ATR35 Wafer Specification

Similar documents
Contact cleaning opportunities on single wafer tool

Contacting various metal compositions using ViProbe Vertical Technology

300mm Wafer Electroless Bumping

Probing Process Analysis and Continuous Improvement. John Strom Applied Precision Inc. (425)

Eutectic Sn/Pb Fine-Pitch Solder Bumping and Assembly for Rad-Hard Pixel Detectors

Interface-Unit (SIU) Design Methods for Reducing Burn Rates on Tight-Pitch C4 Logic Arrays

Advances in MEMS Spring Probe Technology for Wafer Test Applications

Designing for Cost Effective Flip Chip Technology

Keeping Your CMP Slurry From Being A Pain in the As-Probed Die Yield. Robert L. Rhoades (Entrepix) Brian Orzechowski and Jeff Wilmer (DivInd, LLC)

"Fusion Cuisine" Hybrid Technologies to address MEMS sensors, Magnetics and High Voltage Probing

Arcing prevention by dry clean optimization at Shallow Trench Isolation (STI) Etch in AMAT MxP by use of plasma parameters

Surface MEMS Design Examples Dr. Lynn Fuller Webpage:

Platinum-chip Temperature Sensors in SMD Design Type According to DIN EN 60751

A Trace-Embedded Coreless Substrate Technique

yard each of the following prints:

Frank Pietzschmann (IFX) James Andersen (APLLC)

Jet Dispensing Underfills for Stacked Die Applications

COSASCO Corrosion under Insulation (CUI) Corrosion Sensors

Kelvin Testing Using a GHz socket for MLF/QFN packages

0.3 mm Pitch, 1.0 mm Height FPC Connector

Benefits of Flip Chip Wafer Sort using MEMs Multi Site Capability

Creative Links to World Electronics

MPC8271/MPC8272/ MPC8247/MPC8248 Product Information:

Advanced Technique for Si 1-x Ge x Characterization: Infrared Spectroscopic Ellipsometry

BEST PRACTICES REPORT. Tank Car Lessee PROJECT OVERVIEW: Industrial Customer: A chemical company.

Flexible Hybrid Systems: High Performance CMOS with Printed Electronics

University Of Oregon Additional Specifications

GN002 Application Note Thermal Design for GaN Systems Top-side cooled GaNPX -T packaged devices

INTERNATIONAL 300 mm INITIATIVE

IME TSI Consortium Industry Forum

Overview of SOI development (from the HEP perspective)

Force Sensing Resistor Technical Guidelines Rev 0 ( ) by M. Wagner

Your Super Pillar MCPCB Thermal Management Solution Supplier.

FP1008R5 and FP1008R6 High frequency, high current power inductors

Non-volatile STT-RAM: A True Universal Memory

Bridgelux Vero SE 29 Array Series. Product Data Sheet DS123

Bridgelux Vero SE 29 Array. Product Data Sheet DS123

Motor Driver PCB Layout Guidelines. Application Note

Crimpmate Range pitch 5.00

2015 June NEW PRODUCTS / MAXXIMA. Hybrid LightningS PAGE 5 Low Profile 4 PAGE 2 MWL-31SP PAGE 3 M20344 PAGES 6

Bridgelux Vero SE 29 Array Series. Product Data Sheet DS123

Product Management, ABB Robotics

Series CP95. Profile Design ISO/VDMA Air Cylinder. Increased kinetic energy absorption. Improved end of stroke cushion capacity

ONICON Insertion Turbine Flow Meters Single Turbine vs. Dual Turbine Selection Criteria

ReRAM Technology, Versatility, and Readiness

06. har-mik INTERFACE CONNECTORS

ALS20000 Series. Mechanical Bearing, Linear Motor Stage. Protective metal waycover. Integral cable management system

SE 300 Solder Paste Inspection System Gauge Repeatability and Reproducibility Procedure and Results

Automotive. 3M Dual Lock Reclosable Fasteners with Pressure Sensitive Adhesive

Devices and their Packaging Technology

MPC8270, MPC8275, MPC8280 Product Information:

Embedded Components: A Comparative Analysis of Reliability

Mini-MAG Positioning Products

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

74x Series Chip Resistor Arrays

ALS20000 Series. Mechanical Bearing, Linear Motor Stage. Protective metal waycover. Integral cable management system

Automotive Micro and Mild Hybrids

Product Specification YEEMMP98 Series

Mounting Instruction for M629 Package (EconoPACK TM + Module)

Versatile Z-Axis Interconnection-Based Coreless Technology Solutions for Next Generation Packaging

ACTUATOR LA30 PRODUCT DATA SHEET

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

Precision Modules PSK

Preliminary Results of 25 ns Test Beam on Florence Detector. Simone Busoni - INFN Firenze for CMS Florence group

Power-Limiting Cables

brochure PN

Automotive Technology

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

Robot Leg Motion in a Planarized-SOI, 2-Poly Process Hilton Head 2002

ALD3 Diaphragm Valve Technical Report

ACTUATORS POSITION SENSOR

Thermal Characterization and Modeling: a key part of the total packaging solution. Dr. Roger Emigh STATS ChipPAC Tempe, AZ

Wind Turbine Emulation Experiment

Description The APR SRS-CALKIT is a thermal calibration kit for the APR Scorpion Rework System. It is compatible with the following item numbers:

SURFACE TOPOGRAPHY ANALYSIS OF PRECISION ASSEMBLIES OF FUEL INJECTOR NOZZLES

/2008 Altivar 12P Baseplate variable speed drives for asynchronous motors Installation manual 09/2009 V28587 B B

MultiGig RT Product Family Slot Pitch Density Data Rate RT lines/inch Gbps lines/inch Gbps RT lines/inch 6.50 Gbp

A Novel Non-Solder Based Board-To-Board Interconnection Technology for Smart Mobile and Wearable Electronics

SECTION Front Drive Axle/Differential

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

Bridgelux Gen 7 Vero 29 Array. Product Data Sheet DS93

A fully integrated 3 phase IGBT switching assembly with a very low loss DC Link Capacitor -- Ed Sawyer, SBE Inc. Scott Leslie, Powerex Inc.

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #6: Magnetic Fields

Large Area and Fine Pitch testing using Silicon Micro-cantilever

Si trim applications: benefits and challenges

High Current, High Frequency Power Inductors HCM1103 Series

GLASS TRANSITION TEMPERATURE (Tg) 65 C >2, , C >2, , C >2, , C 1, ,918 1.

Advanced Topics. Packaging Power Distribution I/O. ECE 261 James Morizio 1

Design-Technology Co-Optimization for 5nm Node and Beyond

Bridgelux Vero 29 Array Series. Product Data Sheet DS93

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Overview of Magnetic Measurement Activities at SLAC National Accelerator Lab (SLAC)

9 rue Alfred Kastler - BP Nantes Cedex 3 - France Phone : +33 (0) website :

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

GROUNDING & BONDING PRODUCTS

Low-Profile, Shielded Drum Core, Tapped Inductor SDT30 Series

Building Innovative and Successful Industrial Scale Biomass Supply Chain Solutions Sam Jackson May 15, 2014

The ITk strips tracker for the phase-ii upgrade of the ATLAS detector of the HL-LHC

Installation design data for the 500SFK series fuse

Transcription:

ATR35 Wafer Specification SKW ASSOCIATES, INC. 3370 Victor Court, Santa Clara, CA 95054 Tel: 408-919-0094, Fax: 408-919-0097

Sematech 754 Layout Sematech 754 Documentation Samsung dishing structure Sematech dishing structures The typical Sematech dishing structure used is the 100/100 array

ATR35 Description Reduction in critical dimensions Minimum metal line width: 60nm Via sizes down to 80nm ATR35 Capabilities Key BU s : All Via chains with up to ~10 million vias Via chain Guard rings ATR30 (trenches) 140nm ATR35 100nm M2 Expanded and improved set of reliability testers Guard rings added to prevent low-k moisture adsorption V1 M1 Structures down to 45nm node

ATR35 Layout Note the CMP test structures highlighted in light brown ATR35 Layout

ATR M1 Film Stack 800A +/- 100A Cu Seed + 5000A +/- 500A ECP (Total = 5.8KA) 2500A +/- 250 A Coral 500A +/- 50 A USG Cap 150A NDC + 250A ESL3 (Etch Stop) 10000A +/- 500A SiO2 100A TaN + 200A Ta Barrier CMP Target: Remove USG Cap + 200A Coral ATR35 only available with Coral films

ATR Process Flow (up to M1 CMP)

ATR Test Structures Topography test structures Fang test structures Electrical test structures

Typical CIC Profilometry Locations New profilometry recipe was created to measure large and small E-test comb/serp structures in addition to CMP test structures. New structures profiled: 1. CMB_SRP_LRL_M1 2. CMB_SRP_SRL_M1 CMP test structures profiled: 3. FANG1 single line structures 4. FANG2 small pitch arrays 3 4 2 1

Serp/Comb Scan Locations CMB_SRP_SRL_M1 DUTs 5 & 6 scanned (140x140 nm) CMB_SRP_LRL_M1 DUTs 11 & 12 scanned SERPs (140x140 nm, 180x180 nm)

CMB_SRP_SRL_M1 Surface Profile Scan EOE EOE 46 114 83

CMB_SRP_LRL_M1 Surface Profile Scan EOE EOE 75 311 265

CMP Test Structure Scan Locations FANG1 200 um 100 50 20 10 5 2 1 0.5 0.2 FANG2 10um/ 10um 5um/ 5um 1um/ 1um 0.2um/ 0.2um 2um/ 2um 0.5um/ 0.5um

Topo Test Structures

M1 backbone 10um C M P C h a r a c t e r I z a t I o n S o l u t I o n s CMP Topo Tester (in place of via_chn_250_m3_upper) Probe Alignment structure ~250um space around all sections between sections M2 comb ~700um M2 comb.14 l/s (10 um backbone) 1 2 3 4 5 6 7 8 9 10 Section # 250um space between sections M1 topo sections (750 um vertical trenches /spaces)

M1 topo C M P C h a r a c t e r I z a t I o n S o l u t I o n s ATR35 CMP Topo Tester (in place of via_chn_250_m3_upper) CMP Topography tester (replace via_chn_250_m3 in top portion) tester width (mm) 5.58 0.25 mm space between sections M1 topo (no vias) M2 comb 140nm trench/140nm sp perpendicular to test for shorts (see ppt diagram) section trench space pitch metal tester x dim total x dim # repeats (nm) (nm) (nm) density (mm) (mm) y-dim (um) 1 90000 90000 180000 0.5 4 0.720 1.22 750 2 90000 10000 100000 0.9 7 0.700 2.17 750 3 10000 0.5 1 0.020 2.44 750 4 10000 10000 20000 0.5 14 0.280 2.97 750 5 9000 1000 10000 0.9 27 0.270 3.49 750 6 2250 0.5 1 0.005 3.74 750 7 2250 2250 4500 0.5 61 0.275 4.27 750 8 2250 250 2500 0.9 110 0.275 4.79 750 9 250 250 500 0.5 550 0.275 5.32 750 10 250 250 500 0.5 7 0.004 5.57 750 Use a scaled version of this pattern as the topo sections under combs/serps (CS topo) use horizontal trenches in these testers Section 1 750um long 250um Section 2

CMP_TOPO_Tester Metal 1 Metal 2 Pad 10um 9um/ 1um 2.25/2.25 0.25/ 0.25 750 µm 90um/ 90um 90um/ 10um 10um/ 10um 2.25um 2.25/ 0.25 0.25/0.25 No of Lines: 4 7 1 14 27 1 61 110 545 7 Metal 2 COMB: 0.14 um / 0.14 um L/S

CMP Pad Tester left border left sections density trench space height pitch # repeats width left side testers 250 top border 0 0 200 0 250 1 left 9.9 0.11 1 250 1.11 225 249.75 250 space 0 0 200 0 0 250 2 left 50 1 1 250 2 125 250 250 space 0 0 200 0 0 250 3 left 90 9 1 250 10 25 250 250 space 0 0 200 0 0 250 4 left 99 49 1 250 50 5 250 250 bot border 0 0 200 0 0 total 2000 Right side testers space (between lt & rt sect) right sections density trench space pitch # repeats width right border 234 space 0 0 250 234 1 right 100 250 0 250 1 250 250 234 space 0 0 0 0 250 234 2 right 50 0.2 0.2 0.4 625 250 250 234 space 0 0 0 0 250 234 3 right 90 1.8 0.2 2 125.000 250 250 234 space 0 0 0 0 250 234 4 right 99 9.8 0.2 10 25 250 250 234 space 0 250 Large pad Get Topo vs. Pattern Density and Line Width

CMP Pads at Metal 1 500 µm 0.2um/ 0.2um 1.8um/ 0.2um 9.8um/ 0.2um 500 µm 0.11um/ 1um 1um/ 1um 9um/ 1um 49um/ 1um 500 µm Dense and Iso pad structures

CMP Pad Testers 4 pads measured in 1 trace Profilometer traces

Fang Test Structures

CMP Fang Tester Diagram 120µm x 120µm bond pads, 155µm pitch M2 comb 0.20µm l/s, height of each 100µm 50µm A 100µm 50µm CMP topography structures 100µm 50µm B 100µm 50µm 950µm (max M1 structure 910µm) 100µm 50µm C 100µm 1300µm (max M1 structure 1200µm) Use A, B, C for fang structures 1, 2 and 3 Use B for fang structure 4

CMP Fang Testers Metal 2 COMBs over Metal Topography: Metal 2 COMB dimensions: 0.2 µm line / 0.2 µm space Metal 1 topography dimensions: see each page for detail. Metal 1 Metal 2 Pad

CMP Fang 1 Tester 200 um 100 50 20 10 5 2 1 0.5 0.2 20/ 20 10/ 10 5/ 5 2/ 2 1/1 0.5/0.5 0.2/0.2 20/ 20 10/ 10 5/5 2/ 2 1/1 0.5/0.5 0.2/0.2 The unit is um.

CMP Fang 2 Tester 10um/ 10um 5um/ 5um 2um/ 2um 200 um 1um/ 1um 0.5um/ 0.5um 0.2um/ 0.2um 10um/ 10um 5um/ 5um 1um/ 1um 0.2um/ 0.2um 2um/ 2um 0.5um/ 0.5um

CMP Fang 3 Tester 90um/ 10um 45um/ 5um 18 um/ 2um 200um 9um/ 1um 4.5um/ 0.5um 1.8um/ 0.2um 90um/ 10um 45um/ 5um 18um/ 2um 9um/ 1um

CMP Fang 4 Tester 500 µm 500 µm

E-Test Structures

CMP Tester Layout Dummy Pattern Resistor (Cu line) Measure impact of dummy pattern on line resistance (dishing / erosion) Each device (DUTs) has different dummy pattern or line width

ATR35 - CMP Resistance Testers Pattern ~400um wide each side proximity resistor Voltage tap Topo @m1 1 device (6 variations + 1 VDP per test module)

ATR35 - CMP Resistance Testers Topo Pattern lines /spaces~200um wide each side @m1 (in 1 m2 tester only) resistor Resistor to pattern space pattern space pattern trench Voltage tap 1 device (6 variations) + 1 VDP per test module)

ATR35 - M1 CMP Resistance Testers CMP_M1_a (replace CMP_m1_top section) length lines = 750um width in um width in um width in um width in um width in um width in um DR Description VDP DUT1 DUT2 DUT3 DUT4 DUT5 DUT6 1 Resistor line-width 0.2 0.2 0.2 0.2 0.2 0.2 2 Resistor to pattern line spacing 0.2 0.2 0.2 0.2 0.2 0.2 3 Pattern line-width 1 0.2 10 50 200 90 4 Pattern spacing 0 0.2 10 0 0 10 5 # pattern l/s on each side of resistor 1 500 10 1 1 2 6 total width (um) 2.6 401 401 101 401 401 7 resistor line length 600 600 600 600 600 600 8 pattern density <1 50.00 50.00 99.00 99+ 90.00 9 VDP line width 10 iso fang dishing dishing CMP_M1_b (replace CMP_M3_ top section) DR Description VDP DUT1 DUT2 DUT3 DUT4 DUT5 DUT6 1 Resistor line-width 10 10 10 10 10 10 2 Resistor to pattern line spacing 0.2 10 0.2 0.2 10 3 Pattern line-width 0.2 10 10 90 90 4 Pattern spacing 0.2 10 10 10 10 5 # pattern l/s on each side of resistor 0 488 9 10 2 2 6 total width (um) 10 401 390 410 410 430 7 resistor line length 600 600 600 600 600 600 8 pattern density <1 50.00 50.00 50.00 90.00 90.00 9 VDP line width 50 iso fang dishing dishing

ATR35 M2 CMP Resistance Testers CMP_M2_a (replace CMP_m2_top section) length lines = 750um width in um width in um width in um width in um width in um width in um DR Description VDP DUT1 DUT2 DUT3 DUT4 DUT5 DUT6 1 Resistor line-width 0.2 10 0.2 10 0.2 10 2 Resistor to pattern line spacing 0.2 4.9 10 0.2 0.2 3 Pattern line-width 0.2 10 10 200 90 4 Pattern spacing 0.2 10 10 0 10 5 # pattern l/s on each side of resistor 0 488 10 9 1 2 6 total width (um) 0.2 401 410 390 401 410 7 resistor line length 600 600 600 600 600 600 8 pattern density <1 <1 50.00 50.00 98.00 90.00 9 VDP line width 10 iso iso fang fang dishing dishing CMP_M2_b - with underlying topo (replace CMP_M2 in bottom section) DR Description DUT1 DUT2 DUT3 DUT4 DUT5 DUT6 1 Resistor line-width 0.2 0.2 0.2 10 10 10 2 Resistor to pattern line spacing 0.2 0.2 0.2 0.2 0.2 0.2 3 Pattern line-width 0.2 0.2 0.2 0.2 0.2 0.2 4 Pattern spacing 0.2 0.2 0.2 0.2 0.2 0.2 5 # pattern l/s on each side of resistor 500 500 500 488 488 488 6 total width (um) 401 401 401 401 401 401 7 resistor line length 600 600 600 600 600 600 8 pattern density 50.00 50.00 50.00 50.00 50.00 50.00 9 M1 topo (l/s) - horizontal.2/.2 10/10 90/10.2/.2 10/10 90/10 10 VDP 50

CMP Pad Tester Diagram - different pattern in each pad Horizontal trenches spaces in each section Left border 1L 1R Right border Space between right sections 2L 2R Space between left and right sections 250um x 250 um pads

Recommended ATR35 Structure The structure on ATR35 which most closely matches the 100/100 structure on Sematech is the 90/90 structure Refer to slide 13

CMP_TOPO_Tester 90um/90um Line Profile

CMP_TOPO_Tester 90um/90um Line Profile

CMP_TOPO_Tester 90um/90um Line Profile

ATR35 Summary Design rules at 140nm and 90nm Multiple CMP test physical and electrical test structures

CMP_FANG1 Die Floor Plan 100 50 20 10 5 2 1 0.5 0.2 200 um 20/20 10/10 5/5 2/2 1/1 0.5/0.5 0.2/0.2 20/20 10/10 5/5 2/2 1/1 0.5/0.5 0.2/0.2

CMP_FANG1 Row 1 Line Profile

CMP_FANG1 Row 1 Line Profile L1 L2 L3 L4 L5 L6 L7 L8 L9 L1 L2 370 309 L3 L4 148 90 L5 L6 L7 L8 L9 67 48 36 23 6

CMP_FANG1 Die Floor Plan 100 50 20 10 5 2 1 0.5 0.2 200 um 20/20 10/10 5/5 2/2 1/1 0.5/0.5 0.2/0.2 20/20 10/10 5/5 2/2 1/1 0.5/0.5 0.2/0.2

CMP_FANG1 Row 2 Line Profile

CMP_FANG1 Row 2 Line Profile A1 A1 A2 A2 A3 A4 A3 A4 A5 A5 A6 A6 A7 A7 A1 A1 A2 A2 A3 A3 A4 228 18 180 18 112 36 70 27 60 17 43 9 27 4 A4 A5 A5 A6 A6 A7 A7

CMP_FANG1 Die Floor Plan 100 50 20 10 5 2 1 0.5 0.2 200 um 20/20 10/10 5/5 2/2 1/1 0.5/0.5 0.2/0.2 20/20 10/10 5/5 2/2 1/1 0.5/0.5 0.2/0.2

CMP_FANG1 Row 3 Line Profile

CMP_FANG1 Row 3 Line Profile A1 A1 A2 A2 A3 A3 A4 A5 A4 A5 A6 A6 A7 A7 A1 A1 A2 A2 A3 A3 A4 A4 A5 A5 A6 A6 A7 A7 211 35 170 19 136 18 73 9 48 9 26 8 13 6

CMP_FANG2 Die Floor Plan 10um/ 10um 5um/ 5um 2um/ 2um 200 um 1um/ 1um 0.5um/0.5um 0.2um/ 0.2um 10um/ 10um 5um/ 5um 2um/ 2um 1um/ 1um 0.5um/ 0.5um 0.2um/ 0.2um

CMP_FANG2 Row 1 Line Profile

CMP_FANG2 Row 1 Line Profile Array 1 Array 1 Array 2 Array 2 Array 3 Array 3 Array 1 (A) Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) 182 18 142 48 126 64

CMP_FANG2 Die Floor Plan 10um/ 10um 5um/ 5um 2um/ 2um 200 um 1um/ 1um 0.5um/0.5um 0.2um/ 0.2um 10um/ 10um 5um/ 5um 2um/ 2um 1um/ 1um 0.5um/ 0.5um 0.2um/ 0.2um

CMP_FANG2 Row 2 Line Profile

CMP_FANG2 Row 2 Line Profile Array 1 Array 1 Array 2 Array 2 Array 3 Array 3 Array 1 (A) Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) 87 78 55 86 36 95

CMP_FANG2 Die Floor Plan 10um/ 10um 5um/ 5um 2um/ 2um 200 um 1um/ 1um 0.5um/0.5um 0.2um/ 0.2um 10um/ 10um 5um/ 5um 2um/ 2um 1um/ 1um 0.5um/ 0.5um 0.2um/ 0.2um

CMP_FANG2 Row 3 Line Profile

CMP_FANG2 Row 3 Line Profile A1 A1 A2 A2 A3 A3 A4 A4 A5 A5 A6 A6 A1 A1 A2 A2 A3 A3 A4 A4 A5 A5 A6 A6 203 13 110 38 110 26 78 12 52 15 30 12

CMP_FANG3 Die Floor Plan 90um/ 10um 45um/ 5um 18um/ 2um 200 um 9um/ 1um 4.5um/ 0.5um 1.8um/ 0.2um 90um/ 10um 45um/ 5um 18um/ 2um 9um/ 1um

CMP_FANG3 Row 1 Line Profile

CMP_FANG3 Row 1 Line Profile Array 1 Array 1 Array 2 Array 2 Array 3 Array 3 Array 1 (A) Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) 419 35 397 12 397 18

CMP_FANG3 Die Floor Plan 90um/ 10um 45um/ 5um 18um/ 2um 200 um 9um/ 1um 4.5um/ 0.5um 1.8um/ 0.2um 90um/ 10um 45um/ 5um 18um/ 2um 9um/ 1um

CMP_FANG3 Row 2 Line Profile

CMP_FANG3 Row 2 Line Profile Array 1 Array 1 Array 2 Array 2 Array 3 Array 3 Array 1 (A) Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) 348 25 342 33 311 46

CMP_FANG3 Die Floor Plan 90um/ 10um 45um/ 5um 18um/ 2um 200 um 9um/ 1um 4.5um/ 0.5um 1.8um/ 0.2um 90um/ 10um 45um/ 5um 18um/ 2um 9um/ 1um

CMP_FANG3 Row 3 Line Profile

CMP_FANG3 Row 3 Line Profile Array 1 Array 1 Array 2 Array 2 Array 3 Array 3 Array 4 Array 4 Array 1 (A) Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) Array 4 (A) Array 4 (A) 415 30 313 34 303 48 280 56

CMP_FANG4 Die Floor Plan 500 um 500 um

CMP_FANG4 Row 1 Line Profile

CMP_FANG4 Row 1 Line Profile (A) (A) 692 30

CMP Pads at Metal 1 500 um 0.2um/ 0.2um 1.8um/ 0.2um 9.8um/ 0.2um 500 um 0.11um/ 1um 1um/ 1um 9um/ 1um 49um/ 1um 500 um

CMP Pads Row 1 Line Profile

CMP Pads Row 1 Line Profile Array 1 Array 3 Array 3 Array 4 Array 2 Array 2 Array 4 Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) Array 4 (A) Array 4 (A) 335 36 95 180 21 292 34

CMP Pads at Metal 1 500 um 0.2um/ 0.2um 1.8um/ 0.2um 9.8um/ 0.2um 500 um 0.11um/ 1um 1um/ 1um 9um/ 1um 49um/ 1um 500 um

CMP Pads Row 2 Line Profile

CMP Pads Row 1 Line Profile Array 3 Array 3 Array 4 Array 4 Array 1 Array 1 Array 2 Array 2 Array 1 (A) Array 1 (A) Array 2 (A) Array 2 (A) Array 3 (A) Array 3 (A) Array 4 (A) Array 4 (A) 59 4 50 10 247 17 349 40

CMP_M1_A C M P C h a r a c t e r I z a t I o n S o l u t I o n s CMP_M1_B 2 x L50 µm 2 x L50 µm Array L2.0 µm / S2.0 µm 4 x L90 µm / S10 µm Array L2.0 µm / S2.0 µm 4 x L90 µm / S10 µm 2 x L1.0 µm Array L10 µm / S10 µm 2 x L200 µm Square feature 2 x L1.0 µm Array L10 µm / S10 µm 2 x L200 µm CMP_M1_B and CMP_M1_A have same array dimensions. CMP_M1_B has a square feature, as is shown above, whereas CMP_M1_A does not. CMP_M1_A exhibits a greater amount of dishing after CMP, as is shown on the following pages.

2 x L50 um Structure 2 x L50 µm Array L2.0 µm / S2.0 µm 4 x L90 µm / S10 µm CMP_M1_A 2 x L50 Profile CMP_M1_A shows 18% more dishing Array L10 µm / S10 µm 2 x L1.0 µm 2 x L200 µm Note: Graphs not to scale CMP_M1_B 2 x L50 Profile

4 x L90 / S10 um Structure 2 x L50 µm Array L2.0 µm / S2.0 µm 4 x L90 µm / S10 µm Array L10 µm / S10 µm CMP_M1_A 2 x L90/S10um Profile CMP_M1_A shows 11% more dishing than CMP_M1_B 2 x L1.0 µm 2 x L200 µm Note: Graphs not to scale CMP_M1_B 2 x L90/S10um Profile

2 x L200 um Structure 2 x L50 µm Array L2.0 µm / S2.0 µm 4 x L90 µm / S10 µm Array L10 µm / S10 µm CMP_M1_A 2 x L200 Profile CMP_M1_A shows 22% more dishing than CMP_M1_B 2 x L1.0 µm 2 x L200 µm Note: Graphs not to scale CMP_M1_B 2 x L200 Profile

L10 µm/ S10 µm Array Structure 2 x L50 µm Array L2.0 µm / S2.0 µm 4 x L90 µm / S10 µm Array L10 µm / S10 µm CMP_M1_A L10um/S10um Profile CMP_M1_A shows 18% more dishing than CMP_M1_B 2 x L1.0 µm 2 x L200 µm Note: Graphs not to scale CMP_M1_B L10um/S10um Profile