cor Long Run Experience

Vistop TM isolating switches 63 to 160A

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Moulded Case Circuit Breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Motorized switch-disconnectors OTM 40 to 125 Amperes

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX earth leakage DPX 3 -I earth leakage

3 - Protection components Motor circuit-breakers

500V / V /

DPX Magnetic only

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Moulded case circuit breakers

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DPX 1600 Electronic release

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DRX 250 B/N/H Circuit breaker (not adjustable)

K50H004UP cam changeover switch - 4-pole A - screw mounting

DPX moulded case circuit breakers

K30H001YP cam star-delta switch - 3-pole A - screw mounting

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DRX 100 B/N/H Circuit breaker (not adjustable)

25A 25A 32A 40A 40A 63A 63A 80A

DRX 125 Circuit breaker (not adjustable)

DPX 630 Electronic release

Thermal magnetic and trip-free switches


DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Changeover & Bypass Sw it ches

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MANUALLY OPERATED CHANGEOVER SWITCHES

01 Spectra Plus - Introduction

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection components

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Cylindrical fuse-link

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Motor Protection Circuit Breakers 3VU13 and 3VU16

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Special Purpose Fuses

DPX Electronic + earth leakage

Miniature circuit-breaker (MCB) SH200M Series

AF40... AF96 3-pole contactors Technical data

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Phase + Neutral, neutral on right side

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Varius SUMMARY OF MODELS

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Phase + Neutral, neutral on left side

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

ROTARY CAM SWITCHES CAM SERIES. User Manual - Issue 1.1

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

LOAD BREAK SWITCHES A TECHNICAL DATA FOR KU, KUE, VKA AND EVA SERIES

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Modular contactors and relays

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Fuse switch-disconnectors

Switches disconnectors with fuse-holders. XNF series TF series

D509E. Manual Motor - Starters

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Euroload Changeover Switch

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Short-circuit current limiter S800-SCL-SR

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Varius SUMMARY OF MODELS

Fuse switch-disconnectors

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

MS25, MST25, MS20, MST20

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MULTIVERT 1000A Main Incomer, 690VAC

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Wall mounted switchgear

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

Series L9 UL489 Miniature Circuit Breakers

SFS-UFS Single Foot Switches

Low Voltage Switches. Switches Motorized change-over switches OTM _C

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

Varius SUMMARY OF MODELS

Transcription:

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250 D N S V N S V Current range (A) 20, 25, 32, 40, 50, 63, 80, 100 100, 125, 160, 200, 250 32, 40, 50, 63, 100, 125, 160, 200, 250 320, 400 320, 400 500, 630 1250 Poles 2 / 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 Impulse withstand voltage Uimp (kv) 6 6 8 8 8 8 8 Rated Operational Voltage Ue (V) (MAX) 600 600 690 690 690 690 690 Rated Insulation Voltage Ui (V) 690 690 800 800 800 800 800 800 800 800 800 Utilisation Category A A A A A A A Standard IEC60947-2, EN60947-2 & IS/IEC60947-2 400 / 415V 25 36 50 36 50 70 80 36 50 36 50 70 100 36 50 70 100 50 70 100 Rated Short Circuit Breaking Capacity Icu (ka) Ics as % Icu 480V 690V 400 / 415V 480 / 500V 10-100% 100% 10-50% 50% 10-50% 50% 25 10 100% 100% 36 15 100% 100% 42 20 100% 100% 65 36 100% 100% 25 37 8 5 100% 100% 25 8 100% 100% 36 15 100% 100% 42 20 100% 100% 65 50 100% 100% 25 8 100% 100% 36 10 100% 100% 42 15 100% 100% 65 50 100% 100% 25 10 100% 100% 36 18 100% 100% 65 50 100% 100% 690V - - - 100% 100% 100% 50% 100% 100% 100% 100% 50% 100% 100% 100% 50% 100% 100% 50% Life span Mechanical Electrical @1.0 In 30000 4000 30000 4000 10000 3000 25000 10000 25000 10000* 10000 4000 15000 4000 15000 4000* 15000 4000 15000 4000* 8000 750 15000 750* Operating Frequency (Hz) Total Opening Time Finger-proof Terminals Suitable for Isolation IP class Pollution degree Load Line Bias Ambient Temperature Storage Temperature Mounting Positions in Vertical Plane 50 / 60 <10msec Yes Yes IP40 III No o o -5 C to 55 C o o -35 C to 70 C o Vertical and 90 in both directions <20msec Dimensions (WxDxH) mm 3-Pole 4-Pole 75 x 60 x 130 100 x 60 x 130 105 x 60 x 165 140 x 60 x 165 105 x 96 x 179 140 x 96 x 179 140 x 111 x 205 184 x 111 x 205 140 x 111.5 x 266 183.5 x 111.5 x 266 140 x 111.5 x 266 183.5 x 111.5 x 266 210 x 143 x 370 278 x 143 x 370 Weight (kg) (3 Pole) 0.8 / 1.1 0.73 / 1 2.5 / 3.3 2.5 / 3.3 4.0 / 5.0 5.5 / 7.2 5.8 / 7.4 6 / 7.8 6.3 / 8 15 / 16 Terminal Capacity Standard With Spreaders 2 Cables with Lug (mm ) Link (mm) 2 Cables with Lug (mm ) Link (mm) 35 17 50 22 120 26 185 35 95 25 185 35 185 32 2*240 2*40 120 27 2*240 2*40-2*40 2*300 2*60 *at 415V DN2-1500 @ 690V DN3-1000 @ 690V Note: Any two internal accessories can be mounted at a time Separate earth fault module required for earth fault protection using TM releases Terminal shroud mandatory for H and V versions Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity

73 74 Technical Specification Frame 1 Frame 2 Frame 3 Frame 4 Frame 5 Frame 6 Rating (A) Unit 63A 100A 125A 160A 200A 250A 315A 400A 630A 630A 800A 1000A 1250A 1600A 2000A Reference Standards IS / IEC 60947-3, EN 60947-3 Type designation CO1-63 CO1-100 CO2-125 CO2-160 CO2-200 CO3-250 CO3-315 CO4-400 CO4-630 CO5-630 CO5-800 CO5-1000 CO6-1250 CO6-1600 CO6-2000 No. of Poles 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole 4 Pole Rated operational voltage (U ) e (V) 415 415 415 415 415 415 415 415 415 415 415 415 415 415 415 Rated frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 Rated impulse withstand voltage (U ) imp (kv) 8 8 12 12 12 12 12 12 12 12 12 12 12 12 12 Pollution degree 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 0 Conventional free air thermal current, lth at 40 C Conventional enclosed thermal current, l 0 the at 40 C (A) (A) 63 63 100 100 125 125 160 160 200 200 250 250 315 315 400 400 630 630 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 # # Rated operational current, l e AC-21A / AC-22A / AC-23A (A) 63 100 125 160 200 250 315 400 630 630 800 1000 1250 # 1600 /1250 # 2000 /1250 Rated operational power for AC-23A* (kw) 37 50 65 85 100 132 160 225 315 315 400 450 710 710 710 Rated breaking capacity for AC-23A (A) 504 800 1000 1280 1600 2000 2520 3200 5040 5040 6400 8000 10000 10000 10000 Rated making capacity for AC-23A (A) 630 1000 1250 1600 2000 2500 3150 4000 6300 6300 8000 10000 12500 12500 12500 Short time withstand, l cw 1 sec 0.2 sec (ka rms) (ka rms) 4 7 5 10 8 18 8 18 10 18 16 28 18 28 22 35 26 35 35 70 50 85 50 85 50 85 50 85 50 85 Short-circuit making capacity, l cm (ka peak) 5.9 7.7 14 14 17 32 36 46 55 73.5 105 105 105 105 105 Endurance (category A) Mechanical Electrical (O-I-O-II-O cycle) (O-I-O-II-O cycle) 20000 3000 20000 3000 16000 2000 16000 2000 16000 2000 16000 2000 16000 2000 10000 2000 10000 2000 10000 2000 10000 1000 10000 1000 10000 1000 10000 1000 10000 500 Type and size of fuse Rated fused short-circuit current at 415 V, 50/60 Hz DIN/Cylin Motorised Kit Rated control voltage Control voltage range DIN/Cylin (ka rms) (V) (%) 14 x 51 80 NA 000 100 00 100 240 V ac 85% - 110% 00 100 1 1 100 100 240 V ac 85% - 110% 2 100 240 V ac 85% - 110% 3 3 NA 100 100 NA NA NA 240 V ac 85% - 110% 240 V ac 85% - 110% NA Pollution degree 3 3 3 3 3 Operating temperature ( C) -5 to + 55-5 to + 55-5 to + 55-5 to + 55-5 to + 55 Ingress protection (from front) IP30 IP30 IP30 IP30 IP30 Max. current at 240 V ac Operating time (min) O-I / I-O I-II / II-I (A) (sec) (sec) 2 0.5 1.4 2 0.6 1.4 2 0.7 1.4 2 0.7 1.4 2 0.7 1.4 Black out time Control glass fuse current rating Termination Capacity (240 V ac) (sec) (A) 1.4 1.25 1.4 1 1.4 1.25 1.4 1.25 1.4 1.25 Maximum Al. cable with lug (sq mm) 25 25 95 95 150 185 240 2 x 300 2 x 300 2 x 400 2 x 400 2 x 400 2 x 12 x 63 4 x 8 x 50 3 x 10 x 100 Maximum link width (mm) 16 16 30 30 30 40 40 50 50 60 60 60 80 80 100 Maximum link thickness (mm) 2 2.5 5 5 6 8 8 8 2 x 8 2 x 10 2 x 10 2 x 10 3 x 12 3 x 12 3 x 12 Termination tightening torque (N-m) 4.5 4.5 10 10 20 20 20 27 27 35 35 35 55 55 55 Operating torque center / side operating (N-m) 4.5 4.5 10 / 13 10 / 13 10 / 13 20 / 25 20 / 25 28 / 32 28 / 32 30 / 40 30 / 40 30 / 40 55 55 55 Weight (without accessories) (Kg) 2 2.5 4 4 4.5 6.5 7 14 14.5 20 22 22 52 57 75 *These values are for 4 pole squirrel cage induction motors and are provided only for guidance and may vary as per the motor manufacturer # Rated operational current, l e AC-21A / AC-22A Type cylindrical fuse