797V Piezoelectric Velocity Sensor

Similar documents
Product Manual MNX10003 / REV C MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

Product Manual MNX10003 / REV B MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

DCS-400 Measuring Chains with LIN-340 Signal Conditioner and 10m Triaxial Cable Front End Installation Manual

DM-100 Creep Detection System Installation Manual

Sensor Mounting MACHINERY MONITORING. Mounting Configurations. Temporary Mounting

Caution. Description. Specifications and Ordering Information and Accelerometers

RANGER 900 POWER STEERING KIT

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

and Accelerometers

Transformer bushings, type GOH. Technical guide

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

LOAD CELL TROUBLESHOOTING

Mounting hardware and accessories

and Accelerometers Bently Nevada* Asset Condition Monitoring

Seismic Sensor Accessories SA, SV & ST 6000 Series

The information contained in this document is the property of Meggitt Sensing Systems and is proprietary and/or copyright material.

TMS Series MP46x Flex Probes* Installation Instructions

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

Acceleration Sensor AS - 030

VS / 069 / 077 / 079

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

ThermoLite 110W-330W Solar Panel Installation Instructions

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Copyright Birkin Cars (Pty) Ltd

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

MODEL ELC-12/60-D BATTERY CHARGER

BMK-12. Dual-Gard By-Pass Filter Mounting Kit Installation and Servicing Instructions

PPT 802, Proximity Probe Transducer System

UNIT 8 OTHER SENSORS

User Manual for the RAMK Rotational Absolute Magnetic Kit Encoder

It is strongly recommended that this kit be installed by an authorized Polaris dealer.

YAK-55M 1.8. Forget the rest - a YAK ist the best! Assembly instructions. Gernot

REF QTY PART DESCRIPTION PART NUMBER 1 1 Side Mirror, Driver (Not Shown) 1 Loctite - 263, 0.5 ml, Red Instructions

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

VIBRATION CONTROL VIBRATION CONTROL

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Proximity Transducers, Seismic Sensors and Accessories

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

Manual UB20 / UB40 / UB50 / 2 EL WiMo Antennen und Elektronik GmbH

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Track Light with Monitor Installation Guide

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

F111.X Flow Sensor for Hot Tap Installation INSTRUCTION MANUAL. 1. Introduction Safety Instructions Unpacking Description.

VIBRATING WIRE SURFACE STRAIN GAUGE. Model SM-5B. Roctest Limited, All rights reserved.

Installation Notes. PlayPorTT Kiosk Anti-Tip Safety Cable. (p/n )

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Signet 2517 Brass Paddlewheel Flow Sensor * *

I. Introduction - basic information 3 II. Installation into a vehicle 3. III. Attachments 9

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

POWER INVERTER 700 WATT / 1800 WATT PEAK

Service Bulletin No.: DAC Rev. 0 Date Issued: 25 August 2014 Title: Installation of a Heated Pitot Static Probe Page: 1 of 34 PRINT IN COLOUR

Open Center Compact Valve Custom Installation Guide Rev A

TECHNICAL INSTRUCTIONS

Vibration instrumentation in paper machines a unique environment

BMK-18 U.S. Patent #5,298,158

LTX RF LEVEL SENSOR. Instruction Manual

DMV-100 Rotor Creep and Speed Detector. Installation Manual

CVR-625. Compact Vibrating Rod Instruction Manual

Optimax Pro Retrofit Instructions

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

INSTALLATION INSTRUCTION MANUAL

Model 550 Series Vibration Switches

Fundamental Training. Flow Con t

Operation Manual Bently Nevada Asset Condition Monitoring

VIM20 Vortex Insertion Flowmeter

LINEAR ACTUATOR MODULE Page 5-1. Table Of Contents

Please read the operating instructions carefully before use and keep for future reference.

Selection and Installation of Vibration Sensors

LinkPro High Voltage Adapter Installation and Wiring Guide. Initial Release 01/14/10 Rev 1.0

MAR031615A 1. PABD Installation & Maintenance. Guide *Parts will differ for high pressure valves.

S-SERIES DISPLACEMENT TRANSDUCERS

INSTALLATION INSTRUCTIONS

Sensors for Industry Series Sensor Guide

Caution Improper installation could result in tape failure, mounting hardware, and reader. Please read instructions before installing!

1291BL Series Technical Specification Single Axis Position and Rate Table System

M670/M680BD MAGNALOCK SERIES Installation Instructions

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Solid-State Compass with GPS Receiver

HF Series Incremental Magnetic Encoder Decade Count High Resolution Kit

VW Surface-Mount Strain Gauge

RST INSTRUMENTS LTD.

958A Compact. Series 958 Compact Housing LDT. Housing ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

INSTALLATION MANUAL. Melink Corporation (513) Revision

Tiller Drive Installation Guide. Document number: Date: Oct 2006

Mallet Nut driver Pop rivet gun Protractor level

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

USB Charge Port Installation Instructions

Installation or Inspection Checklist

PONTIAC FIREBIRD

SEN and SEN Outdoor Air Temperature Sensors

FEATURES AND BENEFITS

RIM20 Rotor Insertion Flowmeter

CHAPTER 1C PREPARING FOR INSTALLATION

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

Annubar Flowmeter Series

Dual Remote Filtration System Installation and Servicing Instructions

Railway vibration measurement. Enhance safety and cut maintenance costs

Transcription:

797V Piezoelectric Velocity Sensor Installation Manual (Product # : 9400-09M2A-103) This manual divides into the following sections: Section 1: Section 2: Installation of the 797V Piezoelectric Velocity Sensor and Cable Datasheet: Model 797V PiezoVelocity Transducer Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor_Installation Manual_Table of Contents - Rev. 3 1

1. INSTALLATION OF THE 797V PIEZOELECTRIC VELOCITY SENSOR 1.1 Preliminary considerations The 797V piezoelectric velocity sensor is a solid-state device with an isolated piezoceramic sensing element capable of detecting high-level displacements in the same axis as the mounting hole on medium speed machines. It contains no moving parts and can be oriented in any direction. Operates under most harsh environmental conditions. Unaffected by dirt, oil, and most chemical atmospheres. The piezoelectric membrane minimizes the effects of transverse motion, base strain, and thermal transients. The flat frequency response is from 4 Hz to 1 khz. The mounting location must be chosen according to application. Absolute shaft vibration measurement applications requires that the velocity sensor be mounted on the same support structure and in the same axis as the proximity probe. The 797V piezoelectric velocity sensor is shipped with a captive screw for stud mounting. In selecting mounting location, pay attention to accessibility. The velocity sensor must in most cases directly contact the machine surface. If the velocity sensor is installed on an insulated bearing, a nonconductive mounting support must be used to preserve the integrity of insulation. The closer the contact is between the velocity sensor and the machine, the better the ability to couple and measure high frequency signals. Best efforts must be made to provide a flat, smooth, and even mounting surface by spot facing the location. The tapped hole must be perpendicular within 1 to the mounting surface. Avoid mounting the sensor on thin sections or vibration-free areas. Excessive mechanical shock from hard impacts can destroy the internal electronic components or fracture the piezoelectric crystal. Avoid dropping the velocity sensor. Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor and Cable_Installation - Rev. 3 2

1.2 SENSOR INSTALLATION 1.2.1 Supplies needed: Mounting screw 1/4-28 UNF or M6x1 Loctite 222 thread adhesive 1.2.2 Tools needed Drill bits 7/32 or 5mm Tap drills 1/4-28 UNF or M6x1 Torque screwdriver Caution: Use great care in handling the Model 797V velocity sensor. NEVER DROP it or hit it against a solid object. Keep it stored in its box until you have surveyed and prepared the location suitable for installation. 1.2.3 Step 1) Preparation of the mounting area 1. Select the best mounting location according to your application (refer to preliminary considerations). Prepare the surface and mounting hole according to Figure 1a) if the screw has UNF thread or Figure 1b) if the screw has a metric thread. a) b) Figure 1 : Preparation of mounting area Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor and Cable_Installation - Rev. 3 3

1.2.4 Step 2) Installation of the velocity sensor 1. Mount the velocity sensor using a torque screwdriver for tightening. The supplied captive screw should be torqued to a nominal value of 3,3895 Nm (30 lb-in). Under-torquing the velocity sensor reduces the stiffness of the coupling, while over-torquing can cause permanent thread damage. Note: Use loctite 222 thread adhesive for better results. Installation on an insulated bearing If the sensor is installed on an insulated bearing, special care must be taken to preserve the insulation of the bearing. The most widely recommended mounting method consists in placing a 0.063 in. thick mica sheet between mounting bracket and bearing, and using non-metallic screws. 1. Shown here is an alternate mounting method. The sensor is installed on an insulating block. 2. Glue is applied on the block and insulated surface. Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor and Cable_Installation - Rev. 3 4

3. The sensor is held in place until the glue has set. The sensor can be mounted vertically or horizontally. 1.3 CABLE INSTALLATION 1.3.1 Preliminary considerations This twisted pair, shielded, yellow teflon cable is 5 m (16 ft.) long and will run between the piezoelectric velocity sensor and the acquisition/monitoring unit. In applications of 1 khz maximum frequency such as the ones this sensor is designed for, the cable capacitance of 30 pf per foot allows the cable to run over a total length of 100 m (330 ft.). For applications involving cable longer than 5 m (16 ft.), a tapping box is needed. The cable should be enclosed in a protective conduit. 1.3.2 Step 1) Installation of the cable 1. Determine the run of the cable, keeping in mind that its maximum length is 100 m (330 ft.). 2. Unroll the protective conduit following the planned course of the cable. Cut the conduit to desired length. 3. With a fish tape, carefully pull the cable into the conduit. The socket connector must be placed on the velocity sensor side. 4. Connect the cable to the sensor. Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor and Cable_Installation - Rev. 3 5

5. Anchor the cable to reduce stress at the cable terminations. When securing the cable, leave enough slack to allow free movement of the velocity sensor as shown in Figure 2. Figure 2 : Securing the cable 1.3.3 Step 2) Connection of the power and output cable 1. Connect the wires according to the following designation: PIN # WIRE COLOR DESIGNATION A White Power/signal Shell Shield Ground B Black Common a) Uninsulated bearing The housing of the velocity sensor is connected to ground: do not connect the cable shield-toground at the monitored end. Figure 3 : Uninsulated bearing b) Insulated bearing The housing of the velocity sensor is isolated from ground: connect the cable shield-to-ground at the monitored end. Figure 4 : Insulated bearing Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor and Cable_Installation - Rev. 3 6

1.3.4 Step 3) Verification 1. Verify that the 797V piezoelectric velocity sensor is functioning well: measure the voltage at the output of the velocity sensor (e.g. between black and white wires, at input of the acquisition/monitoring unit). Note that the warm-up time is about two minutes. The bias voltage (or voltage at rest) should be about 10 V DC (+/- 1v). 2. Much lower or higher DC bias voltages indicate internal problems and the velocity sensor should be carefully packed and returned to the factory for repair. Vibrations Bias Voltage = 10V DC t Figure 5 : Vibrations to bias voltage Copyright VibroSystM Inc., 2008 797V Piezoelectric Velocity Sensor and Cable_Installation - Rev. 3 7