Max. Input Power (W) Inrush Current (A pk /µs)

Similar documents
Input Current at 240V (A) Max. Input Power (W) Enclosure

Input Current at 240V (A) Max. Input Power (W) Dimming Method 1-10V Isolated. Enclosure

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

Load Com/Diff(KV) (Kg) Rating * V 240V 277V V 240V 277V V 240V 277V > / 4 0.

Max. Input Power (W) Input Current. Inrush. 277 Vin 7.4 / 600. Dimming Method. 1-10V Isolated. Enclosure

Max. Input Power (W) Input Current V Isolated DALI

Max. Input Power (W) Input Current v 2 2 0v 2 40v. Enclosure

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO.

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Model Number AC-50CD1.4APNZ AC-50CD1.4APBNZ

Input Power (Watts) (min/max)

Input Current (Amps) Input Power (ANSI Watts)

LPF-25 series. 25W Constant Voltage + Constant Current LED Driver

Input Current (Amps) Input Power (ANSI Watts)

Input Power (Watts) (min/max)

ICN2S40N35I Ele Ballast (2) F40T V

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

JOB NAME MODEL NO. LAMP OUTPUT VOLTAGE

Input Current (Amps) Input Power (ANSI Watts)

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

IS 15885(Part 2/Sec13) R ( for 24V only)

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

LED Modules. Fortimo DLM ES 0-10V G1 NA 1100lm

RELB2S40N35I (2)F40T12 120V Ele BLST

SELV IP30 (CCC optional)

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

TrustSight LED Emergency Lighting

60W Constant Current Mode LED Driver. HBG-60 series. File Name:HBG-60-SPEC

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

UL TEST REPORT AND PROCEDURE

LED Driver Linear / area dimming

Dry Type Distribution Transformers

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PD-Series Ground Fault Circuit Protection

Generator Fire Safety: Generator assemblies should be located outside the building.

TrustSight LED Emergency Lighting

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

EcoSystem Multiple Control Input Ballasts

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

Reduce Maintenance Costs *

HPS Fusion General Purpose Enclosed Transformer

60W Single Output LED Power Supply. HBG-60 series. File Name:HBG-60-SPEC

High Bay Luminaire Series

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

High performance for high ceilings

Versatile Power Entry Module with Small Footprint. PS non-filtered

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Industrial Control Transformers

Dry Type Distribution Transformers

LV Capacitor CLMD03 Power Module Instruction manual

High Frequency SineWave Guardian TM

LED Driver Linear / area fixed output

Model Number Structure

Industrial Control Power Transformers Class MT

Medium Voltage Metal-Enclosed Switches

Power Supplies PSS Series

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

UL TEST REPORT AND PROCEDURE

Industrial Control Power Transformers

OUTDOOR TRACK. LABELS Assembled in America

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings

Indoor Linear 50W Driver SI-CU WW

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings

G-Series. Circuit Breaker.

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

MnDOT Specification Light Emitting Diode (LED) Luminaire For Roadway Lighting Asymmetrical High Mast 04/19/18

UL TEST REPORT AND PROCEDURE

HBDBM High Bay Series

Uninterruptible Power Supplies

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Selection Guide. Control Circuit and Load Protection

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine

Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer

Outdoor 200 W 2 Channel SL-L2701B0N1KR

GB60S 60W Single Output General Purpose Series

LED control gear Compact fixed output

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

WEM-MX-333mV. Integrated Meter Installation Guidelines

Installation Instructions: Read these instructions in its entirety before performing any installation work.

PDMHB Watt LED I-Beam High Bay

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Transcription:

Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max. THD (%) Min. Power Factor Surge Protection (KV) Weight (Lbs) IP Rating 165 278/400 20 0.90 2.5 2.8/1270 IP66 Enclosure INPUT BLACK (LINE) WHITE (NEUTRAL) LED DRIVER OUTPUT RED (POSITIVE) LED ARRAY BLUE (NEGATIVE) Input & Output use18awg 105C/600V solid copper lead wires Standard Lead Length in. cm. Black 8 20 White 8 20 Blue 8 20 Red 8 20 Gray Violet Maximum Wiring Distance (at full load) Wire Size (AWG) Distance (feet) 26 8 24 13 22 21 20 34 18 54 16 85 14 137 12 210 10 357 E321253 in. (mm) Case Length 8.38 (211.1) Case Width 2.35 (59.1) Case Height 1.47 (37.1) Mounting Length 9.0 (226.2) Mounting Width 1.7 (42.9) Overall Length 9.54 (240.5) 7310_S-000 3426-32

Installation & Application Notes: Section I Physical Characteristics 1.1 LED Driver shall be installed inside an electrical enclosure 1.2 Wiring inside electrical enclosure shall comply with 600V/105 C rating or higher. Section II Performance 2.1 LED Driver complies with UL standard UL1012. 2.2 LED Driver has Class A sound rating. 2.3 LED Driver has a minimum operating ambient temperature of -40 C. 2.4 LED Driver has a life expectancy of 50,000 hours at Tcase of 75 C. 2.5 LED Driver has a life expectancy of 100,000 hours at Tcase of 65 C. 2.6 LED Driver has a typical self rise of 25 C at maximum load in open air without heat sink. 2.7 LED Driver is certified by UL for use in a dry or damp location (Outdoor Type I). 2.8 LED Driver tolerates sustained open circuit and short circuit output conditions without damage. 2.9 LED Driver maximum allowable case temperature is 80 C see product label for measurement location. 2.10 LED Driver reduces output power to LEDs if maximum allowable case temperature is exceeded. 2.11 LED Driver has a failure rate of 0.01% per 1,000 hours at Tcase 70 C. 2.12 LED Driver complies with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR Part 15 Non-Consumer (Class A). Section III UL Conditions of Acceptability (File E321253) When installed in the end-use equipment, the following are among the considerations to be made: 3.1 The equipment shall be installed in compliance with the enclosure, mounting, spacing, casualty and segregation requirements of the ultimate application. 3.2 Consideration should be given to measuring the temperatures on electronic components of power circuits and transformer windings when the unit is installed in the end-use equipment based upon mounting orientation, operating ambient and ventilation. Magnetic components L2, T3, L5 and T2 employ Class 130(B) insulation. 3.3 These drivers should be used within the recognized ratings. 3.4 The driver is suitable for use in DAMP and DRY locations. 3.5 When the drivers are installed in the end-use application, the case temperature should not exceed the temperature limits specified in the following table: Model No. Input Voltage, Hz Tc, C 120-277, 60 Horizontal 80 250VDC Horizontal 3.6 The maximum measured leakage current was 0.210 MIU while connected to a 120V branch source and 0.56 MIU while connected to a 277V source of supply. 3.7 For 250 Vdc application, driver must be additionally provided with an external DC fuse in the end-use application. Fuse must be Listed, CSA certified, manufactured LittelFuse, designated CCMR, rated 250 Vdc, 10A maximum. Fuse

to be wired into the Hot leads of the driver. The method of adding the external fuse and fuse holder to be evaluated in the end-use application.

110 Lifetime vs Tcase 100 90 80 Life (khours) 70 60 50 40 30 25 30 35 40 45 50 55 60 65 70 75 80 85 Tcase (deg. C) Failure Rate per 1kHr 0.021 0.02 0.019 0.018 0.017 0.016 0.015 0.014 0.013 0.012 0.011 0.01 0.009 Failure Rate VS Tcase 25 30 35 40 45 50 55 60 65 70 75 80 85 Tcase in C