Introducing the SCIEX Triple Quad and QTRAP LC-MS/MS System with optional SelexION + Technology

Similar documents
> Boosting the performance of LC/MS/MS analysis of mycotoxins and their transformation products by use of innovative separation techniques

SUPPRESSION IN ANALYSIS OF ARTIFICIAL SWEETENERS WITH

A Rapid imethodtm Test for Analysis of Acid Herbicides in Water

Rapid Determination of 54 Kinds of Pesticide Residues in Vegetables by PTV-GC-MS/MS

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Analysis of Perfluorinated Alkyl Acids Specified in EPA M537 and Beyond in Drinking Water Using Triple Quadrupole LC/MS/MS System.

From Patient to Plate

Pipetted Liquid Sampling. Automated sample preparation platform for online LC-MS/MS bioanalysis

Validation Report 13

Quantify with confidence and screen for the unexpected

Validation Report 25

DOCUMENT NUMBER JSM0269. TEST GUIDELINE EPA OPPTS Guideline AUTHOR Stephen Brewin. STUDY COMPLETION DATE October 4, 2012

Hitachi High-Speed Amino Acid Analyzer

Come spingere al limite le misure degli ormoni steroidei per LC-MS/MS.

Perfluorinated compounds by LC MS

Validation Report 11

DART-AB Sciex Interface Manual

Oil Free Vacuum Pumps for Mass Spectrometry

Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique

Validation Report 21

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

n multi-residue analysis of pesticides olfgang Schwack, Claudia Oellig niversity of Hohenheim

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

SI-200-GIST. DART AB Sciex Interface Manual User Manual. IonSense Inc. 999 Broadway Suite 404 Saugus, MA Manual Revision 2 Document # 7.5.

Particle Sensor Performance & Durability for OBD Applications & Beyond

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

APPLICATION TN Quantitative Analysis of Cocaine Metabolites and Adulterants in Oral Fluid

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)

Analysis of Per/Polyfluoroalkyl Substances in Water Using an Agilent 6470 Triple Quadrupole LC/MS

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

BIAcore: Real-Time Biomolecule Interaction Analysis

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

Application. Gas Chromatography June 1995

breakthrough versatility

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

A Single Method for the Direct Determination of Total Glycerols in All Biodiesels Using Liquid Chromatography and Charged Aerosol Detection

Validation Report 12

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Set Your Sights on Superior Performance

High Recovery Method of HybridSPE - Phospholipid for Cleanup of Biological Samples Prior to LC-MS Analysis

GC Method Compliance and Large Valve Oven Application

Lean Automation (Integrated Electrical and Hydraulic) Machinery Health. Proportional Directional Valves. LifeSense Hose

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Phase Technology PPA-70Xi Pour Point Analyzer

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Eddy current sensors eddyncdt

Application Note. Abstract. Authors. Environmental Analysis

built for the next generation Cat

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

PowerTRONIC 2.0 PLUG-IN PERFORMANCE ECU

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

IFPAC 2003 Dr. Berthold Andres

Set Your Sights on Superior Performance

Technical Overview. Introduction

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Determination of Pesticides in Grapes, Baby Food and Wheat Flour by Automated Online Sample Preparation LC-MS/MS

Application Note. Authors. Abstract. Energy & Chemicals

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Citi's 2016 Car of the Future Symposium

Large Volume Injection (LVI) for GC:

REAL-TIME OIL CONSUMPTION MEASUREMENT

SIMOTICS Active Magnetic Bearing Technology

TRACE ELEMENTS IN URINE. Event #3, 2012

Phase Technology CPA-70Xi Cloud Point Analyzer

TSHR 6000 series TN/TS/TX analyzer

Dassault Systèmes Automotive Powertrain Assembly Analysis with Abaqus

FEATURE ARTICLE. Advanced Function Analyzers: Real-time Measurement of Particulate Matter Using Flame Ionization Detectors. Hirokazu Fukushima

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

DANI Transformer Oil Gas Analyzer

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Remote Process Analysis for Process Analysis and Optimization

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

S-PRO 3200 GC System for Sulfur Analysis

Particle Sensor Performance & Durability for OBD Applications & Beyond

Beverage Grade Carbon Dioxide

Hot Runners and Temperature Controllers

Improve quality, reduce scrap & determine machine efficiency

GXSeries. User Guide DANGER

TRACE ELEMENTS IN WHOLE BLOOD. Event #2, 2010

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

QuaSAR Quantitative Statistics

Transcription:

RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures Introducing the SCIEX Triple Quad and QTRAP 6500 + LC-MS/MS System with optional SelexION + Technology SCIEX, Concord, Ontario (Canada)

Our Best Triple Quad Just Got Better the Most Sensitive and Fastest SCIEX Triple Quad System The New SCIEX 6500 + Series with IonDrive Technology New Improved IonDrive detection system Detect analytes across a wide scope of chemistries, low mass or high mass, positive or negative polarity Quantify with lowest limits of quantitation and up to 6 orders of linear dynamic range Ultra fast polarity switching with Scheduled MRM Pro algorithm for multi-target quantitation Elevated SelexION technology Jet Injection technology with improved transmission and no effect on resolution Audible noise reduction New New Industry proven performance of IonDrive Turbo V ion source and QJet ion guide Results in less time fast, high-throughput, simplified data processing tools Service and support resources for success 2 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Hardware Overview RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Improved IonDrive Detection System New detector Larger detection area New power supply High energy dynode at 15 kv improves sensitivity Enables faster 5 msec polarity switching Floated design Ions in negative polarity directed straight into the detector This benefits low mass ions which are detected much more efficiently than in the 6500 system Contributes to significant signal gains in negative mode Q3 fragment ion <100 Da S/N (LOQ) improvements are compound, matrix and LC dependent Improved data quality in screening applications with ultra-fast 5 msec polarity switching 4 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Sensitivity of 6500 + System in Positive Polarity 0.1 pg/ml Testosterone (with SelexION + Technology, 50 µl Injection) 5 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Linearity of 6500 + System in Positive Polarity 0.1 to 100 pg/ml Testosterone (with SelexION + Technology) 0.1 to 5 pg/ml Accuracies: 92 to 109% %CV: 3.8% at 0.1 pg/ml 6 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Linearity of 6500 + System in Positive Polarity 1 to 100,000 pg/ml Flurazepam (with SelexION + Technology) 1 to 1000 pg/ml 5 orders r > 0.9999 7 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Sensitivity of 6500 + System in Negative Polarity 1 ng/l (1 part-per-trillion) PFOA and PFOS (Linearity 0.5 to 5000 ng/l) PFOA 413/369 413/169 413/219 Quantifier (blue) Qualifier 1 (purple) Qualifier 2 (orange) PFOS 499/80 499/99 Quantifier (blue) Qualifier 1 (purple) 8 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Sensitivity of 6500 + System in Negative Polarity 100 ppt PFBS QTRAP 5500 LC-MS/MS system QTRAP 6500 + LC-MS/MS system MRM 298.9 / 80.0 ~ 2x S/N improvement MRM 298.9 / 99.0 ~ 2.5x S/N improvement 9 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Sensitivity of 6500 + System in Negative Polarity 0.1 ng/ml (100 ppt) Monofluoroacetate (Linearity 0.05 1000 ng/ml) 77/57 (blue) 77/33 (purple) Internal standard 81/60 (blue) 81/35 (purple) Accuracies: 96.1 to 110.9% %CV: 4.99% at 0.1 pg/ml (n = 10) 10 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Ultra Fast Polarity Switching of 6500 + System Multi-Pesticide Screening for ~300 Analytes with 5 msec Switching 552 MRM transitions Positive ESI Flufenacet CV = 4.37% Methoxyfenozide CV = 1.52% 58 MRM transitions Negative ESI 11 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Multi-Pesticide Screening with 5 msec Polarity Switching Pesticide Standard and Sample Extracts (Positive Polarity) 1 ng/ml Tomato (10x) Cucumber (10x) Banana (10x) Strawberry (10x) Lemon (10x) Arugula (20x) 12 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Multi-Pesticide Screening with 5 msec Polarity Switching Pesticide Standard and Sample Extracts (Negative Polarity) 1 ng/ml Tomato (10x) Cucumber (10x) Banana (10x) Strawberry (10x) Lemon (10x) Arugula (10x) 13 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Software Overview RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Quantitation and Ion Ratio in MultiQuant Software QuEChERS Extract of Cucumber (dspe with PSA) and 10 x Dilution Propamocarb Std. 1 Lemon Tomato Cucumber Strawberry Arugula 15 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

QTRAP Library Searching in MasterView Software QuEChERS Extract of Cucumber (dspe with PSA) and 10 x Dilution Sample Standard MS/MS FIT = 100% 16 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Quantitation and Ion Ratio in MultiQuant Software QuEChERS Extract of Strawberry (dspe with PSA) and 10 x Dilution Dimethoate Std. 1 Lemon Tomato Cucumber Strawberry Arugula 17 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

QTRAP Library Searching in MasterView Software QuEChERS Extract of Strawberry (dspe with PSA) and 10 x Dilution Sample Standard MS/MS FIT = 100% 18 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Quantitation and Ion Ratio in MultiQuant Software QuEChERS Extract of Strawberry (dspe with PSA) and 10 x Dilution Fludioxonil (-) Std. 1 Lemon Tomato Cucumber Strawberry Arugula 19 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

SelexION + Technology Differential Mobility Spectrometry (DMS) RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Lens Lens SelexION + Ion Mobility Device with Jet Injector Technology New DMS cell designed to improve ion transmission by ~2x without loss in selectivity or resolution Addition of lens increases ion velocities into cell Reduces transit times through detrimental fringing fields SelexION cell Lens DMS Electrode 1 DMS Electrode 1 DMS Electrode 2 DMS Electrode 2 DMS Electrode 1 DMS Electrode 1 Only available on 6500 + platform SelexION + cell Lens DMS Electrode 2 DMS Electrode 2 Continually driving selectivity improvements 21 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Detection of Triazole with and without DMS 6500 + with DMS 6500 + DMS removed S/N ~ 60 Standard 0.5 ng/l N NH N Spiked and extracted fruit (10 µg/kg) S/N ~ 390 IS = 3000 V; TEM = 550ºC 22 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Linearity and Repeatability (0.01 mg/kg 50 mg/kg; n = 3) Accuracy 97-103% %CV < 2% 23 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Added Selectivity to Simplify Sample Extraction Example: 1 µg/kg Imidacloprid and Metabolites in Bee Pollen Analyzed using QTRAP 6500 + System with SelexION + Technology Imidacloprid Imidacloprid-IS 5-OH Olefin Pollen extract 4x dilution, average sensitivity gain over 6500 with DMS = 3x 24 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Detection of Somatostatin with and without SelexION + 6500 + with DMS 6500 + DMS removed 100 pg/ml Somatostatin, a cyclic peptide with poor MS/MS fragmentation is acquired using MIM (819.7/ 819.7) assay in rat plasma showing high background noise limiting the S/N ratio and LOQ Highly reduced background noise enabling desirable LOQ of 100 pg/ml using new SelexION + jet injector on 6500 + System (S/N ratio = 12, accuracy = 101% and %CV < 10% ) 25 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Industry Proven Robustness and Ruggedness SelexION +, IonDrive Turbo V Ion Source and QJet Ion Guide Alprazolam %CV = 3.5% Buprenorphine %CV = 7.9% Clenbuterol %CV = 2.9% Methamphetamine %CV = 2.8% Repeatability of 4000 injections (crashed human plasma (1:3) diluted 1:2) 26 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Industry Proven Robustness and Ruggedness 1. Injection 1000. Injection 2000. Injection 3000. Injection 4000. Injection Alprazolam Buprenorphine Clenbuterol Methamphetamine Repeatability of 4000 injections (crashed human plasma (1:3) diluted 1:2) 27 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Audible Noise Reduction Active (source exhaust modifications) Source exhaust flow minimized to match gas load Current shipping design assumes maximum incoming source gas load at all times Passive (quieter tubing) Eliminate whistling noise Quieter system operation than 6500 Noticeable under most source conditions No impact to sensitivity Decreased audible noise for a more comfortable work environment 28 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

The New SCIEX 6500 + Series and SelexION + technology Industry proven performance: IonDrive Turbo V ion source and QJet ion guide Significant sensitivity boost in low mass negative mode with new HED + detector technology Enhanced SelexION + performance with new jet injector DMS cell without compromising resolution Fast polarity switching speed (5 msec) Audible noise reduction 29 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures

Trademarks/Licensing For Research Use Only. Not for use in diagnostic procedures. 2015 AB Sciex. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. 30 2015 AB Sciex RUO-MKT-11-2491 For Research Use Only. Not for use in diagnostic procedures