Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Similar documents
Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

New! Fluke 922 Airflow Meter. Fluke HVAC/IAQ Tools. Get more done.

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

362 Clamp Meter. Users Manual

T2 Tester. Calibration Information. Introduction. Safety Information

2271A Industrial Pressure Calibrator Extended specifications

Users Manual. Airflow Meter

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.


FEATURES AND BENEFITS

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

323/324/325 Clamp Meter

365 Detachable Jaw True-rms Clamp Meter

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

PRODUCT ANNOUNCEMENT. There is a better way to measure air flow. The New Fluke 922 Airflow Meter

Fluke 500 Series Battery Analyzers

YCCS Zone/Bypass Damper Assembly

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

THWD-3 and TH-3 Relative Humidity and Temperature Meters

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Laboratory Room Controller

362 Clamp Meter. Users Manual

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

European Technical Standard Order (ETSO)

Dry Block and Liquid Bath Temperature Calibrator Series

HM1520LF Relative Humidity Module

HUMIDITY / TEMPERATURE TRANSMITTER

PROHOOD AIR CAPTURE HOOD MODEL PH731

Digital Insulation Resistance Testers. you can depend on

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

373 Clamp Meter. Users Manual

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe

YCCS Zone/Bypass Damper Assembly

Thermo-hygrometer-anemometer VT 210

EATON 9315 UPS 200 TO 300 KVA Specifications

302+/303 Clamp Meter. Users Manual

Thermo-hygrometer-anemometer VT 210

RULES PUBLICATION NO. 98/P

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

Low Profile DC Power Supply with Zero Voltage Soft Switching

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Short manual testo 410-2

707Ex. Users Manual. ma Calibrator

2-Year Limited Warranty. See the Users Manual for the full warranty.

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

i400s Calibration Information Introduction

DSPS DSPS. Wide DC input. Switching Power Supply. Models: ESA-DS160 ESA-DS200. ESA-DS Ver.1.01 PAGE: 1 OF 7

Powerware Vdc Extended Battery Cabinet User s Guide.

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Model 8345/8346/8347/8347A VELOCICALC Air Velocity Meters

Go to to register your product and find more information.

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features. Display

Video & Power Over Coax Kit

IAQ-CALC TM Indoor Air Quality Meter

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

Infrared Thermocouple Probe

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

80 Series V Digital Multimeter Safety Information

User's Guide. CO 2 Meter. Model CO250

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

RESOLUTION MEPC.198(62) Adopted on 15 July GUIDELINES ADDRESSING ADDITIONAL ASPECTS TO THE NOx TECHNICAL CODE 2008 WITH REGARD TO

DF5NX P/N _J NSF. Certified. Technical Data Sheet. January Scan QR code to access product information on your mobile device.

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

ADN-W L 10. Battery Charger. Instruction manual

Express 100 DC Commercial Charging Stations

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

The Alnor Product Catalog

INTERNATIONAL MARITIME ORGANIZATION (IMO) Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

EE75. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

SMGV Technical Data Sheet

PERFORMANCE SPECIFICATION SHEET BATTERY, RECHARGEABLE, NICKEL CADMIUM, VENTED, 1.2-VOLT, 13 AMPERE- HOUR, BB-475/A CELL

Totally Sealed Hour Meter

Hot Wire CFM/CMM Thermo-Anemometer

CW2EGE C E. Technical Data Sheet P/N _B NSF. Certified. November Item Part # Description Wiring Item #

Ventilation Control. Ventilation Control 12

3M Test Kit for Static Control Surfaces 701. User s Guide

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

Portable TOC Analyser for Stack Emissions

STRIDER ESSENTIAL SERIES ST50F-ESB ST40F-ESB Power for everything you need

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ME5X-GP P/N _G NSF. Certified. Technical Data Sheet. April Spanish P/N

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Wireless Accelerometer - Vibration Meter

Digital Formaldehyde Meter

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Short manual testo 610

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Dry Block and Liquid Bath Temperature Calibrator Series

EGQ 212: Duct transducer, CO 2 and temperature

MS4525 SPECIFICATIONS

A2 Humidity Temperature Indicator SUPPLEMENTAL INSTRUCTIONS

Transcription:

Manual Supplement Manual Title: 975 Users Supplement Issue: 7 Part Number: 2507213 Issue Date: 10/11 Print Date: August 2006 Page Count: 7 Revision/Date: This supplement contains information necessary to ensure the accuracy of the above manual. 2008-2011 Fluke Corporation. All rights reserved. Printed in the U.S.A. x

Change #1, 46008 On pages 27 through 30, replace all the Specifications with the followinggeneral Specifications Measured Parameters Range Display Resolution Accuracy % of Reading Temperature -5 to 122 F -20 to 50 C 0.1 F 0.1 C ±0.9 C /±1.62 F from 40 C to 50 C ±0.5 C /±1.00 F from 5 C to 40 C ±1.1 C /±1.98 F from -20 C to 5 C Relative Humidity Air Velocity 10 to 90 % R.H. non-condensing 50 to 3000 fpm 0.25 to 15 m/sec 0.1 % 1 fpm 0.001 m/sec CO 2 0 to 5000 ppm 1 ppm CO 0 500 ppm 1 ppm ±3 % RH from 10 % RH to 90 % RH Includes 1 % hysteresis ±4 % or 4 fpm* ±4 % or.02 m/sec* whichever is greater * Accuracy specification only valid for velocity readings above 50 fpm or 0.25 m/sec. Warm up time 1 min (5 minutes for full specification) 2.75 % + 75 ppm ±5 % or ±3 ppm, whichever is greater, @ 20 C and 50 % RH Additional de-rating over Temperature: ±0.6 %/ C from calibration temperature ±0.6 %/ C < 20 C Long term drift < 2 % per month. Maximum shift in arid or humid storage conditions*: ±0.6 % per day (Reference storage test conditions: 50 C, 15 % RH and 30 C, 95 % RH) *After the CO calibration seal is removed and the Meter is stored for an extended period in arid or humid conditions, verify that the sensor is within specification by applying a known concentration of gas using the calibration gas kit. 3/08 1

Calculated Parameters Calculated Parameters Dew Point Temperature Wet Bulb Temperature Volume Flow Rate (in a duct) % outside air (Based on Temperature) % Outside Air (Based on CO 2 ) Minimum, Maximum and Average on all measured parameters -44 to 50 C Range -47 to 122 F -16 to 50 C 3 to 122 F 0.1 C 0.1 F 0.1 C 0.1 F 1 cfm 0.01 M 3 /hr Display Resolution Accuracy ±1 C When Temp: -20 C to 50 C RH: 40 % to 90 % ± 2 C When Temp: -20 C to 50 C RH: 20 % to 40 % ± 4 C When RH: 10 % to 20 % ±1.2 C when : RH: 20 % to 90 % Temp: -20 C to 50 C ± 2.1 C when : RH: 10 % to 20 % N/A The volume flow calculation will be a simple average of the data points times the duct area 0 to 100 % 0.1 % N/A 0 to 100 % 0.1 % N/A Per measured parameter spec Per measured parameter spec Per measured parameter spec 3/08 2

Environmental Specifications Operating and Storage Temperature: -20 to 50 C (-4 to 122 F) Humidity: 10 to 90 % non-condensing Altitude: Up to 2000 m (6562 ft) Shock and Vibration: Per MIL-PRF-28800F: Class 2 Physical Specifications Meter size: Meter weight: Hard-shell case size: Velocity probe size: Velocity probe weight: 198 g (7 oz ) Impact resistance: Power supply: Backup power supply: Battery life: 28.70 cm x 11.43 cm x 5.08 cm (11.3 in x 4.5 in x 2 in) 0.544 kg (1.2 lb) 11.93 cm x 35.65 cm x 43.18 cm (4.7 in x 14 in x 17 in) 28.70 cm, 99.06 cm extended x 2.54 cm (11.3 in, 39 in extended x 1 in) 1 m drop test (3.28 ft drop test) Rechargeable Lithium battery or Universal AC power adapter with plug adapters for USA, Great Britain, Europe, and Australia 3 AA batteries used as backup power Rechargeable Lithium battery - 11 hours (at room temperature)* Backup AA batteries - 7 hours *Note Lithium batteries can greatly extend the operating life of the meter if cared for properly. To ensure optimum capacity do not store for extended periods of time above 35 C (95 F). 3/08 3

Agency Approvals, Certifications and Standards Compliance The Meter complies with the following standards and meets requirements for the following certifications: EMC: EN61326-1. Class B FCC Part 15 Class B Industry Canada: ICES-003 Class B UL 1642 AS/NSZ CISPR 11 Class B Safety: EN61010:2001 P N10140 Change #2 On page 20, under Calibration, following the Note, add: Gas used for calibration is as follows: Nominal ppm Min ppm Max ppm CO 200 150 250 CO2 5000 4500 5000 3/08 4

Change #3 On page 20, replace the third paragraph with: Gas Canister and Regulator can be purchased from any Calibration Gas Supplier allowing the users to calibrate the CO and CO2 sensors. Add the following after the Note: Regulator requirement: 0.5 liters/minute flow rate On page 32, replace item 8 and add item 16 in Table 5. 2770767 Calibration-flow regulator value 2694684 Calibration Cap 10/11 5

On page 23, replace Figure 4 with: F1 F1 F1 VELOCITY PROBE Figure 4. Calibration Set up eba09f.eps 10/11 6

On page 31, replace Figure 6 with: 1 2 3 4 5 6 8 7 10 11 12 9 13 14 15 16 Figure 6. Replaceable Part and Accessories eba10.eps 10/11 7