www. ElectricalPartManuals. com INSTRUCTIONS TYPE CT TEMPERATURE-OVERLOAD RELAY INSTALLATION OPERATION MAINTENANCE I.L

Similar documents
C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

B CW POWER RELAY

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

www. ElectricalPartManuals. com INSTRUCTIONS TYPE CO CONTACT MAKING AMMETER INSTALLATION OPERATION MAINTENANCE I.. L APPLICATION

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

P. Sub 4 184A404. Sub 3 876A220

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

41-747G. Figure 1: Type DGF Relay without case (Photo)

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

COM Overcurrent Relay

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

INSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

4.0 OPERATION Type ITH-T Relay

Type SOQ Negative Sequence Time Overcurrent Relay

www. ElectricalPartManuals. com INSTRUCTIONS TYPE HQS PHASE SELECTOR RELAY FOR INSTALLATION OPERATION MAINTENANCE APPLICATION

www. ElectricalPartManuals. com INSTRUCTIONS TYPE SX TOGGLE RELAY Westinghouse I.L C INSTALLATION OPERATION MAINTENANCE APPLICATION

INSTRUCTIONS GEK G HIGH-SPEED DIFFERENTIAL RELAYS TYPES CFD22A AND CFD22B. GE Protection and Control

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA UNDERVOL TAGE RELAYS TYPES: IAV54E IAV55C IAV54F IAV55F

INSTRUCTIONS SYNCHRONISM-CHECK RELAYS. GE Meter and Control. 205 Great Valley Parkway Malvern, PA Types IJS51A.

www. ElectricalPartManuals. com INSTRUCTIONS Westinghouse 1. L F TYPE CVQ RELAY OPERATION MAINTENANCE INSTALLATION APPLICATION

THERMAL OVER CURRENT RELAY

Industrial Control Transformers

RELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION REQUIREMENTS AND ADJUSTING PROCEDURES

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Instructions for De-Ion Air Circuit Breakers Types DM2R, DM2F

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Control Transformers

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com Type CO Overcurrent Relays E ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA

MODEL 422 Submersible Pump Controller


Instructions for Replacing

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

www. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

TESCO THE EASTERN SPECIALTY COMPANY Date: 05/04/15 Canal Street and Jefferson Avenue Bristol, PA 19007

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Transformer Installation, Operation, and Maintenance Manual

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

DISSECTIBLE TRANSFORMER - large

Voltmeter. for Experiments with the fischertechnik Expansion Kit. Order No

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Installation Sheet January, 2016 Supersedes February, 2013

Design Standard. Purpose: Design Standard:

www. ElectricalPartManuals. com INSTRUCTIONS TYPE KLF LOSS-OF-FIELD RELAY Westinghouse I.L B INSTALLATION OPERATION MAINTENANCE

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

ROTATING MAGNETIC FIELD

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

INSTR UCTIONS TYPE KA-4 CARRIER AUXILIARY RELAY FOR COMMONWEAIJTH EDISON COMPANY CAUTION

Adapted from presentation developed by Scott Fausneaucht

SECTION MOTOR CONTROL

Horizontal Circuit Switchers

Horizontal Circuit Switchers

INSTRUCT IONS GEH-1 793J INSTANTANEOUS AUXILIARY RELAY TYPES HGA11A, C, H, J, K, P, S, T, V, W, X GENERAL ELECTRIC AUILIARV P A GENERALS ELECTRIC

STARTER SYSTEM TESTING 5.6

INSTRUCTIONS GEI-98305C UNDERVOLTAGE RELAY D-C. Type NGV18A GENERAL ELECTRIC

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

TA Ta VA CTRL-XFRMR

Motor Protection Fundamentals. Motor Protection - Agenda

AC MOTOR TYPES. DESCRIBE how torque is produced in a single-phase AC motor. EXPLAIN why an AC synchronous motor does not have starting torque.

STARTER SYSTEM TESTING 5.6

Crane Control Class 9055

www. ElectricalPartManuals. com INSTRUCTIONS NO LOAD TAP CHANGER TYPE WSB-4 INSTALLATION OPERATION MAINTENANCE

34 th Hands-On Relay School

AUTOTRANSFORMER-TYPE STARTERS ALLEN-BRADLEY COMPANY REPLACEMENT PARTS AND PROCEDURES

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

www. ElectricalPartManuals. com MECHANICAL RELIEF DEVICE

GEK 45484B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAY HFA151 TYPE. GE Protection and Control 205 Great Valley Parkway Malvern, PA

EMaSM. Principles Of Sensors & transducers

INSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC

THE AUXILIARY EQUIPMENT OF THE CHICAGO, MILWAUKEE AND ST. PAUL LOCOMOTIVES

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

F O R M. Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors. 9055E Revised October 2015

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

AD-7. Instruction Manual. Thermal Indicating Ammeter HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Installation Sheet January, 2016 Supersedes June 2013

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Ch 4 Motor Control Devices

INSTALLATION INSTRUCTIONS

PT-150 PLUG-IN THERMAL RELAY WITH SNAP-ACTION BACK CONTACT *****************

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

Transcription:

CAUTION -,..- I.L. 41-551.1 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS TYPE CT TEMPERATURE-OVERLOAD RELAY Before putting relays into service, remove all blocking which may have been inserted for the purpose of securing the parts during shipment, make sure that all moving parts operate freely, inspect the contacts to see that they are clean and close properly, and operate the relay to check the settings and electrical connections. APPLICATION The Tyl)e CT relay is an induction type relay operating from exploring coils imbedded in or attached to the equipment being protected, and from a line current transformer. The relay is used to pro tect a-c equipment from overheating resulting from overloads, open phase, or insulation failure when the line current may be insufficient to operate short circuit protective devices. In order for the relay to operate, the temperature of the windings of the apparatus must be above values for which the relay is set, and these two conditions must have existed for a certain period of time because of the inherent timedelay of the induction-type unit. Thus, the danger of disconnecting the apparatus upon transient overloads is eliminated. for This relay is manufactured and set at the factory each application and cannot be changed after shipment. In order to make the application, the following information is necessary: 1. Frequency of the connected system. 2. Power rating of the apparatus being protected. 3. Full load phase current. 4. Current transformer ratio. This should be chosen so that the full load secondary current is between 3.25 and 5 amperes if possible. This permits use of a 5 C. differential between the balance temperature and the operating temperature. However, by using a differential of looc between the balance temperature and the operating temperature, a full load secondary current as low as 2.25 amperes can be permitted in 60 cycle applications. 5. Maximum safe operating temperature at which NEW INFORMATION the relay must trip if full load current or more is present. 6. The metal (usually copper) used in the exploring coil windings and its temperature coefficient of resistance at 25 Centigrade. 7. Resistance of each exploring coil at 25 Centigrade. (Standard relays are available for use with 10 ohm exploring coils only.) 8. Ambient temperature (if appreciably different from 25 C). 9. Resistance of the leads from the exploring coils to the relay terminals. However, if resistance of the leads can not be predetermined, the effect of lead resistance can be balanced out at slight sacrifice of sensitivity by using relays with additional terminals as shown in Fig. 3 and by using three leads to each exploring coil instead of two. CONSTRUCTION The type CT relay consists of an operating, element, two fixed resistor legs of the Wheatstone Bridge, and an indicating contactor switch unit. Operating Unit This unit is the induction-disc type. The induction disc is mounted on a vertical shaft. A stop riveted to the disc prevents the contact from opening more than approx. 1/4 of an inch. The shaft is sup ported on the lower end by a steel ball bearing riding between concave sapphire jewel surfaces, the upper end by a stainless steel pin. and on The moving contact is a small silver hemisphere fastened on the end of an arm. The other end of this arm is clamped to an insulated section of the disc shaft. The electrical connection is made from the moving contact thru the arm and spiral spring. end of the spring is fastened to the arm, One and the other to a slotted spring adjuster disc which in tum fastens to the element frame. The stationary contact assembly consists of a EFFECTIVE MAY 1957

TYPE CTRELAY ---- CURRENT TRANSFORMER 26-D-1333 Fig. l. Schematic Diagram of the Internal and External Connections ol the Type CT Relay. silver contact attached to the free end of a leaf spring. This spring is fastened to a Micarta block and mounted on the element frame. A small set screw permits the adjustment of contact follow. The moving disc is rotated by an electro-magnet in the rear and damped by an electro-magnet in the front. The upper pole windings are connected as the galvanometer leg of a Wheatstone Bridge circuit, and the lower pole winding in parallel with the Bridge as shown in Fig. 1. The lower pole winding and the Bridge as shown in Fig. 1. The lower pole winding and the bridge are energized from a current transformer connected to carry the load current of the apparatus being protected. Since the impedance of the bridge is largely resistance, and that of the lower winding almost entirely reactance, there is sufficient phase displacement between the currents in the two relay windings to give a positive rotational torque to the disc. Indicating Contactor Switch Unit (ICS) The d-e indicating contactor switch is a small clapper type device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the 2 switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers on the armature deflect a spring located on the front of the switch, which allows the operation indicator target to drop. The target is reset from the outside of the case by a push rod located at the bottom of the cover. The front spring, in addition to holding the target, provides restraint for the armature and thus controls the pickup value of the switch. OPERATION AND CHARACTERISTICS The operation of the relay is as follows with reference to Fig. 1. When the resistance of the exploring coils is increased by the rising temperature of the apparatus to equal the resistance of the fixed sides of the bridge, no current will flow thru the upper pole of the relay and there will be no torque. The relay is normally set at the factory so that the bridge circuit is balanced at either 5 or 100 Centigrade below the operating temperature which the customer sets as being the limit which he does not want to exceed. The relay is connected so that when the resistances of the exploring coils are higher than the critical resistance the torque is in the contact closing direction, and when less the torque is in the contact opening direction. Thus the relay will not trip on any load current as long as the temperature of the machine as indicated by the change in resistance of the exploring coil is within the safe limits. If the temperature rises above the safe limit, and the full load current is ex:::eeded, close. the relay contacts will The closing torque of the Type CT relay is approximately proportional to the product of the current squared and the temperature difference from the balance point. With the rise of these values above the operating limits, the relay contact close with a rapidly increasing force. The limited travel of the disc permits a very short operating time when the operating limits are exceeded considerably. When the resistance of the leads from the explor ing coils to the relay is known at the time the relay is manufactured, each of the two resistors of the bridge circuit is constructed with a resistance equal to that of the exploring coil at the balance temperature plus the resistance of one pair of leads. Since the lead resistance is not affected by the temperature of the exploring coil, the effect of appreciable lead resistance is to reduce the degree of unbalance

TYPE CT RELAY ---- L:.:...:!..-41!.:: 551.:!..1 IMDICATING CONTACTOR SWITCH- ---'-1 UPPER POLE COILS FROIIT YIEW CI1ASSIS OPERATED StiORTING SWITCH REDHAHDLE CURREnT TEST JACK TERMINAL 183All6 Fig. 2. Internal Schematic of the Type CT Relay In the Type FT2l Case 7 Terminal Relay for use where Exploring Coli Leacl Resistance is Known When Relay is Manufactured. of the bridge at temperatures above or below the balance point. However, lead resistances usually are less than 0. 5 ohm per pair, and the reduction in sensitivity would not be serious with lead resistances of 1.0 ohm. When the resistance of the leads from the exploring coils to the relay can not be determined accurately before the relay is manufactured, the CT relay can be used with internal connections as shown in Fig. 3. The upper pole winding (connected in the galvanometer circuit of the bridge) is connected to independent terminals, and three leads (instead of two) are required between the relay and each exploring coil. With this connection, the resistance of one lead is inserted in each exploring coil leg of the bridge, and the resistance of one lead is inserted in each relay resistor leg. Thus, the balance of the bridge is not affected by the lead resistance. However, the resistance of two leads is inserted in the galvanometer circuit. The relay is rendered somewhat less sensitive by this, but with lead resistance of 0.5 ohm each the operating temperature at full load would be raised less than 2"C above the temperature for zero lead resistance. The necessity of using a total of six leads instead of four may be objectionable in some cases, however. Trip Circuit The main contacts will safely close 30 amperes at 250 volts d-e and the seal-in contacts of the indilfidicating COIHACTOR SWITCH Fig. 3. ICS----- FROIIT YIEW LOWER POLE COIL Cr!ASSIS OPERATED SHORTIHU SWITC11 REDttAMOLE TEST SWITCH _CURREPH TEST JACk TERMINAL 183All7 Internal Schematic of the Type CT Relay in the Type FT2l Case 1 9-Termlnal Relay for use Where Exploring Coil Lead Resistance is Unknown When Relay Is Manufactured. eating contactor switch will safely carry this current long enough to trip a ci,rcuit breaker. The indicating contactor switch has two taps that provide a pickup setting of 0.2 or 2 amperes. To change taps requires connecting the lead located in front of the tap bloc\{ to the desired setting by means of a screw connection. Trip Circuit Constant Indicating Contactor Switch (ICS) 0.2 ampere tap 6.5 ohms d-e resistance 2.0 ampere tap 0.15 ohms d-e resistance EXPLORING COl LS It is preferable to use exploring coils which are built into the apparatus to be protected at the time of manufacture as they can be placed in the winding slots or otherwise brought into proximity to the windings being protected close to the point of highest temperature rise. The physical design of these coils will vary with the individual apparatus, but exploring coils usually are copper, with a resistance of 10 ohms at 25 C. If a motor or generator has been built without exploring coils and it is desired to provide temperatureoverload protection by means of the type CT relay, a Rope Coil'" may be fastened to the end connections 3

TYPE CT RELAY I 2 3 of the windings. '---- -- -- -- - ----- -- J 7- TERMINAL RELAY FOR USE WHERE EXPLORING COIL LE AD RESI STANCE IS KNOWN WHEN REL AY IS MANUFACTURED 9-TERMIN AL REL AY FOR USE WHEN EXPLORING COIL LEAD RESISTAN CE IS UNKNOWN WHEN RELAY IS MANUFA CTURED EC NEG----- [;>cvice NU MBE R CH ART 49 TEMPERATURE OVERLOA D REL AY TYPE CT LP-LOWER POLE COILS UP-UPPER POLE COILS ICS-INDICATOR CONTACTOR SWI TCH 52-POWER CIRCUIT BRE AKER TC- BREA KER TRIP COIL -BREAKER AUXILI AR Y CONTACT EC-EXPLORING Fig. 4. External Schematic of the Type CT Temperator Overload Relay, Because of its location it can not indicate the winding temperature as accurately as a built-in exploring coil. The "Rope Coil is a flat loop or skein of wire approximately 10 feet long. Two strands of enameled copper wire are wound in parallel and four leads are brought out, providing the two exploring coil sides of the bridge in the one winding. The coil then is insulated with a tape winding and is varnish dipped and baked. It is sufficiently flexible to permit placing and tying it around the end connections of the winding. INSTALLATION The relays should be mounted on switchboard panels or their equivalent in a location free from dirt, moisture, excessive vibration, and heat. Mount the relay vertically by means of the four mounting holes on the flange for semi-flush mounting or by means of the rear motlnting stud or studs for projection mounting. Either a mounting stud or the mounting screws may be utilized for grounding the relay. 4 The COIL electrical connections may be made directly to the terminals by means of screws for steel panel mounting or to the terminal studs furnished with the relay for thick panel mounting. The terminal studs may be easily removed or inserted by locking two nuts on the wrench. 41-076. stud and then turning the proper nut with a For detailed FT case information refer to I.L. AD JUSTMENTS AND MAINTENANCE All contacts should t>e periodically cleaned. A contact burnisher S#182A836H01 is recommended for this purpose. The use of abrasive material for cleaning contacts is not recommended, because of the danger of embedding small particles in the face of the soft silver and thus impairing the contact. The proper adjustments to insure correct operation of this relay have been made at the factory and should not be disturbed after receipt by the customer.

J \ TYPE CTRELAY L - 1 5 51.1 Fig. 5. (FRONT VIEW) ( I lrl 1 l-[j-- LOAD ; j_ RESISTOR 52 I I!!;( 120 V 60 CYC ;---------t SUPPLY, --- SI -S2 - NON-INDUCTIVE SLIDE RESISTORS ADJUSTABLE FROM 10 TO APPROX IS OHMS OR LESS. SLIDE MUST HAVE NEGLIGIBLE CONTACT RESISTANCE 183A478 DiCJgram of Test Connections lor the Type CT ReiCJy In Type FT2l Case. If the adjustments have been changed, the relay taken apart for repairs, or if it is desired to check the adjustments at regular maintenance periods, the instructions below should be followed. OperCJting Coil To check the operating coils, connect the relay per Fig. 5. and The relay should trip at "A" amperes "T" degrees C. as marked on its nameplate. The temperature may be represented by increasing the resistance of the exploring coil sides of the bridge by means of slide wire resistances, to the values corresponding as shown in the following table: A Resistance TempeTature Resistance Temperature 10.00 ohms 25 C. 12.89 100 10.96 50 13.28 110 11.35 60 13.66 120 11.73 70 14.05 130 12. 12 80 14.43 140 12.50 90 14.82 150 A NOTE - This table applies only to copper wire coils having 10 ohms resistance at 25 C. Indicating Contactor Swi tch (ICS) Close the main relay contacts and pass sufficient d-e current through the trip circuit to close the contacts of the ICS. This value of current should not be greater than the particular ICS tap setting being used. The indicator target should drop freely. RENEWAL PARTS Repair work can be done most satisfactorily at the factory. furnished,doing repair work. However, interchangeable parts can be to the customers who are equipped for the complete nameplate data. When ordering parts, always give ENERG Y REQUIREMENTS The 60 cycle burden of the relay on the current transformer is 15.0 volt-amperes at 5 amperes, 49 lag Power Factor. The continuous rating of the winding is 5 amperes (10 ohms exploring coil), and the one second rating 150 amperes, 60 cycles. 5

TYPE CTRELAY 6 i,tg0-32. SCREW SPACER FOR THIN PANEL';. -16SCREW IG (FOR \1-\IC\0<. PANEL USE -IB 'SIUD) 90-3'ZSCR.EW (FOR T\-1\CK. PANEL Ut;.E.I 0-32 STUD) 4PIA.. TERMINAL A.ND MC\JNTIN<:,- Dt:i IL'S Fig, 6. t -I (J\ PANEL CUTOUT t DR.ILL\ G F"OR 5EMI-FLU5\4 'MTG-, I 13L l DIJ>-..4-HOLE.S FOR 4.190-3'2. MTC:r. SCREW$ I 13i PANEL DR\LL\ NG- OR CUTOUT PROJE.CT\ON MTG. (FRONT V\EW) FOR Outline and Drilling Plan for the Type CT Relay In the Type FT2J Case, 57-D-7901 \

WESTINGHOUSE ELECTRIC METER DIVISION CORPORATION NEWARK, N.J. Printed in U.S A. I. I '

CAUT IOH I.L. 41-551. 1A INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS TYPE CT TEMPERATURE-OVERLOAD RELAY Before putting relays into service, remove all blocking which may have been inserted for the purpose of securing the parts during shipment, make sure that all moving parts operate freely, inspect the contacts to see that they are clean and close properly, and operate the relay to check the settings and electrical connections. APPLICATION The Type CT relay is an induction type relay operating from exploring coils imbedded in or attached to the equipment being protected, and from a line current transformer. The relay is used to protect a-c equipment from overheating resulting from overloads, open phase, or insulation failure when the line current may be insufficient to operate short circuit protective devices. In order for the relay to operate, the temperature of the windings of the apparatus must be above values for which the relay is set, and these two conditions must have existed for a certain period of time because of the inherent time- delay of the induction-type unit. Thus, the danger of disconnecting the apparatus upon transient overloads is eliminated. This relay is manufactured and set at the factory for each application and cannot be changed after shipment. In order to make the application, the fol lowing information is necessary: 1. Frequency of the connected system. 2. Power rating of the apparatus being protected. 3. Full load phase current. 4. Current transformer ratio. This should be chosen so that the full load secondary current is between 3.25 and 5 amperes if possible. This permits use of a 5 C. differential between the balance temperature and the operating temperature. However, by using a differential of 10 C between the balance temperature and the operating temperature, a full load secondary current as low as 2.25 amperes can be permitted in 60 cycle applications. 5. Maximum safe operating temperature at which SUPERSEDES I. L. 41-551. 1 *Denotes change from superseded issue. * the relay must trip if full load current or more is present. 6. The metal (usually copper) used in the exploring coil windings and its temperature coefficient of resistance at 25 Centigrade. 7. Resistance of each exploring coil at 25 Centigrade. (Standard relays are available for use with 10 ohm exploring coils only.) 8. Ambient temperature (if appreciably different from 25 C). 9. Resistance of the leads from the exploring coils to the relay terminals. However, if resistance of the leads can not be predetermined, the effect of lead resistance can be balanced out at slight sacrifice of sensitivity by using relays with additional terminals as shown in Fig. 3 and by using three leads to each exploring coil instead of two. CONSTRUCTION The type CT relay consists of an operating unit, two fixed resistor, and an indicating contact or switch unit. Operating Unit This unit is the induction-disc type. The induction disc is mounted on a vertical shaft. A stop riveted to the disc prevents the contact from opening more than approx. 1/4 of an inch. The shaft is supported on the lower end by a steel ball bearing riding between concave sapphire jewel surfaces, the upper end by a stainless steel pin. and on The moving contact is a small silver hemisphere fastened on the end of an arm. The other end of this arm is clamped to an insulated section of the disc shaft. The electrical connection is made from the moving contact thru the arm and spiral spring. One end of the spring is fastened to the arm, and the other to a slotted spring adjuster disc which in tum fastens to the element frame. The stationary contact assembly consists of a EFFECTIVE APRIL 1959

'*' TYPE CTRELAY Fig. l. CURRENT TRANSFORMER 26-D-1333 Schematic Diagram of the Internal ancl External Connections of the Type CT Relay. silver contact attached to the free end of a leaf spring. This spring is fastened to a Micarta block and mounted on the element frame. A small set screw permits the adjustment of contact follow. Indicating Contactor Switch Unit (ICS) The d-e indicating contactor switch is a small clapper type device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers on the armature deflect a spring located on the front of the switch, which allows the operation indicator target to drop. The target is reset from the outside of the case by a push rod located at the bottom of the cover. The front spring, in addition to holding the target, provides restraint for the armature and thus controls the pickup value of the switch. OPERATION AND CHARACTERISTICS 2 The relay is connected as a Wheatstone Bridge to the protected apparatus as shown in Fig. 1. Since the impedance of the bridge is resistance, and that of the lower pole winding reactance, there is sufficient phase displac ement between the currents in the two windings of the relay to give a positive torque to the disc. The lower pole winding of the relay is energized by load current of the protected apparatus while the upper pole winding is energized by current flowing as a result of an unbalance in the Wheatstone Bridge. When the temperature of the protected apparatus is lower than the critical temperature, the resistance of the exploring coils is less than the fixed resistors of the relay. This unbalances the Bridge and causes a current to flow in the upper pole winding of the relay. The direction of this current in relationship to the lower pole current is such that a contact opening torque is produced on the disc. When the temperature of the protected apparatus is greater than the critical temperature, the resistance of the exploring coils is greater than the fixed resistors of the relay. The Wheatstone Bridge is unbalanced, and a current flows in the upper pole of the relay. The direction of this current in relationship to the lower pole current is such that a control closing torque is produced on the disc. When the temperature of the protected apparatus is the same as the critical temperature, all resistances of the Wheatstone Bridge are equal. As a result, current will not flow in the upper pole winding and torque will not be produced on the disc. The relay is calibrated at the factory for a specific value of operating temperature and current. The balance temperature is usually set to be 5 to 10 C below the desired tripping temperature. The closing torque of the Type CT relay is approximately proportional to the product of the current squared and the temperature difference from the balance point. With the rise of these values above the operating limits, the relay contact close with a rapidly increasing force. The limited travel of the disc permits a very short operating time when the operating limits are exceeded considerably. When the resistance of the leads from the exploring coils to the relay is known at the time the relay is manufactured, each of the two resistors of the bridge circuit is constructed with a resistance equal to that of the exploring coil at the balance temperature plus the resistance of one pair of leads. Since

TYPE CT RELAY ------------------------------ L_._4_1 -_55_1_ 1_A IMDICATIIIG COMTACTOR SWITCH -- ----'"-' ICS)+-----, frotit YlfW LOWER POLE COIL CHASSIS OPERATED SHORTIPI6 SWITCH REO HANDLE TEST SWITCI1 CURRErH TEST JACK TERJolhiAL 183All6 Fig. 2. Internal Schematic of the Type CT Relay In the Type FT2J Case 1 Termlnal Relay for use where Exploring Coli Lead Resistance Is Known When Relay is Manufactured, the lead resistance is not affected by the temperature of the exploring coil, the effect of appreciable lead resistance is to reduce the degree of unbalance of the bridge at temperatures above or below the balance point. However, lead resistances usually are less than 0. 5 ohm per pair, and the reduction in sensitivity would not be serious with lead resistances of 1.0 ohm. When the resistance of the leads from the exploring coils to the relay can not be determined accurately before the relay is manufactured, the CT relay can be used with internal connections as shown in Fig. 3. The upper pole winding (connected in the galvanometer circuit of the bridge) is connected to independent terminals, and three leads (instead of two) are required between the relay and each exploring coil. With this connection, the resistance of one lead is inserted in each exploring coil leg of the bridge, and the resistance of one lead is inserted in each relay resistor leg. Thus, the balance of the bridge is not affected by the lead resistance. However, the resistance of two le!l;ds is inserted in the galvanometer circuit. The relay is rendered somewhat less sensitive by this, but with lead resistance of 0.5 ohm each the operating temperature at full load would be raised less than 2"C above the temperature for zero lead resistance. The necessity of using a total of six leads instead of four may be objectionable in some cases, however. IMDICATIMG COMTACTOR SWITCH Fig. 3. Trip Circuit ICS)+----, front YlfW UPPER POLE COILS LOWER POLE COIL Cr1ASSIS OPERATED SHORTIMU SWITCri RED HA.. DlE TEST SWITCH _CURREJH TEST JACk 183All7 Internal Schematic of the Type CT Relay in the Type FT2J Case ' 9 Termlnal Relay for use Where Exploring Coil Lead Resistance Is Unknown When Relay Is Manufactured. The main contacts will safely close 30 amperes at 250 volts d-e and the seal-in contacts of the indicating contactor switch will safely carry this current long enough to trip a circuit breaker. The indicating contactor switch has two taps that provide a pickup setting of 0.2 or 2 amperes. To change taps requires connecting the lead located in front of the tap block to the desired setting by means of a screw connection. Trip Circuit Constant Indicating Contactor Switch (ICS) 0.2 ampere tap 6.5 ohms d-e resistance 2.0 ampere tap 0. 15 ohms d-e resistance EXPLORING COl LS It is preferable to use exploring coils which are built into the apparatus to be protected at the time of manufacture as they can be placed in the winding slots or otherwise brought into proximity to the windings being protected close to the point of highest temperature rise. The physical design of these coils will vary with the individual apparatus, but exploring coils usually are copper, with a resistance of 10 ohms at 25 C. 3

TYPE CTRELAY --- I 2 3 --- --- -- l...- ---, EC '----- - -J 7-T ERMINAL RELAY FOR USE WHERE EXPLORING COIL LEAD RESISTANCE IS KNOWN WHEN RELAY IS MANUFACTURED Fig. 4.. If a motor or generator has been built without exploring coils and it is desired to provide temperatureoverload protection by means of the type CT relay, a Rope Coil'" may be fastened to the end connections of the windings. 49 9 9-TERMINAL RELAY FOR USE WHEN EXPLORING COIL LEAD RESISTANCE IS UNKNOWN WHEN RELAY IS MANUFACTURED EC NEG --- DEVI CE NUMBER CHART 49:fEMPERATURE OVERLOAD RELAY TYPE CT LP-LOWER POLE COILS UP-UPPER POLE COILS ICS-INDICATOR CONTACTOR SWI TCH 52-POWER CIRCUIT BREAKER TC- BREAKER TRIP COIL -BREAKER AUXILIAR Y CONTACT EC-EXPLORING COIL External Schematic of the Type CT Temperature Overload Rela. Because of its location it can not indicate the winding temperature as accurately as a built-in exploring coil. The Rope Coil" is a flat loop or skein of wire approximately 10 feet long. Two strands of enameled copper wire are wound in parallel and four leads are brought out, providing the two exploring coil sides of the bridge in the one winding. The coil then is insulated with a tape winding and is varnish dipped and baked. It is sufficiently flexible to permit placing and tying it around the end connections of the winding. panels INSTALLATION The relays should be mounted on switchboard or their equivalent in a location free from dirt, moisture, excessive vibration, and heat. Mount the relay vertically by means of the four mounting holes on the flange for semi-flush mounting or by means of the rear mounting stud or studs for projec- 4 183A477 tion mounting. Either a mounting stud or the mounting screws may be utilized for grounding the relay. The electrical connections may be made directly to the terminals by means of screws for steel panel mounting or to the terminal studs furnished with the relay for thick panel mounting. The termii;tal studs may be easily removed or inserted by locking two nuts on the wrench. 41-076. stud and then turning the proper nut with a For detailed FT case information refer to I.L. ADJUSTMENTS AND MAINTENANCE All contacts should be periodically cleaned. A contact burnisher S#182A836H01 is recommended for this purpose. The use of abrasive material for cleaning contacts is not recommended, because of the danger of embedding small particles in the face of the soft silver and thus impairing the contact. The proper adjustments to insure cor. ct operation of this relay have been made at the factory and should not be disturbed after receipt by the customer.

TYPE CT RELAY 1 L_._4_1 _55_1_ 1_A (FRONT ViEW) L J II l rfl I 1 1 l LJ 120 V 60 CYC; --, SUPPLY 51,-------. _ A lcyload. RESISTOR SI-S2 - NON-INDUCTIVE SLIDE RESISTORS ADJUSTABLE FROM 10 TO APPROX IS OHMS OR LESS. SLIDE MUST HAVE NEGLIGIBLE CONTACT Fig. S. Diagram of Test Relay in Type FT2J Case. ' RESISTANCE Connections for the Type CT If the adjustments have been changed, the relay taken apart for repairs, or if it is desired to check the adjustments at regular maintenance periods, the instructions below should be followed. Operating Coil To check the operating coils, connect the relay per Fig. 5. The relay should trip at "A" amperes and "T" degrees C. as marked on its nameplate. The temperature may be represented by increasing the resistance of the exploring coil sides of the. bridge by means of slide wire resistances, to the values corresponding as shown in the following table: A Resistance T empe'fature Resistance Temp eroture 10.00 ohms 25 C. 12.89 100 10.96 50 13.28 110 H.35 60 13.66 120 11.73 70 14.05 130 12.12 80 14.43 140 12. 50 90 14.82 150 A NOTE - This table applies only to copper wire coils having 10 ohms resistance at 25 C. Indicating Contactor Switch (ICS) Close the main relay contacts and pass sufficient d-e current through the trip circuit to close the con tacts of the ICS. This value of current should not be greater than the particular ICS tap setting being used. The indicator target should drop freely. RENEWAL PARTS Repair work can be done most satisfactorily at the factory. However, interchangeable parts can be furnished to the customers who are equipped for,doing repair work. When ordering parts, always give the complete nameplate data. ENERGY REQUIREMENTS The 60 cycle burden of the relay on the current transformer is 15.0 volt-amperes at 5 amperes, 49 lag Power Factor. The continuous rating of the winding is 5 amperes (10 ohms exploring coil), and the one second rating 150 amperes, 60 cycles. 5

TYPE CTRELAY _ 6 --&PIA. 190-32. SCREW TERMINAL AND MCUNTINq. DEiAIL'5 SPACER FOR THIN PANELS -16SCRE.W IG (FOR \1-'.ICK PANEL USE f6 18 STUD) 190-S'ZSCI<.E.W (FOR. T\-1\CK. PA.NEL U'SE.190 32 STUD) PANEL CUTOIJT i DRILL\WG F"OR SEM\-F'LU \-4 MTG- I 13 l DIJ>-..4-HoLE.S FOR +.190 3'2. MT<::.. SCREW$ I 13?- PANEL OR\LLI N<i OR CUTOUT FOR. PR.OJECT\ON MTG. (FRONT V\EW) Fig. 6. Outline anj Drilling Plan for the Type CT Relay in the Type FT27 Case. TER IIINAI.. NUMaE:R 57-D-7901

TYPE CT RELAY I. L::..: 4 1 :=55 1.1 A 1 11:: Fig. 7. 1(;1Pe CT Relay 1 -Balancing Resistor. 2 -Moving Contact Assembly. 3- Stationary Contact Assembly. 4- In clfcatlng Contactor Switch (ICS). 7

WESTINGHOUSE ELECTRIC CORPORATION RELAY DEPARTMENT NEWARK, N. J. Printed in U. S. A.

INSTALLATION Westinghouse I.L. 41-551.1A OPERATION MAINTENANCE INSTRUCTIONS TYPE CT TEMPERATURE-OVERLOAD RELAY CAUTION Before putting relays into service, remove all blocking which may have been inserted for the purpose of securing the parts during shipment, rnak e sure that all moving parts operate freely, inspect the contacts to see that they are clean and close properly, and operate the relay to check the settings and electrical connections. APPLICATION The Type CT relay is an induction type relay operating from exploring coils imbedded in or attached to the equipment being protected, and from a line current transformer. The relay is used to protect a-c equipment from overheating resulting from overloads, open phase, or insulation failure when the line current may be insufficient to operate short circuit protective devices. In order for the relay to operate, the temperature of the windings of the apparatus must be above values for which the relay is set, and these two conditions must have existed for a certain period of time because of the inherent timedelay of the induction-type unit. Thus, the danger of disconnecting the apparatus upon transient overloads is eliminated. This relay is manufactured and set at the factory for each application and cannot be changed after shipment. In order to make the application, the following information is necessary: 1. Frequency of the connected system. 2. Power rating of the apparatus being protected. 3. Full load phase current. 4. Current transformer ratio. This should be chosen so that the full load secondary current is between 3.25 and 5 amperes if possible. This permits use of a 5 C. differential between the balance ternperature and the operating temperature. However, by using a differential of 10 C between the balance ternperature and the operating temperature, a full load secondary current as low as 2.25 amperes can be permitted in 60 cycle applications. 5. Maximum safe operating temperature at which SUPERSEDES I.L. 41-551.1 *Denotes change from superseded issue. : < the relay must trip if full load current or more is present. 6. The metal (usually copper) used in the exploring coil windings and its temperature coefficient of resistance at 25 Centigrade. 7. Resistance of each exploring coil at 25 Centigrade. (Standard relays are available for use with 10 ohm exploring coils only.) 8. Ambient temperature (if appreciably different from 25 C). 9. Resistance of the leads from the exploring coils to the relay terminals. However, if resistance of the leads can not be predetermined, the effect of lead resistance can be balanced out at slight sacrifice of sensitivity by using relays with additional terminals as shown in Fig. 3 and by using three leads to each exploring coil instead of two. CONSTRUCTION The type CT relay consists of an operating unit, two fixed resistor, and an indicating contact or switch unit. Operating Unit This unit is the induction-disc type. The induction disc is mounted on a vertical shaft. A stop riveted to the disc prevents the contact from opening more than approx. 1/4 of an inch. The shaft is supported on the lower end by a steel ball bearing riding between concave sapphire jewel surfaces, and on the upper end by a stainless steel pin. The moving contact is a small silver hemisphere fastened on the end of an arm. The other end of this arm is clamped to an insulated section of the disc shaft. The electrical connection is made from the moving contact thru the arm and spiral spring. One end of the spring is fastened to the arm, and the other to a slotted spring adjuster disc which in turn fastens to the element frame. The stationary contact assembly consists of a EFFECTIVE OCTOBER 1961

TYPE CTRELAY Fig. 1. RELAY RESISTOR CURRENT TRANSFORMER -----, r----- 26-D-1333 Schematic Diagram of the Internal and External Connections of the Type CT Relay. silver contact attached to the free end of a leaf spring. This spring is fastened to a Micarta block and mounted on the element frame. A small set screw permits the adjustment of contact follow. Indicating Cantactor Switch Unit (ICS) The d-e indicating contactor switch is a small clapper type device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers on the armature deflect a spring located on the front of the switch, which allows the operation indicator target to drop. The target is reset from the outside of the case by a push rod located at the bottom of the cover. The front spring, in addition to holding the target, provides restraint for the armature and thus controls the pickup value of the switch. OPERATION AND CHARACTERISTICS * The relay is connected as a Wheatstone Bridge 2 to the protected apparatus as shown in Fig. 1. Since the impedance of the bridge is resistance, and that of the lower pole winding reactance, there is sufficient phase displac ement between the currents in the two windings of the relay to give a positive torque to the disc. The lower pole winding of the relay is energized by load current of the protected apparatus while the upper pole winding is energized by current flowing as a result of an unbalance in the Wheatstone Bridge. When the temperature of the protected apparatus is lower than the critical temperature, the resistance of the exploring coils is less than the fixed resistors of the relay. This unbalances the Bridge and causes a current to flow in the upper pole winding of the relay. The direction of this current in relationship to the lower pole current is such that a contact opening torque is produced on the disc. When the temperature of the protected apparatus is greater than the critical temperature, the resistance of the exploring coils is greater than the fixed resistors of the relay. The Wheatstone Bridge is unbalanced, and a current flows in the upper pole of the relay. The direction of this current in relationship to the lower pole current is such that a control closing torque is produced on the disc. When the temperature of the protected apparatus is the same as the critical temperature, all resistances of the Wheatstone Bridge are equal. As a result, current will not flow in the upper pole winding and torque will not be produced on the disc. The relay is calibrated at the factory for a specific value of operating temperature and current. The balance temperature is usually set to be 5 to 10 C below the desired tripping temperature. The closing torque of the Type CT relay is approximately proportional to the product of the current squared and the temperature difference from the balance point. With the rise of these values above the operating limits, the relay contact close with a rapidly increasing force. The limited travel of the disc permits a very short operating time when the operating limits are exceeded considerably. When the resistance of the leads from the exploring coils to the relay is known at the time the relay is manufactured, each of the two resistors of the bridge circuit is constructed with a resistance equal to that of the exploring coil at the balance temperature plus the resistance of one pair of leads. Since

TYPE CT RELAy --------------------------------'--I_. L_._4_1 -_s s_ 1_. 1_A Fig. 2. IMDICATIMG COMTACTOR SWITCH --- - UPPER POLE COILS FRONT VI V -LOWER POLE COIL CHASSIS OPERATED StWRTIMG SWITCH RED H.IVIOLE TEST SWITCtl CURREI'!T TEST JAC TERM I MAL 183All6 Internal Schematic ol the Type CT Relay In the Type FT21 Case 7 Terminal Relay lor use where Exploring Coil Lead Resistance is Known When Relay is Manufactured. the lead resistance is not affected by the temperature of the exploring coil, the effect of appreciable lead resistance is to reduce the degree of unbalance of the bridge at temperatures above or below the balance point. However, lead resistances usually are less than 0.5 ohm per pair, and the reduction in sensitivity would not be serious with lead resistances of 1.0 ohm. When the resistance of the leads from the exploring coils to the relay can not be determined accurately before the relay is manufactured, the CT relay can be used with internal connections as shown in Fig. 3. The upper pole winding (connected in the galvanometer circuit of the bridge) is connected to independent terminals, and three leads (instead of two) are required between the relay and each exploring coil. With this connection, the resistance of one lead is inserted in each exploring coil leg of the bridge, and the resistance of one lead is inserted in each relay resistor leg. Thus, the balance of the bridge is not affected by the lead resistance. However, the resistance of two le11;ds is inserted in the galvanometer circuit. The relay is rendered somewhat less sensitive by this, but with lead resistance of 0.5 ohm each the operating temperature at full load would be raised less than 2"C above the temperature for zero lead resistance. The necessity of using a total of six leads instead of four may be objectionable in some cases, however. hidicatimg COMTACTOR SWITCHocs;.--- - ---, Fig. 3. Trip Circuit FRONT VlfV UPPER POLE COILS CHASSIS OPERATED SHORTIMi> SWITCH REDHAhDLE TEST SWITCH CURRENT TEST JACk. 183All7 Internal Schematic of the Type CT Relay in th e Type FT21 Case ' 9-Termlnal Relay lor use Where Exploring Coil Lead Res istance Is Unknown When Relay is Manufactured, The main contacts will safely close 30 amperes at 250 volts d-e and the seal-in contacts of the indicating contactor switch will safely carry this current long enough to trip a circuit breaker. The indicating contactor switch has two taps that provide a pickup setting of 0.2 or 2 amperes. To change taps requires connecting the lead located in front of the tap block to the desired setting by means of a screw connection. Trip Circuit Constant Indicating Contactor Switch (ICS) 0.2 ampere tap 6.5 ohms d-e resistance 2.0 ampere tap 0. 15 ohms d-e resistance EXPLORING COl LS It is preferable to use exploring coils which are built into the apparatus to be protected at the time of manufacture as they can be placed in the winding slots or otherwise brought into proximity to the windings being protected close to the point of highest temperature rise. The physical design of these coils will vary with the individual apparatus, but exploring coils usually are copper, with a resistance of 10 ohms at 25 C. 3

TYPE CT RELAY I 2 3 -- - --- ---- ----l EC 49 8 '----- '---- --------------J 7-T ERMINAL RELAY FOR USE WHERE EXPLORING COIL LEAD RESISTANCE IS KNOWN WHEN RELAY IS MANUFACTURED Fig. 4. If a motor or generator has been built without exploring coils and it is desired to provide temperatureoverload protection by means of the type CT relay, a "Rope Coil may be fastened to the end connections of the windings..-----. 9-T ERMINAL RELAY FOR USE WHEN EXPLORING COIL LEAD RESISTANCE IS UNKNOWN WHEN RELAY IS MANUFACTURED EC NEG, _ DEVICE NUMBER CHART 49-TEMPERATURE OVERLOAD RELAY TYPE CT LP-LOWER POLE COILS UP-UPPER POLE COILS ICS-INDICATOR CONTACTOR SWITCH 52-pOWER CIRCUIT BREAKER TC- BREA KER TRIP COIL BREAKER AUXILIARY CONTACT EC-EXPLORING External Schematic of th e Type CT Temperature Overloacl Relay. Because of its location it can not indicate the winding temperature as accurately as a built-in exploring coil. loop or skein of wire approximately The "Rope Coil is a flat 10 feet long. Two strands of enameled copper wire are wound in parallel and four leads are brought out, providing the two exploring coil sides of the bridge in the one winding. The coil then is insulated with a tape winding and is varnish dipped and baked. It is sufficiently flexible to permit placing and tying it around the end connections of the winding. The panels INSTALLATION relays should be mounted on switchboard or their equivalent in a location free from dirt, moisture, excessive vibration, and heat. Mount the relay vertically by means of the four mounting holes on the flange for semi-flush mounting or by means of the rear mounting stud or studs for projec- 4 COIL l83a477 tion mounting. Either a mounting stud or the mounting screws may be utilized for grounding the relay. The electrical connections may be made directly to the terminals by means of screws for steel panel mounting or to the terminal studs furnished with the relay for thick panel mounting. The termi9-al studs may be easily removed or inserted by locking two nuts on the stud and then turning the proper nut with a wrench. 41-076. For detailed FT case information refer to I.L. ADJUSTMENTS AND MAINTENANCE All contacts should be periodically cleaned. A contact burnisher S#182A836H01 is recommended for this purpose. The use of abrasive material for cleaning contacts is not recommended, because of the danger of embedding small particles in the face of the soft silver and thus impairing the contact. The proper adjustments to insure corr ct operation of this relay have been made at the factory and should not be disturbed after receipt by the customer.

TYPE CTRELAY 1 _L._4_1_" 5_51_ 1A Fig. S.,- ('RO'JT VIEW) A I I ll LOAD RESISTOR 120V 60 CYC ;- ---,--L SUPPLY, -- 5 1-52 - NON-INDUCTIVE SLIDE RESISTORS ADJUSTABLE FROM 10 TO APPROX IS OHMS OR LESS SLIDE MUST HAVE NEGLIGIBLE CONTACT RESISTANCE Diagram of Test Connections for the Type CT Relay In Type FT21 Case. If the adjustments have been changed, the relay taken apart for repairs, or if it is desired to check the adjustments at regular maintenance periods, the instructions below should be followed. Operating Coil To check the operating coils, connect the relay per Fig. 5. and The relay should trip at "A" amperes "T" degrees C. as marked on its nameplate. The temperature may be represented by increasing the resistance of the exploring coil sides of the bridge by means of slide wire resistances, to the values corresponding as shown in the following table: Resistance T empetature Resistance Temperature 10.00 ohms 25 C. 12.89 100 10. 96 50 13.28 110 11.35 60 13. 66 120 11.73 70 14.05 130 12.12 80 14. 43 140 12.50 90 14.82 150 NOTE - This table applies only to copper wire coils having 10 ohms resistance at 25 C. Indicating Contactor Switch (ICS) Close the main relay contacts and pass sufficient d-e current through the trip circuit to close the contacts of the ICS. This value of current should not be greater than the particular ICS tap setting being used. The indicator target should drop freely. RENEWAL PARTS Repair work can be done most satisfactorily at the factory. However, interchangeable parts can be furnished to the customers who are equipped for,doing repair work. the complete nameplate data. When ordering parts, always give ENERGY REQUIREMENTS The 60 cycle burden of the relay on the current transformer is 15.0 volt-amperes at 5 amperes, 49 lag Power Factor. The continuous rating of the winding is 5 amperes ( 10 ohms exploring coil), and the one second rating 150 amperes, 60 cycles. 5

TYPE CTRELAY 6 I ' - 3 -- I f-g i\.\ PANEL LC>CA\\01-l \ SEN\"1 -l="lush MIG:. \ PROJ'ECT\CiN N\TG. --- TERMINAL AN D MCI.JNTINE,- L>E'TA.IL'S 2-IBSCRE.W IE> (FOR \HICK PAHEL USE -18 STUD) NOTE : ALL CIMENSIONS in \l-lcl-4ee> oi D-3'?. SCREW.. 1::: 7 -:) s.. b.. EL :ut:.vt { - r,:._._i'\._;. ::-:-_,R_ ::E'y! \-F JC:,\-1 "T-. / -'--- - PAN EL CR\LLING OR CUT0UT :::-0R PROJ"E.CTION MTG. ('F kont VII:W) * Fig, 6. Outline and Drilling Plan for the Type CT Relay in the Type FT21 Case. i 57-D-7901

TYPE CT RELAY---------------------------------------------------------- _L._4 1 -s s1 1A 1 j: Fig. 7. Type CT Relay 7 - Balancing Resistor. 2 -Moving Contact Assembly. 3- Stationary Contact Assembly. 4 - In clicating C ontactor Switch (ICS). 7

WESTINGHOUS E EL ECTRIC CORPORATION RELAY DEPARTMENT NEWARK, N. J. Printed in U. S. A.