LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Similar documents
PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

TIME-10 Process Control Stopwatch

TMA5 Mini Vane Anemometer

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PY-11 Voltage & Continuity Tester

TACH-10 Contact / Non-Contact Tachometer

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

THWD-3 and TH-3 Relative Humidity and Temperature Meters

KMP Insulation-Continuity Tester. Users Manual

INSP-3 Wiring Inspection Tester

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

KMP7010. Ground Resistance Tester. Users Manual

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Operator s Manual TC-253A. Temperature Converter

TMD90A Dual Input Digital Thermometer

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Visit us at

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

323/324/325 Clamp Meter

362 Clamp Meter. Users Manual

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

302+/303 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

373 Clamp Meter. Users Manual

233 True-rms Remote Display Digital Multimeter Safety Information

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

i3000s/i2000 Flex AC Current Probe

Users Manual. Phase Rotation Indicator

362 Clamp Meter. Users Manual

716 Pressure Calibrator

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Visit us at SOLAR-500. Solar Analyzer. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Instruction Manual. IM-191 Magnetic Field Meter

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:


Users Manual. Airflow Meter

1000FLT. Users Manual. Fluorescent Light Tester

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

712 RTD Calibrator. Instruction Sheet. Introduction

i400s Calibration Information Introduction

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Go to to register your product and find more information.

Infrared Thermocouple Probe

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Model 1693, 1694 Switching DC Power Supply

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Tachometer. English. Users Manual

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

SOIL RESISTIVITY TESTER

Cable Length Meter INSTRUCTION MANUAL

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

PolyStat Immersion Circulators


Lab Rotators and Low Cost Orbital Shakers

Defender 3000 Series Base Instruction Manual

Megohmmeter Test Probe

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

BARNSTEAD THERMOLYNE ROTO MIX TYPE

SLA Battery Capacity Analyzer

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

700G Series. Users Manual. Pressure Gauge

Users Manual. MegOhmMeter

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Switching DC Power Supply

KSZ 10B Current Probe Calibrator. Instruction Manual

P5510. Users Manual. Pneumatic Comparison Test Pump

Temperature Calibrator

Model P772 Conductivity Meter. User Manual

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

182-LED Solar-Powered Motion Security Light. Owner s Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

4-20mA DC PROCESS CLAMP METER

SECULIFE PS100 PATIENT SIMULATOR

HIGH VOLTAGE PROVING UNIT

Transcription:

LM-100 LM-120 Light Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com

LM-100 / LM-120 Light Meters English Users Manual LM100_Rev002 2008 Amprobe Test Tools. All rights reserved. 1

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. This warranty is your only remedy. All other warranties - whether express, implied or stautory - including implied warranties of fitness for a particular purpose or merchantability, are hereby disclaimed. Manufacturer shall not be liable for any special, indirect, incidental or consequential damages or losses, arising from any cause or theory. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries please read the warranty statement and check your battery before requesting repair. during the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates. 2

1 2 MAX MIN HOLD FC LUX 3 4 5 Lx / Fc MAX AUTO ZERO HOLD MAN 7 8 6 9 LM-100 LM-120 ➊ Light sensor ➋ Display(LCD) ➌ Lux / foot candles ➍ MAX HOLD (LM-100) / MIN and MAX value (LM-120) ➎ Power Button: ON/OFF ➏ Manual range selection ➐ DATA HOLD button ➑ AUTO ranging ➒ Light sensor Zero Adjustment 3

LM-100 / LM-120 Light Meters Contents Symbols... 5 Unpacking and Inspection... 5 Introduction... 5 Operation... 5 Lx / fc... 6 Data Hold... 6 MAN Ranging (LM-100)... 6 AUTO / MAN Ranging (LM-120)... 6 MAX... 6 Auto-Power Off... 6 Zero (LM-120)... 6 Specifications... 6 Maintenance and Repair... 7 Battery Replacement... 8 4

Symbols W ; Caution! Refer to the explanation in this Manual P Conforms to relevant Australian standards. = Complies with EU directives Do not dispose of this product as unsorted municipal waste. W Warning and Precautions Do not operate the meter in explosive gas (material), combustible gas (material) steam or filled with dust. The light sensor is calibrated to CIE standard incandescent lamp at 2854 K and may give different readings for spectrums from other lamp types. Unpacking and Inspection Your shipping carton should include: 1 LM-100 or LM-120 light meter 1 9 volt battery 1 Users Manual If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange. Introduction The LM-100 and LM-120 measure the visible light from fluorescent, metal halide, high-pressure sodium or incandescent sources. One LUX (Lumen) is the illumination from a one candela lamp perpendicular to a surface one meter squared at a distance of one meter. One foot-candle (Fc) is the illumination from a one candela lamp perpendicular to a surface one foot squared at a distance of one foot. Operation 1. Press the + button to turn power on or off 2. Remove sensor cap and place the sensor perpendicular to the light. 3. Select Illuminance scale and range for reading. 4. When done testing, replace the sensor cover to protect the filter and sensor. 5

Lx / fc Illuminance scales. 1 foot-candle = 10.764 Lux and 1 lux = 0.09290 footcandles. Data Hold Freezes the reading present on the LCD at the moment the button is pressed. Press HOLD again to disable Data Hold. MAN Ranging (LM-100) Press the MANual ranging button for useable reading. AUTO / MAN Ranging (LM-120) Press the AUTO or MANual ranging button for useable reading. AUTO ranging is the default operation. MAX (LM-120) The MAX MIN feature reads and updates the display to show the maximum or minimum value measured after you press the MAX MIN button. Pressing the MAX MIN button for less than 1 second will put the meter into a mode of displaying the maximum, minimum, or actual readings. Each time the MAX button is pressed, the meter will cycle from MAX MIN off. Press the MAX MIN button for more than 1 seconds to disable this feature. Select the proper measurement range before enabling the MAX MIN feature. Auto-Power Off (LM-120) In order to save battery life, your light meter powers down automatically after approximately 6 minutes of inactivity. You can turn it back on by pressing the + button. You can disable Auto Power Off by pressing and holding the HOLD button while turning the meter ON. Zero (LM-120) The light sensor will change the null point over time. To reset the null point, cover the sensor, press the ZERO button. The display will show ADJ. When the null reset is done, the display will read 00.0. Specifications General: Sampling Rate: 2.5 times per second for digital display. Display: 3 ½ digit, 1999 count LCD Sensor: Silicon photodiode and filter. Environment: indoor operation Altitude: Up to 2000m. Temperature / Humidity: Operating: -10 C to 50 C, 0 to 80 %RH. 6

Storage: -10 C to 50 C, 0 to 70 %RH. Power Supply: 9V NEDA 1604, IEC 6F22, JIS 006P battery Battery life: 200 hours Auto Power Off: approx 6 min Dimension (Base): 130 x 63 x 38 mm (5.1 x 2.5 x 1.5 ) Dimension (Sensor): 80 x 55 x 29 mm (3.2 x 2.2 x 1.1 ) Weight: 220 g (.48 lb.) include battery P-EMC: EN61326-1 This product complies with requirements of the following European Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. Illumination: Measuring Range: 20, 200, 2000, 20000, 200000 Lux 20, 200, 2000, 20000 Foot candles Accuracy: ± 3 % (Calibrated to standard incandescent lamp at 2854 K) 6% other visible light sources Angle deviation from cosine Characteristics 30 ± 2 % 60 ± 6 % 80 ± 25 % Cosine Angular corrected per JIS C 1609:1993 and CNS 5119 general A class specifications. Maintenance and Repair If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem. 1. Check the battery. Replace the battery immediately when the symbol N appears on the LCD. 2. Review the operating instructions for possible mistakes in operating procedure. Except for the replacement of the battery, repair of the meter should be performed only by a Factory Authorized Service Center or by other qualified 7

instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. Battery Replacement 1. Turn off the meter and slide out the battery cover. Replace the battery with a NEDA type 1604 or equivalent 9V alkaline battery. Replace the cover. 2. Remove battery when the LM-100 / LM-120 is not used for extended period. OPEN Battery Replacement 8