Photovoltaic Modules Installation Manual for Australia

Similar documents
Product Manual. Installation Instructions for CHSM-230M Series Solar Module

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Crystalline Silicon PV Module Installation Guide (JET)

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

Safety and Installation Instructions

INSTALLATION MANUAL.

INSTALLATION MANUAL THE / MODULE. IEC & UL version

Installation Manual. Opal Solar QSA Series

Installation Manual AXITEC SOLAR MODULES

Photovoltaic Module User Manual

INSTALLATION MANUAL MODULE TSM-PDG5/PDG5(C) TSM-PEG5/PEG5(C) TSM-PEG40 THE. UL version IEC version. TSM_UL/IEC_IM_Dec_2014_RevB - 1 -

INSTALLATION MANUAL. For Monocrystalline Modules. According with IEC61215 edition 2 & IEC61730 standards

INSTALLATION AND SAFETY MANUAL for Cigs-2000A1 and Cigs-2000E1 Solar Photovoltaic Modules Release Date: Version: 1.1

Photovoltaic Module User Manual (CSA-UL1703)

INSTALLATION MANUAL ECOSOLARGY SOLAR MODULE

CRYSTALLINE SILICON PV MODULE INSTALLATION GUIDE THE POWER OF ASTRONERGY

Installation guide for Suntech Power photovoltaic module Purpose of this guide

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

JinkoSolar. Photovoltaic Module. User Manual (UL1703) 1500V

Installation. Guide. HSL Poly Series

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

Solar module user manual Conergy PM 225P-250P

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

Jinko Solar. Photovoltaic Module Eagle Dual. Installation Manual

Safety and Installation Instructions For Fluitecnik PV Modules

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

CRYSTALLINE SILICON PV MODULE INSTALLATION GUIDE THE POWER OF ASTRONERGY

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

PM220P00 / PM240P00 Installation Guide for Users

UL Installation guide for Suntech Power photovoltaic module

Installation Manual for the photovoltaic modules brand Eurener

JinkoSolar. Photovoltaic Module-Eagle Dual. Installation Manual

GENERAL INSTALLATION MANUAL

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

JinkoSolar. Photovoltaic Module. Installation Manual

PM300P00 Installation Guide for Users

JinkoSolar. Photovoltaic Module. Installation Manual

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

KD240GX-LFB2, KD245GX-LFB2 KD250GX-LFB2

Grape Solar Photovoltaic Modules. Safety and Installation Manual

JinkoSolar. Photovoltaic Module. User Manual (UL1703) 1500V

PV Module Installation Manual

AUO Photovoltaic Module Installation Manual. Version 2.0

Installation manual. For professional use only

Contents. VBHNxxxSJ40 series. VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT TM. VBHNxxxSJ40 series. VBHNxxxSJ25 series

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

Contents. VBHNxxxSJ40 series VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT R. VBHNxxxSJ25 series VBHNxxxSJ40 series

Version: GCLSI_ _V2. Photovoltaic Module Installation Manual for GCL System Integration Technology Co., Ltd.

JinkoSolar. Photovoltaic Module. Installation Manual

Solar Module Installation and User Manual

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

Installation and Operations Manual

Crystalline Silicon PV Module Installation Manual

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

Installation and Safety Manual

Installation Manual LIGHTWAY PV MODULES. Revision Date March 30, 2013 /Applicable for IEC certified products

Rev.A. Crystalline silicon solar photovoltaic modules INSTALLATION MANUAL. Please. future reference.

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

YINGLI SOLAR PV MODULES Installation and User Manual

INSTALLATION MANUALFOR RISEN SOLAR MODULE

Installation And User Manual SCHOTT PERFORM POLY SCHOTT PERFORM MONO

Assembly instructions

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

Suniva OPTIMUS Installation and Instruction Manual Introduction. Electrical Characteristics. Safety. Mounting Overview. Product Information

Philadelphia Solar Installation and Operation Manual

JA SOLAR INSTALLATION MANUAL

Installation Manual for LONGi Solar Modules

Installation and Maintenance Manual

photovoltaikforum.com

RITEK SOLAR PV MODULES Installation and User Manual

General Safety & Installation Instructions

General Installation Manual for POWERCOM Photovoltaic Modules

FLEXIBLE PHOTOVOLTAIC MODULES. Instruction Manual

Installation Instructions

AEG GLASS-GLASS SOLAR MODULES INSTALLATION MANUAL

Monocrystalline Solar Module LGXXXN1C(W, K)-G4. Installation Instructions MFL

HareonSolar PV module Installation Manual. Version

SOLAR SPOT Installation Guide

INSTALLATION MANUAL WAAREE ENERGIES LIMITED

250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

INSTALLATION MANUAL. The Solution in Black The Quadmax Solution Honey M The Aesthetic Solution The Comax Solution

Q/TW I Q/TW

OPTXXX-##-4-1YY IEC & UL EN Suniva, Inc. SI&IM _9 Rev 9 Page 1

INSTALLATION MANUAL Crystalline Photovoltaic Module

idealpv SSP1 220/270 Solar Panel

For our present, For their future. Version 11.03

SN SERIES 1,000V. EN ver 03_2017

POLYCRYSTALLINE SOLAR PANELS. (MC4 Series) P/No SPP80-MC4, SPP120-MC4, SPP135-MC4, SPP150-MC4

Installation Guide. X-tra modules

Green Building Technology

INSTALLATION MANUAL For crystalline solar photovoltaic modules According with IEC61215 edition 2 & IEC61730 standards

Grape Solar Photovoltaic Modules. User Manual

FOR JASOLARPHOTOVOLTAIC MODULES

Grape Solar Photovoltaic Modules. User Manual

Field Installation and Operation Manual for DC Smart Modules

Installation & Assembly. Panel SAM-CS6C-130P. Please read these instructions before installing and using this panel

Installation Instructions

Owner s Manual. Solar Controller GP-PWM-30

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Transcription:

Photovoltaic Modules Installation Manual for Australia ReneSola Jiangsu Ltd No.27, Qingyuan Road (East), Yixing Economic Development Zone, Yixing City Jiangsu Province, 214200 P.R. China Tel: +86-510-87129315 Fax: +86-510-87128056

Before installation, operation and maintenance be sure to read the instruction and use the photovoltaic module safely. This photovoltaic module produces electricity when exposed to light. Follow all applicable electrical safety precautions. WARNING ELECTRICAL HAZARD General use 1 Do not use the PV module where failure would result in death or fatal injury or damage property. 2 Confirm that PV module conforms to the requirements for the equipment used in the global system. 3 The modules are qualified for application class A: Hazardous voltage (IEC 61730: higher than 50V DC; EN 61730: higher than 120V), hazardous power applications (higher than 240W) where general contact access is anticipated (Modules qualified for safety through EN IEC 61730-1 and -2 within this application class are considered to meet the requirements for Safety Class II) 4 Artificially concentrated sunlight shall not be directed on the module. Handling 1 Handle the PV module with care. 2 Do not handle PV module when it is wet. 3 Do not drop the PV module. 4 Do not damage or scratch the rear surface of the PV module. The rear surface may be damaged by sharp objects. 5 Do not disassemble the PV module. 6 Do not walk on the PV module. 7 Do not touch live parts of cable or connectors. Use insulated tools and rubber gloves when touching them. Installation 1 Installers should be qualified personnel and be familiar with electricity and electric appliances. 2 Do not use damaged modules. The damaged PV module may cause a fire and/or an electrical shock that result in death of users or installers. 3 Artificially concentrated sunlight shall not be directed on the module or panel. 4 Cover the front surface of the PV module by an opaque cloth or other material when installing. The PV module exposed to sunlight generates high voltage and current. Contact with the module output wiring may cause a fire or an electrical shock. 5 Fasten the PV modules to the mounting structure respectively.

6 Install modules so as not to cause accidents that result in death, injury or any damage to property by accumulated snow falling from the PV module. 7 Don t disconnect under load. 8 Rated electrical characteristics are within 3 percent of measured values at Standard Test Conditions of: 1000 W/m 2, 25 C cell temperature and solar spectral irradiation of AM1.5 spectrum. 9 Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current and/or voltage than reported at standard test conditions. Accordingly, the value of Isc and Voc marked on this module should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. Product identification Nameplate: describes the product type; rated power, rated current, rated voltage, open circuit voltage, short circuit current, all as measured under standard test conditions; weight, dimension etc. the maximum system voltage 1000 or 1500 volts DC and is shown on the nameplate. Maximum fuse rating is also shown. CLIMATE CONDITION: Installing the PV module in the following conditions: Ambient temperature:-20 to +40. Operating temperature:-40 to +85. Snowfall pressure:test load is 5400Pa with certain mounting methods Wind speed:below 130km/h. Hail: could withstand the speed of 23m/s by the Ø 25 mm ice ball. Water resistance: don't install the PV module in a location where it would be immersed in water or continually exposed to water from a sprinkler or fountain etc. Corrosion resistance: except for corrosive salt area and sulfurous area. Orientation: 1 Install the PV module facing South (in Northern Hemisphere), or to North (in Southern Hemisphere). Module facing West or East can generate smaller amount of electricity than facing South (in Northern Hemisphere), or to North (in Southern Hemisphere). Incorrect orientation will result in loss of power output.

2 PV modules connected in series should be installed at same orientation and angle. Different orientation or angle may cause loss of output power due to difference of amount of sunlight exposed to the module. 3 Install the PV modules as free as possible from shading. Shading causes loss of output, even though the factory fitted bypass diode of the PV module will minimize any such loss. MOUNTING AND NOTES: 1 Do not install the PV module near naked flame or flammable materials. 2 Use mounting structures that can withstand forces from wind pressure and snowfall pressure specific to your installation area. 3 Use mounting structures that can withstand the environment where the PV modules are to be used. 4 Select proper materials and corrosive treatments. 5 Use appropriate methods or parts in addition to the following to fasten the module, when installing in high place from which fall of the module causes death, injury or damage to property. 6 Install the PV module with a space for draft behind the PV module to radiate heat. 7 For RNSAF001-004 and RNSAF00SA frame, there are 8 pre-drilled mounting holes on the frame. Use the 4 inner symmetry holes of the PV module to bolt to the mounting structure. If excessive wind or snow loads are expected, all eight mounting holes must be used. Fasten the aluminium frame using M8 or M6 stainless steel screw. Then a split locks washer and finally a nut to secure the entire assembly, as shown in the picture below. M8 bolt (set screw) Aluminium frame of the PV module M8 flat washer M8 flat washer Mounting structure M8 spring washer M8 nut Figure 1a Mounting method with bolts (For RNSAF001, RNSAF004, RNSAF00SA frame)

M6 bolt (set screw) Aluminium frame of the PV module M6 flat washer M6 flat washer Mounting structure M6 spring washer M6 nut Figure 2b Mounting method with bolts (For RNSAF002, RNSAF003 frame) 8 For RNSAF00H/V & RNSAF00HE/VE frame, there are 6 pre-drilled mounting holes on the frame (Horizontal), 4 pre-drilled mounting holes on the frame (Vertical). Use the all mounting holes. Fasten the aluminium frame using M4 stainless steel screw. Then a split locks washer and finally a nut to secure the entire assembly, as shown in the picture below.

9 The mounting design must be certified by a registered professional engineer. The mounting design and procedures shall comply with local codes and all authorities having jurisdiction. Grounding! WARNING 1 Grounding method should meet local code in accordance with specification of system. 2 Ground the module properly in accordance with mounting structures and environment. Refer to local code. 3 There is a grounding hole indicated with the symbol " " on frame. The area of cross-section of ground conductor should not be less than the primary current-carrying conductors 2.1mm 2, 10 or 12 AWG Conductor should be used. 4 All mounted module should be connected to ground reliably. It is required that the grounding method using a cup washer, a flat washer, an M4 nut and a tooth washer (the latter is to secure a proper galvanic connection through the aluminum oxide of the frame). Bypass diode In systems with more than two modules in series, high reverse current can flow through cells that are shaded partially or outright when part of a module is shaded and the rest is exposed to the sun. These currents can cause the affected cells to get very hot and could even damage the module. To protect module from such high reverse currents, by-pass diodes are used in module. In the unlikely event of diode failure, we recommend a qualified service technician be employed to determine if diodes have failed and to make replacement. Wiring! WARNING 1 Do not short the positive and negative cables.

2 Make sure connectors are fully engaged without a gap between the insulators. In case there is a gap, a fire and/or an electrical shock may occur. 3 Connect required number of PV modules to meet the voltage specification of equipment used in system. 4 Wire the output cable connectors so that they do not exert any strength on the PV module s junction box. Attach the cable to the mounting structure using approved fixings. 5 The PV module has a pair of male and female waterproof connectors. For a series electrical connection, connect positive (+) connector of the first PV module to the negative (-) connector of the following module. For a parallel electrical connection, connect positive (+) connector of the first PV module to the positive (+) connector of the following module. 6 Under normal conditions, the PV module is likely to experience conditions that produce more current and/or voltage than reported at standard test conditions. Accordingly, the values of Isc and Voc marked on this module should be multiplied by a factor of 1.25, when determining component voltage ratings, conductor capacity (cross sectional area), fuse sizes, and sizes of controls connected to the PV output. Customers should refer to the codes relevant to the location of installation for further guidance. Connect the output cable with equipment correctly. 7 Final output field wiring should be done with commercially available wiring product and minimum12awg cables rated for 90 C. In all cases, connectors to be used should never be a section less than 4mm 2. (More information in Annex 2) 8 The cables should be UV-resistant, and be secured to the mounting system. Protect exposed cables from damage by taking appropriate precautions, Avoid exposure to direct sunlight. 9 A minimum bending radius of 60 mm is required when securing the junction box cables to racking system. Installation of modules on the roof Modules are insured to be safely fixed and not to be destroyed by strong wind and heavy snow when the installation on the roof or buildings takes place. The assembly is to be mounted over a fire resistant roof covering rated for the application. It should be assured that the rear of the modules will be well ventilated for the cooling of the modules. When installing modules on the roof, the appropriate structure of the roof should be guaranteed. Besides, the penetrated roof must be properly covered when the modules are fixed in case that the rain leaks from the roof. In some events, special mounting is required. It is possible to affect the fire resistance of the roof by installing solar modules. The

recommended stand-off height is about 100 mm, if other mounting means are employed, this may affect the Listing for Fire Class Ratings. It is not suggested to install the modules on the roof or the buildings when strong wind or storm occurs in case of danger. Series and parallel connection Do not use modules of different configurations in the same system. The max number of module in series connection (N) Maximum system voltage / [Voc(at STC)*1.25]. and the max number of module in parallel connection (N) fuse current/ [Isc(at STC)*1.25] Several modules are connected in series and then in parallel to form a PV array, especially for application with a high operation voltage. If modules are connected in series, the total voltage is equal to the sum of individual voltages. For applications requiring high currents, several photovoltaic modules can be connected in parallel; the total current is equal to the sum of individual currents. Recommended number of modules in parallel connection is two. Maintenance 1 Do not touch the live parts of cables or connectors. Use appropriate safety equipment (insulated tools, insulating gloves, etc.) when touching them. 2 Cover the front surface of the PV module by an opaque cloth or other material when repairing. The PV modules when exposed to sunlight generate high voltage and are dangerous. Annual inspection 1 Check if nuts, bolts of mounting structure are secure and not loose. Tighten the loose component again, if required. 2 Check connections of cables, grounding cables and connectors. 3 Check all electrical and mechanical connections from freedom of corrosion. 4 Check the ground resistance of metal parts such as the module frames and the mounting structures.

Annex 1 Electrical Parameter and Drawings for 1500V system voltage modules Bb Series for 1500V system voltage (60 pieces of cells) Poly Crystalline Module type Maximum Pmax Imp Vmp Isc Voc System (W) (A) (V) (A) (V) Voltage (VDC) JC275M-24/Bbps 275 8.88 31.0 9.30 38.3 1500 JC270M-24/Bbps 270 8.80 30.7 9.21 38.1 1500 JC265M-24/Bbps 265 8.75 30.3 9.20 37.9 1500 JC260M-24/Bbps 260 8.62 30.2 9.19 37.8 1500 JC255M-24/Bbps 255 8.56 30.2 9.12 37.8 1500 JC250M-24/Bbps 250 8.45 30.0 9.04 37.5 1500 JC245M-24/Bbps 245 8.35 29.8 8.97 37.1 1500 *Overcurrent Protection: Listed Fuse Rating 20A.

Ab Series for 1500V system voltage (72 pieces of cells) Poly Crystalline Module type Pmax Imp Vmp Isc Voc Maximum System (W) (A) (V) (A) (V) Voltage (VDC) JC330M-24/Abps 330 8.78 37.6 9.34 46.1 1500 JC325M-24/Abps 325 8.72 37.3 9.29 45.8 1500 JC320M-24/Abps 320 8.68 36.9 9.20 45.6 1500 JC315M-24/Abps 315 8.63 36.5 9.14 45.4 1500 JC310M-24/Abps 310 8.60 36.1 9.11 45.1 1500 JC305M-24/Abps 305 8.50 36.1 9.05 45.1 1500 JC300M-24/Abps 300 8.45 36.0 9.03 45.0 1500 JC295M-24/Abps 295 8.36 35.7 8.93 44.8 1500 JC290M-24/Abps 290 8.30 35.5 8.89 44.7 1500 *Overcurrent Protection: Listed Fuse Rating 20A.

Annex 2 Electrical Parameter and Drawings for 1000V system voltage modules Bb Series for 1000V system voltage (60 pieces of cells) Poly Crystalline Module type Maximum Pmax Imp Vmp Isc Voc System (W) (A) (V) (A) (V) Voltage (VDC) JC275M-24/Bbs 275 8.88 31.0 9.30 38.3 1000 JC270M-24/Bbs 270 8.80 30.7 9.21 38.1 1000 JC265M-24/Bbs 265 8.75 30.3 9.20 37.9 1000 JC260M-24/Bbs 260 8.62 30.2 9.19 37.8 1000 JC255M-24/Bbs 255 8.56 30.2 9.12 37.8 1000 JC250M-24/Bbs 250 8.45 30.0 9.04 37.5 1000 JC245M-24/Bbs 245 8.35 29.8 8.97 37.1 1000 *Overcurrent Protection: Listed Fuse Rating 20A.

Ab Series for 1000V system voltage (72 pieces of cells with side length 156mm) Poly Crystalline Module type Pmax Imp Vmp Isc Voc Maximum System (W) (A) (V) (A) (V) Voltage (VDC) JC330M-24/Abs 330 8.78 37.6 9.34 46.1 1000 JC325M-24/Abs 325 8.72 37.3 9.29 45.8 1000 JC320M-24/Abs 320 8.68 36.9 9.20 45.6 1000 JC315M-24/Abs 315 8.63 36.5 9.14 45.4 1000 JC310M-24/Abs 310 8.60 36.1 9.11 45.1 1000 JC305M-24/Abs 305 8.50 36.1 9.05 45.1 1000 JC300M-24/Abs 300 8.45 36.0 9.03 45.0 1000 JC295M-24/Abs 295 8.36 35.7 8.93 44.8 1000 JC290M-24/Abs 290 8.30 35.5 8.89 44.7 1000 *Overcurrent Protection: Listed Fuse Rating 20A.

Annex 3 bypass diode information Bypass Diode Information Bypass diode PanJit International Inc. THY2550(1) Tj max =200 Remark: bypass diode could be used for both 1000V & 1500V system voltage modules