Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied with the terminal blocks), - Compliant with IEC 6097-7-3 standard, - Quickly identify the defective circuit thanks to the blown fuse indicator (with leakage current < 0. ma). SNK6F00 SNK0007F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC006 F0000 Screw Clamp Terminal Blocks mm² AWG mm 0.3 in Spacing Ordering Details Color Grey, Dark Grey Grey, Dark Grey ey, Dark Grey ey, Dark Grey Type ZS-SF-R ZS-SF-R3 Order Code SNK0R0000 SNK0R0000 EAN Code 3790 37990977 Pack (ing) 0 0 Weight ( pce) g 3.30 3.30 Declarations and Certificates CE CB RoHS USR CNR CSA GOST R BV RINA DNV
Declarations and Certificates CE CE CB CB RoHS RoHS USR CNR USR CNR SND09C* SND630A0* SND309F0* SND60A0* CSA CSA SND670A0* GOST R GOST R SND60A* BV BV SND673A0* RINA RINA SND6A0* DNV DNV SND67A0* Explosive Atmosphere: ATEX Classification Group Category Protection Method In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information Wire stripping length 0.33 in Ex e: increased security The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail IEC 6097- TH3-7., TH3- Denudage IP0 TH3-7., TH3- mm NEMA Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 3. mm 0.3 in 0.6 N.m.3 lb.in ± 0. N.m ± 0. lb.in Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL9 V0 NF F 6 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter Needle flame testec 606-- Compliant Screw clamp IEC6097-7-3 UL9 0.... mm²... AWG IEC6097-7-3 0.... mm² 0.... mm²... AWG 0.... mm²... AWG A3-B3 3 mm IEC 6097-0. in Ferrule. mm 0.6 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²). Technical Datasheet SNK63D00 ABB
Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors Flexible conductors Flexible conductors with twin ferrule IEC6097-7-3 0..... mm² IEC6097-7-3 0..... mm² 0..... mm² Don't mix solid and flexible conductors in the same clamp UL9... 6 AWG... 6 AWG Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²) Cross section Rated cross section IEC6097-7-3 mm² UL9 AWG Maximum Cross section mm² AWG Electrical characteristics Current Rated current IEC6097-7-3 6.3 A Field and factory wiring Cat. UL 9 A Factory wiring Cat. UL 9 A CSA-C-. n 6.3 A Maximum Exe current IEC/EN 60079-7 Rated short-time withstand current s (Icw) Short-time withstand current 0. s s s 30 s min IEC6097-7-3 Rated short-circuit withstand current CSA-C-. n Max. current ( temperature increase) / Max. cross section (mm²) 6.3 A Maximum short circuit current (s) mm² Short Circuit Current Rating (SCCR) SA UL 9 supplement SCCR UL 9 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK G CC Voltage Rated voltage IEC 6097-630 V Rated voltage UL 9 300 V Use Group UL 9 B, C Rated voltage CSA-C-. n 300 V Rated voltage Ex e IEC/ EN 60079-7 Rated impulse withstand voltage IEC 6097-000 V Dielectric test voltage IEC 6097-00 V Pollution degree IEC 6097-3 Overvoltage category IEC 6097- III ABB Technical Datasheet SNK63D00 3
Temperature range Ambient temperature min/max Storage -... + C Installing -... +0 C Service -... + C -67... +30 F -3... + F -67... +30 F Current Derating curve for continuous service temperature SNK0009F0000 Dissipated power Maximum dissipated power at rated current IEC 6097- Maximum dissipated power at maximum Exe current IEC 60079-7 Rated power dissipation at an ambient temperature of 3 C - IEC 6097-7-3 Separate arrangement / Overload and short-circuit protection. Separate arrangement / Exclusive short-circuit protection fuse and feed-through blocks Compound arrangement / Overload and short-circuit protection.6 Compound arrangement / Exclusive short-circuit protection fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 6006- Compliant Temperature +0 C 96 h IEC 6006-30 Compliant Temperature + C Relative humidity Number of cycles ( cycle = h) IEC 6006- Compliant Temperature -0 C 96 h IEC 6006--7 Temperature Relative humidity Corrosion Salt mist IEC 6006- Compliant 96 h Concentration % SO ISO 69 Compliant h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 6006-60 Number of the test method Technical Datasheet SNK63D00 ABB
Vibrations and shocks Sinusoidal vibrations IEC 6006--6 Compliant Frequency range... Hz Number of cycles Acceleration m/s² Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Shock IEC 6373 Category Class B 3 axes Acceleration ZS-SF-R Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. Description Type Order Code Pack (ing) Weight pieces g ( pce) End Stops BAM3 SNK90000R0000 0 3.0 3 6 7 9 End Stops End Sections Lateral Jumper Bars Assembly Rods Assembly Rods Assembly Rods Protecting Cover Kits Protecting Covers Spring Retaining Rings Tools BAZ ES-SF PC- FU0 FU0 FU0 FU0 FU0 FU FU FU FU FU TGA TGA TGA KCO CO PR3.G PR PR PR30 PR3.Z ANT PS-3 MC MC-YL MCPA UMH PROCAP SAT SNK90000R0000 SNK0960R0000 SNA733R0 SNA00R00 SNA009R600 SNA0090R300 SNA009R0000 SNA009R00 SNA676R00 SNA677R300 SNA67R000 SNA679R000 SNA670R000 SNA667R0 SNA6673R00 SNA667R300 SNK9006R0000 SNK90060R0000 SNA600R0300 SNA600R00 SNA6700R00 SNA730R000 SNA7300R700 SNA667R00 SNK90060R0000 SNK60000R0000 SNK6000R0000 SNK69999R0000 SNK9006R0000 SNK90063R0000 SNK90066R0000 0 0 0 0.30..00.00 7.0 300.00 9.00 3.00 30.00.00.00.00 0.0.00 6.00 Screw Clamp Terminal Blocks ZS-SF-R Screw Clamp Terminal Blocks SNK0R0000 0 3.30 ABB Technical Datasheet SNK63D00
SNK63D00 - PDF Contact us ABB France Low Voltage Products Division Export Department, rue Ampère Z.I. - B.P. F-696 Chassieu cedex / France Tel. +33 (0) 7 7 Fax +33 (0) 7 93 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved