APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Similar documents
Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Brochure. Wind turbine generators Reliable technology for all turbine applications

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL

Chapter 2 Literature Review

Advance Electronic Load Controller for Micro Hydro Power Plant

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

DFIG Wind Turbine Modeling

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Statcom Operation for Wind Power Generator with Improved Transient Stability

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

DUAL BRIDGE RECTIFIER FOR PMSG VARIABLE SPEED WIND ENERGY CONVERSION SYSTEMS

Grid Connected DFIG With Efficient Rotor Power Flow Control Under Sub & Super Synchronous Modes of Operation

Design and Modelling of Induction Generator Wind power Systems by using MATLAB/SIMULINK

Performance Improvement of Low Power Wind-Driven Wound Rotor Induction Generators with Combined Input Voltage and Slip Power Control

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Wind Farm Evaluation and Control

VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS

Implementation of Bidirectional DC-DC converter for Power Management in Hybrid Energy Sources

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Principles of Doubly-Fed Induction Generators (DFIG)

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems

Classification of Wind Power Plants (WPP)

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA

Fault Rid Through Protection of DFIG Based Wind Generation System

Lecture 20: Stator Control - Stator Voltage and Frequency Control

Modelling and Simulation of DFIG with Fault Rid Through Protection

SPEED CONTROL OF THREE PHASE INDUCTION MACHINE USING MATLAB Maheshwari Prasad 1, Himmat singh 2, Hariom Sharma 3 1

Modeling, Simulation & Control of Induction Generators Used in Wind Energy Conversion

Simulation and Analysis of a DFIG Wind Energy Conversion System with Genetic Fuzzy Controller

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

9. Examples of hydro energy conversion

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Synchronous Motor Drives

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE

International Journal of Advance Research in Engineering, Science & Technology

A Simple Position-Sensorless Algorithm for Rotor-Side Field-Oriented Control of Wound-Rotor Induction Machine

Real-time Simulation of Electric Motors

Control Scheme for Grid Connected WECS Using SEIG

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

CHAPTER 6 CONCLUSION

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Matlab Modeling and Simulation of Grid Connected Wind Power Generation Using Doubly Fed Induction Generator

Design of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

Doubly fed electric machine

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Asynchronous Generators with Dynamic Slip Control

CHAPTER 1 INTRODUCTION

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

International Journal of Advance Research in Engineering, Science & Technology. Comparative Analysis of DTC & FOC of Induction Motor

CONTROL OF DOUBLY FED INDUCTION GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS

Available online at ScienceDirect. Energy Procedia 42 (2013 ) Mediterranean Green Energy Forum MGEF-13

Possibilities of Distributed Generation Simulations Using by MATLAB

Permanent Magnet Synchronous Generator Based Standalone Wave Power Conversion System for Sustainable Power Supply at Perhentian Island.

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

Modelling and Simulation of DFIG based wind energy system

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

IMPROVEMENT IN DOUBLY FED INDUCTON GENERATOR UNDER FAULT USING INDUCTOR

PM Assisted, Brushless Wound Rotor Synchronous Machine

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

The Modeling and Simulation of Wind Energy Based Power System using MATLAB

CHAPTER 5 ANALYSIS OF COGGING TORQUE

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

IMPACT OF SKIN EFFECT FOR THE DESIGN OF A SQUIRREL CAGE INDUCTION MOTOR ON ITS STARTING PERFORMANCES

Modelling of Wind Turbine System by Means of Permanent Magnet Synchronous Generator Manjeet Kumar 1, Gurdit Singh Bala 2

SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator

Lab Electrical Power Engineering I

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

J.D ENGINEERING WORKS

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

Fachpraktikum Elektrische Maschinen. Theory of Induction Machines

Converteam: St. Mouty, A. Mirzaïan FEMTO-ST: A. Berthon, D. Depernet, Ch. Espanet, F. Gustin

1. RENEWABLE ENERGY I.SOLAR ENERGY PROJECT TITLES WE CAN ALSO IMPLEMENT YOUR OWN CONCEPT/IDEA

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Implementation of FC-TCR for Reactive Power Control

Transcription:

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM A THESIS Submitted in partial fulfilment of the requirements for the award of the degree of DOCTOR OF PHILOSOPHY in ALTERNATE HYDRO ENERGY CENTRE by FARHAD ILAHI BAKHSH ALTERNATE HYDRO ENERGY CENTRE INDIAN INSTITUTE OF TECHNOLOGY ROORKEE ROORKEE 247667, INDIA JANUARY, 2017

ABSTRACT Among various renewable energy resources, wind has been proven to be the most promising resource over the past few decades due its environment friendliness and sufficient potential to overcome the problems of energy shortage. The wind turbine generators (WTGs) employed for converting the wind energy into electrical energy are operated either at fixed-speed or at variable-speed mode. Among these two modes, the variable-speed mode is mostly preferred nowadays, as the torque can be held almost constant over a wide range of power by varying the speed. This alleviates the stresses imposed on the structural components and thus, the wind turbine can be made lighter and cheaper. Further, variable-speed WTGs have many advantages over fixed-speed WTG such as increased energy capture, operation at maximum power point, improved efficiency and power quality. A conventional variable-speed wind energy conversion system (WECS) consists of a wind turbine, gearbox, WTG and power electronic interface system. The power electronic interfacing is employed for integration of WECSs with grid or to supply isolated load, which is costly, incorporates sophisticated control, causes harmonic distortion and thereby deteriorates the quality of power supplied to grid or load. Therefore, suitable compensation is required in order to meet the standards for harmonic pollution which further increases the cost and complexity of the system. The average failure rate of power electronic conversion system is highest among other components of WECS. Further as, the wind speed does not remain constant, hence the repeated switching ON and OFF of WECS becomes very common which ultimately causes stress on the grid and may lead to stability related issues in the grid. Keeping in view the aforesaid problems of conventional method used for integration of WECS, the present study was planned with the following objectives: i) To identify a new integration technology for WECS which can address the above challenges and at the same time, provide effective utilization of wind power at small as well as large scales. ii) To study and investigate the concept and operation of the identified technology in detail. iii) To simulate the identified technology for integration of WECS. i

iv) To compare the proposed integration method for WECS with conventional method in terms of performance and cost. v) To develop an experimental setup of proposed integration method for WECS so as to validate the simulation results. vi) To perform steady state analysis of proposed integration method. In order to fulfill the above mentioned objectives, a new power transmission technology named as variable frequency transformer (VFT) is identified as a flexible AC link for connecting WTGs to the grid or load. VFT is basically a rotary transformer which transfers the electrical power in-between power system networks. The power flow through VFT can be regulated in terms of both magnitude and direction by controlling the torque of DC drive motor (DDM) coupled with the rotor of VFT. For analyzing the operation of VFT, its simulation model has been developed under MATLAB Simulink environment for power transfer in-between synchronous and in-between asynchronous grids. In this work, VFT is modeled as a doubly-fed wound rotor induction machine (WRIM) whose rotor is mechanically coupled to DDM. Among the two grids (#1 and #2), the grid #1 is connected to the stator side of VFT while grid #2 is connected to the rotor side of VFT. A DDM is used to apply torque to the rotor of VFT so as to regulate the power flow in-between these grids. From the simulation results, it is found that the magnitude and direction of power flow in-between the grids are controllable and directly proportional to the torque applied by DDM. In order to validate the simulation study, the experimental work has also been carried out. The trends of power flow in-between synchronous and asynchronous grids achieved from the experimental results are similar to that achieved from the simulation results. Thus, the concept and application of VFT as discussed in literature are verified by simulation and experimental studies. Further, a simulation model of controller has also been developed for closed loop control of power flow through VFT. Conducting simulation studies in presence of this controller, it is concluded that both the magnitude and direction of the power transfer in-between the synchronous and asynchronous grids are controllable by the controller. Further, for fault analysis of VFT during synchronous power transfer, three-phase fault has been simulated at two different locations (stator and rotor sides) of VFT (one at a time). From the obtained simulation results, it is concluded that when three-phase fault ii

occurs at either side of VFT, it works as an induction motor and instead of transmitting power it takes power from the healthy side. Moreover during fault, VFT doesn t contribute the fault current. After verifying the application of VFT for power transfer in-between synchronous and asynchronous grids, its application has been explored for grid integration of permanent magnet synchronous generator (PMSG) based WECS. The simulation model of the proposed method has been developed in MATLAB Simulink. From simulation results, it is observed that the power flow from PMSG to grid is proportional to the magnitude of applied torque to the rotor of VFT. The efficiency of power transfer through VFT also increases with the applied DDM torque, achieves a maximum value and then starts decreasing with the increase in magnitude of applied torque to its rotor. Further, a simulation model of controller has been developed which maintains the power flow from PMSG to grid at maximum efficiency point. The performance of modeled controller has been checked at different values of PMSG speed and found to be satisfactory. In order to compare the proposed method used for integration of WECS with conventional method, a digital simulation model of the conventional WECS has also been developed in MATLAB Simulink. From the comparison, it is observed that the proposed system is having almost similar efficiency but produces negligible harmonics as compared to the conventional system. Moreover, harmonics produced by the proposed system are within permissible limits thus the requirement of filter is omitted. Further, weight and cost of proposed system have been compared with the conventional system, which indicates that the proposed system is cheaper than conventional system but heavier in weight. After realizing the above concept on PMSG based WECS, a similar concept is extended for grid integration of wound rotor synchronous generator (SG) based WEGS. For this purpose, a digital simulation model of VFT for grid integration of SG based WEGS has been developed using MATLAB Simulink. The power flow from SG to grid under different torque conditions is analyzed using the developed model. From the simulated results, it is found that the active power flow from SG to grid is directly proportional to DDM torque. Also by controlling the applied DDM torque, VFT can be operated at its maximum efficiency. Further, a simulation model of controller has been developed which maintains the power flow from SG to grid at maximum efficiency point. iii

The performance of modeled controller has been analyzed at different values of SG speed and found to be satisfactory. In order to check the suitability of the proposed system, the performance of the proposed system at different values of SG speed have been compared with those by the conventional method in terms of total harmonic distortion (THD), efficiency, weight and cost. From comparison, it is observed that the efficiency of proposed system is almost similar to that of conventional system. However, the quality of voltage and current supplied to grid by the proposed system is much better in comparison to that of conventional system. Further, the comparison of weight (iron and copper) and cost required by proposed and conventional systems shows that proposed system requires more iron and copper than conventional system but cost of proposed system is less than conventional system. For validating the obtained results by simulation of proposed system, its experimental analysis has also been carried out. The trends of power flow from SG to grid and efficiency of the system achieved from the experimental work validate the simulation results. In the present energy scenario, due to high cost and complexity associated with the grid extension in remote and rural areas, small scale power generation has received greater attention to serve the local loads. Therefore, the application of VFT has been extended to feed isolated loads from WECS. For this purpose, a simulation model of VFT for integration of SG based WECS with isolated load has been developed under MATLAB Simulink environment with and without excitation control of SG. The simulation results show that with increase in SG speed, the difference between frequencies of input and output voltages of VFT decreases, thus DDM power required to maintain constant frequency at load end also decreases. Moreover, due to excitation control of SG, the load voltage is maintained constant at its rated value and hence constant load power is achieved. Thus, the proposed method is able to effectively utilize the small amount of power available at the output of SG and hence avoids the wastage of power due to the low value of wind turbine speed. Further, two controllers i.e. slip controller and excitation controller have been simulated for closed loop control of proposed scheme supplying an isolated load from SG based WECS. The use of both controllers in the simulation study shows that the modeled controllers are able to maintain the load voltage as well as its frequency constant at their rated values. Moreover, a comparison has been made between proposed and conventional iv

systems in terms of THD, efficiency, weight and cost. The comparison shows that the proposed system is cheaper, doesn t produce harmonics and having almost similar efficiency but heavier in weight than the conventional system. In order to validate the simulation study, the experimental work has also been carried out for the proposed system feeding an isolated load without excitation control of SG. From experimental results, it is found that with decreases in SG input speed, the SG output power decreases but DDM power increases in order to supply power to the constant load. The power fed to load increases linearly with DDM power. Moreover, by controlling the slip of VFT, the output frequency of voltage fed to the load is maintained constant at its rated value. On comparing the experimental results with simulation results, it is concluded that both the results are following similar trends. Finally, the steady state analysis of the proposed system used for feeding an isolated load is also carried out. For steady state analysis, first steady state equivalent circuit of VFT has been derived. Then, the developed equivalent circuit of VFT has been used for preparing the model of its application in standalone WECS. A set of equations has been derived from the model of proposed VFT application. Then a numerical based routine fsolve in the MATLAB is used for solving the set of equations. For validation of equivalent circuit of VFT, the experimental work has also been performed. The comparison shows that both results are in close agreement. After this, the analysis has been further extended for variable load under different values of SG speed and load power factor. As load power increases, the SG output power, DDM mechanical power, SG current and load current also increase. For a given load, as SG speed increases, DDM power decreases. For a lagging power factor load, SG has to generate more power and thus supplies more current than for unity or leading power factor load. The work presented in the thesis can be summarized as: The application of VFT has been analyzed for power transfer in-between synchronous and in-between asynchronous grids by simulation and experimental studies. Further, a controller has been simulated for achieving closed loop control of power flow through VFT. The developed simulation model is also used for analysis of VFT during three-phase fault. The application of VFT for grid integration of PMSG based WEGS is analyzed and compared with the conventional method in terms of performance, weight and cost by simulation studies. Further, a simulation model of controller has been v

developed which maintains the power flow from PMSG to grid at maximum efficiency point under different values of PMSG speed. The application of VFT for grid integration of wound rotor SG based WECS is analyzed by simulation and validated by the experimental work. A simulation model of controller has also been developed to operate the proposed system at maximum efficiency point under different values of SG speed. The proposed method for integration of WECS is also compared with the conventional method in terms of THD, efficiency, weight and cost. The application of VFT is extended for feeding an isolated load from wound rotor SG based WECS by simulation study. The experimental work is also carried out to validate the simulation results obtained without excitation control. Moreover, two controllers i.e. slip controller and excitation controller have been simulated for closed loop control of the proposed scheme. The performance, weight and cost of proposed method are also compared with that of conventional method for feeding an isolated load. The steady state analysis of VFT for feeding an isolated load from SG based WECS is carried out by deriving a set of equations from its model and then solving these equations using an iterative technique. For validation, the solutions obtained are compared with the experimental results. After this, the steady state analysis of VFT has been extended for variable load under different values of SG speed and load power factor. vi