PD-1 POWER DISTRIBUTION UNIT

Similar documents
Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

MicroPod Sub User manual / Bedienungsanleitung / Manual del Usario

DSP led gaming monitor USER MANUAL

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

MPS14 Rack Mount Power Supply

02OWNER S MANUAL 06 TROUBLESHOOTING 08LIMITED WARRANTY

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

Mini Hi-Fi System *MFL * SIMPLE MANUAL

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

PY-11 Voltage & Continuity Tester

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

HILLSTONE DC LOAD BANK

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

SUBMERSIBLE WATER PUMP

PM - Projector Mount System

Operating Manual Hyperion 924IPS. Short-Range DC Bar

Technical Information Manual

28W WORK LAMP Model: CTL28 Part No:

DC CCTV Power Supplies Installation Guide

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Fiber Optic Illuminator. Model 21AC Model 21DC

Model MC4 MEDIA CONTROL by OWI

SMP3CTX Series Power Supply/Charger

OPERATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Measurements are expressed in millimeters.

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

BARNSTEAD THERMOLYNE ROTO MIX TYPE

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

Lumitester PD-20 Control Kit

4070 Subwoofer Owners' Manual

music hall cruise control 2.0 INSTRUCTION MANUAL music hall

XS400 Load Bank. Read all instructions before using the load bank. Contents

Heavy Duty Series (HDS) Installation and user guide

MityFlex Peristaltic Pump

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

LED Twister II. User manual UK Version 1.0

Dispenser & Warmer RIC-1909 RIC-1909EXP

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

JANDS DD-8. Technical Manual. Version 1.0

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Pay For Water System DU 1A046A

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

FD Conveyor for FD 260 Tabber

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

LEAD ACID BATTERY CHARGER

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Battery Charger JCB- SCH20LI.2

6 x 10 Belt Disc Sander

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

TIME-10 Process Control Stopwatch

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Twelve Unit Rapid Charger

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

CANARY AUDIO CA-400. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Operating Instructions. International English. CCS Dust Extractor

January Multi award winning power management systems. Super Titan Instruction Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

OPERATOR S MANUAL Please read all the information in this booklet before using the unit.

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Instruction Manual. Fudge Puppy Display Case

TACH-10 Contact / Non-Contact Tachometer

Electric Hi Lo Screen lift Trolley Mount 8960

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

FC-27W 7 dome housing. Installation Instructions

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Rental Industry Safety Tester Safe Check 5s

ELECTRIC HYDRAULIC GEAR PUMP

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

CLEAR-COM ENCORE PK-7 POWER SUPPLY INSTRUCTION MANUAL

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

HD18F2M1.

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Heavy Duty Series (HDS) Installation and user guide

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

AFTER SALES SUPPORT MODEL NUMBER: 45682

Transcription:

PD-1 POWER DISTRIBUTION UNIT USER MANUAL

PD-1 POWER DISTRIBUTION UNIT CONTENTS Specifications... 2 Important Information... 4-5 Introduction Unpacking Mounting Environment Precautions Operating Instructions... 6-11 Front Panel Rear Panel Wiring Instructions... 15 Specifications Power Supply... AC 3 Phase 380 ~ 415V 50Hz Protection... MCB 1 x 63A / MCB 6 x 32A Power Input Connector... C63 Male Socket (plug provided) Indicators... 6 x Voltage, 6 x Ampere Meters Power Outputs... 1 x C63 Female Socket /6xC32Female Sockets (Plugs provided) 1x13AUKSocket/1xSchuckoSocket Auxilary Outputs... 1 x USB Socket (5V) Accessory... 1 x USB Goose Neck Light on USB Connector Accessory Optional... UC-8U Series Flightcase DimensionsHxWxD(mm)... In carton 410 X 670 X 570 Unit size 356 x 483 x 455 Weight (Kgs)... Net weight 23.4 Gross weight 27.8 AspartofourcontinuousR&Dprogramme reserve the right to change specifications without prior notice E&O.E. 3

USER MANUAL PD-1 POWER DISTRIBUTION UNIT The information contained within this manual does not include all of the details of design, production or variations of the equipment. Nor does it cover every possible situation that may arise during installation, operation or maintenance. If you need particular assistance beyond the scope of this manual please contact our technical staff. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING! RISK OF HAZARDOUS ENERGY! TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE DO NOT EXPOSE TO RAIN OR MOISTURE. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. UNIT MUST BE EARTHED AND CORRECTLY FUSED. The lightning bolt triangle is used to alert the user to the presence of un-insulated dangerous voltage within the unit that may constitute a risk of electric shock. The exclamation mark triangle is used to alert the user to important operating or maintenance instructions in the literature accompanying the product. Features CE Conformity This equipment has been tested and found to conform to the requirements of the EMC Directive 89/336/EEC, the requirements of the Low Voltage Directive 73/23/EEC, amended by 93/68/EEC and to the following standards: EMC Emission EN55103-1 (1996) EMC Immunity EN55103-2 (1996) Electrical Safety EN60065 (1998) 1 x 63 Amp 3 Phase Inlet 1 x 63 Amp 3 Phase Outlet 3 Phase Isolator for the 3 6 x mp Single Phase Outlets 1 x European Shuco Outlet 1 x 13 Amp UK Outlet 1 x USB Socket Individual Voltmeter and Ampmeter for Single Phase Outlets Individual Isolators for Single Phase Outlets Attractive styling Wellington Close Parkgate Knutsford Cheshire WA16 8XL England Tel: +44 (0)1565 654641 Fax: +44 (0)1565 755641 Email: info@ohm.co.uk Website: www.ohm.co.uk 4

PD-1 POWER DISTRIBUTION UNIT Introduction Congratulations on having purchased an OHM PD-1 Power Distribution Unit Please read this manual and familiarise yourself with the operation of your OHM PD-1 Power Distribution Unit before you attempt to power up this unit. For your own safety we recommend you take the time to read all the warnings and precautions on the page opposite and study the connection details to ensure correct usage and avoid any misuse which may invalidate your warranty. Record the model and serial number, found on the back of the unit, in the spaces designated on the warranty card and in the space provided below. Refer to the model and serial number whenever you call upon your dealer for information or service on this product. Model Serial Number Unpacking Carefully open the shipping carton and check for any noticeable damage. Every OHM PD-1 Power Distribution Unit has been rigorously tested and inspected before being carefully packaged, prior to shipping. If any damage has occurred to the packaging or the unit during transit, please notify the delivery company as soon as possible. Only the consignee can file a claim against the carrier for shipping damage. Be sure to save the carton and all packing materials for the carriers inspection. We recommend that you retain the original carton and packing materials for use should you transport or ship the unit in future. Mounting Front and rear mountings are fitted to each unit, which conform to standard 19 rack strip specifications. We recommend that you make use of these mountings and install your PP-1 Power Distribution Unit in a suitable equipment rack, such as a UC-8U Flight case, also available from OHM. Please refer to the specification table (page 2) for the correct height and depth information for your particular model and ensure sufficient rack space is available Precautions Retain this manual for future reference. Do not stand the patch panel vertically on it s rear. Always check that the correctly rated power is supplied to your unit. When connecting external units to this unit ensure that correctly wired connectors are used, refer to the user manual for the external unit for this information. Avoid direct contact of your unit with water or other liquids. Do not operate while standing in liquid. When cleaning the unit wipe with a soft, dry cloth. If more heavy duty cleaning is required disconnect from the mains and use a damp cloth, ensuring that the unit is completely dry before reconnecting to the mains. Do not use solvents or chemicals on the exterior of the unit as they may cause the surface to discolour and peel. Do not use this unit with frayed or broken power cords. If you experience continuous problems, disconnect from the mains and refer to a qualified service engineer. 5

OPERATING INSTRUCTIONS 1 2 3 4 5 6 63A POWER DISTRIBUTION 235 16.4 238 27.3 232 21.9 235 16.4 238 27.3 232 21.9 FRONT PANEL 1 Voltmeter Illuminated display of voltage being drawn by the phase. 2 Trip Switch MCB trip switch 3 Ampmeter Illuminated display of amperage drawn by the phase. 5 Phase Refers to the phase of the two channels, 63 Amp per Phase. 6 Heavy Duty steel case 8 Unit case, including rear support lugs. Designed to fit into the optional OHM 8UC ATA Flight case. 4 Channel Number Refers to the channel, mp per output 6

PD-1 POWER DISTRIBUTION UNIT 2 3 4 5 6 ON USB LIGHT 5V WELLINGTON CLOSE PARKGATE KNUTSFORD CHESHIRE WA16 8XL Tel. +44 (0)1565 654641 e-mail: info@ohm.co.uk www.ohm.co.uk OUTLETS OFF 1 3 PHASE ISOLATOR PHASE ONE BROWN EARTH 63A POWER DISTRIBUTION INPUT 63 A 400V 50~ OUTPUT 63 A 400V 50~ PHASE TWO BLACK PHASE THREE GREY 8 7 REAR PANEL 1 Earth Terminal. Additional Earthing point. 5 USB Socket (5v) USB socket to take USB peripherals such as LED Gooseneck Lights. 2 63 Amp 3 Phase Isolator This will Isolate the power if any phase goes to short circuit. 3 European Shuco Outlet Socket European Standard gated Socket. 4 13 Amp Outlet Socket UK Standard Gated Socket. 6 6 x mp Outlet Sockets Standard mp female socket. 7 63 Amp Outlet Socket Standard 63 Amp female socket. 8 63 Amp Inlet socket Standard 63 Amp male socket. 7

OHM UK HEAD OFFICE OHM (UK) Limited Wellington Close Parkgate Industrial Estate Knutsford Cheshire WA16 8XL England Tel: +44 (0) 1565 654641 Fax: +44 (0) 1565 755641 e-mail: info@ohm.co.uk www.ohm.co.uk OHM ASIA Harness Overseas (P) Limited SCO 381 Sector 37D Chandigarh India Tel: +91 172 2697 465 Fax: +91 172 2688 254 e-mail: lalit_chopra@harnessasia.com www.harnessasia.com OHM EUROPE Danzer & Kamm Gbr Schnieglinger Str. 166 D-90425 Nuremberg Germany Tel: +49 (0) 911 230 85 10 Fax: +49 (0) 911 230 85 33 e-mail: info@ohm-europe.com www.ohm-europe.com OHM POLAND OHM Polska Sp.z.o.o 62-300 Wrzesnia Ul. Wojska Polskiego 13 Poland Tel: +48 603 984 136 Fax: +48 61 640 02 62 e-mail: info@ohm.pl www.ohm.pl OHM CHINA Guangzhou OHM Audio Co., Limited #3-1 Huancun Road Caibian Village, Donghaun Road Shiqiao, Panyu, Guangzhou P.R. China Tel: + 86 20 3451 1231 Fax: + 86 20 8466 2675 e-mail: info@ohmchina.com www.ohmchina.com