Technical Section: Miniature Circuit Breakers

Similar documents
DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Paramount HRC Cartridge

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Miniature & Moulded Case

XT IEC Power Control Manual Motor Protectors

ADS7 AC Contactor Starters

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Starting of Induction Motors

Low Voltage Fuses For Motor Protection

ACW Molded-Case Circuit Breaker UL 489 Listed

Short-circuit current limiter S800-SCL-SR

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Motor Starting Solutions Open Type Version, in Kit Form

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

DPX moulded case circuit breakers

Terasaki (Europe) Ltd

Phase + Neutral, neutral on left side

Leadership in Circuit Protection

Leadership in Circuit Protection

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Global Range Standard MCCB Fixed 3P (Thermal-Magnetic) No. of Interphase Barriers

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

General data 5/37. Overview

NEW SERIES OF ETIBREAK EB2 IN VIEW OF SELECTIVITY

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Intelligent Choice for Prestigious Buildings

Miniature Circuit-Breakers (MCBs)

Phase + Neutral, neutral on right side

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Bussmann series NH catalogue. Leadership in circuit protection

3RT14 Contactors with 3 Main Contacts

UPDATED APRIL Motor Protection Concepts and Type 2 Co-ordination Charts

Starting Combinations

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low Voltage A GE Power Controls Company. General catalogue

DX³ 4-pole RCBO 6000 A/10 ka

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Selective Coordination

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Bulletin 1489 Circuit Breakers. Selection Guide

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

MoDPlus Din Distribution Boards

Control Circuit Protection

Motor Protection Circuit Breakers 3VU13 and 3VU16

Technical Information

ABB Softstarter Benefits Charnchanok Thongprad

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Selective main circuit breakers S 750 series Technical Data

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

ICG Switchgear Price List 2009

QF(13) - Series Miniature Circuit Breakers

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

QF(19) - Series Miniature Circuit Breakers

GLOBAL RANGE. Global Range Motor Control. Contactors. Features. Applications. Overload Relays. Features. Applications. Manual Motor Starter Features

Installation Manual for DC Injection Brake Units

RVS-AX Instruction Manual

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

Protection Equipment

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Devices for Branch Circuits and Feeders

Cascading & Discrimination

UMBW-UL489 and UL1077 Listed

Components for EEx e Panels

Short form catalogue. Motor protection & control

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

1492-CB 1492-GH 1492-GS

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

MAGNETIC MOTOR STARTERS

CI-TI Contactors and motor starters Types CI 61 - CI 98

Synergy EN product information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Bulletin 825 SMM Smart Motor Manager

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactors and Overloads MC

DX³ RCBO 6000A Phase + Neutral, neutral on left

Technical Information

L Frame - Series Moulded Case Circuit Breakers

Technical Information

An electrical panel capable of evolving

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DX³ RCBO 6000 A Phase + Neutral, neutral right side

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Btdin RCBO 6000A up to 63A (2P)

Manual motor starters Overview and benefits

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

AF series contactors (9 2650)

Motor-protective circuit-breakers PKZ: now better than ever

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

max pole for t=15 ms

Transcription:

MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products Products comply to local and international standards (SANS, VC, IEC, etc).. DC Voltage Rating Please refer to CBI catalogues / leaflets for DC ratings. 4. For reverse connection Contact CBI for details. 5. Module Width CBI s MCB module widths are: mm and 26 mm dual mounting - (Escutcheon height 57 mm). mm, 8 mm and 27 mm in din-rail mounting (Escutcheon height 45 mm), Suffix D. 6. Special Breakers For all breakers manufactured to non-standard requirements, prices will be by quotation only 7. Standard Current Ratings Ampere ratings as indicated are standard. Non-standard ratings can be provided Prices on request (POR). 8. Switch Disconnectors All switch disconnectors must be backed up by a suitable short circuit protection device (SCPD), having the same or lower current rating and the same interrupting capacity as the switch disconnector, unless otherwise stated. Contact CBI for availability of 4 Pole switch disconnector units. 9. Motor Starting Please refer to Page 95 or CBI catalogue. Technical Section: Miniature Circuit Breakers 0. Time Delay Curves Curve No. Time Delay Instantaneous (short circuit) Non Tripping Current Tripping Current Long High 0 20 x In.05 x In.0 x In 2 Medium Medium 5 0 x In.05 x In.0 x In Short Low 5 x In.05 x In.0 x In 2, (LL) Medium 5 % Trip Point (Load Limiting).05 x In.5 x In 9 Long Medium 7 2 x In.05 x In.0 x In B Short Low 5 x In. x In.45 x In C Medium Medium 5 0 x In. x In.45 x In D Long High 0 20 x In. x In.45 x In OP (AC+DC) Very Short Low 5 x In.05 x In.0 x In U2 (DC) Medium Medium 6 x In.05 x In.0 x In KM Medium Medium 6 2 x In.00 x In. x In Note: Other curves available on request. Page 92

MCCBs and Accessories Data. 000 V Rating For 000 V rating, please consult CBI. (Switch disconnectors not available) 2. Adjustable Current Ratings Technical Section: Moulded Case Circuit Breakers From the FD range upwards, some breakers are fitted with adjustable magnetic trips. The suffix V/E types also have adjustable overload trips. E (electronic) types down to 50 % of nominal rating and suffix V (mechanical) types down to 75 % of nominal rating.. Calibration CBI thermal breakers are calibrated at 40 C, unless otherwise stated. Derating for higher temperature environment to be done in accordance with derating curves. 4. Reverse Connection Contact CBI for details. Units indicated line / load should not be reverse connected. 5. Special Breakers Prices for all breakers made by CBI to meet non-standard rating requirements of customer will be by quotation only. 6. Standard Current Ratings Ampere ratings indicated are standard. Non-standard can be provided, on application at a surcharge of up to 20 % of the next standard rating price, depending on quantity, product type and acceptance by CBI. 7. Switch Disconnector Fault Ratings The fault current ratings of CBI switch disconnectors which are fitted with shunt trips and external tripping devices are the same as those of the corresponding circuit breakers. Additional of interface barriers is mandatory. 8. Terminations Consult CBI Catalogues for details. 9. Transient Inrush and Close Co-ordination Protection Higher transient motor starting current associated with some high efficiency motors have created nuisance tripping problems. Consult CBI when in doubt. 0. DC Interrrupting Capacity Refer to CBI DC Catalogue for details.. Motor Starting In addition to cable protection functions, the CBI circuit breakers are designed for induction motor starting and protection duties. These breakers are particularly suited to direct-on-line starting applications for standard type motors in conjunction with a contactor overload combination or as a stand-alone unit. For complete details, refer to the Motor Starting and Protection Application Guide and Circuit breaker Selection Guide for DOL Motor Starting.. Warranty Claims Products may only be returned to CBI for warranty claims if all conditions under Section 7, Limitation of Liability, of CBI s General Terms and Conditions of Sale have been met (copy available upon request). Page 9

MCB Dimensions MCB Dimensions Product Height (A) Width (B) Depth (C) Escutcheon (D) QA - () 9 66 57 QA - 2() 9 26 66 57 QA - () 9 9 66 57 - () 9 66 57-2() 9 26 66 57 - () 9 9 66 57-4() 9 52 66 57 - (26) 9 26 66 57-2(26) 9 52 66 57 - (26) 9 78 66 57-4(26) 9 04 66 57 - (27)-D 97,5 27 65 45-2(27)-D 97,5 54 65 45 - (27)-D 97,5 8 65 45-4(27)-D 97,5 08 65 45 - (27)-D 97,5 27 65 45-2(27)-D 97,5 54 65 45 - (27)-D 97,5 8 65 45-4(27)-D 97,5 08 65 45 4 A/C - D 9 6 65 45 QA7 A/C 9 26 64,8 57 7 A/C 9 26 64,8 57 SM5A 22 65 66 57 SM6A 22 7 66 57 Note: All measurements are in mm. Technical Section: MCB Dimensions Page 94

Technical Section: Motor Starting Guide: 20-400 V MOTOR SIZE (kw) 0.2 0.8 0. 0.7 0.55 0.75..5.8 2.2.7 4 4.5 5.2 5.5 6 7 7.5 9. 5 8.5 22 26 0 7 45 55 75 90 0 2 60 200 0 5 55 400 450 500 560 60 70 Notes: SINGLE PHASE VOLTAGE THREE PHASE VOLTAGE 20 V AC 400 V AC 5 ka 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* A* 0 A* 0 A* 5 A* 40 A* 45 A* 50 A* 60 A* 70 A* 80 A* 00 A* 0 ka 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* A* 0 A* 0 A* 5 A* 40 A* 45 A* 50 A* 60 A* 70 A* 80 A* 00 A* 5 ka A* 2 A* 2 A* 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* 20 A* 20 A* 20 A* A* 0 A* 5 A* 45 A* 60 A* 70 A* 80 A* 00 A* 0 ka A* 2 A* 2 A* 5 A* 5 A* 5 A* 5 A* 0 A* 0 A* 0 A* 5 A* 5 A* 20 A* 20 A* 20 A* 20 A* 20 A* A* 0 A* 5 A* 45 A* 60 A* 70 A* 80 A* 00 A* 5 ka G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 2 A G5D 2 A G5D(40 A G5D 40 A G5D 50 A G5D 6 A G5D 80 A G5D 00 A G5D 00 A G5D A G5D A F5D 75 A F5D 2 A F5D 0 A / FD 0 A KD 50 A KD 400 A K5D 500 A K5D 600 A L5DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM (750 A) ACB2000CM(900) ka 5 ka Note: * = External Overload Protection Required. ** = Locked Rotor Protection Only. GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 6 A** GD 20 A GD 20 A GD 20 A GD 20 A GD 2 A GD 2 A GD 40 A GD 40 A GD 50 A GD 6 A GD 80 A GD 00 A GD 00 A GD A GD A FD 75 A FD 2 A FD 0 A / FD 0 A KD 50 A KD 400 A K5D 500 A K5D 600 A L5DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM(750A) ACB2000CM (900 A) G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 6 A** G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 20 A G5D 40 A G5D 40 A G5D 50 A G5D 6 A G5D 80 A G5D 00 A G5D 00 A G5D A G5D A F5D 75 A FD 2 A F5D 0 A / F5D0 A K5D 50 A K5D 400 A K5D 500 A K5D 600 A L5DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM(750 A) ACB2000CM(900 A) ) All information in this table is for reference and selection purposes only, and only direct line (DOL) starting. 2) Breaker selection is based on 4-pole three phase squirrel cage motors and certain deviations may be encountered for different motor manufacturers. ) Circuit breaker settings are based on rated motor current multiplied by,6 to prevent starting current from exceeding the instantaneous pick-up current of the circuit breaker. 4) For complete details refer to the Circuit Breaker Selection Guide for DOL Motor Starting. These are adjustable breakers and the current in ( ) is the ampere value that these breakers must be set at. 65 ka Curve Circuit Breakers Only. F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (6 A)** F65DV 6- (20 A) F65DV 6- (20 A) F65DV 6- (20 A) F65DV 6- (20 A) F65DV -40 (2 A) F65DV -40 (2 A) F65DV -40 (40 A) F65DV -40 (40 A) F65DV 40-6 (50 A) F65DV 40-6 (6 A) F65DV 80-/6-00 (80 A) F65DV 80-/6-00 (00 A) F65DV 80-/6-00 (00 A) F65DV 80- ( A) F65DV 80- ( A) F65DV 60-0 (75 A) F65DV 60-0 (2 A) F65DV 0 A / K65DE 0 A) K65D 200-400 (50 A) K65D 200-400 (400 A) K70D 00-60 (500 A) K70D00-60 (600 A) L70DE 800 (700 A) N85DE 000 (900 A) N85DE 000 (000 A) N85DE 0 (200 A) N85DE 0 (0 A) N85DE 600 (400 A) N85DE 600 (600 A) ACB2000CM(750 A) ACB2000CM (900 A) Page 95

DOL: Contactor - Overload - MCCB Selection Note: Customer to confirm motor FLC on site and adapt where necessary Motor Rating 400 V FLC Contactor Rating OL Relay Setting MCCB Rating Cable PH Kw HP AC A Type MCM AC A Type OR Range A A Size mm 2 5,5 7,5, CC8 8 CMT2 9 to A G7D 20 2,5 7,5 0 5,2 CC8 8 CMT2 2 to 8 A G7D 40 2,5 5 2,7 CC40 40 CMT2 8 to A G7D 40 4 5 20 29, CC40 40 CMT2 22 to 2 A G7D 50 0 8,5 6 CC40 40 CMT2 28 to 40 A G7D 6 0 22 0 4 CC50 50 CMT6 4 to 50 A G7D 00 0 0 40 55 CC65 65 CMT6 45 to 65 A G7D 00 6 7 50 68 CC85 85 CMT95 54 to 75 A 45 60 8 CC85 85 CMT95 70 to 95 A 5 55 75 99 CC00 00 CMT95 80 to 00 A 75 5 75 00 4 CC50 50 CMT50 0 to 50 A K50D 2 50 90 6 CC85 85 CMT2 20 to 85 A K50D 0 95 0 50 96 CC2 2 CMT2 60 to 240 A K50D 50 95 2 80 2 CC2 2 CMT400 200 to 0 A L65D 400 50 60 220 279 CC0 0 CMT400 260 to 400 A L65D 500 85 200 270 49 CC400 400 CMT400 260 to 400 A L65D 600 240 0 40 47 CC60 60 CMT800 400 to 600 A L65D 700 00 Motor Rating 500 V FLC Contactor Rating OL Relay Setting MCCB Rating Cable PH Kw HP AC A Type MCM AC A Type OR Range A A Size mm 2 5,5 7,5 9 CC8 CMT2 7 to 0 A G7D 6,5 7,5 0 2, CC8 CMT2 9 to A G7D 20 2,5 5 7,4 CC40 2 CMT2 6 to 22 A G7D 40 2,5 5 20 2,4 CC40 2 CMT2 8 to A G7D 40 6 8,5 28,9 CC40 2 CMT2 24 to6 A G7D 50 6 22 0 CC50 4 CMT6 24 to 6 A G7D 50 0 0 40 44 CC65 60 CMT6 4 to50 A G7D 00 0 7 50 54 CC85 75 CMT95 45 to 65 A G7D 00 6 45 60 65 CC85 75 CMT95 54 to 75 A G7D 55 75 79 CC00 85 CMT50 6 to 85 A G7D 5 75 00 07 CC50 00 CMT2 85 to A 75 50 90 29 CC85 85 CMT2 20 to 85 A 200 50 0 50 57 CC85 80 CMT50 20 to85 A K50D 0 95 2 80 84 CC2 200 CMT400 60 to 240 A K50D 00 95 60 220 224 CC0 280 CMT400 200 to0 A K50D 50 50 200 270 279 CC400 50 CMT400 260 to 400 A K50D 400 85 0 40 49 CC60 500 CMT800 400 to 600 A L65D 60 240 Technical Section: Motor Starting Page 96

Note: Customer to confirm motor FLC on site and adapt where necessary Technical Section: Motor Starting Page 97

DOL Starting (Full Load) R S T MCCB MCM TOR FUSE PB-OFF PB-ON TOR MCM M Conditions. The load shall be an Induction Motor with phase and 4 Poles. 2. Overload relay setting range is selected according to the full load current of the motor.. Cross-section area of the cable is within the value that is connectable to the motor starter. 4. Circuit Breaker (MCCB) is for cable protection. The breaking capacity of the MCCB should be reviewed according to site conditions. R S T Star Delta Starting MCCB FUSE PB-OFF MCM TOR X PB-ON MCM : TOR TR U V W M MCD MCD MCY X Y Z MCM MCY MCD TR MCY Technical Section: Motor Starting Conditions. The load shall be a squirrel cage motor with phase and 4 Poles. 2. Overload relay setting range is selected according to the full load current of the motor.. When the Thermal Overload Relay (TOR) is placed in the area shown. the setting range should be divided by (0,58) 4 Cross-section area of the cable is within the value that is connectable to the motor starter. 5. Thermal Circuit Breaker (MCCB) is for cable protection. The breaking capacity of the MCCB should be reviewed according to site conditions. 6. Thermal Overload Relay (TOR) mounting.* - Separately mountable with an optional mounting unit - Directly mountable when placed in the area shown in the dotted line Note: * Contact CBI for availability Page 98

Terminations G G4B X Technical Section: Moulded Case Circuit Breakers G4B G4 JSO / JS L20B / L40B N50D / N70D X G4B G4B KD / K5D JS/FD K50D X X2 Notes: Refer to product specific pages for actual terminal types - It might not be available as separate items if supplied as standard. For relevant current carrying capacities, please refer to relevant products. MCCB Terminal Bolt Sizes: JS - M8 L20 / L40B - M2 G5 / D - M8 G5D - M8 F5 / D - M8 F5D - M8 K / 5D - M2 L5 / 50D - M2 MB - M2 N85D - M2 MCCB Standard Range G7D - M8 - M8 K50D - M0 L65D - M2 N65D - M2 Page 99 MCCB Advanced Range G50D - M8 F50D - M8 F85D - M8 F50D - M8 K65D - M0 K85D - M0 K50D - M0 L65D - M2 L00D - M2 N50D - M0 x 2 N70D - M0 x 2 N50D - M0 x 2

THIS IS A SERIES CONNECTED (CASCADING) SYSTEM REPLACEMENT OF THE CIRCUIT BREAKERS OTHER THAN THOSE OF IDENTICAL TYPES SHOULD BE REFERRED TO THE CIRCUIT BREAKER MANUFACTURER Cascading Tables Note: Any current limiting by the cables should be taken into account. The Cascading Table is applied in practice as follows:. Determine the maximum prospective short circuit fault current level at the point of installation of the upstream breaker in the cascade. 2. Moving from the left side towards the right side of the cascading table, in the top row, select an upstream breaker whose breaking capacity rating is equal to or greater than determined by (.) above.. Determine the prospective short circuit current at the installation point of the downstream breaker, taking into account only the current limiting effect of any cable that is connected between the upstream and downstream breakers. Any current limiting by the upstream breaker should be ignored for this purpose. 4. From the first column on the left of the cascading table, select the row that represents a short circuit current that is equal to or higher than this latter short circuit current. 5. The downstream breaker suitable for the cascading application will then be found at the intersection of the row from (2) above, and the column from (4) above. Due to constant research and development, CBI reserves the right to make changes, modifications and extensions to these cascading tables without prior notice. No substitute of any alternative products is allowed. Technical Section: Cascading Care must be taken in replacing older product versions or obsolete ranges. Page 00

low voltage Cascading Table No. Technical Section: Cascading Tables Cascading Table (CBI MCCB s) Type G7D 5 - A 50-0 A K50D 0-400 A L65D 500-800 A No of Poles Fault Level ka 5 5 5 5 5 5 50 5 50 65 Downstream ka 65 50 5 / / 0 / / 20 5,,, / / 0 / BUSBAR RATING ka RMS 20 5 0 Global Range Based Page 0

Cascading Table No. 2 80/45V Specific let-through energy curves 8 0 N50DEV600 5 Technical Section: Cascading Tables Protective Co-ordination Cascading 80/45 System Voltage Main: Advanced MCCB range Branch: Global Standard & Advanced Range G50D F50DEV F50D F50DEV F85DV K65DEV L65DEV L00DV K50D K50DEV N70DEV Capacity (ka rms) 50 50 50 50 85 65 65 00 50 50 70 Main breaker Rated breaking Branch Breaker G7D 7 65 50 70 50 65 50 85 85 7 70 50 K50D 50 85 85 85 70 L65D 65 65 00 F50DEV 50 50 85 65 65 00 50 50 70 F85DV 85 50 00 50 50 K50DEV 65 00 70 L65DEV 65 00 50 70 L00DV 00 L50DEV 50 N50DEV 50 N50DEV 50 70 N70DEV 70 Maximum Let-through l²t (A²s) 2 0 7 5 2 0 6 5 N50DEV000 L50D K50D F50D G50D 2 0 5 5 2 2 4 6 0 20 0 40 60 00 200 Available Short Circuit Current (karms) Page 0

Cascading Table No. 2 K65D 65 400 K5D 5 400 KD 0 400 20 CASCADING TABLE (CBI MCCBs and MCBs) UPSTREAM CIRCUIT BREAKERS 0 0 0 00 TYPE No. OF POLES FAULT LEVEL ka AMP RATING BUSBAR RATING ka RMS G5D / F5D F65DV 5 65 GD / FD G5D / F5D 5 65 50 5 L65D 65 60 G5D / F5D G5D / F5D 5 0 G5D / F5D 0 G5D / F5D G5D / F5D G5D / F5D G5D / F5D G5D / F5D G5D / F5D G5D / F5D PROSPECTIVE DOWNSTREAM FAULT LEVEL ka (RMS) G5D / F5D G5D / F5D G5D / F5D G5D / F5D 20 5 0 TYPE MOUNTING TYPE ESCUTCHEON, mm NOTES: 57 Mini / DIN / = -(), -(8), -(26) 45 DIN = -(8), -(26) ONLY, = Single pole circuit break ers,, = Single, double or triple pole circuit break ers F5D CAN CASCADE WITH ANY FD UPSTREAM BREAKER UP TO THE MAXIMUM FAULT LEVEL ka OF THE UPSTREAM BREAKER Technical Section: Cascading Tables Page 02