Muto Electro Magnetic Lock (Elock MEM4400) Installation instructions / Wiring manual

Similar documents
Headers - 4-1/8, 4-1/2, 6. with PT21 and Shear lock for single or double doors. Installation instructions

Floating Headers - 4-1/8, 4-1/2, 6. with RTS88 and PT21 for double doors ONLY. Installation instructions

DORMA INTERIOR. DORMA PURE FAMELESS SLIDING Glass Wall Systems

TENSOR. Double-acting hinge for tempered glass doors. Interior glass systems. Equia nestotatus enis 2015

Universal & EA patch fittings

ESA II. I - Revive Slider Conversion Kit. Installation instructions

Installation Instructions for Series 3100V Low Level Indicator

Electro-Mechanical Swing Operator. Table of Contents

MUTO Premium & Comfort

Pre-Installation Instructions

MUTO Comfort for demanding system solutions. MUTO The compact, flexible manual sliding door system

SAFETY AND OPERATING MANUAL. Lithium-Ion cordless hammer drill WX372 WX372.1 WX372.9

Operating Instructions Type MPT 53

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

INSTALLATION 8310/8320

UNIVERSAL. products will be phased out by UNIVERSAL. Technical brochure Patch fittings for toughened glass assemblies

Power Supplies DORMA PS

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

MULTIFUNCTION MANUAL SLIDING DOOR SYSTEM

ELECTROMAGNETIC LOCKS

Auxiliary Status Switch Kit

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Electrohydraulic Powered Systems

RS 120 & DRS 120. Hardware for manual sliding door systems. Equia nestotatus enis 2015

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Auto Gate System. General Description. Features EL-888A. elock EL-888A is an electro-mechanical complete system for. EL-888A (Auto gate)

2965 Magnetic Shear Lock Installation Instructions

2904 Power Supply Installation Instructions I-EA00041

Installation and Operation Instructions 10/04/13

Plug and Play Kit Installation and Wiring (Non-Combo and Combo)

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

HANDLING MECHANICAL INSTALLATION

S-Drive Performance Trainer

Installation, Operating and Maintenance Instructions Retractable Door / Art.-Nr.:

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting

Surface Applied Door Closer and Coordinator System DORMA GSR

Installation Instructions

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ZIP LIGHT LED LUMINAIRE

INSTALLATION INSTRUCTIONS FOR THE ASEPT.1X

E-SL 450BD Series INSTRUCTION MANUAL WARNING USER DRIVEN MANUAL*

Installation Bulletin Number: IB-5111 Rev: A Date: Feb 2014 Affected Parts: K

Preventive Maintenance for Pail Melters

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Air terminal devices

HEAVY DUTY TROLLEY JACK. Operation Manual

TS93 EMF T/PT/TDE. Surface applied door closer

Assembly and Maintenance Manual Type ASNU

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation Instructions

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

HIGH SPEED SLIDING GATE OPENER

COOKSON OWNER'S MANUAL

MUnDUs premium MUnDUs Comfort

AIRLIFT INSTALL GUIDE. Powerglide Air Opener. Horizontal Mount AIRLIFT DOORS, INC. TOLL FREE:

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

S (8.0) (5.15).551 (14.0) .275 (7.0) S100

Operating Instructions Pedestrian Turnstile Type MPT 33

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

4040XPT Series Door controls

FREQUENCY INVERTER INSTALLATION & USER GUIDE

Elvoron Home Elevator

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

UB-2PN Universal 2 Pneumatic Button

RAMSET

ELVORON HOME ELEVATOR

Creating An Accessible World ELVORON CPL.

BEL-20N CHAIR IMPORTANT

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Opticom TM Model 795H-INT with Bracket for Deck or Inside Windshield Mounting

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Magnetic Alarm Switches

U1500. Surface Applied Door Closers

Pre-Installation Instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SECURITY DOOR CONTROLS

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

Fitting Instructions. Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents

TOYOTA CAMRY BODY SIDE MOLDING Installation Preparation

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Operations and maintenance manual

Hunter Automatics HA-8. Installation Manual

SAFETY

SLIDING DOOR SYSTEM_ S42 TECHNICAL BOOK. System description Accessories

SMP3CTX Series Power Supply/Charger

E-200 Module Service Kit

Automatic Swing Door Operator DFA 127 IN (Inverse) Operating instructions E

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

Assembly and Maintenance Manual Type AS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Installing an H-200 Integral Right-Angle Module

Transcription:

Muto Electro Magnetic Lock (Elock MEM4400) Installation instructions / Wiring manual 936033 05-2018 EN

Table of Contents Table of contents 1 Technical specifications 3 1.1 Overview 3 1.1.1 General information 3 1.1.2 Intended use 3 1.1.3 Glass requirements and fittings 3 1.1.4 Safety instructions 3 1.1.5 Symbols used - Safety/Installation 3 1.1.6 Maintenance, care, repair 3 1.1.7 Disposal 3 1.2 Specifications - technical data 4 1.3 Dimensions 4 2 Installation instructions 4 2.1 Overall 4 2.2 Secure armature bracket to rollers 5 2.3 Secure mag lock to wall/door frame structure 6 3 Change handing of mag lock 6 3.1 Change handing 6 4 Wiring the circuit board 7 4.1 Wiring diagram 7 2 MUTO Premium 936033 05-2018

Technical specifications 1 Technical specifications 1.1 Overview These instructions are for installation of MUTO PREMIUM sliding door system XL150 / XL80 for the following mounting and style versions: 1. Wall or Ceiling mount 1.1.1 General information dormakaba requires use of tempered monolithic or tempered laminated glass. dormakaba glass hardware is not suitable for application in rooms where chemicals (e.g. chlorine) are used as indoor swimming pools, saunas or salt-water pools. Never move sliding panels faster than walking speed and always stop the door manually before it reaches end position. Do not slide doors with excessive force. Install limiting stop to prevent door from opening too far. 1.1.2 Intended use For sliding door in dry indoor areas only For manual slowly opening and closing only 1.1.3 Glass requirements and fittings The substructure/wall must be able to bear permanent loads and be level (max. tolerance: 1/16 [2] per 39 [1m]). Fasteners must be sufficiently dimensioned for the substructure/wall and weight of the door. When adjusting glass components, always stick to the required clearance for the respective hardware. Adjust clearance so glass does not come in contact with any hard surfaces such as glass, metal or concrete. Do not use excessive force when installing the glass (avoid over tightening screws). 1.1.4 Safety instructions Installation requires two people. Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware. Due to crushing hazards and possible injury caused by breakage of glass during mounting, corresponding protective clothing (especially gloves and protective goggles) is required. Work on electrical equipment and 240/120 VAC wiring installation must be performed ONLY by qualified personnel. 1.1.5 Symbols used - Safety/Installation CAUTION Mounting components must meet the requirements of substructure/wall and door weight. Please read the technical information for fittings. WARNING Risk of breaking glass. When installing the door, support the door panel with a block of wood or similar object. WARNING Electric shock warning! TIPS AND RECOMMENDATIONS Information note CLOSING EDGE 1.1.6 Maintenance, care, repair Immediately replace damaged parts. Always use original dormakaba parts. Clean clamping area with alcohol-based standard commercial cleaning agent before mounting the glass hardware. Use a damp clothe for occasional cleaning, especially the track. Always use silicone - and oil-free cleaners (e.g. acetone). Check glass hardware at regular intervals for proper positioning and smooth operation and correct adjustment. High traffic door systems require inspection by properly qualified staff (specialized companies or installation firms.) 1.1.7 Disposal Disposal in accordance with local, state and national regulations. MUTO Premium 936033 05-2018 3

Technical specifications 1.2 Specifications - technical data Wall or Ceiling mount Door leaf weight lbs [kg] * Single Door XL150/80 330lbs [ 150] * Including weight of auxiliary hardware. Single Door XL120 264lbs [ 120] 1.3 Dimensions Fig. 1 NOT TO SCALE For all MUTO XL150/80 less DM, only applications For MUTO XL120 SC only applications For MUTO XL150 DM only applications 2 [48] 2-11/16 [68] 3-1/2 [88] 2 Installation instructions 2.1 Overall Fig. 2 1.2 1.1 1.3 1.4 1.1 MEM4400 mag lock 1.2 Circuit board 1.3 Armature 1.4 Armature bracket 4 MUTO Premium 936033 05-2018

Armature bracket 2.2 Secure armature bracket to rollers: to glass or wood doors Fig. 3 Glass cut out: pre-fab Legend Closing edge of door Glass panel Wood Door Adaptor cut out: TO BE CUT IN FIELD 1-1/16 [27] Wood door adaptor Armature Wood door NOTE: Ensure armature and bracket align with mag lock, once installed. Use any of the 3 screw slots in bracket to mount accordingly. Mag lock Leading roller carrier Armature bracket Armature bracket screw slots 2.2.1 Glass door: Ensure glass cut out is toward the closing side of the moving panel. 2.2.2 Wood door: Cut 1-1/16 [27] from leading end of wood door adaptor. 2.2.3 Secure armature bracket to leading roller carrier. Use included fasteners. MUTO Premium 936033 05-2018 5

Mag lock 2.3 Secure mag lock to wall/door frame structure Fig. 4 Mag lock Mag lock Armature 5/8 [15.4] 23/32 [18.4] (Blocking by others) Mag lock MUTO Track 2.3.1 Secure mag lock onto appropriate wall/door frame structure, as required per your application. 2.3.2 Use appropriate fasteners (not included). Legend Closing edge of door 3 Change handing of mag lock 3.1 Change handing Fig. 5 3.1.1 Rotate armature bracket in correct direction depending upon your application. 6 MUTO Premium 936033 05-2018

4 Wiring the circuit board 4.1 Wiring diagram Fig. 6 Wiring Circuit board MEM4400 mag lock Early Warning Sensor C NO NC 30 Vdc 0.2A max (Dry trigger) Customer Lock release 12-24 Vdc 12Vdc, 0.28A (Input power) 24 Vdc 0.14A NO NC C EXIT DSS - + Relay2 Alarm relay Relay1 TIMER L+ L- RED BLK Alarm panel contact C NO NC MAG Lock - + BLK RED By customer Delay time increase on CW rotation 0-30 s (optional Early Warning Timer) MEM Lock Wirng to PCB MEM Power Input, 12VDC EW Sensor Output (EW = Early Warning) PCB Connection Power Input Wire color Black (-) Red (+) Brown (C) White (NC) Grey (NO) Terminal Designation - + Connects to Power Input Connects to DSS if used +12 VDC, 1A maximum Exit Input EXIT Connects to customer dry trigger DSS Sensor Input DSS Use jumper or Early Warning Sensor brown and white wires MEM Lock Power Output Alarm Relay Output 30 VDC, 2A max. 120 VAC, 1A max. Alarm Relay Timer Input L- (BLK) L+ (RED) NO NC C TIMER Connect to Mag Lock Use to trigger auxiliary LED, siren, alarm panel, etc. 0 to 30 sec. delay timer (EW) Contact closes to activate Alarm Relay Output Use to trigger alarm panel or other. MUTO Premium 936033 05-2018 7

www.dormakaba.com dormakaba USA Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 USA T: 717-336-3881 F: 717-336-2106