners

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

FreezeFree TM Nitro Anti-Icing System GENERAL SPECIFICATIONS

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

AMERICAN EAGLE COMPRESSOR AND ACCESSORIES CATALOG. Your Contact: Telephone:

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

! IMPORTANT: READ BEFORE OPERATING

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Originators of insulated poly waterers

Outdoor Enclosure Power System ENC X100MP48F20-AC6

8600 SERIES. SPACE$SAVER DOORWARE Page C SPACE$SAVER. Page C-6. PREMIER DOORWARE Page C-11 ASSURED EXCELLENCE 8200 SPACE$SAVER

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Thread Protector Cleaner (Large Capacity)

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

MARFAID Solenoid Valves

MODELS LCE/LCS, L2E/L2S, L3E/L3S

Deep Well Pump Control Valve

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Bariatric & Specialty. Closet Systems

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

Designer Series. Blanket Warming Cabinet.

Single, oversized roller compresses a low friction hose through a full 360-degrees of rotation

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Regenerative Turbine Pumps

H HD/S SERIES TECHNICAL GUIDE

ZIR36ND GE Monogram 36" Built-In All-Refrigerator

Pro Cart Ultra ELECTRIC & NON-ELECTRIC INSULATED HOLDING & TRANSPORT CABINETS

FILTERS DOUBLE LENGTH, DUPLEX DOUBLE LENGTH, SIMPLEX SINGLE LENGTH, SIMPLEX SINGLE LENGTH, DUPLEX

SPECIFICATIONS FOR MULTIMIXER PZ-CB-MM CONE BOTTOM, CENTER OUTLET

C1000 Series Automatic Cap Bank

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

Regenerative Turbine Pumps

TotalPac 3 Deluge, Electric release Remote controlled system

PRODUCT SPECIFICATION

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

MAHLE Automatic Filter Series R8-30W

Fiberglass Basins with Ballast Support Flange 24" thru 72" Dia. (.6m thru 1.8m)

Empire Finish & Reclaim Cabinets. Cabinet Models Options EFR-2636 SRC. Parts Cabinet Assembly Reclaimer Dust Bag Dust Collector Pipe String Blast Gun

Transcription:

MOTOR/TIMER ENCLOSURE Big Dipper Point Source Automatic W-200-IS Specifications 1 CLEARANCE REQUIRED FOR STRAINER BASKET & LID REMOVAL 14.75 2 PIPE / 17.5 END VIEW 19.5 GC-6 10.5 GREASE 10.5 6 QUART CAPACITY 22.5 SIDE VIEW 25.5 FEATURES: Fully automatic self cleaning cycle. Removes collected grease & oils from tank without any operator assistance. Comes complete with 24-hour timer. Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. Easy lift grease collector simplifies grease collection container emptying. TOP VIEW Compact footprint. TECHNICAL DATA Materials: Electrical: Maximum Inlet Flow Rate: Number of Skimming Wheels: Skimming Rate: Grease Retention Capacity: Internal Solids Strainer Capacity: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene 115 VAC, 60 Hz, 350 Watts (3 Amps) 20 GPM 1 35 Pounds Per Hour 40+ Pounds 1.16 Gallons 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 1

W-200-IS Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions 22.5 6 6 DO... Allow a minimum of 1 clearance for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. 7 Install vent on outlet piping. GC-6 GREASE Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controller for proper operating times. DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-200-IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 20 gallons per minute peak flow, 40 pounds of grease capacity and including as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/ oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, a hinged lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a separate grease and oils collection container. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor shall be equipped with thermal overload protection with automatically resettable switch. 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 2

MOTOR/TIMER ENCLOSURE Big Dipper Point Source Automatic W-250-IS Specifications 1 CLEARANCE REQUIRED FOR STRAINER BASKET & LID REMOVAL 14.75 2 PIPE / 17.5 END VIEW 19.5 GC-6 10.5 GREASE 10.5 6 QUART CAPACITY 25.5 SIDE VIEW 28.5 FEATURES: Fully automatic self cleaning cycle. Removes collected grease & oils from tank without any operator assistance. Comes complete with 24-hour timer. Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. Easy lift grease collector simplifies grease collection container emptying. TOP VIEW Compact footprint. TECHNICAL DATA Materials: Electrical: Maximum Inlet Flow Rate: Number of Skimming Wheels: Skimming Rate: Grease Retention Capacity: Internal Solids Strainer Capacity: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene 115 VAC, 60 Hz, 350 Watts (3 Amps) 25 GPM 1 35 Pounds Per Hour 50+ Pounds 1.16 Gallons 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 3

W-250-IS Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions 25.5 6 6 DO... Allow a minimum of 1 clearance for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. 7 Install vent on outlet piping. GC-6 GREASE Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controller for proper operating times. DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-250-IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 25 gallons per minute peak flow, 50 pounds of grease capacity and including as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/ oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, a hinged lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a separate grease and oils collection container. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor shall be equipped with thermal overload protection with automatically resettable switch. 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 4

W-350-IS Specifications MOTOR/TIMER ENCLOSURE 1 CLEARANCE REQUIRED FOR STRAINER BASKET & LID REMOVAL 17.85 3 PIPE / 17.5 END VIEW GC-6 22.6 GREASE 12.5 6 QUART CAPACITY 12.5 34. SIDE VIEW 37. FEATURES: Fully automatic self cleaning cycle. Removes collected grease & oils from tank without any operator assistance. Comes complete with 24- hour timer. Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. Easy lift grease collector simplifies grease collection container emptying. TOP VIEW Compact footprint. TECHNICAL DATA Materials: Electrical: Maximum Inlet Flow Rate: Number of Skimming Wheels: Skimming Rate: Grease Retention Capacity: Internal Solids Strainer Capacity: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene 115 VAC, 60 Hz, 350 Watts (3 Amps) 35 GPM 1 35 Pounds Per Hour 70+ Pounds 2.5 Gallons 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 5

W-350-IS Specifications INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions 34. 6 6 DO... Allow a minimum of 1 clearance for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. 7 Install vent on outlet piping. GC-6 GREASE Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controller for proper operating times. DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-350-IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 35 gallons per minute peak flow, 70 pounds of grease capacity and including as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/ oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, a hinged lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a separate grease and oils collection container. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor shall be equipped with thermal overload protection with automatically resettable switch. 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 6

W-500-IS Specifications MOTOR/TIMER ENCLOSURE 1 CLEARANCE REQUIRED FOR STRAINER BASKET & LID REMOVAL 17.85 FEATURES: 3 PIPE / 17.5 END VIEW GC-6 GREASE 22.6 12.5 6 QUART 12.5 CAPACITY 42. SIDE VIEW 45. Fully automatic self cleaning cycle. Removes collected grease & oils from tank without any operator assistance. Comes complete with 24-hour timer. Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. TOP VIEW Easy lift grease collector simplifies grease collection container emptying. Compact footprint. TECHNICAL DATA Materials: Electrical: Maximum Inlet Flow Rate: Number of Skimming Wheels: Skimming Rate: Grease Retention Capacity: Internal Solids Strainer Capacity: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene 115 VAC, 60 Hz, 350 Watts (3 Amps) 50 GPM 1 35 Pounds Per Hour 100+ Pounds 2.5 Gallons 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 7

W-500-IS Specifications 7 INSTALLATION INFORMATION Suggested Minimum Footprint Dimensions 42. 6 6 GC-6 GREASE DO... Allow a minimum of 1 clearance for removal of unit lid. READ instruction manual included with system before doing anything. Install unit allowing for the minimum clearances shown. Make sure the height above the Internal Strainer Access Cover is enough to remove the strainer. Make piping connections with rubber "No Hub" connectors. Keep outlet piping as straight as possible. Use only "sweep" connections. Install vent on outlet piping. Fill the tank with water before energizing the power to the motor and heater. Set Programmable Time Controller for proper operating times. DON'T... Install "P" trap on outlet connection of tank. (Note: the unit already has an internal gas trap). Reduce pipe size on outlet piping. Note: Installations must comply with all applicable local, state, and national codes for your area. Job Specification: Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans. Separator Specifications: Furnish and install Thermaco Big Dipper Model No. W-500-IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 50 gallons per minute peak flow, 100 pounds of grease capacity and including as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, a hinged lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a separate grease and oils collection container. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor shall be equipped with thermal overload protection with automatically resettable switch. 7/04 Thermaco, Inc. PO Box 2548 Asheboro, NC 27204-2548 Phone: (336) 629-4651 Online: www.big-dipper.com 8