Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

Similar documents
Starting Combinations

Quality Products, Prompt Service, Trustful Relationships.

Motor Starting Solutions Open Type Version, in Kit Form

AE 9... AE 40 Contactors NE... Contactor Relays

TAE pole Contactors

Accessories for Contactors and Contactor Relays

ADS7 AC Contactor Starters

ASL09..S 3-pole Contactors - Spring Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and Motor Starters Type CI 6-50

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Short form catalogue. Motor protection & control

ICG Switchgear Price List 2009

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Essential equipment for all your requirements

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Contactor Types CI 61-98

D509E. Manual Motor - Starters

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

AF40... AF96 3-pole contactors Technical data

AF09... AF96 3-pole contactors Accessory fitting details

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Micro Contactor MA Series

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Mini Contactors CI 4-

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

SD Series Non-Fused Load Switches

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Contactors : Wide band AC / DC operated

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Capacitor Switching Contactors Type K3...-A, K3...-K

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

ABB s new control and protection devices

Enclosed motor starters

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Open Chassis Star-Delta Starter User Guide

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Technical Information

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Technical Information

Protection Equipment

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

AF series contactors (9 2650)

Star Series Motor protection & control

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Protection Equipment. 5/2 Introduction

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

MAGNETIC MOTOR STARTERS

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Thermal overload relays Type TA Class 10

Contactors type AF1350-AF1650

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual Motor Starter MS 116. Technical Catalogue

AF series contactors (9 2650)

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Control and Load Switch Specifications Bulletin Number 194E, 194L

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

3 - Protection components Motor circuit-breakers

Technical Information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

References 4 Fuse carriers

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

What you need to know. Â Conformity to standards

Overview. Contents. Overview

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Industrial contactors CTX-1

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

For many applications

General_technical_data Series

New Dimension in Motor Protection Manual Motor Starter MS116

Power Electronics. Motor brake relay GA 9031 ministop

Transcription:

Enclosed Starters 20 Contents Motor nominal powers and current... 20/2 Panorama... 20/3 Starting of three-phase asynchronous motors... 20/4 Ordering Details Enclosed D.O.L starters - Protection by thermal O/L relay... 20/6, 20/8 Enclosed D.O.L starters, with associated manual motor starter... 20/10 Star-Delta starters - Protection by thermal O/L relay... 20/12 Star-Delta starters, with associated manual motor starter... 20/13 Reversing starters - Protection by thermal O/L relay... 20/14 Reversing starters, with associated manual motor starter... 20/16 Dimensions... 20/18 20/1

Motor Nominal Powers and Currents The currents given below concern standard, 1 500 r.p.m. 50 Hz, three-phase cage motors. These values are for your information and may vary according to the motor manufacturer and depending on the number of poles. Motor power Motor nominal current at: 380 V 415 V 440 V 500 V 600 V 660-690 V 380-400 V kw PS = hp A A A A A A 0.06 1/12 0.22 0.20 0.19 0.16 0.12 0.09 1/8 0.33 0.30 0.28 0.24 0.21 0.12 1/6 0.42 0.40 0.37 0.33 0.27 0.18 1/4 0.64 0.60 0.55 0.46 0.40 0.25 1/3 0.88 0.85 0.76 0.59 0.56 0.37 1/2 1.22 1.15 1.06 0.85 0.77 0.7 0.55 3/4 1.50 1.40 1.25 1.20 1.02 0.9 0.75 1 2.00 2.00 1.67 1.48 1.22 1.1 1.1 1.5 2.60 2.50 2.26 2.10 1.66 1.5 1.5 2 3.50 3.50 3.03 2.60 2.22 2.0 2.2 3 5.0 5.0 4.31 3.8 3.16 2.9 2.5 3.4 5.7 5.5 4.90 4.3 3.59 3.3 3 4 6.6 6.5 5.80 5.1 4.25 3.5 3.7 5 8.2 7.5 7.10 6.2 5.20 4.4 4 5.5 8.5 8.4 7.60 6.5 5.60 4.9 5 6.8 10.5 10.0 9.4 8.1 6.9 6.0 5.5 7.5 11.5 11.0 10.3 8.9 7.5 6.7 6.5 8.8 13.8 12.5 12.0 10.4 8.7 8.1 7.5 10 15.5 14.0 13.5 11.9 9.9 9.0 8 11 16.7 15.4 14.4 12.7 10.6 9.7 9 12.5 18.3 17 15.8 13.9 11.6 10.6 11 15 22.0 21 19.3 16.7 14.1 13.0 12.5 17 25.0 23 21.9 19.0 16.1 15.0 15 20 30.0 28 26.3 22.5 19.3 17.5 18.5 25 37.0 35 32.0 28.5 23.5 21.0 20 27 40 37 34.6 30.6 25.4 23 22 30 44 40 37.1 33.0 27.2 25 25 34 50 47 42.1 38.0 30.9 28 30 40 60 55 50.1 44.0 37.1 33 37 50 72 66 61.9 54.0 45.4 42 40 54 79 72 67.0 60.0 49.1 44 45 60 85 80 73.9 64.5 54.2 49 51 70 97 90 83.8 73.7 61.4 56 55 75 105 96 90.3 79.0 66.2 60 59 80 112 105 96.9 85.3 71.1 66 75 100 140 135 123 106 90.3 82 80 110 147 138 131 112 96.3 86 90 125 170 165 146 128 107.0 98 100 136 188 182 162 143 119.0 107 110 150 205 200 178 156 131.0 118 129 175 242 230 209 184 153 135 132 180 245 242 214 186 157 140 140 190 260 250 227 200 167 145 147 200 273 260 236 207 173 152 160 220 295 280 256 220 188 170 20/2 ABB Building Technologies

Enclosed Starters 20 Protection by thermal O/L relay DYA YRA WRA 3-phase motor 1 operating direction 2 operating directions Starting Direct Star-delta Direct Rated operational current (400 V) Rated operational power 37 A AC-3 30 A AC-3 37 A AC-3 18.5 kw 15 kw 18.5 kw Starter type DWA / DYA / DRA YRA WRA Thermal O/L relay TA... (order separately) Higher ratings up to 110 A with DEA type up to 170 A with YEA type up to 110 A with DEA type See "Starter Combinations" main catalogue for the higher ratings Protection by associated manual motor starter DRA D YRA DB WRA DB+BU 3-phase motor 1 operating direction 2 operating directions Starting Direct Star-delta Direct Rated operational current (400 V) Rated operational power 25 A AC-3 11 kw Starter type DRA D / DRA DB / DRA DB+BU YRA D / YRA DB / YRA DB+BU WRA D / WRA DB / WRA DB+BU Starting type MS 325... (factory mounted) D : Emergency stop by manual motor starter handle DB : Emergency stop by manual motor starter handle - Undervoltage coil DB+BU : Emergency stop by mushroom headed button - Undervoltage coil ABB Building Technologies 20/3

D.O.L. Starting of Three-Phase Asynchronous Motors General A combination starter performs the following functions: circuit isolation and short-circuit protection, motor "ON" - "OFF" control, overload protection. The isolation and short-circuit protection functions must be performed by a fuse isolator switch, a fuse switch or a circuit-breaker. Fuse ratings recommended in this document should be used. The "ON" - "OFF" control and overload protection functions are performed by a contactor and thermal O/L relay combination. Full voltage D.O.L. starting is a simple, economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current. I /I n C /C n 7 6 I = current; I n = nominal current C = torque; C n = nominal torque I 5 4 3 2 C 1 Nominal values A1011DG 0 10 30 60 80 100 Motor speed (%) 20/4 ABB Building Technologies

Star-Delta Starting of Three-Phase Asynchronous Motors 20 General On starting, the motor has to overcome the resistive torque and inertia of the driven machine. During this phase, current must remain within the limits acceptable by the mains. Inertia, resistive torque and mains are commonly fixed data. Although the type of starting reduces the inrush current as required, it also reduces the torque supplied by the motor. The result is a speed buildup time that varies according to the starting process used. Star-delta starting I /I n 7 6 5 4 3 2 1 0 C /C n C (motor) C r (resistive torque) I = current; I n = nominal current C = torque; C n = nominal torque I (delta) I (star) 10 30 60 80 100 Motor speed (%) C (motor) E0899DG Technical Data On starting: current inrush is reduced to a third of direct starting current, motor torque is reduced to a third of direct starting torque. High transient currents are commonly read during star-delta switching. Utilization During the initial starting phase ("star" connection), the resistive torque of the driven machine must remain, irrespective of speed, less than the "star" motor torque until "star-delta" switching occurs. This starting mode is therefore ideal for machines with no-load starting and little inertia: machine-tools, centrifugal compressors, wood working machines, etc. In order to prevent an over high current peak, at least 80% of nominal speed must be reached on "star-delta" switching. Precautions Motor nominal voltage in delta connection must be equal to that of the mains. Example: A motor for 380 V star-delta starting must be designed for 380 V in "delta" connection. Its usual designation is "380 V/660 V motor". The motor must be constructed with 6 terminal windings. Operation Starting is a three-stage process: 1st stage - "Star" connection Press the "On" button on the control circuit to close the KM2 "star" contactor. The KM1 "line" contactor then closes and the motor starts. Countdown of programmed starting time (normally 6 to 10 s) then begins. 2nd stage - "Star" to "delta" switching When the programmed starting time is up, the KM2 "star" contactor opens. 3rd stage - "Delta" connection After 50 ms have elapsed, the KM3 "delta" contactor closes, and the motor accelerates until it reaches nominal speed. Note: the 50 ms period elapsing between opening of the "star" contactor and closing of the "delta" contactor prevents arc short-circuits. ABB Building Technologies 20/5

D.A 9... D.A 16 Enclosed D.O.L. Starters Protection by Thermal O/L Relay DWA 9-30 SB7454C0 Ordering Details - D.O.L. Starters, Standard Voltages (230 V, 400 V) Phase to phase coil supply c/w a factory-fitted connecting strip. Enclosure Rated operational Mounted Type Order code (1) Weight version current aux. AC-3 contacts 380 V 400 V 415 V State coil to be completed with Pack. A A voltage: coil voltage code : 1 piece IP 43 9 9 1 - DWA 9-30 1SBK 140 118 R8 00 0.810 enclosure 12 12 1 - DWA 12-30 1SBK 160 118 R8 00 0.810 17 17 1 - DWA 16-30 1SBK 180 118 R8 00 0.810 IP 65 9 9 1 - DYA 9-30 1SBK 140 128 R8 00 0.810 enclosure 12 12 1 - DYA 12-30 1SBK 160 128 R8 00 0.810 17 17 1 - DYA 16-30 1SBK 180 128 R8 00 0.810 (1) Thermal O/L relay to be ordered separately, see ordering details page 20/7. Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 380... 400 400... 415 5 Phase to phase connected FPCM 14 P FI 01-A FN 7-02 CA 5-10 TA 25 DU.. E0710D Higher starter ratings: up to 37 A AC-3 (400 V) : DRA... type... page 20/8 up to 110 A AC-3 (400 V) : DEA... type... see "Starter Combinations" main catalogue 20/6 ABB Building Technologies

D.A 9... D.A 16 Enclosed D.O.L. Starters Protection by Thermal O/L Relay 20 Ordering Details - D.O.L. Starters, Other Voltages Separate coil supply : control circuit (24 V, 48 V, 110 V) to be connected when putting the starter into service. Enclosure Rated Mounted Type Order code (1) Pack. Weight version operational aux. current AC-3 contacts 380 V 400 V 415 V State coil to be completed with A A voltage: coil voltage code : piece DYA 9-30 TA 25 DU CA 5-10 SB7376C1 FW 16-12 VARS SB7386C2 SB7454C0 SB7454C0 IP 43 9 9 1 - DWA 9-30 1SBK 140 018 R8 00 1 0.850 enclosure 12 12 1 - DWA 12-30 1SBK 160 018 R8 00 1 0.850 17 17 1 - DWA 16-30 1SBK 180 018 R8 00 1 0.850 IP 65 9 9 1 - DYA 9-30 1SBK 140 028 R8 00 1 0.855 enclosure 12 12 1 - DYA 12-30 1SBK 160 028 R8 00 1 0.855 17 17 1 - DYA 16-30 1SBK 180 028 R8 00 1 0.855 (1) Thermal O/L relay to be ordered separately, see table below. Ordering Details - Thermal O/L Relays Setting range Type Order code Pack. Weight A piece 0.1 0.16 TA 25 DU 0.16 1SAZ 21 1201 R1005 1 0.150 0.16 0.25 TA 25 DU 0.25 1SAZ 21 1201 R1009 1 0.150 0.25 0.4 TA 25 DU 0.4 1SAZ 21 1201 R1013 1 0.150 0.4 0.63 TA 25 DU 0.63 1SAZ 21 1201 R1017 1 0.150 0.63 1.0 TA 25 DU 1.0 1SAZ 21 1201 R1021 1 0.150 1.0 1.4 TA 25 DU 1.4 1SAZ 21 1201 R1023 1 0.150 1.3 1.8 TA 25 DU 1.8 1SAZ 21 1201 R1025 1 0.150 1.7 2.4 TA 25 DU 2.4 1SAZ 21 1201 R1028 1 0.150 2.2 3.1 TA 25 DU 3.1 1SAZ 21 1201 R1031 1 0.150 2.8 4.0 TA 25 DU 4.0 1SAZ 21 1201 R1033 1 0.150 3.5 5.0 TA 25 DU 5.0 1SAZ 21 1201 R1035 1 0.150 4.5 6.5 TA 25 DU 6.5 1SAZ 21 1201 R1038 1 0.150 6.0 8.5 TA 25 DU 8.5 1SAZ 21 1201 R1040 1 0.150 7.5 11.0 TA 25 DU 11 1SAZ 21 1201 R1043 1 0.150 10.0 14.0 TA 25 DU 14 1SAZ 21 1201 R1045 1 0.150 13.0 19.0 TA 25 DU 19 1SAZ 21 1201 R1047 1 0.150 Ordering Details - Accessories for D.O.L. Starters Description Type Order code Pack. Weight N.O. 1-pole auxiliary contact block CA 5-10 1SBN 010010 R1010 10 0.014 N.C. 1-pole auxiliary contact block CA 5-01 1SBN 010010 R1011 10 0.014 PG 16 cable gland FPCM 14 P FPTN 372528 R0004 3 0.015 Grommets FI 01-A FPTN 472626 R0003 3 0.002 "Start" button interlocking lever BD 7 FPMP 307404 R0001 10 0.003 IP 65 sealing gasket set FN 7-02 FPTN 472619 R0001 1 0.005 piece SB7571C3 CB 5-10 LP 16 Coil voltage codes Voltage (V) Coil voltage 50-60 Hz : code : 24 1 48 3 110 4 SB7585C2 Ordering Details - D.O.L. Starters, in kit form Description Type Order code (1) Pack. Weight Empty enclosure, IP 43 FW 16-12 VARS FPTN 372630 R0050 1 0.495 C/W Start and Stop/Reset pushbuttons Empty enclosure, IP 65 FY 16-12 VARS FPTN 372630 R0051 1 0.500 C/W Start and Stop/Reset pushbuttons "Start" contact CB 5-10 1SBN 010013 R1010 1 0.012 Connecting strip LP 16 FPEP 407000 R0001 10 0.002 1) Contactor and thermal O/L relay to be ordered separately. Technical data (see A 9 A 16 contactors)... page 16/30 Dimensions... page 20/18 piece ABB Building Technologies 20/7

DRA... Enclosed D.O.L. Starters Protection by Thermal O/L Relay Ordering Details. Order the thermal O/L relay separately. Rated Power Short-circuit Type Order code Weight operat. AC-3 protection * in current 4-pole motor Type 2 co-ordination as per AC-3 50/60 Hz EN 60947-4-1 / IEC 947-4-1 380 V 380-400 V State control to be completed with Pack ing 400 V 400 V 690 V Fuses Fuses voltage the control voltage code 1 piece A kw kw am gg 26 11 15 25 50 DRA 26-30 1SBK 240 122 R8 00 2.450 32 15 18.5 32 63 DRA 30-30 1SBK 280 122 R8 00 2.560 37 18.5 22 40 80 DRA 40-30 1SBK 320 122 R8 00 2.560 TA.. E1365D SB8002C3 * For other short-circuit protection devices, please consult our co-ordination tables. DRA 26-30 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 380... 400 400... 415 0 5 phase-to-phase connected Plastic enclosure - UL 94 V2 Double insulation - IP 64 protection Higher starter ratings: up to 110 A AC-3 (400 V) : DEA... type... see "Starter Combinations" main catalogue 20/8 ABB Building Technologies

DRA... Enclosed D.O.L. Starters Protection by Thermal O/L Relay 20 Ordering details, thermal O/L relay TA 25 DU SB7386C2 Starter Setting range Type Order code Weight type in Pack ing A... A 1 piece DRA 26-30 13... 19 TA 25 DU 19 1SAZ21 1201 R1047 0.150 and 18... 25 TA 25 DU 25 1SAZ21 1201 R1051 0.150 DRA 30-30 24... 32 TA 25 DU 32 1SAZ21 1201 R1053 0.170 DRA 40-30 18... 25 TA 42 DU 25 1SAZ31 1201 R1001 0.330 22... 32 TA 42 DU 32 1SAZ31 1201 R1002 0.330 29... 42 TA 42 DU 42 1SAZ31 1201 R1003 0.330 Ordering details, contactor accessories TA 42 DU SB7587C4 SB7361S3 Description Type Order code Pack- Weight ing in Function markers (50 pieces) BA5-50 1SBN 11 0000 R1000 box 0.017 1 x "N.O." auxiliary contact block CA5-10 1SBN 01 0010 R1010 10 0.014 1 x "N.C." auxiliary contact block CA5-01 1SBN 01 0010 R1001 10 0.014 "N.O. + N.C." side-mted. contact blk. CAL5-11 1SBN 01 0020 R1011 2 0.050 1 x "N.O." impulse contact block CB5-10 1SBN 01 0013 R1010 1 0.012 1 x "N.C." impulse contact block CB5-01 1SBN 01 0013 R1001 1 0.012 Connecting strip (A 26) LP 25 FPEP 407 001 R0001 10 0.004 BA5-50 SB7603C2 CA5-10 CAL 5-11 SB7375C4 SB7571C3 SB7584C2 Ordering details, enclosure cable glands Description Type Order code Pack- Weight ing in Pg 16 / CM14P cable gland FPCM 14P FPTN 372528 R0004 3 0.013 Pg 21 / CM18P cable gland FPCM 18P FPTN 372528 R0005 3 0.015 CB5-10 LP25 Contactor technical data... page 16/30 Dimensions... page 20/18 Wiring diagrams... see "Starter combination" main catalogue ABB Building Technologies 20/9

DRA... D, DRA... DB and DRA... DB+BU Enclosed D.O.L. Starters Protection by Associated Manual Motor Starter DRA... D Ordering Details Co-ordination I q = 50 ka and operational voltage < 415 V DRA 9-30 D SB8001C3 Power range co-ordi- Setting Type Order code Weight 4-pole motor nation range in 50/60 Hz Iq = 50 ka to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece 2.2... 2.5 1 4.0... 6.3 DRA 9-30-D6.3 1SBK 140 522 R8 44 2.620 3.0... 4.0 1 6.3... 9.0 DRA 9-30-D9.0 1SBK 140 522 R8 45 2.620 5.0... 5.5 1 9.0... 12 DRA 12-30-D12.5 1SBK 160 522 R8 46 2.620 6.5... 7.5 1 12.5... 16 DRA 16-30-D16 1SBK 180 522 R8 47 2.620 8.0... 9.0 2 16.0... 20.0 DRA 26-30-D20 1SBK 240 522 R8 48 2.880 11.0 2 20.0... 25.0 DRA 26-30-D25 1SBK 240 522 R8 49 2.880 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz E1368D 220... 230 230... 240 0 must be connected to the power circuit either phase-to-phase 380... 400 400... 415 5 or phase-to-neutral (1). (1) Supply 1 HK20 auxiliary contact block for neutral breaking (see page 20/11) Plastic enclosure - UL 94 V2 - Double insulation DRA... D and DRA... DB: IP64 protection DRA... DB+BU: IP54 protection Contactor technical data... page 16/30 Dimensions... page 20/18 Wiring diagrams... see "Starter Combinations" main catalogue 20/10 ABB Building Technologies

DRA... D, DRA... DB and DRA... DB+BU Enclosed D.O.L. Starters Protection by Associated Manual Motor Starter 20 DRA... DB Ordering details With undervoltage coil (380... 415 V - 50 Hz power circuit) Co-ordination I q = 50 ka and operational voltage < 415 V DRA 16-30 DB SB8001C3 Power range Co-ordi- Setting Type Order code Weight 4-pole motor nation range in 50/60 Hz Iq=50kA to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece 2.2... 2.5 1 4.0... 6.3 DRA 9-30-DB6.3 1SBK 140 622 R8 44 2.620 3.0... 4.0 1 6.3... 9.0 DRA 9-30-DB9.0 1SBK 140 622 R8 45 2.620 5.0... 5.5 1 9.0... 12 DRA 12-30-DB12.5 1SBK 160 622 R8 46 2.620 6.5... 7.5 1 12.5... 16 DRA 16-30-DB16 1SBK 180 622 R8 47 2.620 8.0... 9.0 2 16.0... 20.0 DRA 26-30-DB20 1SBK 240 622 R8 48 2.880 11.0 2 20.0... 25.0 DRA 26-30-DB25 1SBK 240 622 R8 49 2.880 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 must be connected to a supply separate from the power circuit, or either phase-to-neutral. 380... 400 400... 415 5 phase-to-phase connected. DRA... DB+BU Ordering details With undervoltage coil (380... 415 V - 50 Hz power circuit) and emergency stop mushroom button Co-ordination I q = 50 ka and operational voltage < 415 V DRA 26-30 DB + BU SB8005C3 Power range Co-ordi- Setting Type Order code Weight 4-pole motor nation range in 50/60 Hz Iq=50kA to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece 2.2... 2.5 1 4.0... 6.3 DRA 9-30-DB6.3+BU 1SBK 140 624 R8 44 2.760 3.0... 4.0 1 6.3... 9.0 DRA 9-30-DB9.0+BU 1SBK 140 624 R8 45 2.760 5.0... 5.5 1 9.0... 12 DRA 12-30-DB12.5+BU 1SBK 160 624 R8 46 2.760 6.5... 7.5 1 12.5... 16 DRA 16-30-D16+BU 1SBK 180 624 R8 47 2.760 8.0... 9.0 2 16.0... 20.0 DRA 26-30-DB20+BU 1SBK 240 624 R8 48 3.020 11.0 2 20.0... 25.0 DRA 26-30-DB25+BU 1SBK 240 624 R8 49 3.020 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 must be connected to a supply separate from the power circuit, or or either phase-to-neutral. 380... 400 400... 415 5 phase-to-phase connected. Ordering details, manual motor starter accessories Auxiliary contacts. Left-hand side mounting, 2 blocks at most. Description Contacts Type Order code Pack- Weight ing in Simultaneous 2 - - HK-20 1SAM 101 901 R0002 10 0.031 Note: Contacts can only be added on the DRA... D version. HK-20 SB7470C2 Ordering details, enclosure cable glands Description Type Order code Pack- Weight ing in Pg 16 / CM14P cable gland FPCM 14P FPTN 372528 R0004 3 0.013 Pg 21 / CM18P cable gland FPCM 18P FPTN 372528 R0005 3 0.015 ABB Building Technologies 20/11

YRA... Enclosed Star-Delta Starters Protection by Thermal O/L Relay Ordering details Order the thermal O/L relay separately, see page 16/12 TA.. E1376D SB8002C3 Rated Power Short-circuit Type Order code Weight operat. AC-3 protection * in current 4-pole motor Type 1 co-ordination as per AC-3 50/60 Hz EN 60947-4-1 / IEC 947-4-1 380 V 380-400 V State control to be completed with Pack ing 400 V 400 V 690 V Fuses Fuses voltage the control voltage code 1 piece A kw kw am gg 15.5 7.5 5.5 16 25 YRA 9-30 1SBK 142 322 R8 00 3.020 22 11 7.5 25 35 YRA 12-30 1SBK 162 322 R8 00 3.020 30 15 11 32 50 YRA 16-30 1SBK 182 322 R8 00 3.020 * For other short-circuit protection devices, please consult our co-ordination tables. YRA 9-30 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 must be connected to a separate supply 380... 400 400... 415 or phase-to-phase 5 or phase to neutral Plastic enclosure - UL 94 V2 Double insulation - IP 64 protection Higher starter ratings: up to 72 A AC-3 (400 V) : YRA... type... see "Starter Combinations" main catalogue up to 170 A AC-3 (400 V) : YEA... type... see "Starter Combinations" main catalogue 20/12 ABB Building Technologies

YRA... D Enclosed Star-Delta Starters Protection by Thermal O/L Relay 20 Ordering details Co-ordination I q = 50 ka and operational voltage < 415 V SB8005C3 Power range Co-ordi Setting Type Order code Weight 4-pole motor nation range à compléter in 50/60 Hz Iq = 50 ka to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece YRA... D 3.0... 4.0 1 6.3... 9.0 YRA 9-30-D9.0 1SBK 142 822 R8 45 3.450 5.0... 5.5 1 9.0... 12.5 YRA 9-30-D12.5 1SBK 142 822 R8 46 3.450 6.5... 7.5 1 12.5... 16 YRA 9-30-D16 1SBK 142 822 R8 47 3.450... 11.0 1 20.0... 25.0 YRA 12-30-D25 1SBK 162 822 R8 49 3.450 YRA 9-30 DB + BU E1378D YRA... DB - With undervoltage coil (380... 415 V - 50 Hz power circuit) 3.0... 4.0 1 6.3... 9.0 YRA 9-30-DB9.0 1SBK 142 922 R8 45 3.450 5.0... 5.5 1 9.0... 12.5 YRA 9-30-DB12.5 1SBK 142 922 R8 46 3.450 6.5... 7.5 1 12.5... 16 YRA 9-30-DB16 1SBK 142 922 R8 47 3.450... 11.0 1 20.0... 25.0 YRA 12-30-DB25 1SBK 162 922 R8 49 3.450 YRA... DB+BU - With undervoltage coil (380... 415 V - 50 Hz power circuit) and emergency stop mushroom button 3.0... 4.0 1 6.3... 9.0 YRA 9-30-DB9.0+BU 1SBK 142 924 R8 45 3.580 5.0... 5.5 1 9.0... 12.5 YRA 9-30-DB12.5+BU 1SBK 142 924 R8 46 3.580 6.5... 7.5 1 12.5... 16 YRA 9-30-DB16+BU 1SBK 142 924 R8 47 3.580... 11.0 1 20.0... 25.0 YRA 12-30-DB25+BU 1SBK 162 924 R8 49 3.580 Control voltage code Voltage (V) 50 Hz (V) 60 Hz Code The YRA... DB and YRA... DB+BU 220... 230 230... 240 0 control circuit is connected 380... 400 400... 415 5 phase-to-phase (code 5 only) Plastic enclosure - UL 94 V2 - Double insulation YRA... D and YRA... DB: IP64 protection YRA... DB+BU: IP54 protection Contactor technical data... page 16/30 Dimensions... page 20/19 Wiring diagrams... see "Starter Combinations" main catalogue ABB Building Technologies 20/13

WRA... Enclosed Reversing Starters Protection by Thermal O/L Relay Ordering details. Order the thermal O/L relay separately. WRA 9-30 SB8004C3 Rated Power Short-circuit Type Order code Weight operat. AC-3 protection * in current 4-pole motor Type 2 co-ordination as per AC-3 50/60 Hz EN 60947-4-1 / IEC 947-4-1 380 V 380-400 V State control to be completed with Pack ing 400 V 400 V 690 V Fuses Fuses voltage the control voltage code 1 piece A kw kw am gg 9 4 5.5 10 25 WRA 9-30 1SBK 141 222 R8 00 2.620 12 5.5 7.5 16 32 WRA 12-30 1SBK 161 222 R8 00 2.620 17 7.5 9 20 32 WRA 16-30 1SBK 181 222 R8 00 2.620 26 11 15 25 50 WRA 26-30 1SBK 241 222 R8 00 3.170 32 15 18,5 32 63 WRA 30-30 1SBK 281 222 R8 00 3.520 37 18.5 22 40 80 WRA 40-30 1SBK 321 222 R8 00 3.520 * For other short-circuit protection devices, please consult our co-ordination tables. Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 380... 400 400... 415 0 5 phase-to-phase connected TA.. E1371D Plastic enclosure - UL 94 V2 Double insulation - IP 64 protection Higher starter ratings: up to 110 A AC-3 (400 V) : WEA... type... see "Starter Combinations" main catalogue 20/14 ABB Building Technologies

WRA... Enclosed Reversing Starters Protection by Thermal O/L Relay 20 Ordering details, thermal O/L relay TA 25 DU TA 42 DU SB7386C2 SB7361S3 Starter Setting range Type Order code Weight type in Pack ing A... A 1 piece WRA 9-30 0.1... 0.16 TA 25 DU 0.16 1SAZ 21 1201 R1005 0.150 to 0.16... 0.25 TA 25 DU 0.25 1SAZ 21 1201 R1009 0.150 WRA 30-30 0.25... 0.4 TA 25 DU 0.4 1SAZ 21 1201 R1013 0.150 0.4... 0.63 TA 25 DU 0.63 1SAZ 21 1201 R1017 0.150 0.63... 1.0 TA 25 DU 1.0 1SAZ 21 1201 R1021 0.150 1.0... 1.4 TA 25 DU 1.4 1SAZ 21 1201 R1023 0.150 1.3... 1.8 TA 25 DU 1.8 1SAZ 21 1201 R1025 0.150 1.7... 2.4 TA 25 DU 2.4 1SAZ 21 1201 R1028 0.150 2.2... 3.1 TA 25 DU 3.1 1SAZ 21 1201 R1031 0.150 2.8... 4.0 TA 25 DU 4.0 1SAZ 21 1201 R1033 0.150 3.5... 5.0 TA 25 DU 5.0 1SAZ 21 1201 R1035 0.150 4.5... 6.5 TA 25 DU 6.5 1SAZ 21 1201 R1038 0.150 6.0... 8.5 TA 25 DU 8.5 1SAZ 21 1201 R1040 0.150 7.5... 11 TA 25 DU 11 1SAZ 21 1201 R1043 0.150 10... 14 TA 25 DU 14 1SAZ 21 1201 R1045 0.150 13... 19 TA 25 DU 19 1SAZ 21 1201 R1047 0.150 18... 25 TA 25 DU 25 1SAZ 21 1201 R1051 0.150 24... 32 TA 25 DU 32 1SAZ 21 1201 R1053 0.170 WRA 40-30 18... 25 TA 42 DU 25 1SAZ 31 1201 R1001 0.330 22... 32 TA 42 DU 32 1SAZ 31 1201 R1002 0.330 29... 42 TA 42 DU 42 1SAZ 31 1201 R1003 0.330 SB7587C4 BA5-50 Ordering details, contactor accessories SB7603C2 SB7375C4 CA5-10 CAL 5-11 SB7571C3 SB7585C2 CB5-10 LP25 Description Type Order code Pack- Weight ing in Function markers (50 pieces) BA5-50 1SBN 11 0000 R1000 box 0.017 1 x "N.O." auxiliary contact block CA5-10 1SBN 01 0010 R1010 10 0.014 1 x "N.C." auxiliary contact block CA5-01 1SBN 01 0010 R1001 10 0.014 "N.O. + N.C." side-mted. contact blk. CAL5-11 1SBN 01 0020 R1011 2 0.050 1 x "N.O." impulse contact block CB5-10 1SBN 01 0013 R1010 1 0.012 1 x "N.C." impulse contact block CB5-01 1SBN 01 0013 R1001 1 0.012 Connecting strip (A 9... A 16) LP 16 FPEP 407 000 R0001 10 0.002 Connecting strip (A 26) LP 25 FPEP 407 001 R0001 10 0.004 Ordering details, enclosure cable gland Description Type Order code Pack- Weight ing in Pg 16 / CM14P cable gland FPCM 14P FPTN 372528 R0004 3 0.013 Pg 21 / CM18P cable gland FPCM 18P FPTN 372528 R0005 3 0.015 Contactor technical data... page 16/30 Dimensions... page 20/20 Schémas... see "Starter combination" main catalogue ABB Building Technologies 20/15

WRA... D, WRA... DB and WRA... DB+BU Enclosed Reversing Starters Protection by Associated Manual Motor Starter WRA... D Ordering Details Co-ordination I q = 50 ka and operational voltage < 415 V WRA 9-30 D SB8000C3 Power range co-ordi- Setting Type Order code Weight 4-pole motor nation range in 50/60 Hz Iq = 50 ka to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece 2.2... 2.5 1 4.0... 6.3 WRA 9-30-D6.3 1SBK 141 522 R8 44 3.060 3.0... 4.0 1 6.3... 9.0 WRA 9-30-D9.0 1SBK 141 522 R8 45 3.060 5.0... 5.5 1 9.0... 12 WRA 12-30-D12.5 1SBK 161 522 R8 46 3.060 6.5... 7.5 1 12.5... 16 WRA 16-30-D16 1SBK 181 522 R8 47 3.060 8.0... 9.0 2 16.0... 20.0 WRA 26-30-D20 1SBK 241 522 R8 48 3.600 11.0 2 20.0... 25.0 WRA 26-30-D25 1SBK 241 522 R8 49 3.600 Control voltage code E1374D E0000D Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 must be connected to the power circuit either phase-to-phase 380... 400 400... 415 5 or phase-to-neutral (1). (1) Supply 1 HK20 auxiliary contact block for neutral breaking (see page 20/7) Plastic enclosure - UL 94 V2 - Double insulation WRA... D and WRA... DB: IP64 protection WRA... DB+BU: IP54 protection Contactor technical data... page 16/30 Dimensions... page 20/20 Wiring diagrams... see "Starter Combinations" main catalogue 20/16 ABB Building Technologies

WRA... D, WRA... DB and WRA... DB+BU Enclosed Reversing Starters Protection by Associated Manual Motor Starter 20 WRA... DB ordering details With undervoltage coil (380... 415 V - 50 Hz power circuit) Co-ordination I q = 50 ka and operational voltage < 415 V WRA 16-30 DB SB8000C3 Power range Co-ordi- Setting Type Order code Weight 4-pole motor nation range in 50/60 Hz Iq=50kA to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece 2.2... 2.5 1 4.0... 6.3 WRA 9-30-DB6.3 1SBK 140 922 R8 44 3.060 3.0... 4.0 1 6.3... 9.0 WRA 9-30-DB9.0 1SBK 140 922 R8 45 3.060 5.0... 5.5 1 9.0... 12 WRA 12-30-DB12.5 1SBK 160 922 R8 46 3.060 6.5... 7.5 1 12.5... 16 WRA 16-30-DB16 1SBK 180 922 R8 47 3.060 8.0... 9.0 2 16.0... 20.0 WRA 26-30-DB20 1SBK 240 922 R8 48 3.600 11.0 2 20.0... 25.0 WRA 26-30-DB25 1SBK 240 922 R8 49 3.600 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 must be connected to a supply separate from the power circuit, or either phase-to-neutral. 380... 400 400... 415 5 phase-to-phase connected. WRA... DB+BU Ordering details With undervoltage coil (380... 415 V - 50 Hz power circuit) and emergency stop mushroom button Co-ordination I q = 50 ka and operational voltage < 415 V WRA 26-30 DB + BU SB8003C3 Power range Co-ordi- Setting Type Order code Weight 4-pole motor nation range in 50/60 Hz Iq=50kA to be completed 380-400-415 V State control with control Pack ing kw... kw A... A voltage voltage code 1 piece 2.2... 2.5 1 4.0... 6.3 WRA 9-30-DB6.3+BU 1SBK 140 924 R8 44 3.200 3.0... 4.0 1 6.3... 9.0 WRA 9-30-DB9.0+BU 1SBK 140 924 R8 45 3.200 5.0... 5.5 1 9.0... 12 WRA 12-30-DB12.5+BU 1SBK 160 924 R8 46 3.200 6.5... 7.5 1 12.5... 16 WRA 16-30-D16+BU 1SBK 180 924 R8 47 3.200 8.0... 9.0 2 16.0... 20.0 WRA 26-30-DB20+BU 1SBK 240 924 R8 48 3.740 11.0 2 20.0... 25.0 WRA 26-30-DB25+BU 1SBK 240 924 R8 49 3.740 Control voltage code Voltage Code Control circuit (V) 50 Hz (V) 60 Hz 220... 230 230... 240 0 must be connected to a supply separate from the power circuit, or either phase-to-neutral. 380... 400 400... 415 5 phase-to-phase connected. Ordering details, manual motor starter accessories Auxiliary contacts. Left-hand side mounting, 2 blocks at most. Description Contacts Type Order code Pack- Weight ing in Simultaneous 2 - - HK-20 1SAM 101 901 R0002 10 0.031 Note: Contacts can only be added on the WRA... D version. SB7470C2 Ordering details, enclosure cable glands HK-20 Description Type Order code Pack- Weight ing in Pg 16 / CM14P cable gland FPCM 14P FPTN 372528 R0004 3 0.013 Pg 21 / CM18P cable gland FPCM 18P FPTN 372528 R0005 3 0.015 ABB Building Technologies 20/17

D.A / DRA D / DRA DB / DRA DB+BU Enclosed D.O.L. Starters Dimensions (in mm) 2 x 5,5 198 180 Cable inlets Enclosure top Cable outlets Enclosure bottom 2 x ø 23/28.5 2 x ø 23/28.5 100 E 0457D1 128 135 7 E 0458D1 E 0459D1 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P D.A 9... D.A 16 Cable inlets Enclosure top Cable outlets Enclosure bottom 3 x ø 23/28.5 3 x ø 23/28.5 407769X1 407769X2 407769X3 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P DRA 26... DRA 40 Cable inlets Enclosure top Cable outlets Enclosure bottom 3 x ø 23/28.5 3 x ø 23/28.5 407771X1 407771X2 407771X3 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P DRA... D et DRA... DB Cable inlets Enclosure top Cable outlets Enclosure bottom 407773X1 407773X2 407773X3 3 x ø 23/28.5 3 x ø 23/28.5 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P DRA... DB + BU 20/18 ABB Building Technologies

YRA / YRA D / YRA DB / YRA DB+BU Star-Delta Starters Dimensions (in mm) 20 Cable inlets Enclosure top Cable outlets Enclosure bottom 407769X1 407769X2 407769X3 3 x ø 23/28.5 3 x ø 23/28.5 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P YRA... Cable inlets Enclosure top Cable outlets Enclosure bottom 3 x ø 23/28.5 3 x ø 23/28.5 407771X1 407771X2 407771X3 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P YRA... D et YRA... DB Cable inlets Enclosure top Cable outlets Enclosure bottom 407773X1 407773X2 407773X3 3 x ø 23/28.5 3 x ø 23/28.5 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P YRA... DB + BU ABB Building Technologies 20/19

WRA / WRA D / WRA DB / WRA DB+BU Enclosed Reversing Starters Dimensions (in mm) Cable inlets Enclosure top Cable outlets Enclosure bottom 3 x ø 23/28.5 3 x ø 23/28.5 407770X1 407770X2 407770X3 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P WRA 9-30... WRA 40-30 Cable inlets Enclosure top Cable outlets Enclosure bottom 407772X1 407772X2 407772X3 3 x ø 23/28.5 3 x ø 23/28.5 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P WRA... D et WRA... DB Cable inlets Enclosure top Cable outlets Enclosure bottom 3 x ø 23/28.5 3 x ø 23/28.5 407774X1 407774X2 407774X3 ø 23 for Pg 16 / CM 14P ø 28.5 for Pg 21 / CM 18P WRA... DB + BU 20/20 ABB Building Technologies

Notes 20 ABB Building Technologies 20/21