CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

Similar documents
KEY FEATURES TEST CAPABILITIES STANDARDS COMPLIANCE

Digital Insulation Resistance Testers. you can depend on

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

7007 Loop Mate 2 Loop / Voltage / Current Simulator

For all of your Ground T esting needs. Technical Hotline: (800) Ground Testers

DLRO10HDX 10 Amp Digital Low Resistance

HUMIDITY / TEMPERATURE TRANSMITTER

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

TnP-500 Series. Test n Print Units. Wavecom Instruments

OWNER S MANUAL Please read this manual before operating your power supply

Application. Battery. Public Grid GS HYBRID INVERTER

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Hillstone PowerBank HPB54 Series ( 400A 700A )

Digital/Analog Megohmmeter Model 1026 USER MANUAL

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

EPS/ELA-Series User Manual EPS/ELA 250W

Three Phase UPS Systems Range: 10 to 500kVA

Fluke 500 Series Battery Analyzers

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Digital/Analog Megohmmeter Model 1026

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

PAT120, PAT150 and PAT150R

Advanced Test Equipment Rentals ATEC (2832)

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

ALL-TEST PRO 5. The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes! Motor Circuit Analyzer

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Cellwatch Battery Monitoring Systems

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Ground Resistance Tester Model 3620 & 3620 Kits

1.Safe testing IMPORTANT:

MOM2 Handheld High Current Micro-ohmmeter

Technical Specification SENTINEL PRO

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

MJÖLNER 200 Microhmmeter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Portable Surge Protective Device Tester SPD T8 tester User Manual

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

TENSION LOAD. Product Overview

Multifunction Electronic Load (EBC-A10) User Manual EBC-A10 User Manual Copyright (C) ZKE Technology

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

SafetyPAT Plus A B P/N:

Description 1/8-7.5HP

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

HD110C Heavy-Duty Digital Multimeter

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Harris IRT Enterprises Digital Resistance Tester Model XP

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

OPERATING INSTRUCTION

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications

MIT515, MIT525, MIT1025, MIT1525

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Dawson DDM190D. Digital Multimeter User s Manual

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

INTECH Micro 2300-RTD6

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Power Conversion. Battery Chargers. Model

Qingdao Zener Electric Co., Ltd

POWER ACCESSORIES SOCKET ASSEMBLIES CIGARETTE LIGHTER PLUGS BATTERY DISCHARGE PROTECTOR VOLTAGE REDUCERS VOLTAGE CONVERTER VOLTAGE BOOSTER INVERTERS

S1-568, S1-1068, S1-1568

EA / 10 / 50 Clamp Coil Adapter. Operation Manual. Version 1.00 April 2007 All product names are trademarks of their respective companies

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Battery Fuel Gauge Specification

DIGITAL MICROHMMETER TYPE DO7

Phoenix Inverter

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

Multi-Function Ground Resistance Tester Model 6472

Identifying the Motorized RGS part number codes when ordering

Duo Battery Charge Controller

MOM2 Microhmmeter. MOM2 Microhmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

ABB component drives ACS150, 0.5 to 5 Hp

KEWTECH. KT56 digital multi function tester. Instruction manual

Hand Held Pull Tester Instruction Manual Order No

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Motive Power Solutions

Standalone Linear Li-Ion Battery Charger with Thermal Regulation

AMS Amp LOW DROPOUT VOLTAGE REGULATOR. General Description. Applications. Typical Application V CONTROL V OUT V POWER +

Volt/mA Calibrator. Manual

BATTERY OPERATED DIGITAL MILLI-OHMMETER

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Advanced Monolithic Systems

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User's Manual. Earth Ground Resistance Tester. Model Introduction

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

operating manual DL7 101 DIGITAL THERMOMETER

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Micro Dyne Motor Testing System

DELTA4000 Accessories

Choose the future Choose

Transcription:

ECT-4 DATASHEET CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES Excellent mobility Single handed operation Extended operating time Three discrete current injection levels Continuous & pulsed current direction modes REDPHASE INSTRUMENTS 1

Contents Section Key Features Application... 1 Where it is used... 1.1 Components... 2 Base Unit... 2.1 Main Earth / Ground Lead... 2.2 Pistol Grip Probe... 2.3 Hardware & Performance... 3 Power Source... 3.1 Power consumption - Standby.. 3.2 Power consumption - Under Load.... 3.3 Accuracy... 3.4 Noise and frequency rejection... 3.5 AC rms Voltage rejection during DC test... 3.6 Current direction mode... 3.7 Current Levels and Load limit... 3.8 Reference check... 3.9 Discharge Time... 3.10 Charge Time... 3.11 Battery Pack Protection Specification.. 3.12 Temperature Specification.. 3.13 Thermal Drift 3.14 Fan Operation.. 3.15 Accessories... 4 Enclosure 5 Cases... 5.1 Case Sizes (L x W x H)... 5.2 Weight... 5.3 Warranty... 6 RED PHASE INSTRUMENTS PTY. LTD. ABN 47 005 176 670 10 Ceylon Street, Nunawading, Melbourne, Victoria, 3131, Australia Tel: + 61 3 9877 6988 Fax: + 61 3 9878 8508 E-mail: sales@redphase.com.au 2

KEY FEATURES: The ECT-4, (Earth Continuity Tester V4) is a low resistance micro-ohmmeter used to test the electrical integrity of metal structures, electrical connections and grid bonded utility assets in small or large electrical systems such a single transformer sub to larger extended grids such as a transmission station or industrial complex. Such structures include the bonded electrical equipment itself and / or peripheral elements such as a station s fencing and equipment barriers. The ECT-4 comes with the following: One base unit or main current source housed in a tough ABS case One ABS moulded pistol grip probe which includes a control & display panel, two retractable spring loaded stainless steel pins and a connecting fly lead One lithium battery pack & connecting cable Lithium battery pack charger One reference resistor block for field calibration check One 10 metre / 33 foot two-way main earth cable One 100 metre / 330 foot two-way main earth cable on a canvas or cloth reel One custom carry pack or back pack The carry pack contains cable guides, hook loops, and compartments for the base unit, a battery pack and the test probe. The carry pack allows the base unit to connect to the battery pack, the main earth cable and the test probe via a compartment gap at the base of the carry pack. This gives the operator total portability without being encumbered by a mains extension cable or to have to carry the base unit with the other hand. The carry pack also allows the operator freedom of movement around an electrical network while performing electrical continuity tests. With three different current range settings to choose from, field testing with the ECT-4 can last for over five (5) hours on one battery pack. The test probe s LCD display and control panel allow the operator to perform all of the tests with one hand freeing up the other hand for note taking or performing other tasks. The test probe provides the following test information and physical features: Resistance reading Applied current reading Battery status indicator Three push buttons to set the different test modes and current injection level Has a type A USB input for future software updates if so required Spring loaded stainless steel pins which compress and rotate when pressed onto a metallic asset, making for easier connection to structures through corroded and painted surfaces.

1.0. APPLICATIONS 1.1. Where it is used The Model ECT-4 is a lightweight field portable instrument designed to test the integrity of buried conductors and remotely connected structures in and around a grid connected or grounded Electrical or Industrial complex. Types of structures which may be tested: Transformers Poles / Towers Fencing Equipment barriers It s ideally used to map the continuity of these grid bonded structures prior to performing an earth or ground system current injection test. please refer to our Earth Testing products at www.redphase.com.au for more information 2.0. COMPONENTS The ECT-4 kit of components: 2.1. Base Unit Housed in a rugged ABS case, it contains the main current source, a fan, the source switch, probe connector, main earth connector, battery pack connector and a USB interface for firmware upgrades when required. 2.2. Main Earth / Ground Lead A twin core 1 mm 2 cable is provided in 2 lengths. This cable carries one half of the 4 wire Kelvin connection from the Base Unit to the earthed grid. One end has a 4 way Amphenol connector for connection to the base unit and the other end has two crocodile clips for earth bar or grid connection. A 10 metre or 33 ft main earth cable is provided for smaller grounded or grid system while a 100 metre or 330 ft reel is provided for larger extended earth or bonded grid systems. To maintain proper regulation of drive current up to a maximum of 3 Amps, the connecting lead between the Base Unit and the grid connection must be limited to a loop resistance of 8 Ω or less. 2.3. Test Probe This pistol grip probe has two retractable stainless steel contact pins which rotate when compressed. The probe has a custom moulded body made from rugged ABS plastic and comes with a 1.5m lead which connects directly to the base unit. The probe has a 102 x 64 FSTN graphic display and back light which displays test point data and settings such as current, resistance, battery level, current direction setting and manual or automatic current settings. Also, three tactile buttons located beneath the display allows the operator to adjust the ECT-4 s test settings and parameters. 3.0. HARDWARE & PERFORMANCE 3.1. Power Source One 14.4V / 3200mAH lithium battery pack is provided with the ECT-4 kit. The battery comes in a customized enclosure and includes both over-charge and over-discharge protection circuitry. A customized battery tamper protection circuit has also been added to mitigate effects of potential misuse such as a short circuit, battery overload and heat stress. When fully charged the battery pack voltage can often start off as high as 16.6 Vdc however once connected to the ECT-4 base unit the voltage will reduce within 10 minutes to and average of 13.3 Vdc where it shall remain stable for over 90% of the ECT-4 s field operation. The consumption figures given below are based on this average battery level. The battery pack is considered to be fully discharged when the battery level falls to 10.5 Vdc. At this voltage the in-built protection circuit will electrically disconnect the battery from the ECT-4 to spare the battery from being over-discharged. Important note: this battery pack is non-serviceable 3.2. Power consumption - Standby The current source and the measurement circuit is comprised of the Base unit and the Probe. The probe s LCD backlight and base unit fan remained on at all times during the consumption tests below. Standby Vdc Idc Power Base Unit 13.3 V 340 ma 4.52 W Probe 13.3 V 60 ma 0.8 W Total 13.3 V 400 ma 5.32 W Based on these figures it is estimated that the battery pack is capable of maintaining the ECT-4 in standby mode for at least 24 hours before a new battery pack or re-charge is required. 3.3. Power consumption - Under Load The consumption figures shown below indicate the ECT-4 system s total consumption at applied current across a 1Ω resistive load. Vdc Idc Load Power 13.3 V 1 A 1 Ω 18.6 W 13.3 V 2 A 1 Ω 32 W 13.3 V 3 A 1 Ω 45 W Consumption test above performed with 100m main earth cable 4

3.4. Accuracy Accuracy: ± 0.05% with respect to full scale Output current accuracy: ± 2% Measured current stability under load: < 10ppm/s Please note that to achieve the typical accuracy figures listed above the probe must be applied to the bonded structure for at least 3 seconds. Range Display Resolution 0 to 200 mω 0.00-200.00 mω 10 µω 200 mω to 4 Ω 0.2001-4.0000 Ω 100 µω 3.5. Noise and frequency rejection ECT-4 has a very precise filter at both 50Hz and 60Hz achieving a signal attenuation of 100dB. Also, the analogue to digital conversion of the measured voltages are set well above the noise floor to maintain higher signal to noise (S/N) ratio. To maintain a consistently high S/N ratio it is recommend that the Automatic current range setting be used only. If the operator chooses to use the Manual current setting the table below must be used as a guide to set the optimal current injection level for the ohmic values shown here. Note: current range entry can only be made when the ECT-4 is set to Manual mode. In both manual and automatic modes the ECT-4 will attempt to inject the maximum level of current up to the chosen level or to the most suitable level of test current that is not limited by the external load, the supply and heat dissipation factors. 3.6. ACrms Voltage rejection during DC test Table below shows the maximum tolerable 50Hz induced AC voltage across a 1 Ω load which the ECT-4 can accurately measure before a drift in the order of 1 mω or more begins to occur. ECT-4 IDC Range Injected IAC r.m.s. Current Setting 0 to 200 mω 2A or 3A 200 mω to 1.2 Ω 1A, 2A or 3A 1.2 Ω to 2 Ω 1A or 2A 2 Ω to 4 Ω 1A Load Induced VAC r.m.s. 1 A 4.0 Aac 1 Ω 4 Vac 2 A 4.9 Aac 1 Ω 4.9 Vac 3 A 5.2 Aac 1 Ω 5.2 Vac Please Note: Maximum tolerable non-destructive induced 50Hz / 60Hz AC Voltage: VAC r.m.s. < 10V 3.7. Current direction mode To further mitigate noise, signal coupling and d.c. bias, the operator may change or cycle the direction of the current source as shown below. Two current injection modes are available for the operator to choose from on the ECT-4 Probe. i. Continuous mode Forward D.C.: Continuous current applied in the forward direction displayed as: -or- Reverse D.C.: Continuous current applied in the reverse direction displayed as: ii. Pulse mode Off + Off + Forward Pulse Current: Current is supplied for a set ON period in the forward direction and a set OFF period. Displayed as: -or- - Off - Off Reverse Pulse Current: Current is supplied for a set ON period in the reverse direction and a set OFF period. Displayed as: -or- Bipolar: - + - + Current applied in both forward and reverse directions in bipolar mode with preset ON intervals for each direction. Displayed as: Note: In Pulse mode the pulse ON times are set to a minimum of two seconds to achieve a stable reading, however the forward and reverse ON & OFF times may also be adjusted independently in 1 second increments up to 999 seconds to achieve asymmetric readings if required. 3.8. Current Levels and Load limit reading The table in section 3.5 shows the measurable load limits for each current range. When using the manual current setting the operator must be aware that the choice of current range and the maximum measurable load may be limited by the main earth cable s lengthwise resistance. The ECT-4 kit is supplied with two 1mm 2 two way cable lengths for the main earth connection. A 10 metre or 33 foot main earth cable with an average loop resistance of: 0.172 Ω. A 100 metre or 330 foot main earth cable with an average loop resistance of: 1.72 Ω 3.9. Reference Check The ECT-4 is supplied with a factory certified 1 Ω resistive reference block which the operator can use to check the ECT-4 s performance before a field test commences. + - 5

3.10. Battery Discharge Time Table i below shows the time taken for the ECT-4 to fully discharge the 14.4V, 3200mAh battery pack when a continuous forward d.c. current is applied across a 1.0Ω resistive load. Table i Continuous Current Table ii. below shows the time taken to fully discharge the battery pack when continuously applying a three second pulsed forward ON current and a three second OFF pulse across a 1.0Ω resistive load. Table ii Pulsed Current Table iii. below shows the time taken to fully discharge the battery pack when continuously applying a three second Bipolar forward ON current and a three second reverse ON current across a 1.0 Ω resistive load. Table iii Bipolar ON + Discharge Time 1 A 2 hours 2 A 1 hours 3 A 0.5 hour Discharge Time 1 A 3 hours Discharge Time 1 A 3 hours Field tests do not require the ECT-4 to be under constant resistive load such as the discharge tests undertaken here, thus the operator can expect the average field test using the 1 Amp current level setting to last well over 5 hours per battery pack. In operation the battery level can be monitored on the test probe s FSTN LCD display. To prolong battery life an automatic shutdown feature will disconnect the battery pack when its capacity runs low. 3.11. Battery Charge Time The ECT-4 is supplied with a dedicated lithium battery charger for exclusive use with the battery pack provided. An average of four (4) hours is required to fully charge the 14.4 V / 3200 mah battery pack. The dedicated battery charger s LED indicator will display a Red colour when the battery pack is charging and a Green colour when fully charged. Warning, do not use a Lithium charger other than the one supplied with the ECT-4 kit as it may result in damaging the battery pack. 3.12. Battery Pack Protection Specifications The 14.4 V, 3200 mah lithium pack supplied has an in-built protection circuit to prevent the over charging and over discharging of the battery pack. Red Phase Instruments have also designed extra protection circuitry to mitigate the effects of the extreme or accidental misuse of the battery pack. Results of tests performed with the inclusion of the extra protection circuitry is shown here: Short Circuit Test Cut-off and disconnect in 7.5 ms at 31 A Overload Test Cut-off and disconnect in 1.5 s at 18 A Thermal Test Cut-off and disconnect at Temp > 70⁰C or 158⁰F 3.13. Temperature Specification - Base Unit Extensive tests have shown that the critical drive system which is the hottest part of the ECT-4 s circuitry never exceeds 10⁰C or 50⁰F above ambient even when run at a full 3.0 Amps into a load. Operating Temperature range: 10⁰C to 55⁰C or 14⁰F to 131⁰F Storage Temperature range: or Relative Humidity is 95% for between: 10⁰C to 55⁰C or 14⁰F to 131⁰F is 30⁰C to 70⁰C -22⁰F to 158⁰F Please note: for equipment safety, the thermal cut-off temperature for the ECT-4 base unit s operation has been set to 55⁰C or 131⁰F Ambient. 3.14. Thermal Drift Thermal drift test performed across the following temperature range: 20⁰C to 10⁰C or 68⁰F to 14⁰F Resistance drift reading Over 30⁰C / 86⁰F change: 60ppm / ⁰C Current drift reading Over 30⁰C / 86⁰F change: 25ppm / ⁰C 3.15. Fan Operation The latest ECT-4 design saves battery power even further by activating the convection fan only during prolonged high current activity and / or high ambient temperatures. When the base unit s internal current source circuit has cooled sufficiently the convection fan will turn off. 6

4.0. IMCLUDED ACCESSORIES The ECT-4 kit comes with the following included accessories Main Earth Cables 10m / 33 ft twin core cable with 1mm 2 conductors. Part No. ECT-4 10M 100m / 330 ft twin core cable with 1mm 2 conductors. Part No. ECT-4 100M 5.3. Weight ECT-4 Base Unit: ECT-4 Pack: ECT-4 Probe: ECT-4 Batt: ECT-4 Charger: ECT-4 10M: ECT-4 100M: ECT-4 Ref: ECT-4 Holster 2.0 kg or 4.4 lb 0.5 kg or 1.1 lb 0.5 kg or 1.1 lb 0.35 kg or 0.77 lb 0.15 kg or 0.33 lb 0.5 kg or 1.1 lb 4.5 kg or 10 lb 0.20 kg or 0.44 lb 0.20 kg or 0.44 lb Battery Pack and Charger A 14.4 V / 3200 mah Lithium battery pack + cable Part No. ECT-4 Batt Dedicated Lithium Charger Part No. ECT-4 Charger Carry Pack Carry Pack or Back Pack to house base unit. Part No. ECT-4 Pack 6.0. WARRANTY This product and its accessories is covered by a twelve month limited warranty. Carry pack with 10 m / 33 ft main earth Test Probe Kelvin probe with LCD display, control panel and re-tractable stainless steel pins. Part No. ECT-4 Probe Reference Test Block A 1 Ω Kelvin test block used as a field verification tool. Part No. ECT-4 Ref Accessories listed above may also be purchased separately if required. 5.0. ENCLOSURE 5.1. Cases The ECT-4 Base Unit is housed in a plastic ABS case. A customised carry pack is also provided to house the Base Unit and other accessories. The carry back has the following features: Base Unit pouch with mesh ventilation Two Battery Pack pouches Cable guides Strain relief ring for the main earth cable Padded shoulder straps Waist and chest strap / fastener 100 m / 330 ft main earth cable on a choice of cloth or drum reel 5.2. Case Sizes (L x W x H) ECT-4 Base Unit: 24 cm x 16 cm x 12 cm 9.4 in x 96.3 in x 4.7 in Test Probe: Battery Pack: Probe Pins extended Probe Pins retracted: Carry Pack: 17 cm x 4.7 cm x 15 cm 6.7 in x 1.9 in x 5.9 in 10 cm x 3 cm x 10.5 cm 3.9 in x 1.2 in x 4.1 in 2.2 cm or 0.87 in 0.9 cm or 0.35 in 50 cm x 15 cm x 30 cm 19.7 in x 5.9 in x 10.8 in Every care has been taken to ensure that the above data is correct at the time of printing. Always refer to the latest data sheet when purchasing. RED PHASE INSTRUMENTS reserves the right to alter specifications without notice. 7