Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Similar documents
Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

BULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

T CLASS T FUSE BLOCKS

Installation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Circuit Breakers Naval Shipboard Use

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

I.L. 29C184A File WARNING

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

MOLDED CASE CIRCUIT BREAKERS

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Engine Generator Circuit Breakers

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

POWER TERMINAL BLOCKS

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Class H & K Fuse Holders - 250/600 Volt

A WARNING. Installation Instructions for KD, HKD, KDC, CKD, CHKD Circuit Breakers I.L. 29C092C

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Cutler-Hammer. Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N) I.L.

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

Lighting and Power Distribution Panelboards

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

N-frame Circuit Breaker

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

Magnetic Overload Relays

Design Guide for Integration of Fixed-Mount Circuit Breakers

15-I73E CAT REF.

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

14-I73E CAT REF.

Installation Instructions

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

a WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.

SECTION PANELBOARDS

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Multi-Pak Group Control

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

Open-Style Power Distribution Blocks

Types ALB-1 and NLB-1

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

www. ElectricalPartManuals. com ltciil Cutler-Hammer A WARNING

CRITO Connection technology. Double and triple T and TCC section busbars

Westinghouse Electric Corporation Distribution and Control Business Unit Electrical Components Division Pittsburgh, Pennsylvania, U.S.A.

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

WLI Medium Voltage Switchgear Renewal Parts

SERIES POWER DISTRIBUTION BLOCKS

Studded Power Feed Thru Terminal Blocks

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Youngstown Power Limit Switches

OPERATOR ADAPTER A21ABA

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

Standard Materials Bodies and covers: copper-free aluminum.

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

Instructions for the Digitrip RMS Pole and 4-Pole Trip Unit Installation and Operation with L-Frame and MOL-Frame Series C Circuit Breakers

A200 NEMA Contactors and Starters A200

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

A. Submit manufacturer's literature and technical data before starting work.

www. ElectricalPartManuals. com

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

I.L. 29C121A WARNING 1. INTRODUCTION. Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V)

Cable-Operated Disconnect Switches. Accessories

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1


RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Crane Control Class 9055

NEMA Contactors & Starters (Freedom)

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Transcription:

Circuit s FG 15-150 Amperes Description Page Type FG Three-Pole... 1 Type JG Three-Pole... 3 Type KG Three-Pole... 5 Type G Three-Pole... 7 Type MG Three-Pole... 9 Type NG Three-Pole... 11

Cutler-Hammer Dimension Sheet Page 1 Type FG Three-Pole Front View.740 (18.80) Type FG Three-Pole Circuit s FG 15-150 Amperes 1.562 (39.67).197(5.00) diameter hole.328(8.33) diameter c'bore 1.938(49.23) deep from top..344(8.74) diameter c'bore.656(16.66) deep from bottom. 4 mounting holes for.164-32 (No. 8) x 1(M4x0.7x38.10) mounting screws..188(4.78)r.750 (19.05) 1.406 (35.71) 4 (114.30).375 (9.53).375 (9.53).375 (9.53) On Off.156 R (3.96) R.450(11.43) diameter 6 holes.110(2.8) dia. x.310(7.9) deep, 2 holes accept #6(M3.5) thread cutting screws.819 (20.80) 1.031 (26.19) 4.000 (101.60) Side View.125(3.18) x.750(19.05) slots for attachment leads 2.350(59.69) R 1.765 (44.83).750 (19.05).078 (1.98).094 R (2.39) R.266 (6.76).469 (11.91).625 (15.88) 1.125 (28.58) 3.000 (76.20) 3.375 (85.73) 53.219(5.56) wide conductor with.219(5.56) diameter hole [.260 (6.60) diameter hole 175 amp] 6.000 (152.40) Trough for Attachment eads.750 (19.05).094(2.3) R (Typ.) 4-PC S..172 (4.37).016(.41).125(3.18) x.484 (12.3) deep 6 holes accept #8(M4) thread cutting screws 1.328 (33.73) 2.063 (52.40) Push to Trip 4.125 (104.78) 1.328 (33.73).687 (17.46) (25.40).344 (8.74).016 (.41) E D B A :.344(8.74) wide x.375(9.53) thick 0 taper, load end 7 taper, line end To top of clip.188 (4.78) 1.250 (31.75).078(19.81) 2.219(56.36) 2.938(74.63) 3.188(80.98) 3.375(85.73) wide 3(88.90) conductor with.219(5.56) C diameter hole [.250 (6.35) diameter hole 175 amp].313 (7.95) 2.375.188 (60.33) (4.78).469 (11.91).469 (11.91).266 (6.76).250(6.35).750(19.05).062(1.57) 1.562 (39.67).740 (18.80) Reproduced from drawings 1490D63 and 1490D67 Status Dimensions ➀ Measured.125 (3.175) above Escutcheon. ➁ Applied by breaker handle to external handle mechanism. A B C D E Force, bs.➀ On 3.07 (77.98) 2.92 (74.17) 3.96 (100.58) 3.40 (86.36) 3.33 (84.58) 14 (6.35 kgs.) Tripped 2.65 (67.31) 2.57 (65.28) 4.06 (103.12) 2.99 (75.94) 2.98 (75.69) 4➁ (1.81 kgs.) Off 2.08 (52.83) 2.14 (54.36) 4.12 (104.65) 2.42 (61.47) 2.56 (65.02) 16 (7.26 kgs.) Reset 1.98 (50.29) 2.05 (52.07) 4.11 (104.39) 2.30 (58.42) 2.48 (63.10) 21 (9.53 kgs.)

Page 2 Circuit s, FG Type FG Three-Pole Front Cover Cutout Drilling Plans Front Connected Rear Connected.250(6.35) R.750(19.05).469 (11.91) 2.313 (58.75) 2.906 (73.81) 2 (73.03) 3.156 (80.16) 1.906 (48.41) 1.189 (30.20).594 (15.10).581 (14.76) 4 (114.30) 5.063 (128.60).188(4.78) ocation of diameter megger holes, if required.688 (17.48).164-32(M4 x 0.7) tap, 4 holes (69.85).438(11.13) diameter holes for 15 to 100 amp.563(14.30) diameter holes for 125 to 150 amp Reproduced from drawings 1490D63 and 1490D67 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. 15220 Printed in U.S.A.

Cutler-Hammer Dimension Sheet Page 3 Type JG Three-Pole Circuit s JG 175-250 Amperes Type JG Three-Pole Front View.188 R (4.78) R.781 (19.84).031 (.79) 4.125 (104.78) (69.85).688 (17.46).688 (17.46).281 (7.14) Dia. 4 Mtg. Holes Dia. C'Bores Side View 4.062 (103.17) 3.812 (96.82).812 (20.62).625 (15.88) 2.594 (65.89) 2.844 (72.24) 1.031 (26.19) 1.484 (37.69) 10.000 (254.00) 8.344 (184.15) 7.250 (211.94).110 (2.79) Dia. 6 Holes.250 R (6.35) R ON/ OFF/.125 (3.18) 4.000 (101.60) 3.750 (95.25).250 (6.35) (22.23) 7.531 (191.29) 15 5 RESET ON 5.50 3 OFF TRIP.035 (.89) 1.062 (26.97).156 (3.96) 5.797 (147.24) C Typical 3-Pole Thermal-Magnetic Trip Unit.469 (11.91).031 (.79) (22.23).188 (4.78).688 (17.46) Dia. 6 Holes 3.832 4.062 (97.33) (103.17) 4.312 (109.52) 4.942 Max (125.81) Max.062(1.57).625(15.88).812(20.62) 2.125 (53.98) Front Connected Terminals Catalog Cable Amp Wire Torque Number Rating Size T250KB Cu Single 70-250 #4 to 350 MCM 180 b-in (20.3 Nm) TA250KB Cu-Al Single 70-250 #4 to 350 MCM 275 b-in (31.1 Nm) 9.38 (23.83) Reproduced from drawings 1491D63 and 1491D67 (25.40)

Page 4 Circuit s, JG Type JG Three-Pole Drilling Plans.688 (17.46) (69.85).563 R (14.29) R (69.85).750 (19.05).344 R (8.74) R 1.562 (39.67).781 (19.84) 7.250 (184.15) 4.078 (103.58) C Mounting.250-20 (M6X1) Tap 4 Holes C Shown in OFF Position 8.094 (205.59) 4.891 (124.23) C Rear Connecting Studs.625 (15.88) Dia 6 Holes C Omit 2 Center Holes for 2-Pole s.813 (20.64) 4.891 (124.23) 8.094 (205.59).563 R (14.29) R.813 (20.64) C Drawout Support Blocks.375 (9.53) C.438 (11.13) Dia. 4 Holes.250 (6.35).688(17.46).718 (18.24).188 R (4.78) R 3 Megger Holes If Required 3.938 (100.03) Front Cover Cutout C 2.922 (74.22) (22.23) C 3.328 (84.53) (69.85) 3 (88.90) (44.45) 3.094 (78.59) 1.812 (46.04) 3.625 (92.08) 2.250 (57.15) 1.125(28.58) Mounting Holes Use.250-20 (M6X1) X 2 (73.025) Pan Head Screw With Sems. Tightening Torque 65 b-in (7.34) Nm. Dia..281 (7.14) Dia. 2.375 (60.33).147 (3.73) 8 Holes Deep to Accept #8 Thread Cutting Screws 4.813 (122.25).375 (9.53) C of ON/ Contact Position Indicators Red-ON Green-OFF White-TRIP.312 (7.29) Dia..375(9.53).750(19.05) OFF/ C A B D Reproduced from drawings 1491D65 and 1491D67 E F Dimension Status A B C D E F Hdl. Oper. Force On 5.24 (132.10) 5.12 (130.05) 5.54 (140.72) 5.49 (139.45) 4.77 (121.56) 4.72 (119.89) 32 b. (142.3 Nm) Tripped 4.79 (121.67) 4.71 (119.63) 5.10 (129.54) 5.10 (129.54) 4.87 (123.70) 4.85 (123.19) Off 4.02 (102.11) 4.06 (103.12) 4.33 (109.82) 4.45 (113.03) 4.91 (124.71) 4.95 (125.73) 22 b. (97.9 Nm) Reset 3.91 (99.31) 3.96 (100.58) 4.21 (106.93) 4.36 (110.74) 4.90 (124.46) 4.95 (125.73) 38 b. (169.0 Nm) Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. 15220 Printed in U.S.A.

Cutler-Hammer Dimension Sheet Page 5 Type KG Three-Pole Circuit s KG 300-400 Amperes Type KG Three-Pole Front View.625 (15.88) 6 Holes 5.490(139.43) 3.438 (87.32).110 (2.79) Dia. x.297 (7.54) Deep, 4 Holes Accept #6 (M3) Thread Cutting Screws Side View 4.313 (109.55).844 (21.44) 7.406 (112.70) 1.250 (31.75) 4.437 (65.10) 2.563 3.75 (9.52).375 (9.52) Contact Position Indicators Red/1 - On Green/O - Off White - Trip.250 R (6.35) R.063 (1.60).093 R (2.36) R.750 (19.05).860 (21.84) 2.063 (52.39) 4.125 (104.78) 2.391 (60.73) 1.219 (30.96) (41.28).188 (4.77) R ON 2.438 (61.89) OFF (41.28).125 (3.18) 4.000 (101.60) 3.563 (90.50) 2.813 (71.45).250 (6.35).625 (15.88) 8.438 (214.33) 8 (225.43) 10.125 (257.18) Trough for Attachment eads.188 (4.77) Dia. C'Bore x.031 (.79) DP.147 (12.7) Dia. Hole x DP to Accept #8 (M4) Thread Cutting Screws (8 Places).125 (3.18) Wide x.750 (19.05) Slots for Attachment eads C D C B A 3 R (98.42) R 3.813 (96.85).062 (1.57) 1.063 (27.00).188 (4.77) 1.734 (44.04).694 (17.63) (25.40) 43.209 (5.31) 5.000(127.00) 39 5.766(146.46) 5.966(151.54).188 R (4.77) R 4.782(121.46).547.698 (13.89) (17.73) 1.160 (29.49).937 (23.80) Dimensions for Extended Terminals and Barrier Style Nos. 4212B60G02, 4212B61G02 and 1492D24H01 (22.25).438 (11.13).063 (1.60).250 (6.35) R.281 (7.14) Dia. Mounting Holes 4 Holes for.250-20 (M6) x 1.50 (38) Mounting Screws Dia. C'Bore from Top 2 (73.03) Deep 2.625 (66.68) Deep.438 (11.13) Dia C'Bore.750 (10.05) Deep from Bottom 4.062 (103.17) E F.062 (1.57) 3.812 (96.82).188 (4.77) 1.063 (27.00).750 (19.05) Wide Conductor with.391 (9.93) Dia Hole ine and 2.375 (60.33) Dimensions Status A B C D E F Force➀ On 5.39 5.20 5.69 5.61 4.72 4.77 30 lbs. (136.9) (132.1) (144.5) (142.5) (119.9) (121.2) (13.61 kgs.) Tripped 4.77 4.69 5.08 5.11 4.89 4.89 (121.2) (119.1) (129.0) (129.8) (124.2) (124.2) Off 4.16 4.21 4.46 4.64 4.95 4.91 25 lbs. (105.7) (106.9) (113.3) (117.9) (125.7) (124.7) (11.34 kgs.) Reset 4.07 4.14 4.57 4.56 4.95 4.90 35 lbs. (103.4) (105.2) (116.1) (115.8) (125.7) (124.5) (15.87 kgs.).766 (19.46) ➀ All handle forces measured approximately 0.125 (3.17) from top of handle. Reproduced from drawings 1492D64 and 1492D68

Page 6 Circuit s, KG Type KG Three-Pole Rear Connected Studs Front Connected Terminals Front Cover Cutout.844 (21.44).344 R (8.74) R (22.23) Dia. (6 Places) (Omit 2 Center Holes for 2-Pole) C 5.141 (130.58) 8 (225.42) C 4.922 (125.02) 8.438 (214.33).188 R (4.77) R C.828 (21.03) 3.750 (95.25) 1.640 (41.66) 1.250 (31.75) 3.734 (94.84).250-20 (M6) 4 Holes.859 (21.83) 3.516 (89.31) 2.625 (66.68) 4.782 (121.46) 1.313 (33.34) 2.391 (60.73) R (22.22) R ON OFF.562 (14.27) C (25.39).625 (15.87).625 (15.87) (25.39) 3.734 (94.82) 5.141 (130.62) 8 (225.34) 5.953 (151.15) 10 (206.60).313 (7.93).625 (15.87) (43.64) 3.438 (87.28) (43.64).859 (21.82) 5.141 (130.52) 8 (130.22) 3.734 (94.32).688 (17.46) 3.375(85.69) 5.250(133.30) 9.688(245.97) 3.375(85.69).281 R (7.14) R.438 (11.11) Dia. 4 Holes for.312 (7.92) Mtg. Bolts 3.438 (112.67) (43.64) Reproduced from drawings 1492D63 and 1492D67 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. 15220 Printed in U.S.A.

Cutler-Hammer Dimension Sheet Page 7 Type G Three-Pole Circuit s G 450-600 Amperes Type G Three-Pole Front View Side View.250 (6.35.) 20 Tap.406 (10.31) (6) Holes.313 (7.93) 4.125 (104.73) 2.063 (52.37).125 (3.17).313 (7.93) Deep Accepts #6 Thread Cutting (22.22).438 (11.11) 5 4.313 (109.49) 3.813 (96.80).906 (23.01) Saf-T-Vue Cover When Included.531 (13.49) 1 (47.61) 5.250 (133.30) 3.375 (85.69) 1.156 (29.36) 1.125 (28.56) 2.375 (60.30) 5.063 (1.59) 9.531 (242.00) 3.031 (76.96) ON 5.625 (142.82) 10.750 (272.94) 6.844 (173.76) 13.094 (332.45) 1 Automatic Tripped 2.781 (70.62) 19 30 ON 3.375 (85.69) R 2.000.063 (51.18) (1.59) 1 (47.61) 45 1.188 (30.15) (44.43) 5.094 (78.55) 9.594 (243.59) 3.156 (80.14) 4.469 (113.46) MAGNETIC TRIP OFF PUSH TO TRIP Test Points RATING PUG 5.625 (142.82) 6.250 (158.69) 15 Reset Max 11 30 OFF.250 (6.35).094 (2.38) Rod 1.219 (30.94).063 (1.59) 45.594 (15.08) (44.43) 4 (114.26).313 (7.93).063 (1.59) 4.125 (104.73) 1.219 (30.94) 8.250 (209.47) 2.438 (61.89) 1.781 (46.23).313 (7.93) Mounting Holes.531 (131.49) Counterbore (4 Holes).891 (22.61).438 (11.11) Thick 1 Taper Both Sides 1.563 (39.67) Wide.531 (13.49) 2.531 (64.27) 4.063 (103.15) 1.125 (28.56).938 (23.80).688 (17.46) 1.156 (29.36) (22.22) 4.000 (101.60) 8.000 (203.52) 5 Current Carrying Parts Omitted From Center Pole for 2-Pole Reproduced from drawing 2608D92

Page 8 Circuit s, G Type G Three-Pole Drilling Plans For Mounting Bolts (Front Connected Terminals) For Rear Connected Studs (Insulated Panel) For Plug-In Block Front Cover Cutout.250 (6.35) 20 Tap.313 (7.93) (4 Holes) C of 5.063 (128.54) 9.531 (242.00) 4.469 (113.46) 5 C of 5.094 (129.33) 4 (114.26) 9.549 (242.54) 1.063 (26.98) Hole for 300 to 600 6 Holes for 3-Pole 4 Holes for 2-Pole Omit 2 Center Holes for 2-Pole 1.188 (30.15) Radius 5 C of Studs C of C of (44.43) 1.125 (28.56) 5.094 (129.33) 4 (114.26) 9.594 (243.59) 11.844 (300.71) Cutout for Saf T Vue Cover (If required) 1.969 (49.99) (44.43) 1.969 (49.99) 7.750 (190.43) 3 (123.78) 2.625 (66.65) C of C of.250 (6.35) (44.43) 2.000 (50.78) 4 (114.26) C of C of (25.39) C of Studs 1.125 (28.56) (6 Holes) for.375 (9.52) Mounting Bolts ocation for.313 (7.93) Megger Holes (If required) (4443.) 7.000 (177.73) Rear Connected Studs.438 (11.11) A Plug-In- Adapter Kit Terminal Arrangements Copper Cable Only (Must be Ordered Separately) Cat. #TA600A Wire Size (2) 250-500 MCM Optional A/CU Cable (Must be Ordered Separately) Cat. #TA600A Wire Size (2) 250-500 MCM Do Not Use More Than 25 Ft. bs. Torque to Tighten Nuts Do not Use More Than 25 Ft. bs. Torque to Tighten Nuts Ampere Style Thread Dimension Rating Number Size A 300 to 600 314C960G07 1-12 5 15 / 32 300 to 600 314C960G08 1-12 7 31 / 32 300 to 600 314C960G09 1-12 10 15 / 32 Poles Ampere Kit Style Thread Rating Number Size 2 300 to 600 313C644G50 1-12 3 300 to 600 313C644G51 1-12 Reproduced from drawing 2608D93 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. 15220 Printed in U.S.A.

Cutler-Hammer Dimension Sheet Page 9 Type MG Three-Pole Front View Type MG Three-Pole Side View Circuit s MG 700-800 Amperes.344 (8.73) Mounting Hole.703 (17.85) Counterbore (4) Holes 5-13 Tap Removable oad End Terminal Cover Clearance to Arc Barrier 3.094 (78.55) 1.031(26.18).734(18.65).719(18.25) 1.313(33.32).531(13.49).250(6.35) See Figures 1, 2 and Table 2.797 (71.01) 3.00 (76.17) 16.000(406.24) 9.250(234.86) 14.750(374.50) 8.625(218.99) 1 (47.61) 8.125 (206.29) 13.750 (349.11) 19.5 On - 13 Tap 1 Auto Trip 3 R (98.39) R.594(15.08) 2.188 (55.54).766(19.44) 7.000 1.125(28.56) (177.73).406(10.31) 11.406(10.31) Minimum (291.99) B 5.750(145.99) Test Points 3.750 (95.21) 3.063 (77.76) 2.797 (71.01) 15 Reset Maximum 11.5 Off.438 (11.11) Thick 1 Taper Each Side 30.594(15.08).344(8.73) 4 1.125(28.56) (114.26) Terminal Block Assembly Used Only on Ground Fault s.703(17.85) 1.188(30.15) 1.031 (26.18) 2.125 (53.95) 8.250(209.47) 5 3.063 (77.76) 1.531 (38.88) 4.125(104.73) 1.781(45.23).891(22.61) 1.125(28.56) 2.375 (60.30) Removable oad End Terminal Cover 3.813(96.80) 4.063(103.15) 4(123.78) 6.063(153.93) 1.125(28.56).531(13.49).734(18.65) 1.031(26.18) Forces (From End of ) On 50 lbs. (22.68 kgs.) Off 24 lbs. (10.89 kgs.) Reset 60 lbs. (27.22 kgs.) (22.22) 2.250(57.13) 3.000 (76.17) 8.750 (222.16) 6.375 (161.86) 3.375 (85.69) 2.625 (66.65) Current Carrying Parts are Omitted From Center Pole for 2 Pole Reproduced from drawing 2605D21

Page 10 Circuit s, Type MG Three-Pole MG 700-800 Amperes For Mounting Block (Front Connected Terminals) C of C of 8.625 (218.99) 6.125 (155.51) 14.750 (374.50) For Rear Connected Studs 5 C of C of 7.00 (177.73) 11 (291.99) 4 (114.26) For Plug-In Adapter Kit (25.39) 8.250 (209.47) C of 5 7.000 (177.73) C of 11 (291.99) 14.750 (374.50) 4 (114.26) 6.016 (25.79) Front Cover Cutout (6)Holes for.375(9.52) MountingBolts.250(6.35) Radius 1.969 (24.60) 2.078 (52.76) 3.250 (82.52).188(4.76) Radius C of 3 (88.87) 7.000 (117.73) C of.375(9.52) (4)Holes.813(20.63)Hole for 250Ampsto400Amps 6 Holes for 3 Pole 4 Holes for 2 Pole 1.063 (26.98) Radius 1.063(26.98)Hole for 450Ampsto600Amps Omit 2 Center Holes for 2 Pole 1.188(30.15)Hole for 700Ampsto800Amps Front Connected Terminals (Must be Ordered Separately) Amp Catalog Wire Size Rating Number Number of Cables For Al/Cu Cable 600 TA700MA1 (2) #1-500 MCM 800 TA800MA2 (3) 3/0-400 MCM For Copper Cable 600 T600MA1 (2) 2/0-500 MCM 800 T800MA1 (3) 3/0-300 MCM Rear Connected Studs 2 Required Per Pole (Not Supplied With ) Stud Ampere Stud Style Thread Dimension Rating Number Size A 250-400 314C960G04 3 / 4-16 5 29 / 32 250-400 314C960G05 3 / 4-16 8 13 / 32 250-400 314C960G06 3 / 4-16 10 29 / 32 450-600 314C960G07 1-12 5 29 / 32 450-600 314C960G08 1-12 8 13 / 32 450-600 314C960G09 1-12 10 29 / 32 700-800 314C960G10 1 1 / 8-12 5 29 / 32 700-800 314C960G11 1 1 / 8-12 8 13 / 32 700-800 314C960G12 1 1 / 8-12 10 29 / 32 Plug-In Adapter Kit 1 Kit Per (Not Supplied With ) Poles Ampere Kit Style Thread Fig. Rating Number Size 2 125-600 313C644G27 1 1 / 8-12 1 3 125-600 313C644G28 1 1 / 8-12 1 2 700-800 313C544G01 1 1 / 8-12 2 3 700-800 313C544G02 1 1 / 8-12 2.313 (7.93) (22.22) Panel.313 (7.93) GROUND FAUT TRIP TIME IN SECONDS PICK UP AMPERES MAGNETIC TRIP PUSH TO TRIP RATING PUG 1.906 (48.40) BREAKER TEST GROUND FAUT TEST.453 (11.50) Nameplate (Used With Ground Fault Trip) Reproduced from drawing 260D521.656 (16.66).656 (16.66).438 (11.11) A Figure 1 Do Not Use More Than 25 Ft. bs. Torque To Tighten Nuts Figure 2 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. 15220 Printed in U.S.A.

Cutler-Hammer Dimension Sheet Page 11 Type NG Three-Pole Circuit s NG 900-1200 Amperes Type NG Three-Pole Front View Side View Bolted Rear Connected Studs 4.125 (104.73) 1.063 (26.98).531 (13.49) 8.250 (209.47) - 13 Tap Removable Terminal Cover.703 (17.85) 7.188 (182.49) 6.000 (152.34) 5 1.156 (29.36).359 (9.12).734 (18.65) 1.438 (36.50).594 D (15.08) D.344 D (8.73) D 1 Inch Thick (Minimum) Insulated Panel 0.031 (0.79) 2.797 (71.01) 2.313 (58.71) 5 6.188 (157.10) 16.000(406.24) 9.250(234.86) 14.750(374.50) 8.625(218.99) B 5.625(142.82) Terminal Block Assembly Used Only On Ground Fault s 5 3.063 (77.76) 1.531 (38.88).703 (17.85) 1(47.61) 8.125 (206.29) 3.750 (95.21) 13.750 (349.11) 3.063 (77.76) 2.797 (71.01) 19 30' On 15 Reset Maximum 11 30' Off Removable Terminal Cover 1 Auto. Trip.438(11.11) Wide 1 Taper on Each Side.063 (1.59).156 (3.97).531 (13.49) 3.344 (84.90) 0.063 (1.59) 3.844 R (97.59) R 0.156 (3.97) 5.188 (131.71).719 (18.25) 1.156 (29.36) C of 1.156 0.703 (29.36) (17.85) 1.422 (36.10) 1.094 (78.55) 7.000 (177.73) 2.313 (58.71) 11 (291.99) Outside Poles (Stud Style Number 373B375G04) 1.250(31.74)- 12 Threads Center Pole (Stud Style Number 373B375G03) Omit for 2-Pole 10.50 (266.60) 1.188 (30.15) Front Connected Terminals (Must be Ordered Separately) 2.125 (53.95).531 (13.49) Current Carrying Parts are Omitted From Center Pole for 2-Pole 1.016 (25.79) 1.125 (28.56) 2.250 (57.13) 2.031 (51.57) Amp Catalog Wire Size Rating Number Number of Cables For Al/Cu Cable 1000 TA1000NB1 (3) 3/0-400 MCM 1200 TA1200NB1 (4) 4/0-500 MCM B 2 Terminal Unit 13 / 16 3 Terminal Unit 1 9 / 16

Page 12 Circuit s, Type NG Three-Pole NG 900-1200 Amperes Drilling Plans For Mounting Bolts For Rear Connected Studs (Insulated Panel) Front Cover Cutout 0.375(9.52) Dia. (4) Holes or.313(7.93)- 18 Tap C of 8.625 (218.99) 14.750 (374.50) Omit Holes in Center Pole for 2-Pole C of 5.000 7.000 (177.73) 11 (291.99) 1.969 (49.99) 6.016 2.078 (152.74) (52.76) 3.250 (82.52) C of 0.250 R (6.35 R) C of 0.188 R (4.76 R) C of Amp Rating C of Hole Dia. 3 (88.87) 7.000 (203.12) 700-800 1 3 / 16 900-1200 1 5 / 16 Cutler-Hammer & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. 15220 Printed in U.S.A.