install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

Similar documents
Electric Range installation manual

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

For Use with Model(s):all electric models

INSTALLATIONINSTRUCTIONS FREESTANDINGELECTRICRANGE WITH DOUBLEOVENS

Installation Instructions

INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS

INSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES

Installation Instructions

INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES

INSTALLATIONINSTRUCTIONS 30" (76 CM) FREESTANDINGELECTRICRANGES

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

I InstruCtIons. KiitchenAPd I. 30 Electric Freestanding Range IMPORTANT: Read and save these instructions. Part No Rev A

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Pro Island Ventilation Hoods

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Electric standing Range

Installation Instructions Studio Makeup Station

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

I I. Model: DM301 DM302. C a _i'_ 3C 0 I. _M

INSTALLATION MANUAL. Melink Corporation (513) Revision

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

%-_. Quick Reference. TabJe of Contents: Before tou start Product dimensions. Cabinet dimensions requirements Electrical requirements

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

SIDE VIEW. Maximum depth. fa_ro_ab_nne_se top. _25"--_. :ii! iii: i

MASTERsine Inverter PXA Series Installation Guide

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INFORMATION

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Checker Unload Checkstand Installation Instructions

INSTRUCTIONS. Power Panel. Installation Instructions

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

CENTRAL VACUUM SYSTEMS

Company Switch Installation Instructions and User Manual

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Congratulations on your purchase of a Mobile Ramps and Lifts lift.

RoadRelay 4. Installation Guide

Guide to Installing Y o u r H a r m a r S t a i r L i f t

ROSBACK PRINTERS AND BOOKBINDER S MACHINERY Quality Bindery Equipment Since 1881

ROADRELAY 5 Installation Guide

INSTALLATION INSTRUCTIONS

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

Chain/Belt Drive Models PRE-INSTALLATION CONSIDERATIONS

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

SLIDE-IN ELECTRIC RANGE

CorkSport ort Mazda 3 Adjustable Shifter Mazdaspeed 3, Mazda 3 6-speed and Mazda3 SkyActiv 6-speed

PRELIMINARY INSTALLATION INSTRUCTIONS. Remote Engine Starter Attachment Kit P/N 08E92-SNA-100B

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Assembly Instructions

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

INSTALLATION INSTRUCTIONS

Installation Instructions Rotation Control Kit

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DC CCTV Power Supplies Installation Guide

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Guide to Installing Your AMERIGLIDE Stairway Lift

Stevens Type A/F Encoder. For Stand-Alone Encoder Part # AND Encoder Attachment Part # INSTRUCTION 90044

A B C D E F. Tools Required (supplied by others)

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Installation, Maintenance and Service Manual Power Cord

ABOVE-GROUND AUTOMATIC POOL COVER

Installation Instructions

Dry Contact Closure Interface

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Adjustable Light Kits E-Z-Go TXT All Models Installation Instructions

Safe-T-element Installation Instructions

TOYOTA YARIS HATCHBACK INTERIOR LIGHT UPGRADE Preparation

SCION xd INTERIOR LIGHTING UPGRADE Preparation

Service Manual. Model Number: DF2426GB DF2426SS DF2550 DF2562. UL Part Number to 500

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

WARNING. Important Notice

Lokar Cable Operated Sensor Kit Installation Instructions For Ford C4 and C6

Cetra Assembly Instructions

Pretest Module 24 Three-phase Service Entrance

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

ABOVE-GROUND AUTOMATIC POOL COVERS

Installation Instructions Table of Contents

INSTALLATION INSTRUCTIONS

Guide to Installing Your Summit Stairway Lift

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Transcription:

install m ctric Ran Mode_s PB970, PB975 I[_ Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com I BEFORE YOU BEGIN Read these instructions completely and carefully. o IIVIPORTANT - Savethese instructions for local inspector's use. - important - Observe a, governing codes and ordinances. e Note to mnstaller - Be sure to leave these instructions with the Consumer. Note to Consumer - Keep these instructions for future reference. Skill levet- Installation of this appliance requires basic mechanical skilts. Completion time - 1 to 3 hours Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. -&WARNING - This appliance must be properly grounded. ANTI-TIP DEVICE -&WARNING - Toreducetherisk of tipping, the appliance must be secured by properly installed Anti-Tip bracket packed with this appliance. -&WARNING - All ranges can tip Injury to persons could result with range See Installation Instructions (_ Install Anti-Tip bracket packed If you pull the range out and away from the wall for any reason, make sure the Anti-Tip bracket is engaged when the range is pushed back against the wall. FOR YOUR SAFETY: -&WARNING - Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 31-10652 02-07 JR

JnstaJJation instructions PREPARE TO INSTALL THE RANGE FOR YOUR SAFETY: MATERIALS YOU MAY NEED AJJ rough-in and spacing dimensions must be met for safe use of your range. To reduce the risk of burns or fire when reaching over hot surface ejements, cabinet storage space above the cooktop shoujd be avoided. Jf cabinet storage space is to be provided above the cooktop, the risk can be reduced by instajjing a range hood that protrudes at Jeast 5" beyond the front of the cabinets. Cabinets instajjed above a cooktop must be no deeper than 13:' Be sure your appjiance is propedy instajjed and grounded by a quajified technician. Make sure the cabinets and wall coverings around the range can w4thstand the temperatures (up to 200 F) generated by the range. Tin Snips Lag Bolts Anchor Sleeves (For Anti-'13p Bracket Mounted on Concrete Floors Only) @ (UL Approved 40 AMP) 4-Wire Cord OR 3-Wire Cord 4' Long 4' Long PARTS INCLUDED Squeeze Connector (For Conduit Installations Only) TOOLS YOU WiLL NEED Anti-Tip Bracket Kit Drill with 1/8" Bit Safety Glasses 171 REMOVE SHIPPING MATERIALS Adjustable Wrench Tape Measure Remove packaging materials, Failure to remove packaging materials could result in damage to the appliance. Pliers Pencil 1/4" Nut Driver Level Phillips Screwdriver Flat-blade Screwdriver

mnstaliation mnstructions PREPARE THE OPENING See illustrations for all rough-in and spacing dimensions. The range may be placed with 0" clearance (flush) at the back wall and side walls of the cabinet. *'30" Min. L AL Acceptable electrical outlet area. *'15" Min. Mi Orient the electrical L i receptacle so the length _231/2 v is parallel to the floor. "_ *0"_ MINIMUM DIMENSIONS BETWEEN COOKTOP, WALLS AND ABOVE THE COOKTOP: * Make sure the wall covering, countertop, flooring and cabinets around the range can withstand the heat (up to 200 F) generated by the range. NOTE: Use a 4' power cord to prevent interference. Power cords 41/2to 6' long may have to be dressed to allow for proper installation. ** Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, and 15" minimum between countertop and adjacent cabinet bottom. *** Recommended spacing to heat-sensitive surfaces.

mnstaliation mnstructions ELECTRICAL CONNECTIONS ELECTRICAL REQUIREMENTS CAUTION: For personal safety, do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation. This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specified on the rating plate. The rating plate is located on the left hand side of the lower oven front frame. Location of i, model plate rating We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located. Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70- Latest Edition. You can get a copy by writing: National Fire Protection Association Batterymarch Park Quincy, MA 02269 You must use a 3-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If the electrical service provided does not meet the above specifications, have a licensed electrician install an approved outlet. Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device. A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 13A" diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable. Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used. NOTE: If conduit is being used, go to Step 3D and then to Step 6 or 7. On some models, a filter capacitor may be connected between the black and white leads on the junction block. ALL NEW CONSTRUCTIONS, MOBILE HOMES AND INSTALLATIONS WHERE LOCAL CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL, REQUIRE A 4-CONDUCTOR UL-LISTED RANGE CORD. Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range. When installing an electric range in new construction, follow Steps 3 and 5 for 4-wire connection. 4

mnstaliation mnstructions POWER CORD AND STRAIN RELIEF INSTALLATION Remove the terminal block cover (on the back of the range) by removing the screw, using a 1/4" nut driver. Do not discard the screw. For power cord installations only (see the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit. NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover.../ block Screw to remove terminal block cover block cover Remove the knockout ring (13X') located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed. NOTE: You only need to remove the knockout ring for power cord installation. block (appearance may vary) Skip to Step 4 or 5. Power cord Bracket For conduit installations only, purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover. block Knockout in bracket ring Knockout ring removed Squeeze connector Conduit Skip to Step 6 or 7. Bracket

mnstaliation ELECTRICAL CONNECTIONS mnstructions (CONT.) 3-WIRE POWER CORD INSTALLATION 4-WIRE POWER CORD INSTALLATION WARNING: The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. Remove the 3 lower terminal screws from the terminal block. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block. DO NOT remove the ground strap connection. Ground plate block (appearance may vary) Neutral terminal Ground strap WARNING: The neutralwire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate and into the frame of the range. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block. block Ground strap Neutral terminal st rap or Power cord Skip to Step 8 and proceed with the installation. After block Ground screw Neutral terminal Ground plate (grounding to range) Skip to Step 8 and proceed with the installation. 6

mnstaliation mnstructions 3-WIRE CONDUIT INSTALLATION Loosen the 3 lower terminal screws from the terminal block. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires. NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make connection. Connect wires according to this Step 6 or Step 7 depending on number of wires. 4-WIRE CONDUIT INSTALLATION Before Loosen the three lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier), Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.), Do not over-tighten the screws since it could damage the wires, round strap or block bl CkGround After str_ Neutral terminal _-_ if block Wire tips Ground plate (grounding to range) Brack_ Conduit Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. Skip to Step 8 and proceed with the installation. Ground screw Bracket Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. Proceed to Step 8.

JnstaJJation instructions INSTALL THE RANGE REPLACE THE WIRE COVER PREPARE TO LEVEL MODELS Replace the terminal block cover on the range back by replacing the screw removed earlier. Make sure that no wires are pinched between the cover and the range back. Measure the height of your countertop at the rear of the opening (X). X Screw to replace terminal block cover ANTI-TIP DEVICE INSTALLATION An Anti-Tip bracket is supplied with instructions for installation in a variety of locations. The instructions include all necessary information to complete the installation. Read the Safety Instructions and the instructions that fit your situation before beginning installation. Adjust two rear leveling legs so that the rear of the cooktop (Y) is at the same height as the counter (X). Slide unit into place. Bracket... Wall plate enter wood _Lt_'_..._, --- Typical installation of anti-tip bracket attachment to wall -4, WARNING: Range must be secured by Anti-Tip bracket supplied. See instructions to install (supplied with bracket). Unless properly installed, the range could be tipped by stepping or sitting on the door. Injury may result from spilled hot liquids or from the range itself. 8

Installation Instructions LEVEL THE RANGE tnstall the oven shelves in the oven and position the range where it wilt be installed. Check for levelness by placing a spirit levet or ^..._'_l a cup, partially filled with water, on one of the oven shelves. If using a spirit level, take two readings--with the tevel placed diagonally first in one direction and then the other. The front and rear leveling legs can be adjusted from the bottom. L rla nv_ er FINAL INSTALLATION CHECKLIST Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced. Be sure power is in service to the building. Check to be sure that all packing materials and tape have been removed. This will include tape on metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated. Check to make sure that the doors are parallel to each other and that both operate smoothly. If they do not, see the Owner's Manual for proper replacement. Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket is securely installed. Use an open-end or adjustable wrench to adjust the leveling legs until the range is level. OPERATION CHECKLIST Turn on one of the surface units to observe that the element glows within 60 seconds. Turn the unit off when glow is detected. If the glow is not detected within the time limit, recheck the range wiring connections. If change is required, retest again. If no change is required, have building wiring checked for proper connections and voltage. Check to make sure the Clock (on models so equipped) display is energized. If a series of horizontal red lines appear in the display, disconnect power immediately. Recheck the range wiring connections. If change is made to connections, retest again, If no change is required, have building wiring checked for proper connections and voltage. It is recommended that the clock be changed if the red lines appear. Be sure all range controls are in the OFF position before leaving the range.

10

11

12 Printed in the United States