Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Similar documents
Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switch - Prewired Type Metal Body

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

FOOT SWITCHES

Safety Limit Switches

LK Position Switches TECHNICAL DATASHEET.

AF40... AF96 3-pole contactors Technical data

Gross Automation (877)

Position switches FR series

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

PRODUCT SPECIFICATION. Foot Switches. Series.

Safety Limit Switch

SFS-UFS Single Foot Switches

FL series position switches

Safety switches for hinged doors

Position switches FD series

Switches with manual reset

Position switches FR series

Comepi Limit Switches

Safety switches with separate actuator

Safety switches for hinged doors

Single foot switches PX and PA series

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Miniaturized limit switches

Safety rope switches with reset for emergency stop

Compact plastic limit switches with positive opening mechanism

Microswitches M series

Position switches FC series

LR-LX-LK-LW Safety Switches with separate actuator

FOOT SWITCHES IN THERMOPLASTIC MATERIAL AND ALUMINIUM DIE CAST PS... / PD... SERIES. Symbols P S / P. Dimensions (in mm)

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Single foot switches PX and PA series

Compact plastic limit switches with positive opening mechanism

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Safety rope switch with reset for emergency stop

Manual Reset Limit Switch

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

ASL09..S 3-pole Contactors - Spring Terminals

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Safety switches with separate actuator

Microswitches MK series

Hinged Safety Door Switch

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

K50H004UP cam changeover switch - 4-pole A - screw mounting

Safety switches for hinges

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Prewired position switches FF series

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

YFC. Limit switch. Ex d. 24 operating head types

Limit Switches Metal casing, 40mm & 60mm Assembled Components

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Microswitches MK series

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Limit switches 3. Page 92. Page 92

XACA871 pendant control station XAC-A - 8 pushbuttons

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Safety rope switch without reset for simple stop

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

Safety-door Switch. Ordering Information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Prewired position switches FF series

Microswitches MK Series

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Limit Switches with Positive Opening Mechanism

Pre wired limit switches

Safety Limit Switch

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

General_technical_data Series

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Description. Positive safety relays

Single foot switches - PX and PA series

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

TAE pole Contactors

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

LJASeries. Limit Switches with Positive Opening Mechanism

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

Transcription:

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66 (metal) Reinforced UL-V0 thermoplastic fiber-glass body Zinc alloy (Zamack) body Positive Opening Operation Minimum Actuation Force/Torque Minimum Force to achieve Positive Opening Operation Precise operating points (consistency) Immune to electromagnetic disturbances Zb type contact blocks Current Ith = 10A Rated insulation voltage Ui = 500V UL, CSA, CE Conform with IEC 947-5-1 (EN 60947-5-1) Product Description They are developed in order to be used for following operations: Ideal for detection and monitoring of faults in hoisting machines, electric lifts, freight elevators, escalators, conveyor belts, etc. With manual reset comply with the requirements of standard EN 418 (safety of machinery - emergency stop). After actuating the control device and overshooting the latching point, the N.C. safety contact(s) remain in the open position. Return to the initial operating state takes place by voluntary action on the pull button reset. To detect or to monitor if a moving part is exceding its allowed travelling path, and stop the equipment in case of malfunctioning. Description of the key codes Cable Gland M P B A N M20 PG13.5 PG11 M16 1/2 NPT Contact block 2NC snap(+) 1NO+1NC snap(+) 2NC slow(+) 1NO+1NC slow(+) Ordering Key Body Cable Gland Contact block Head type Material of body and head Options Head type LR P0 PR R3 R4 RT Options 00 no option PS21K-PRT-M00 Steel PLUNGER with nylon roller Metal plain PLUNGER Metal roller PLUNGER Adj. LEVER with steel ball bearing Plastic roller LEVER on metal PLUNGER (left) Nylon roller LEVER Material of body and head T Thermoplastic body and Thermoplastic head Y Metal body and Thermoplastic head 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208

Technical Data Electrical Data Plastic Body Metal Body Standards IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL508 and CSA C22-2 n 14 Certifications Approvals UL CSA Air temperature near the device - during operation -25 C +70 C/-13 F...+158 F - for storage -30 C +80 C/-22 F...+176 F Climatic withstand According to IEC 68-2-3 and salty mist according to IEC 68-2-11 Mounting positions All positions are authorized Shock withstand (according to IEC 68-2-27 and 60068-2-27) (1/2 sinusoidal shock for 11ms) no change in contact position 50g/1.76oz (1/2 sinusoidal shock for 11ms) no change in contact position Resistance to vibrations (according to IEC 68-2-6 and EN 60068-2-6) 25g/0.88oz (10 500Hz) no change in position of contacts greater than 100µs Protection against electrical shocks (according to IEC 536) Class II Class I Degree of protection (according to IEC 529 and EN 60529) IP65 IP66 Consistency (measured over 1 milion operations) 0.1mm/0.004 (upon closing point) Plastic Body Metal Body Rated insulation voltage U i -according to IEC 60947-1 and EN 60947-1 500V (degree of pollution 3) 400V (degree of pollution 3) -according to UL 508, CSA C22-2 n 14 A 600 Q 600 A 300 Q 300 Rated impulse withstand voltage Uimp (according to IEC 60947-1 and EN 60947-1) 6kV Conventional enclosed thermal current Ithe (according to IEC 60947-1 and EN 60947-5-1) (θ 40 C) 10A Short-circuit protection - gg type fuses 10A Rated operational current Ie / AC-15 - acc.to IEC 60947-5-1 24VAC (50/60 Hz) 10.0A 130VAC (50/60 Hz) 5.5A 230VAC (50/60 Hz) 3.1A 240VAC (50/60 Hz) 3.0A 400VAC (50/60 Hz) 1.8A - acc.to UL 508, CSA C22 n 14 A 600 A 300 Ie / DC-13 - acc.to IEC 60947-5-1 24VDC 2.8A 110VDC 0.6A 250VDC 0.27A - acc.to UL 508, CSA C22 n 14 Q 600 Q 300 Electrical durability (according to IEC 60497-5-1 annex C) Utilization categories AC-15 and DC-13 (see curves and value below) - max. switching frequency Cycles/h 3600 - load factor 0.5 Connecting data of contact blocks Connecting terminals M3.5 (+,-) pozidriv 2 screw with cable clamp Connecting capacity 1 or 2 x mm 2 / AWG 0.5mm 2 / AWG 20 to 2.5mm 2 / AWG 14 Terminal marking According to EN 50013 Positivity Contacts with positive opening operation as per IEC 60947-5-1 chapter 3 Diagram for snap action contact: Millions of operating cycles 5 3 2 1 0.5 0.3 0.2 230-240 400 130 48 12-24 Diagram for slow action contact: Millions of operating cycles 5 3 2 1 0.5 0.3 0.2 230 130 48 12-24 Electrical durability for DC-13 utilization category Power breaking for a durability of 5 million operating cycles Snap action Slow action Voltage 24V 9.5W 12W Voltage 48V 6.8W 9W Voltage 110V 3.6W 6W 0.1 0.2 0.3 0.5 1 2 3 5 10 Current (A) 0.1 1 2 3 5 10 Current (A) Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208 2

Limit Switches - Safety Type (PS21K) Plastic Body IP65 Cable Gland P = one cable inlet PG13.5 cable gland M = one cable inlet M20x1.5 cable gland N = one cable inlet 1/2 NPT cable gland B = one cable inlet PG11 cable gland A = one cable inlet M16x1.5 cable gland Contact block (Zb type) Ø4/ 0.16 4/0.16 22/0.87 20/0.79 30.3/1.19 53/2.09 PG13.5 M20x1.5 1/2"NPT PG11 M20x1.5 24.5/0.96 15/0.59 30/1.18 (1NO+1NC) (2NC) Slow Action (1NO+1NC) Non overlapping Slow action (2NC) Ø8/0.31 35/1.38 88/3.46 Conformity / (NC) EN 50047 / Steel plunger with reset Max. Actuation speed 0.5m/s / 1.64ft/s Code PS21K- P0-T00 9N / 44Nm 97.0g / 3.819oz Ø11/0.43 46/1.81 99/3.90 Conformity / (NC) EN 50047 / Steel plunger with nylon roller with reset Max. Actuation speed 0.3m/s / 0.98ft/s Code PS21K- PR-T00 12N / 41Nm 99.0g / 3.492oz 54/2.13 107/4.21 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS21K- R3-T00 102.0g / 4.016oz 34.5/1.36 29/1.142 54/2.13 107/4.21 5.2/00.21 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS21K- R4-T00 103.0g / 4.055oz 3 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208

53/2.09 35.5/1.40 Ø18/0.71 39/1.54 5.5/ 0.22 40/1.57 15/0.59 17.5/0.69 36/ 1.42 106/4.17 T20 45/1.77 Conformity / (NC) EN 50047 / Lever with nylon roller with reset Max. Actuation speed 1.5m/s / 4.92ft/s Code PS21K- RT-T00 0.10N / 0.32Nm 102.0g / 4.016oz Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208 4

Limit Switches - Safety Type (PS21K) Metal Body IP66 Cable Gland P = one cable inlet PG13.5 cable gland M = one cable inlet M20x1.5 cable gland N = one cable inlet 1/2 NPT cable gland B = one cable inlet PG11 cable gland A = one cable inlet M16x1.5 cable gland Contact block (Zb type) Ø4/ 0.16 4/0.16 22/0.87 20/0.79 30.3/1.19 55/2.16 PG13.5 M20x1.5 1/2"NPT PG11 M20x1.5 14.5/0.57 32.5/1.28 (1NO+1NC) (2NC) Slow Action (1NO+1NC) Non overlapping Slow action (2NC) Ø8/0.31 35/1.38 90/3.54 Conformity / (NC) EN 50047 / Steel plunger with reset Max. Actuation speed 0.5m/s / 1.64ft/s Code PS21K- P0-Y00 9N / 44Nm 193g / 7.598oz Ø11/0.43 46/1.81 101/3.98 Conformity / (NC) EN 50047 / Steel plunger with nylon roller with reset Max. Actuation speed 0.3m/s / 0.98ft/s Code PS21K- PR-Y00 12N / 41Nm 196.0g / 7.716oz 54/2.13 109/4.29 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS21K- R3-Y00 199.0g / 7.835oz 34.5/1.36 29/1.142 54/2.13 109/4.29 5.2/00.21 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS21K- R4-Y00 199.0g / 7.835oz 6 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208

53/2.09 35.5/1.40 Ø18/0.71 39/1.54 5.5/ 0.22 40/1.57 15/0.59 17.5/0.69 36/ 1.42 108/4.25 T20 45/1.77 Conformity / (NC) EN 50047 / Lever with nylon roller with reset Max. Actuation speed 1.5m/s / 4.92ft/s Code PS21K- RT-Y00 0.10N / 0.32Nm 198.0g / 7.795oz Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208 7

Limit Switches - Safety Type (PS42K) Plastic Body IP65 Cable Gland P = one cable inlet PG13.5 cable gland M = one cable inlet M20x1.5 cable gland N = one cable inlet 1/2 NPT cable gland B = one cable inlet PG11 cable gland A = one cable inlet M16x1.5 cable gland Contact block (Zb type) 2 x Pg13.5 2 x Pg11 2 x M16x1.5 2 x M20x1.5 Ø4/0.16 20/0.79 22/0.87 40/1.57 42/1.65 50/1.97 57/2.24 4/0.16 46/1.81 14/0.55 33/1.30 (1NO+1NC) (2NC) Slow Action (1NO+1NC) Non overlapping Slow action (2NC) Ø8/0.31 35/1.38 81 /3.19 Conformity / (NC) EN 50047 / Steel plunger with reset Max. Actuation speed 0.5m/s / 1.64ft/s Code PS42K- P0-T00 9N / 44Nm 126g / 4.961oz Ø11/0.43 46/1.81 92/3.62 Conformity / (NC) EN 50047 / Steel plunger with nylon roller with reset Max. Actuation speed 0.3m/s / 0.98ft/s Code PS42K- PR-T00 12N / 41Nm 128.0g / 5.039oz 54/2.13 100/3.94 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS42K- R3-T00 131.0g / 5.157oz 17...23/ 0.67...0.91 66/2.60 Ø22/0.87 29...35/ 1.14...1.38 34.5/1.69 112/4.41 6/0.24 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS42K- LR-T00 138.0g / 5.433oz 8 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208

53/2.09 26.5/1.04 17.5/0.69 Ø18/0.71 39/1.54 5.5/ 0.22 40/1.57 15/0.59 108/4.25 T20 45/1.77 Conformity / (NC) EN 50047 / Lever with nylon roller with reset Max. Actuation speed 1.5m/s / 4.92ft/s Code PS42K- RT-T00 0.10N / 0.32Nm 129.0g / 5.079oz Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208 9

Limit Switches - Safety Type (PS42K) Metal Body IP65 Cable Gland P = one cable inlet PG13.5 cable gland M = one cable inlet M20x1.5 cable gland N = one cable inlet 1/2 NPT cable gland B = one cable inlet PG11 cable gland A = one cable inlet M16x1.5 cable gland Contact block (Zb type) Ø5.2 0.20 20/0.79 22/0.87 40/1.57 42/1.65 52/2.05 59/2.32 54.5/2.15 2/0.08 12.5/ 0.49 Pg13.5 (x3) 1/2" NPT (x3) Pg11 (x3) M16x1,5 (x3) M20x1,5 (x3) 14/0.55 36/1.42 (1NO+1NC) (2NC) Slow Action (1NO+1NC) Non overlapping Slow action (2NC) Ø8/0.31 35/1.38 98.5/3.88 Conformity / (NC) EN 50047 / Steel plunger with reset Max. Actuation speed 0.5m/s / 1.64ft/s Code PS42K- P0-Y00 9N / 44Nm 295g / 11.614oz Ø11/0.43 46/1.81 100.5/3.96 Conformity / (NC) EN 50047 / Steel plunger with nylon roller with reset Max. Actuation speed 0.3m/s / 0.98ft/s Code PS42K- PR-Y00 12N / 41Nm 298.0g / 11.732oz 34.5/1.36 66/2.60 54/2.13 108.5/4.27 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS42K- R3-Y00 301.0g / 11.850oz 17...23/ 29...35/ 0.67...0.91 1.14...1.38 Ø22/0.87 34.5/1.69 120.5/4.74 6/0.24 Max. Actuation speed 1.0m/s / 3.28ft/s Code PS42K- LR-Y00 307.0g / 12.087oz 10 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208

53/2.09 26.5/1.04 17.5/0.69 Ø18/0.71 39/1.54 5.5/ 0.22 40/1.57 15/0.59 107.5/4.23 T20 45/1.77 Conformity / (NC) EN 50047 / Lever with nylon roller with reset Max. Actuation speed 1.5m/s / 4.92ft/s Code PS42K- RT-Y00 0.10N / 0.32Nm 299.0g / 11.772oz Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208 11

Utilization precautions Plain plunger Correct Incorrect Roller plunger or Roller lever 30 30 Correct 30 Incorrect Incorrect Correct Incorrect Incorrect 5 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208

Utilization precautions Electrical connection and mounting Adjustement Correct Incorrect Incorrect Position adjustement of lever 5 way key actuator head Position adjustement of lever and head Free position adjustement 10 in 10 of lever Example of applications Key actuator type Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 101208 6