XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

Similar documents
MOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 pumps

TECHNICAL INSTRUCTIONS DGP

Plastic tube variable area flowmeter for liquids and gases

Float Switch AKS 38. Technical brochure MAKING MODERN LIVING POSSIBLE

Direct drive electronic position indicators

Liquid level switch Type AKS 38

Level indicators, screw plugs

Advantages. Options VHS06

1/4 BSPP. 500 psi / 35 bar) psi / 35 bar) 8 018X XXX 03 X XXX

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Solenoid System FLANGE MOUNTING VERSION

PF6 Stainless Steel Piston Actuated On/Off Valves

Diaphragm pressure switches up to 42 V with brass housing. Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) 1) Male thread

Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) 1) Male thread

Technical explanations for mechanical pressure switches

Boiler room components 0459EN February 2018 Manual reset safety pressure switch

ROLLERS UCK T TR PALLE

LIMIT SWITCHES & POSITION INDICATION

TECHNICAL INSTRUCTIONS DGPT2

PF6 Stainless Steel Piston Actuated On/ Off Valves

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

0190 / Tolerance in psi (bar) at room temperature. Adjustment range in psi (bar) psi. ± 2.90 psi. (± 0.2 bar) (0.3-1.

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

Dimensional Drawing - Mounting Options

Technical explanations for mechanical pressure switches

Kuhnke Technical Data. Contact Details

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

HIGH PRESSURE - pumps

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Kuhnke Technical Data. Contact Details

LEVEL SWITCH WITH 1 FLOAT

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

MOUNTING BRACKETS. Dimensional Drawing - Mounting Options

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

Flow switches for insertion installation

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

SERIES G603 STANDARD FRONT MOUNT GAGE

The range of products is completed by a number of accessories, including:

PRESSURE MONITORING.

Miniature Float Switches

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE

DIN 950. Spoked handwheels. d 2. l 3. d 3. l 1. Operating elements. Cast iron / Aluminium. SPECIFICATION Types

Normalde Kapalı kontakt

EZ-View. Flow Meters ISO CERTIFIED 9001

In line high pressure filters. HF 735 series

Breathers. BF...3 & BF...4 Series INNOVATIVE FLUID POWER. ø D1 HEX. Specifications. Hydraulic Symbols. Model Code. Dimensions BF P 3 G 10 W 1.0 /.

short name: 3WL.IG* technical product sheet created :57 1/6 3-way ball valve F/F PN 63 with pneumatic actuator hard anodized aluminum

FPT Applications. Features

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

1.5. 7,250 psi Stainless steel V2A. 7,250 psi Stainless steel V2A. PUR cable type 3 IP 68 Embeddable 600 Hz Table 6 Diagram

VALVES WITH UV ELECTRIC ACTUATOR

Control valves, meters and accessories

Composite Push-In Fittings BSP/Metric Series 7000

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

BUTTERFLY VALVES + UM ELECTRIC ACTUATOR

4 variable speed submersible pumps

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

Control valves with pneumatic actuators up to 350 C PN

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Camlocks. Snaplock Camlock Couplings. The original Snaplock quick release coupling. Applications

Control Components Pty Ltd. PO Box 212 Caringbah NSW 1495 Sydney Australia ph: +61 (0) fx: +61 (0)

RUBBER SLEEVE KNIFE GATE VALVE

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

LF 3600 Push-In Fittings Range

ISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings

FLUID TRANSFER SECTION 1

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

Pneumatic cylinders Compact cylinders Series P1J

Stainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)

Series PD directly operated solenoid valves

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe with EPS Positioner

Fluid Cooling Industrial COLW Series

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

MAGNETO-INDUCTIVE POSITION DETECTORS

Series P directly operated solenoid valves

BC-VDC A TOTAL SYSTEM FOR YOUR DUST COLLECTOR DWYER INSTRUMENTS, INC. DWYER OFFERS YOU:

TURNING DISK STEEL CHAINS:

Cylinders ISO 6431 VDMA

CM5-5 A-R-A-E-AVBE F-A-A-N

Operating Instructions for Plastic Flow Meter. Model: KSK

The range of products is completed by a number of accessories, including:

Float switch For industrial applications, with temperature output Model RLS-3000

VALVES ISO 5599/1, SERIES IPV-ISV

FF Pressure Switch. Diaphragm and piston switches

EVI 5 S13 Solenoid System

3/2-way Solenoid Valve for pneumatics

Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

Suction Filter Pi 200

EQUIPMENT & ACCESSORIES

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

M. Mechanical Pressure Mechanical Pressure Switches Switches

VALVES WITH NA ELECTRIC ACTUATOR

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe

Transcription:

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline, lubricant, petroleum, solvents and most chemical agents; avoid contact with alcohol based solutions and antifreeze at high temperature. For these types of applications use the special model/cx which is made from special resin resistant to fluids containing alcohol and antifreeze. -Plastic external protection made from PA66 30% fiberglass. -The internal body of the level gauges consist of two transparent parts assembled and then sealed by ultrasonic welding process, in order to ensure a leak free seal around the body. Inside the transparent body is a white graduated sticker made from Vinile Cast to improve the view of the level. -Zinc plated M12 bolts and flanged nuts are standard (optional AISI 303 stainless steel bolts and nuts are available, Buna seals 70 durometer; maximum recommended tightening torque is 5Nm (3.7 ft lbs). -The mounting can be made externally by providing 2 threaded holes M12 on 127 mm, (tolerance ±0,3 mm); alternatively they can be secured internally through 2 plain holes 12,2 MM (±0,2 mm) using the flanged nuts. -Max working temperature 80 C (176 F). Max working pressure 1 bar (14.7 PSI), (if using on pressurized tanks contact our technical office). -REED Switch Sensor is attached to the internal transparent tube, adjustable in height according to the control requirements of the level; minimum quote positioned at about 35 mm from the center of the lower bolt. The sensor is supplied with power cable (length 30 cm/0.98 ft) and M8 male connector; On request it is possible to provide a separate connection cable of (length 250 cm /8.2 ft ) complete with female M8 connector. Possibility to apply more of level sensors positioned at different heights. -Float element made of technopolymer containing a magnetic element that activates the electric contact when it reaches the level switch sensor REED. -Standard executions: with electrical contact normally open. -Operation features: the vertical level gauge XL127- PLAST-SL in addition to allowing for a visual inspection provides an electrical signal when the float element reaches the preset minimum level, following the closure of the electrical circuit. 62

ITEMS LIST ELECTRICAL CHARACTERISTICS MIN. LEVEL REED SENSOR SWITCH Item 1 2 3 4 5 6 7 8 Description Transparent body O-Rings Flanged hecs M12 Plastic cover NBR seal Magnetic floating element Hollow bolt M12 REED sensor with M8 male connector Max. applicable voltage Switching current Power rating (ohmic load) Working temperature 3 30 Vac/dc 0,2 AMPS 6 W -10 C/+70 C (14 F/158 F) IP67 63

XL/127-PLAST-ST - VERTICAL LEVEL GAUGES 5 WITH MAX TEMPERATURE ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance are compatible with mineral oil, gasoline, lubricant, petroleum, solvents and most chemical agents; avoid contact with alcohol based solutions and antifreeze at high temperature. For these types of applications use the special model/cx which is made from special resin resistant to fluids containing alcohol and antifreeze. -Plastic external protection made from PA66 30% fiberglass. -The internal body of the level gauges consisits of two transparent parts assembled and then sealed by ultrasonic welding process, in order to ensure a leak free seal around the body. Inside the transparent body is a white graduated sticker made from Vinile Cast to improve the view of the level. -Zinc plated M12 bolts and flanged nuts are standard (optional AISI 303 stainless steel bolts and nuts are available, Buna seals 70 durometer; Maximum recommended tightening torque is 5Nm (3.7 ft lbs). -The mounting can be made externally by providing 2 threaded holes M12 on 127 mm, (tolerance ±0,3 mm); alternatively they can be secured internally through 2 plain holes 12,2 MM ( ±0,2 mm) using the flanged nuts. -Max working temperature 80 C (176 F). Max working pressure 1 bar (14.7 PSI), (if using on pressurized tanks contact our technical office). -Max temperature electrical sensor (80 C): Zinc plated bolts M12 with sensor built-in (IP65 protection degree), temperature of intervention 80 C/176 F, with DIN swivel connector. -Standard executions: XL/127-PLAST-NO (electical contact normally open) XL/127-PLAST-NC (electrical contact normally closed). -Operation features: The vertical level indicator XL/127- PLAST-ST in addition to allowing for a visual inspection provides an electrical signal when the temperature of the fluid inside the tank reaches the threshold of 80 C/176 F (in conditions of use at room temperature of around 20 C/68 F); on the model XL/127-PLAST -ST-NO the electrical circuit is closed once it reaches the specified temperature, the model XL/127-PLAST -ST-NC the electrical circuit opens when is reached the specified temperature. 64

CONTACT NO CONTACT NC ITEMS LIST ELECTRICAL DATA MAX. TEMPERATURE ELECTRICAL SENSOR Item 1 2 3 4 5 6 7 Description Transparent body O-Rings Flanged hecs M12 Plastic cover NBR seal Max temperature sensor Hollow bolt M12 Power supply Max applicable voltage Calibration Precision AC/DC NC normally closed 250 Vac 10A IP65 80 C/176 F ±5 C (data referred to a room temp. = 20 C/68 F) 65

XL/127-PLAST-SL-ST - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL SIGNAL AND MAX TEMPERATURE SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance are compatible with mineral oil, gasoline, lubricant, petroleum, solvents and most chemical agents; avoid contact with alcohol based solutions and antifreeze at high temperature. For these types of applications use our model/cx which is made from special resin resistant to fluids containing alcohol and antifreeze. -Plastic external protection made from PA66 30% fiberglass. -The internal body of the level gauges consists of two transparent parts assembled and then sealed by ultrasonic welding process, in order to ensure a leak free seal around the body. Inside the transparent body is a white graduated sticker made from Vinile Cast to improve the view of the level. -Zinc plated M12 bolts and flanged nuts are standard (optional AISI 303 stainless steel bolts and nuts are available, Buna seals 70 durometer; Maximum recommended tightening torque is 5Nm (3.7 ft lbs). -The mounting can be made externally by providing 2 threaded holes M12 on 127 mm, (tolerance ±0,3 mm); alternatively they can be secured internally through 2 plain holes 12,2 MM (±0,2 mm) using the flanged nuts. -Max working temperature 80 C (176 F). -Max working pressure 1 bar (14.7 PSI), (if using on pressurized tanks contact our technical office) -REED Switch Sensor is attached to the internal transparent tube, adjustable in height according to the control requirements of the level; minimum quote positioned at about 35 mm from the center of the lower bolt. The sensor is supplied with power cable (length 30 cm/0.98 ft) and M8 male connector; On request it is possible to provide a separate connection cable (length 250 cm/8.2 ft) complete with female M8 connector. Possibility to apply more of level sensors positioned at different heights. -Float element made of technopolymer containing a magnetic element that activates the electric contact when it reaches the level switch sensor REED. -Max temperature electrical sensor (80 C): Zinc plated bolts M12 with sensor built-in (IP65 protection degree), temperature of intervention 80 C/176 F, with DIN swivel connector. -Standard executions: XL127-PLAST-SL-ST-NO (electrical contact normally open on the temperature sensor) XL127-PLAST-SL-ST-NC (electrical contact normally closed on the temperature sensor). -Operation features: The vertical level indicator XL127- PLAST-SL-ST in addition to allowing for a visual inspection provides an electrical signal when the temperature of the fluid inside the tank reaches the threshold of 80 C (176 F), (in conditions of use at room temperature of about 20 C/68 F), and provides as well an electrical signal when the float element reaches the preset minimum level. -XL127-PLAST-SL-ST-NO: the level sensor closes the electric circuit when it reaches the pre-set minimum level; the maximum temperature sensor closes the electric circuit at the preset threshold temperature of 80 C/68 F. -XL127-PLAST-SL-ST-NC: the level sensor closes the electric circuit when it reaches the pre-set minimum level; the maximum temperature sensor opens the circuit to the preset temperature threshold of 80 C/68 F. 66

CONTACT NO CONTACT NC ELECTRICAL CHARACTERISTICS MIN. LEVEL REED SENSOR SWITCH ITEMS LIST Max. applicable voltage Switching current Power rating (ohmic load) Working temperature 3 30 Vac/dc 0,2 AMPS 6 W -10 C/+70 C (14 F/158 F) IP67 Item 1 2 3 4 5 6 7 8 9 Description Transparent body O-Rings Flanged hecs M12 Plastic cover NBR seal Max temperature sensor Hollow bolt M12 Magnetic floating element REED sensor with M8 male connector ELECTRICAL DATA MAX. TEMPERATURE ELECTRICAL SENSOR Power supply Max applicable voltage Calibration Precision AC/DC NC normally closed 250 Vac 10A IP65 80 C/176 F ±5 C (data referred to a room temp. = 20 C/68 F) 67

XLV-SL - EXTENDED VARIABLE LENGTH VERTICAL LEVEL INDICATORS WITH MIN LEVEL ELECTRICAL SIGNAL -Vertical level indicators with external aluminium guard, standard center-to-center distance 300-400-500 mm; consult our technical office for custom length. -Polyamide PA 66 black end caps, transparent Polycarbonate tube; behind the tube is a graduated contrast screen for a visual check of the fluid level. -Aluminium guard can be turned 90 degrees where necessary for side viewing. -Zinc plated M12 bolts and nuts (available on request in Stainless steel AISI 303), Buna seals 70 durometer; Max tighnening torque suggested = 5 Nm (3.7 ft lbs). -Suggested for applications with mineral oils, hydraulic fluids, diesel and fluid containing glycole. Avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibilty with other chemical agents). -The mounting can be made externally by providing 2 threaded holes M12 on the center-to-center distance, (tolerance ±0,5 mm) or they can be secured internally through 2 plain holes 12,2 MM (±0,2), using the flanged nuts. -Max working temperature 80 C/176 F (with hydraulic fluid), max pressure suggested 1 bar/14,5 PSI (for use on pressure tanks contact our technical office). -REED Switch Sensor is attached to the internal transparent tube, adjustable in height according to the customer requirements of the level; minimum quote positioned at about 50 mm from the center of the lower bolt. The sensor is supplied with power cable (length 30 cm/0.98 ft) and M8 male connector; on request it is possible to provide a separate connection cable (length cm 250/8.2 ft) complete with female M8 connector. Possibility also to apply more of level sensors positioned at different heights. -Float element made of technopolymer containing a magnetic element that activates the electric contact when it reaches the level switch sensor REED. -Standard execution: with electrical contact normally open. -Operating features: the vertical level indicator XLV-SL in addition to allowing for a visual inspection provides an electrical signal when the float element reaches the preset minimum level, following the closure of the electrical circuit. 68

ITEMS LIST ELECTRICAL CHARACTERISTICS MIN. LEVEL REED SENSOR SWITCH Item 1 2 3 4 5 6 7 8 Description Polycarbonate transparent tube O-Rings Flanged hecs M12 Alu U-shape external case NBR seal Hollow bolt M12 Magnetic floating element REED sensor with M8 male connector Max. applicable voltage Switching current Power rating (ohmic load) Working temperature 3 30 Vac/dc 0,2 AMPS 6 W -10 C/+70 C (14 F/158 F) IP67 69

XLV-ST - EXTENDED VARIABLE LENGTH VERTICAL LEVEL INDICATORS WITH MAX TEMPERATURE ELECTRICAL SIGNAL -Vertical level indicators with external aluminium guard, standard center-to-center distance 300-400-500 mm; consult our technical office for custom length. -Polyamide PA 66 black end caps, transparent Polycarbonate tube; behind the tube is a graduated contrast screen for a visual check of the fluid level. -Aluminium guard can be turned 90 degrees where necessary for side viewing -Zinc plated M12 bolts and nuts (available on request in Stainless steel AISI 303), Buna seals 70 durometer; Max tighnening torque suggested = 5 Nm (3.7 ft lbs). -Suggested for applications with mineral oils, hydraulic fluids, diesel and fluid containing glycole. Avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibilty with other chemical agents). -The mounting can be made externally by providing 2 threaded holes M12 on the center-to-center distance, (tolerance ±0,5 mm) or they can be secured internally through 2 plain holes 12,2 MM ±0,2), using the flanged nuts. -Max working temperature 80 C/176 F (with hydraulic fluid), max pressure suggested 1 bar/14,5 PSI (for use on pressure tanks contact our technical office). -Max temperature electrical sensor (80 C). Zinc plated bolts M12 with sensor built-in (IP65 protection degree), temperature of intervention 80 C/176 F, with DIN swivel connector. -Standard executions: XLV-ST-NO (electical contact normally open) XLV-ST-NC (electrical contact normally closed). -Operation features: The vertical level indicator XLV - ST in addition to allowing for a visual inspection provides an electrical signal when the temperature of the fluid inside the tank reaches the threshold of 80 C/176 F (in conditions of use at ambient temperature of about 20 C/68 F); on the model XLV -ST-NO the electrical circuit is closed once it reaches the preset temperature, the model XLV -ST-NC the electrical circuit opens once it reaches the preset temperature. 70

CONTACT NO CONTACT NC ITEMS LIST ELECTRICAL DATA MAX. TEMPERATURE ELECTRICAL SENSOR Item 1 2 3 4 5 6 7 Description Polycarbonate transparent tube O-Rings Flanged hecs M12 Alu U-shape external case NBR seal Hollow bolt M12 Max temperature sensor Power supply Max applicable voltage Calibration Precision AC/DC NC normally closed 250 Vac 10A IP65 80 C/176 F ±5 C (data referred to a room temp. = 20 C/68 F) 71

XLV-SL-ST - EXTENDED VARIABLE LENGTH VERTICAL LEVEL INDICATORS WITH MIN LEVEL SIGNAL AND MAX TEMPERATURE SIGNAL -Vertical level indicators with external aluminium guard, standard center-to-center distance 300-400-500 mm; consult our commercial/technical office for custom length. -Polyamide PA 66 black end caps, transparent Polycarbonate tube; behind the tube is a graduated contrast screen for a visual check of the fluid level. -Aluminium guard can be turned 90 degrees where necessary for side viewing. -Zinc plated M12 bolts and nuts (available on request in Stainless steel AISI 303), Buna seals 70 durometer; Max tighnening torque suggested = 5 Nm (3.7 ft lbs). -Suggested for applications with mineral oils, hydraulic fluids, diesel and fluid containing glycol.avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibility with other chemical agents). -The mounting can be made externally by providing 2 threaded holes M12 on the center-to-center distance, (tolerance ±0,5 mm) or they can be secured internally through 2 plain holes 12,2 MM (±0,2), using the flanged nuts. -Max working temperature 80 C/176 F, max pressure suggested 1 bar/14,5 PSI (for use on pressure tanks contact our technical office). -REED Switch Sensor is attached to the internal transparent tube, adjustable in height according to the control requirements of the level; minimum quote positioned at about 50 mm from the center of the lower bolt. The sensor is supplied with power cable (lenght 30 cm/0,98 ft) and M8 male connector; on request it is possible to provide a separate connection cable (length 250 mm/8.2 ft) complete with female M8 connector. Possibility to also apply more than of level sensors positioned at different heights. -Float element made of technopolymer containing a magnetic element that activates the electric contact when it reaches the level switch sensor REED. -Max temperature electrical sensor (80 C): Zinc plated bolts M12 with sensor built-in (IP65 protection degree), temperature of intervention 80 C/176 F, with DIN swivel connector. -Standard executions: XLV/SL-ST-NO (electrical contact normally open on the temperature sensor) XLV-SL-ST- NC (electrical contact normally closed on the temperature sensor). -Operation features: The vertical level indicator XLV- SL-ST in addition to allowing a visual inspection provides an electrical signal when the temperature of the fluid inside the tank reaches the threshold of 80 C, 176 F (in conditions of use at ambient temperature of about 20 C/68 F) and provides as well an electrical signal when the float element reaches the predeterminated minimum level. -XLV-SL-ST-NO: the level sensor closes the electric circuit when it reaches the pre-set minimum level; the maximum temperature sensor closes the electric circuit at the pre-set threshold temperature of 80 C/176 F. -XLV-SL-ST-NC: the level sensor closes the electric circuit when it reaches the pre-set minimum level; the maximum temperature sensor opens the circuit to the preset temperature threshold of 80 C/176 F. 72

CONTATCT NO CONTATCT NC ELECTRICAL CHARACTERISTICS MIN. LEVEL REED SENSOR SWITCH ITEMS LIST Max. applicable voltage Switching current Power rating (ohmic load) Working temperature 3 30 Vac/dc 0,2 AMPS 6 W -10 C/+70 C (14 F/158 F) IP67 Item 1 2 3 4 5 6 7 8 9 Description Polycarbonate transparent tube O-Rings Flanged hecs M12 Alu U-shape external case NBR seal Hollow bolt M12 Magnetic floating element REED sensor with male connector MAx temperature sensor ELECTRICAL DATA MAX. TEMPERATURE ELECTRICAL SENSOR Power supply Max applicable voltage Calibration Precision AC/DC NC normally closed 250 Vac 10A IP65 80 C/176 F ±5 C (data referred to a room temp. = 20 C/68 F) 73