Output Interface (OI)/Motor Output Interface (MOI)

Similar documents
1x 20A H Bridge output for controlling direction of DC motors through polarity change (MOI)

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

MGL Avionics EFIS G2 and iefis

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Timer Relays - Fixed & Adjustable

Power Distribution System User s Manual. Model: PDS-100

Timer Relays - Fixed & Adjustable

SB SWITCH CONTROL BOX

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Compact Sine Inverter

PS24/AC Volt AC 16 Amp

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

Model APS-101N Installation Manual

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Vehicle Security System

EPC DC MOTOR SPEED CONTROL

PO Box 2484 Rowville Vic 3178

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

EC400 Power Control System

EMERGENCY VEHICLE BATTERY MANAGER PS2024

24V 3A EN54 Ancillary Power Supply

Timer Relays - Fixed & Adjustable

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Infinitybox Express Road Race Car Kit Installation Guide

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

RF-51-eDp. Operation guide. Deluxe 2-way Oem Upgrade & Range extender. July 22, 2014

GLM SERIES CONTROL Users Manual Rev:

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Model PRO 9246CH Installation Manual

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

IVTM Installation Manual

Bringing Component Parts Together

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Model: AEM14 Analog Engine Monitor

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Low and High Voltage Power Supplies

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation Guide Rollerdor RD55 Econ Roller Garage Door

Emergency lighting units EM powerled

Safety technique. Emergency Stop Module BH 5928, BI 5928

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

Installation Instructions

Tires are available in a number of sizes and tread patterns dependent on the vehicle usage. Tire sizes are as follows:

Model APS-25CH Installation Manual

Vehicle Security System

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Welcome to PTI--Photon Technology International--Optical Building Blocks!

Emergency lighting units EM INVERTER

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

DR8010 tm. Hardware Reference Manual. Document Revision B4 May 15, 2018

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Congratulations on your purchase of your new Ultra-SoniTec Antifouling System! Ultra-SoniTec Antifouling System! Ultra-SoniTec Advanced Ultrasonic

Model APS-25N Installation Manual

IES GRID FEED-IN LIMITER

The sun as power station

3 Uninterruptible Power Systems

Features include : - 2 Auxiliary Channel Output - Silent Arm/Disarm. - 2-Stage Disarm. - 2 Remote Transmitters

CA 421 Installation Instructions

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Emergency lighting units EM series

Setup and Configuration Guide Universal Switch Interface

PLATINUM Series CAN WIDEBAND CONTROLLER WBC 1 & WBC 2 QUICK START GUIDE (HT & HT059980) Version 4

Master DIALOG INDUSTRY RANGE

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

INSTALLATION INSTRUCTIONS. Revision 4.0.3

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

EcoSystem Multiple Control Input Ballasts

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

CTi Automation - Phone: Fax: Web:

MERU Solar Off-Grid Inverters

Solid-State Compass with GPS Receiver

Power Converters. Output Current Function Design Features

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

AXA DALI P20. DALI Broadcast Controller. Installation Manual

AUTO PUMP STATUS CENTER

LED Driver Compact fixed output

LED Driver Compact fixed output

Vehicle Security System

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

J3C-H Nm Smart Electric Valve Actuator

Softstarter Intelligent Controllers

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

INSTALLATION INSTRUCTIONS

Adaptive Power Module

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Model FHL-CHG Headlight Flasher (Isolation Model) for Positive-Side Switched Headlights

FCA2016-U1 RS485 class A module (isolated) Mounting Installation

Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable

Transcription:

Output Interface (OI)/Motor Output Interface (MOI) Product descriptions: Output Interface (OI): The Output Interface module is where the circuit control and protection takes place, these modules have been designed to be mounted in many locations around the vessel to bring the circuit control and protection closer to the load Motor Output Interface (MOI) The Motor Output Interface is designed for loads such as trim tabs and hatch lifters where a polarity reversal is required to change the direction of the motor, it also has two standard output channels OI/MOI Features: 6x 20A circuits per module (OI) 2x 20A Circuits per module (MOI) 1x 20A H Bridge output for controlling direction of DC motors through polarity change (MOI) Each circuit channel is programmable to offer circuit protection with settable break currents ranging from 200mA to 20Amps Multiple channels can be bridged together to offer higher current switching Selectable fusing characteristics to cater for various load types ie Slow and fast blow, characteristics found in traditional mechanical fuses and circuit breakers LED indication for individual circuit and network status (see LED Flash codes below) Robust, reliable electronic design - Each FET is rated to 75A -Isolated ground giving electronics protection from ground loops Manual Systems override, In case of mechanical failure to network a mechanical override is provided on the OI for each circuit in the form of an ATC fuse. Remove the fuse and place into the bypass position to bypass the OI control 4 levels of fusing - Mechanical fuse - Hardware short circuit protection - Software short circuit protection - Software over current protection IPX5 water ingress and Ignition protection Power consumption: @12V: 85mA (standby 60mA) Weights: OI = 659g MOI = 609g Pulse width modulation (Current Control) Dimming control of lighting circuits Smooth start effect for turning lighting on gradually Soft start for prolonging the life of halogen bulbs through limiting the shock on the fi lament by high in rush currents found during normal cold switch on. Can also be used to reduce large inrush currents on motors. Timer functionality Plug and play confi guration Inputs Network, NMEA 2000 5 35V DC EMC ratings: IEC EN 60945 IEC EN 61000 FCC Class B ISO 7637-1 (12V Passenger cars and light commercial vehicles with nominal 12 V supply voltage - Electrical transient conduction along supply lines only) ISO 7637-2 (24V Commercial vehicles with nominal 24 V supply voltage - Electrical transient conduction along supply lines only) IEC Standards for indirect lighting strikes Dimensions: H 128mm (5 ) x W200mm (7 29/32) x D 45mm (1 3/4)

LED Flash Codes Power available Indicator Channel status indicators Network Status indicator Power available Indicator MOI only Extinguished = No input power connected Green = Input power available Red = Input power reverse polarity Channel Status Indicators Network Status Indicator Extinguished = Network power disconnected Green = Network power connected Red = Network traffi c

Connections Electrical Connections OI: Electrical Connections MOI:

Labelling Connections label This label is located between the output connection and the bypass fuses, it gives the fi eld user or installer an indication of the connections without the need to refer to a manual OI LED flash code label This label is located on the inside of the front lid of the unit, it shows the LED codes and an instruction on how to manually bypass the circuits MOI Circuit Identification labels Standard BEP circuit breaker panel labels are used to indicate the circuit name for each output OI Module Identification and Dipswitch label MOI These labels allow easy identifi cation of each module whilst recording the dipswitch setting. These labels are to be fi tted to the cover and to the module (this prevents covers being swapped). To record the module type and dipswitch settings use a permanent marker and strike through the applicable boxes (a strike through on a dipswitch box indicates that switch is on).

Installation Guidelines Ensure the modules are installed vertically with the cables exiting downwards All seals and cable glands must be fi tted including blanking plugs inserted in any unused positions. Any DC cables carrying 100Amps or more must be mounted 50mm or more from any OI or MOI Ensure all labels are fi tted and correct

Pictorial Overview OI with cover removed Circuit status indicator Fuses for By-pass DC Positive feed NMEA 2000 connector OI with cover Fitted Circuit ID label Waterproof cover DC outputs (to loads) Protective boot

Dimensions

Dimensions