Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Similar documents
MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

SAVE THESE INSTRUCTIONS

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

CFP-LED Contractor Select Flat Panel. Installation Instructions

INSTALLATION & MAINTENANCE MANUAL HBL

LED SMD CANOPY FLAT FIXTURE

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

Installation Instructions: Eco Linear High Bay

General Installation Instructions LED

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

MaxLite LED Linear HighBay Fixtures

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

NOVO LIGHTED MIRROR. Installation Instructions

Installation Instructions

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Installation Instruction ALG Series LED Area Light Version: 3.1

Operating Instructions

Installation Instructions

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

High Bay Luminaire Series

MaxLite StaxMax LED Flood Lights

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

HBDBM High Bay Series

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

LED CANOPY with j-box

COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - SUSPENDED

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Electric Vehicle Charging Station

Circa Ambient Interior Luminaire

INSTRUCTION MANUAL SINKER. By HAY

COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - RECESSED MOUNT

EMERY SKY SUSPENDED LED LUMINAIRE

Installation Guide DO NOT CUT WIRES

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Sky FactoryTM. Classic w/ EcoSlim Electrical Instructions (HLG) Installation Instruction includes:


MaxLite LED UTILITY WRAP FIXTURES

Installation Instruction

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

LED IMPORTANT SAFETY INSTRUCTIONS

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

HP-2 / HP-6 Direct Installation Instructions Overview

NT-300 Series Single Circuit Track System & Accessories

Installation Instructions

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

SAVE THESE INSTRUCTIONS

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

LED IMPORTANT SAFETY INSTRUCTIONS

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Specialty Finishes. AIR by 3M Installation Guide 7 ft. Pendant, Specialty Finishes. Installation Guide

AIR by 3M Luminaire Installation Guide 3 ft. Pendant. Standard and Specialty Finishes A003-XX-3K-XX-XX A003-XX-4K-XX-XX. Installation Guide

Installation Instructions

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

MOUNTING SYSTEMS SPECIFICATIONS

Installation Manual. Rev

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

MEDMASTER EXTERNAL POWER SUPPLY

Installation Instructions BLTR and 2BLTR Relight Assembly

BLAZE 12V LED TAPE LIGHT

SAVE THESE INSTRUCTIONS

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

IMPORTANT SAFETY INSTRUCTIONS

When using electrical equipment, basic safety precautions should always be followed including the following:

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

TECTONIC LED CORP. ISO

Installation Instructions

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

LED 2/3/4ft T8 Tube 120V

HPNLS-HO. Installation Manual

LED IMPORTANT SAFETY INSTRUCTIONS

Compact Sheet-steel Emergency Light Fitting Series 6118/1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Installation Instructions: Eco SpunBay LED High Bays

BMRX Series ROTARY LEVEL CONTROL

HBC-20 - LED HIGH BAY

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

GLASS ACT SINGLE RPD14 SUSPENDED, WALL, SURFACE

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

My Reserve 500 Install Guide

LED IMPORTANT SAFETY INSTRUCTIONS

BATTERY SAVER LOW RIPPLE HO

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Installation Instructions

Transcription:

GENERAL REMARKS ON SAFETY: Read all of these instructions before installing fixtures. Keep all of the instructions for future reference. Turn off power before installing fixture. Installation is to be performed by a qualified electrician only. All installations are to conform to the standards of National Electrical Code as well as all local jurisdictional codes and regulations. Any modification of the luminaire will void any and all written or implied warranties. Do not open the luminaire this will void the IP rating The manufacturer accepts no responsibility for damage to persons of property arising through improper use or installation. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED Technical data: Frame 5 parts aluminum profile, polished, with integrated acrylic glass cover. Dimension Fixture technicalunit Weight Weight Ø 61 inch/1550 mm 4.3 lbs/11 kg 11 lbs/5 kg Package1 BOM quantity Package 1: Pendant light Light fixture rings 1, preassembled, 5 parts including 4 part assembling aid Transparent supply line, pre assembled and attached to the rings 3 3 units Supply line to technical unit/canopy Package : technical unit, canopy Canopy 4 including part cover 5 and preassembled steel cables 5 m long 6 7/14 units Technical unit 7 Gloves, white pairs Assembly instruction Optional: Interface dimmer 110 V Package 5 1 4 3 6 7 1

Delivery contains packages Unpack the light fixture and check the bill of material. Use enclosed cloth gloves to prevent soling of polished frame, screws and acrylic. 1. Mark anchor positions on the wall Mark anchor position of your canopy on the ceiling according to drilling template, drill the anchor points with Ø 6mm (1/4 ) anchors. Alternatively, mount to canopy octagonal jbox.. Installation of canopy Attach canopy to jbox or ceiling. Pull the power supply cable through the 1 1/4 hole and make connections.

. Fit the canopy Mark the mounting points of the canopy 4. Pre drill the mounting points for the canopy into the ceiling, using a Ø 1/4 inches/6mm drill. Then insert the anchors and fasten with 4 screws. Please ensure the load capacity of the ceiling is sufficient. 3. Alignment of light fixture Align the cross shaped plastic assembling aid so that it is parallel to the cables in the canopy 4. 4. Mounting of the light fixture First, remove both upper parts of the plastic assembling aid by cutting the white cable straps. Please note: Please do not yet remove the lower assembling aids which are attached to the light fixture with black cable straps. 3

4.1 Fastening the cord suspension Insert the lower ends of the steel cables into the cable grippers which are pre assembled and mounted on the light fixture. In order to do this, completely open the respective lock nut. When mounting the 7/14 fastening cables to the light fixture rings, work from the outside towards the inside. The alignment of the light fixture according to the mounted ceiling plate is important here. The light fixture ring can be moved up by applying slight pressure to the spring loaded inlet of the cable hold. As soon as the cable gripper is fully loaded, it locks and cannot slide in any direction. 4. Alignment of the light fixture For preliminary alignment, lift light fixture and tighten the steel cables, one after the other. Then, align the light fixture horizontally with the aid of a level. In order to achieve this, it is necessary to re adjust the cable gripper of the respective rings several times. Once the light fixture has been aligned correctly, (the light fixture is still fastened to the assembling aid) tightly screw in the lock nuts of the cable grippers by hand and tighten them Hand Tight. Note: The steel cable brackets are just for indoor use. The nozzle of the steel cable bracket must show noticeable spring loaded pressure. To ensure the full load capacity the cables shouldn t be greasy or rusty. The steel cable brackets are just for use of supplied steel cables at static load. The exit angle of the steel cable at the nozzle should on no account be more than 10. 4

4.3 Connect the light fixture cables Run the 3 light fixture cables alongside the respective steel cable up to the ceiling plate and fasten them to the cable with the pre assembled cable clips. Connect the light fixture cable to the canopy according to the connection diagram. Afterwards, mount both covers to the ceiling plate. Now fully remove the assembling aid. 5

5. Installation of TU (technical unit) The TU has to be mounted vertical to guarantee air circulation. Connect the power supply line to the TU. Please note the pole labeling when connecting the supply line between TU and light fixture. The distance between TU and light fixture should not be more than 30 feet. 5.1 Connection template The connection has to be done in accordance to the terminal assignment. This varies depending on the diameter and power supply(s). Technical unit / Canopy TU Push terminal PE L N 10 77V 50/60 Hz External supply line Canopy 6

1.. 3. 4. 5. 6. 7. 8. Wiring Key Points LEDs shall be wired in parallel as shown in wiring diagram. CAUTION: incorrect wiring may damage LEDs. Wire shall be #18AWG stranded minimum. Large gauge wire shall be used to limit voltage drop in order to maintain the proper operating voltage. Take every precaution to avoid interferance from other electrical circuits and equipment. Dimming circuits are more sensitive to voltage drop and electrical interference from other electrical sources. Isolating LED wiring by dedicated circuit for each control zone is recommended. prior to energizing the circuit. All Class II power cable remote wiring and driver enclosures by others. LED s can be permanently damaged if these points are not followed ground (green) Neutral Hot TYPICAL DIAGRAM Fixtures wired in PARALLEL. Check driver s rated wattage AC input 4VDC Constant Voltage Driver DC output Conductor colors may vary. LED information below. LED LED Wire gauge Maximum wiring distance* Load per driver 48W 7W 96W #18AWG 37' 5' 18' #16AWG 59' 39' 9' #14AWG 95' 63' 47' #1AWG 151' 101' 75' #10AWG 41' 160' 10' * Voltage drop guide for 4VDC. Actual Voltage drop to be calculated by installer. 7