Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

ISC Series Innovative Standard Cartridge Seals

User Instructions -Original Instruction-

Installation Instructions

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

Kämmer Series Low Flow Valve

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

E818/828 Series Fugitive Emissions 150# and 300# Flanged 2" - 8" Two-Piece Ball Valves Installation, Operation and Maintenance Instructions

McCANNA Actuation Systems B

Kämmer Series Low Flow Valves

Installation, Operation and Maintenance Instructions Series 608 Ball Valve

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

Valtek Flow Boosters

Kämmer Series Split Body Valves

Valtek Spring Cylinder Linear Actuators

TYPE 5615/5615Q SINGLE METAL BELLOWS CARTRIDGE SEAL

TYPE 5610V/5610VQ SINGLE O-RING CARTRIDGE SEAL

TYPE 5625/5625P DUAL METAL BELLOWS CARTRIDGE SEAL

Flow Solutions Division. ISC2PP Dual Pusher Seal ISC. Repair Instructions

225 CARTRIDGE DUAL SEAL

John Crane Type 5620 and 5620PR Dual O-Ring Cartridge Seal Assembly and Installation Instructions

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

Desuperheater FCD VLENTB /11. Experience In Motion

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

Limitorque Actuation Systems PT Series Worm Gear Operator

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Limitorque HBC Series Worm Gear Operators

Experience In Motion. Flowserve Control Valve Products North American Quick Response Centers

RVX Upgrade. ISO 13709/API 610 back pullout retrofit. Experience In Motion

155 CARTRIDGE SINGLE SEAL

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Worcester Controls Directional Ball Valves

OpTK. Product Instruction Manual. Spring Cylinder Rotary Actuators INTRODUCTION SAFETY INFORMATION INSTALLATION. Leading Technologies For Control

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves. Flowserve Corporation, Valtek Control Products, Tel. USA

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

TYPE 5611/5611Q ELASTOMER BELLOWS CARTRIDGE SEAL

USER INSTRUCTIONS. Valtek Control Products Spring Cylinder Linear Actuators. Installation Operation Maintenance. Experience In Motion

John Crane Type 5620 and 5620P Dual O-ring Cartridge Seal Assembly and Installation Instructions

Valtek Tek-Check Control Valves Valtek Tek-Check

250L Cartridge Dual Seal

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Rotary Valve Maxflo + 60 and 80 Opening type NT

255 Cartridge Dual Seal

Kämmer Multi-Z Severe Service Valves

Valtek Tek-Check. Check Valves

Valtek VL-HC Spring Cylinder Linear Actuators

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Metal Characterized-seated Control Valve 1. /4" 4" CPT 44 and 1 /2" 4" CPT 51/52 Installation, Operation and Maintenance Instructions

DELTA STYLE 9500 CARTRIDGE SPLIT SEAL INSTALLATION INSTRUCTIONS INTRODUCTION:

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

TYPE 5611/5611Q Elastomer Bellows Seals. ! Temperature: ! Pressure: 28 bar g/400 psig. ! Speed: ! End Play/Axial Float Allowance: 0.13mm/0.

Tri-Pac E325 / E525 Ball Valve Three-Piece Bolted Body, In-Line Maintainable, Regular and Full Port. McCANNA/MARPAC Valves RO400-R4

INSTALLATION, OPERATION & MAINTENANCE GUIDE

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

INSTALLATION, OPERATION & MAINTENANCE GUIDE

Flowserve Anchor Darling Isolation Valve Application

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

THD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

4410 TwinHydrostatic Gas Seal

TECHNICAL BULLETIN. Valdisk TX3 Triple Offset Butterfly Control Valve. Experience In Motion FCD VLENTB A4 1/16

Mark 100. Technical Bulletin F C D F C A T B

Logix 3800 Digital Positioner

250L Dual Cartridge Seal

S-17 CATALOG. Forged Steel Strainers

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

USER INSTRUCTIONS. Spring Diaphragm Rotary Actuators. Installation Operation Maintenance. Experience In Motion FCD VLAIM /12

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

USER INSTRUCTIONS. Serck Audco Slimseal Wafer-Type Butterfly Valves. Installation Operation Maintenance. Experience In Motion SREEIM /13

Flowserve Spring Diaphragm Rotary Actuators

INSTALLATION, OPERATION & MAINTENANCE GUIDE

Logix 3800 Digital Positioner

SY-SERIES S04DA75 THRU S06DA180 & S04SR75 THRU S06SR180 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

USER INSTRUCTIONS. Valtek Valdisk TX3 Triple Offset Butterfly Control Valve. Installation Operation Maintenance. Experience In Motion

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

Transcription:

Installation Instructions BW Seals Q, QB Series General Service Balanced Pusher Seal Q, QB, QBQ, QBS, QBU, QBQ LZ Experience In Motion

1 Equipment Check 1.1 Follow plant safety regulations: lock out motor and valves. wear designated personal safety equipment. relieve any pressure in system. consult plant MSDS files for hazardous material regulations. 1.2 Adjust the bearings, coupling, and impeller so that the shaft is in its operating axial position. This shaft position must be used to check all seal setting (SS) dimensions during installation. Disassemble equipment to allow access to seal installation area. 1.3 Remove all burrs, nicks or scratches, and sharp edges from the shaft and sleeve including sharp edges of keyways and threads. Replace worn shaft or sleeve. Make sure the seal housing bore, face, and sealing fluid flush taps are clean and free of burrs and sharp edges that might damage gasket. Seal Chamber Requirements Figure 1 To first obstruction Face of seal housing to be square to the axis of the shaft to within 0.013 mm per millimeter (0.0005 inches) of seal chamber bore FIM and have a 1.6 μm (63 μinch) R a finish or better Seal housing bore to have 3.2 μm (125 μinch) R a finish or better Scribe Mark B Sleeve or shaft finish to be 0.8 μm (32 μinch) R or better a Gland pilot can be at either of these register locations, concentric to within 0.13 mm (0.005 inch) FIM of shaft or sleeve OD Scribe Mark A Shaft or sleeve OD +0.000 mm (+0.000 inch) -0.050 mm (-0.002 inch) ANSI +0.000 mm (+0.000 inch) API 610/682-0.025 mm (-0.001 inch) DIN/ISO Bearings must be in good condition Maximum lateral or axial movement of shaft (end play) = 0.25 mm (0.010 inch) FIM Maximum shaft runout at face of seal housing = 0.05 mm (0.002 inch) FIM Maximum dynamic shaft deflection at seal housing = 0.05 mm (0.002 inch) FIM 1.4 Check requirements for shaft, sleeve, and seal housing. See Figure 1. 1.5 Check assembly drawing included with the seal for equipment dimensions, seal design, materials of construction, and piping connections. 1.6 Check shaft or sleeve OD, box depth, box bore, and distance to the first obstruction to ensure that they are dimensionally the same as shown on the seal assembly drawing. 1.7 Check gland pilot and bolt holes to ensure they are adaptable to the equipment and are the same as shown on the assembly drawing. 1.8 Handle all seal parts with care, they are manufactured to precise tolerances. The seal faces are of special importance. These two sealing faces are lapped flat to within two light bands (23.2 millionths of an inch). Keep the seal faces perfectly clean at all times. 2 The images of parts shown in these instructions may differ visually from the actual parts due to manufacturing processes that do not affect the part function or quality.

2 Assembly of Seal Components 2.1 Prepare rotating assembly for installation. The rotating assembly is comprised of the spring holder, springs, retaining ring, set screws, rotating face and rotating face gasket. Examine all parts - clean with alcohol or acetone as needed. Caution: Consult material safety data sheets for proper handling of alcohol or acetone. 2.1.1 Install the set screws into the spring holder. Caution: Set screws must not protrude into spring holder s bore. 2.1.2 Install the springs in the spring pockets of the spring holder. 2.1.3 Align the retaining ring with the drive keys, compress the springs and rotate the retaining ring so that the notches are no longer aligned with drive keys to retain springs. Check springs to make sure none are bent over. 2.1.4 Install the rotating face gasket in the recess of the rear of the rotating face. Lubricate the inside diameter of the rotating face gasket with silicone base grease only, unless otherwise specified on seal drawing. 2.1.5 Press down rotating face gasket making sure it is retained in the groove provided. 2.1.6 Install the rotating face in the spring holder with the slots in the face aligning with the keys. 2.2 The rotating assembly can now be installed on the shaft or sleeve. Use caution not to dislodge rotating face gasket. See Figure 2. Installed Seal Assembly on Shaft or Customer s Sleeve Figure 2 SS SS 3 Seal Setting for Seal on Shaft or Customer s Sleeve For proper seal installation, you must obtain the correct seal assembly drawing for your application. 3.1 Inspect pump shaft. Clean and remove any burrs, nicks, scratches, etc. which could cause damage to gaskets when assembling seal. 3.2 Secure the seal assembly in place at its correct seal setting position (SS) by tightening the rotating assembly set screws. See Figure 2. Refer to the seal assembly drawing for correct seal setting dimension. 3

3.3 O-ring Mounted Stationary Face 3.3.1 Assemble seat gasket to stationary face (lubricate gasket with silicone base grease only, unless otherwise specified on seal drawing) and install in gland. Caution: If anti-rotation pin is used, make sure stationary face is properly seated. Do not get grease on running face. 3.3.2 Install gland gasket - Use silicone grease if necessary to retain gasket. 3.4 Clamped Stationary Face 3.4.1 Install flat gasket into gland. 3.4.2 Install stationary face into gland. 3.4.3 Install second flat gasket to stationary face. Note: If two gasket materials are supplied, install PTFE gasket at this location. Use silicone grease to retain gasket if necessary. Do not get grease on running face. 3.5 Using lint free tissue, clean stationary and rotating face mating surfaces. Alcohol or acetone can be used as a cleaning agent to assure clean, film free, dry faces. Any other materials may cause premature seal failure. Caution: Consult material safety data sheets for proper handling of alcohol or acetone. 3.6 Assemble gland to seal chamber face. See Figure 2. Caution: During gland assembly over shaft, be sure stationary face is not damaged. Secure bolts attaching gland to housing. Note: Even torque is required on all gland bolts to assure proper seal operation. Tighten gland stud nuts evenly, cross stagger the adjustment of the nuts. Follow the equipment manufacturer s recommendation for gland stud nut torque. In the absence of recommendations, gland stud nuts should only be torqued to establish a leak tight seal at the gasket. Proper land bolt adjustment is especially important with clamp style inserts where torque may damage the insert. In this case, gland stud nuts should be torqued to a maximum of 13.5 N-m (10 ft-lbs). 4 Hook Sleeve Mount For proper seal installation, you must obtain the correct seal assembly drawing for your application. 4.1 Inspect pump shaft. Clean and remove any burrs, nicks, scratches, etc. which could cause damage to gaskets when assembling seal. 4.2 Assemble shaft sleeve and flat gasket to pump shaft and seat in accordance with pump manufacturer s specifications. Inspect for and remove any burrs. Seal Setting on Hook Sleeve Figure 3 4 SS

4.3 Verify seal setting (SS) reference dimension on the seal drawing. This is the dimension from the seal chamber face to a machined step or locator on the shaft. See Figure 3. 4.4 If shaft sleeve has no locating shoulder, blue sleeve and scribe line for location of spring holder as shown on seal assembly drawing. 4.5 Slide rotating assembly onto shaft sleeve, locating in accordance with the seal assembly drawing. Use caution not to dislodge rotating face gasket. 4.6 Tighten seal assembly set screws to shaft sleeve ensuring seal assembly is retained at proper seal setting location as noted on seal assembly drawing. 4.7 O-ring mounted Stationary Face 4.7.1 Assemble seat gasket to stationary face (lubricate gasket with silicone base grease only) and install in gland. Caution: If anti-rotation pin is used make sure stationary face is properly seated. Do not get grease on running face. 4.7.2 Install gland gasket, use silicon grease if necessary to retain gasket. 4.8 Clamped Stationary Face 4.8.1 Install flat gasket into inner gland. 4.8.2 Install stationary face into gland. 4.8.3 Install second flat gasket to stationary face. Note: If two gasket materials are supplied, install PTFE gasket at this location. Use silicone grease to retain gasket if necessary. Do not get grease on running face. 4.9 Using lint free tissue, clean stationary and rotating face mating surfaces. Alcohol or acetone can be used as a cleaning agent to assure clean, film free, dry faces. Any other materials may cause premature seal failure. Caution: Consult material safety data sheet for proper handling of alcohol or acetone. 4.10 Assemble gland to seal chamber face. See Figure 4. Caution: During gland assembly over shaft and sleeve, be sure stationary face is not damaged. Secure bolts attaching gland to housing. Note: Even torque is required on all gland bolts to assure proper seal operation. Tighten gland stud nuts evenly, cross stagger the adjustment of the nuts. Follow the equipment manufacturer s recommendation for gland stud nut torque. In the absence of recommendations, gland stud nuts should only be torqued to establish a leak tight seal at the gasket. Proper land bolt adjustment is especially important with clamp style inserts where torque may damage the insert. In this case, gland stud nuts should be torqued to a maximum of 13.5 N-m (10 ft-lbs). Installed Seal Assembly on Hook Sleeve Figure 4 5

5 Cartridge Mount 5.1 For proper seal installation you must have current seal assembly drawing for your application. 5.2 Inspect pump shaft. Clean and remove any burrs, nicks, scratches, etc., which could cause damage to gaskets when installing cartridge seal. 5.3 Carefully install the seal onto the shaft and locate against the face of the seal chamber. Take care not to impact the seal cartridge as damage to internal components can occur. 5.4 Orient ports on the seal cartridge as shown on the seal assembly drawing. 5.5 Evenly torque gland bolts/nuts to prevent uneven gland pressure against the seal chamber. 5.6 Adjust bearings, coupling, and impeller so that the shaft is in its final operating position. 5.7 Determine the type of setting device used by the seal design and follow the appropriate instructions. Type 1 - none Type 2 - setting plates Type 3 - setting blocks Type 1 (none) Figure 5 SS Gap (from assembly drawing) Determine proper seal setting (SS) gap specified on seal assembly drawing. Adjust sleeve drive collar position relative to gland to establish proper gap. Tighten drive collar set screws. Type 2 (setting plates) Figure 6 Setting Plate Bolt Setting Plate Set Screws 6 Tighten drive collar set screws to shaft. Loosen setting plate attachment bolts and rotate or slide setting plates clear of drive collar. Retighten setting plate attachment bolts.

Type 3 (setting blocks) Figure 7 Setting Block Tighten drive collar set screws to shaft. Loosen and remove setting blocks. 6 Piping Instructions Do not start up the equipment dry. Vent air from the casing of the pump and the seal chamber before startup. Refer to assembly drawing for mechanical seal piping instructions. Note: For special problems encountered during installation, contact your nearest Flowserve Sales and Service Representative or Authorized Distributor. 7 Repair This product is a precision sealing device. The design and dimension tolerances are critical to seal performance. Only parts supplied by Flowserve should be used to repair a seal. To order replacement parts, refer to the part code and B/M number. A spare backup seal should be stocked to reduce repair time. When seals are returned to Flowserve for repair, decontaminate the seal assembly and include an order marked "Repair or Replace." A signed certificate of decontamination must be attached. A Material Safety Data Sheet (MSDS) must be enclosed for any product that came in contact with the seal. The seal assembly will be inspected and, if repairable, it will be rebuilt, tested, and returned. 7

TO REORDER REFER TO B/M # F.O. FIS135eng REV 07/13 Printed in USA To find your local Flowserve representative and find out more about Flowserve Corporation, visit www.flowserve.com USA and Canada Kalamazoo, Michigan USA Telephone: 1 269 381 2650 Telefax: 1 269 382 8726 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2013 Flowserve Corporation Europe, Middle East, Africa Roosendaal, the Netherlands Telephone: 31 165 581400 Telefax: 31 165 554590 Asia Pacific Singapore Telephone: 65 6544 6800 Telefax: 65 6214 0541 Latin America Mexico City Telephone: 52 55 5567 7170 Telefax: 52 55 5567 4224 flowserve.com