OV4 Installation Manual

Similar documents
Introduction... Amplifier Biasing Background Information... Safety... DIVO OV4 General Overview... System Block Diagram and Functions...

How to bias: MTS3200, MTS3212 Rev A 8/1/2008 carvinservice.com

Product Guide: Series III Pump Control Board Set (RoHS)

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Overview of operation modes

Installation Instructions & Users Manual

How to bias: V3M, V3MC Rev A 9/23/2011

TachoReader Combo Plus

CONTROLLER DIAGNOSTIC GUIDE

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

Issue 2.0 December EPAS Midi User Manual EPAS35

MODEL No s: PP3, PP3K

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

EPAS Desktop Pro Software User Manual

Solus Instruction Manual

RATE CONTROLLED TORQUE WRENCH TESTER

GloboFleet. User Manual EAN / GTIN GloboFleet Downloadkey II

(If this step is missed, then OBD software is not going to work. So it's CRUCIAL that you follow below steps).

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

NT-500 Technical Support Guide. For use by qualified company approved Technicians

QUICK INSTALLATION GUIDE

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Auscision 48/830 Class DCC Operating Information

An ISO 9001:2008 Registered Company

How to bias: Vintage 16 Rev C 6/27/2012 carvinservice.com

Li-ion Battery. MLi Ultra 12/2500 MLi Ultra 12/5000 MLi Ultra 24/5000 INSTALLATION AND COMMISSIONING OF MULTIPLE BATTERIES

Nissan Pathfinder (without NAV) (with color screen) HG

Introduction. E-Trac Xchange is versatile and easy to use, so make the most of your E-Trac with this great new feature. Enjoy!

Expansion Signal (XSIG) Card Installation Instructions

Installation Instructions for: Channel Thermocouple Amplifier

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Application Engineering Europe

Throttle Sensitivity Booster

Tail Flick Analgesia Meter Users Manual. Hot Plate Analgesia Meter START STOP HARVARD. Temperature C. Time h.mm.ss HARVARD APPARATUS

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

Chevy Equinox / GMC Terrain 2013-up (with color display) G

User Manual Solar Charge Controller 3KW

SELECT YOUR INSTALL GUIDE

TIRE PRESSURE MONITORING SYSTEM TPMS 2.0

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

MOST-H.U.R. MB/MB-S. Mercedes Head Unit Replacement Interface NTV-KIT421/501. DS, BM 11/10/14 NTV-DOC141 rb8

SE AS - INSTRUCTIONS - Volvo -

January Multi award winning power management systems. Super Titan Instruction Manual

MOST-H.U.R. MB/MB-S. Mercedes Head Unit Replacement Interface NTV-KIT421/501. DS, BM 10/18/18 NTV-DOC141 rb10

ATOTH-G Series BLDC Motor Controller. User s Manual

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Fitting instructions for the Petrol power amplifier

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

SECTION Instrument Cluster and Panel Illumination

GRD502-B Flow Chart 02/05/09

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

G.M. Electronic 4x4 System

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Hi-Z USB Wireless. Introduction/Welcome

TL UNIVERSAL WIRING PROCEDURE

TurfDefender Electronic Leak Detector Kit Reelmaster 5000, 6000 and 5010 Series Traction Units

INSTALLATION INSTRUCTIONS. Revision 3.1.1

SECTION B Supplemental Restraint System

INSTALLATION I N S T R U C T I O N S

Flight Systems. Replacement for KASSEC DESCRIPTION

To get started with RLINK, install the RLINK Smart Device on your bike using this guide.

ENFORCER TM 6201-IQ ELECTRONIC SIREN

Handout Activity: HA061

OWNERS MANUAL POWER PACK 44AH. Part No. COMPBI012. Australia s original Outdoor brand

DSEULTRA DSE6000 Quick Start Guide Document Number

INTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:

SECTION Multifunction Electronic Modules

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

SEAS - INSTRUCTIONS - MERCEDES -

DESCRIPTION & OPERATION

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

AXi-GMBOX1 INSTALLATION MANUAL


SP PRO KACO Managed AC Coupling

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

SECTION 12M - SUPPLEMENTAL RESTRAINT SYSTEM (VERSIONS 8.0 AND 8.1)

Table of Contents. General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options...

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

LN3 Series Motor and Drives

INSTALLATION INSTRUCTIONS

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

B. Ford Fusion 2013-up

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Scout II Operation Instructions

Field Service Bulletin: S3U/Y Console V5 P/N Installation

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

TPMS Adapter Instruction Manual. (Tire Pressure Monitoring System)

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

FOLLOW THE ARROWS. Alspa MV1000 Variable speed drive TEL: INSTALLATION QUICK START PROGRAMMING. FIRMWARE VERSION: 1.

Optional: Wiring a Relay for Gauge Controlled Output

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Throttle Sensitivity Booster

WARNING! USE ONLY IN RACE OR OTHER CLOSED COURSE APPLICATIONS AND NEVER ON PUBLIC ROADS

PHOENIX HV Features of the Phoenix HV-45 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

STP116 STP188. Tyre Pressure Monitoring System. User manual

Transcription:

Orange Amplifiers OMEC House 08 Ripon Way Borehamwood Hertfordshire WD6 JA ENGLAND Tel: +44 0 8905 88 Fax: +44 0 8905 868 Email:info@omec.com OV4 Installation Manual TM Orange USA 065 Peachtree Industrial Ct. Suite 08 Atlanta, GA 3034 USA Tel: -404-303-896 Fax: -404-303-776 Email: info@orangeusa.com

Installation Instructions WARNING : Working on guitar valve amplifiers involves working with POTENTIALLY FATAL HIGH VOLTAGES. INSTALLATIONS MUST BE PERFORMED BY AN APPROVED ORANGE FITTING CENTRE. ALWAYS CONNECT SPEAKERS WHEN APPLYING POWER TO THE AMP. 3 After ensuring that the Confirm the OV4 is Before you start ensure that the amp suitable for installation functions correctly, with no faults. within the chosen Ensure that the bias settings within the amplifier, typically 00w OV4 are correct for the amplifier. The or 50w fixed bias valve factory settings are : 35mA for amps with octal power standard and 35mA for custom. Note : valves, and sufficient The custom setting can be changed by space to mount the OV4. authorised Orange fitting centre. 5 3 OR Mount the OV4 vertically or horizontally on the chassis using Velcro () and if applicable, the mounting bracket (3) To avoid drilling additional holes in the chassis, it may be possible to use existing fixings. An optional screw can be inserted into () to secure the unit if required. During mounting, consideration must be taken to give access to the control buttons and jack inputs. amplifier is TURNED OFF and the valves are cool, remove the back panel of the amp to access the chassis and output valves. 6 7 Plug the valve interceptors () into Connect the black 0v the valve sockets (3) and then plug wire from the the valves () into the interceptors. harness to the true These are marked,,3,4 and 0 volts of the amp. need to be in the correct places to NOTE : In most enable fault diagnosis. The LEDs amplifiers 0v is the on the OV4 unit correspond to the metalwork of the position of the interceptor, i.e. LED chassis, however in is, LED is and so on. Plug some amplifiers 0v is the harness into the OV4 and not directly connected verify that everything is securely to the chassis. connected. Care must be taken to ensure the black zero 0v wire is connected correctly. 3 3 4 4 Find a suitable location within the amp to mount the OV4. Typically this is on top of the chassis at a distance where the wiring harness can easily reach the valves. eg. () Carefully remove the valves from the amp () 8 Connect the case of the OV4 to the amplifier chassis, via the green wire() IMPORTANT : Double-check that the black 0v and green earth wires have good connections and are secure. (Shake proof washers are recommended). When everything is securely connected, the amp can be powered up (standby switch on) The valve LEDs will flash, indicating power to the OV4.After the LEDs stop flashing wait 3 minutes, then the OV4 is operational.

Functional Diagram Mechanical Information Size 60mm X 00mm X 30mm Approx Weight 470g Valve fault indicators. LEDs flash during power up. Individual LEDs illuminate to a corresponding valve failure. For 00W heads all four LEDs are in operation. For 50W heads LEDs &3 are in operation Valves Valve sockets 3 4 Connector interface to the power valve interceptors and amp 0v Earth connection to chassis Interface connection (for authorised personnel) Module configuration and interrogation If the amp is going to be used regularly or driven hard in two valve mode, the speaker should be correctly matched to the amplifier. E.g. if you are using an 8 ohm speaker change to 4 ohms or if you are using a 6 ohm speaker change to 8 ohms. Optional half power footswitch Input (00W amps) LED Footswitch For 00W amps an OV4 compatible footswitch may be used to run the amp at half power. NO LED: ALL VALVES ARE SELECTED SLOW FLASH: VALVES AND 4 ARE SELECTED FAST FLASH: VALVES AND 3 ARE SELECTED PERMENTLY LIT: FAULT INDICATION Amp bias button standard and custom Share the wear button On : Valves alternate between pairs when in half power Off : Valves & 3 are always selected when in half power

Bias Runner Interface The Bias Runner software is compatible with all versions of Microsoft Windows including XP, Vista, and 7. The software requires.net Framework to run which should be already installed within modern Windows systems. If the PC is old and does not have.net Framework it can be downloaded free from http://k79.com/c/netfw35 or from the Microsoft website. To install the software, simply insert the memory stick into the PC, click on the icon and follow the instructions. To interrogate and program DIVO / TubeSync hardware connect the PC and interface as per the diagram below. NEVER CONNECT TO DIVO / TUBESYNC HARDWARE WHEN THE AMP IS POWERED AND ALWAYS DISCONNECT VIA THE SOFTWARE, BEFORE UNPLUGGING THE HARDWARE. USB connection from the PC to the interface module RJ45 connection from the interface module to hardware

Bias Runner Interface Green saved icon appears here to indicate data has been successfully saved to the OV4. Amp serial number cross-reference entry. Access via the pencil icon. Valve bias settings with and without audio Amp service hours Notes field Fault reset When save is pressed the values entered will be saved to the hardware If the hardware detects a valve fault a counter will be incremented. When interrogated the total number of faults are displayed. A reset function can be performed by authorised personnel. Always disconnect before unplugging hardware Displays the history of all entries Under normal circumstances audio threshold, fault times and fault currents should remain at the factory set conditions and should not be modified.