Development, innovations and transformer solutions

Similar documents
Multifunctional transformers and innovative solutions for contingency planning

Shunt reactors Proven history for future success

ABB Transformer On Site Repair. ABB Power Products Division. Product Group Transformer Service

Power and Distribution Transformers

Power Voltage Transformers for Air Insulated Substations

Small wonder. Station service voltage transformers for small power requirements

TWO TECHNOLOGIES, ONE SOLUTION

Stray Losses in Power Transformers

SLIM Transformer. Compact transformer solutions for new applications. Your partner in energy solutions

Large Power Transformers

Diversifying into Marine Energy. ABB March 2015

ABB Wind Power Solution

High Voltage Pad-mount Transformer

Dryformer. a new type of oil-free power transformer with low environmental impact

Electric buses Solutions portfolio

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Service and Rehabilitation Electrical Power Systems

SIGENTICS HV Series S-modyn

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

ABB Next Level Big shift in power attractive opportunities

Distribution transformers Efficiency over life-cycle

Karl Elfstadius, ABB Smart Grid Program Mmanager / SMART GRID TAIWAN, Smart Grid Overview. ABB SG_Presentation_V4.

Renewables induce a paradigm shift in power systems, is energy storage the holy grail?

Increase transformer reliability and availability: From Condition Assessment to Site Repair

Innovative solutions for integration of distributed renewable generation

Efacec. OUR VISION We provide solutions for a sustainable world in the new Energy Era

NEXT STEP B) SAFETY :

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

TGK Prefabricated Substation Technical Data

ABB Wind Care Service Offering

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Innovative Transformer Solutions

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Power From Shore: An introduction to HVDC Light Offshore

Site Services. Asset Management for Modern Networks

ABB FACTS Customer Service. FACTS Care Upgrades

Christian Ohler, ABB Switzerland Corporate Research Physics of Electric Power Systems. ABB Group August 1, 2012 Slide 1

ABB Transformers TriDry transformers Compact Efficient Safe. ABB Group January 5, 2012 Slide 1

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Transformer Technology Seminar HV Collector (Power) Transformers

TECHNICAL STRATEGIC CHOICE: POWER ELECTRONIC SYSTEMS AND APPLICATIONS

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

GAS INSULATED VOLTAGE TRANSFORMERS.

Mining Electrical Maintenance and Safety Association Clearwater Florida June Draglines AC Drive Applications

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Increase transformer reliability and availability: From Condition Assessment to Site Repair

Live-line transmission lines upgrade projects. First-in-Africa project

About TECO-Westinghouse

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Reliable, economical and safe siemens.com/rail-electrification

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

Power+ CLASSIC. 20/30 kva, 3x208 Vac

What can HVDC Light do for you it s time to connect Applications Key Components

Medium voltage drive for single or multimotor applications, 3 27 MW

ABB. Replacement Components

KONČAR Group. Research and Development

Variable-speed drive solutions: Less current, less noise, less costs.

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

CMU Electricity Conference, 9th March 2011

SINAMICS GM150 IGCT version

Microgrid solutions Delivering resilient power anywhere at any time

Power & Distribution Transformers

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

HIGH POWER RECTIFIER SYSTEMS

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

ABB Brasil. Power Transformers: Life Cycle and Operational Cost Optimization Conventional, Wind and Solar Applications. Power Products Division

Getting Smart Evolution to the Smart Grid April 2008

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Feasibility of Electric Propulsion for Semi-submersible Heavy Lift Vessels

ABB Brasil. Power Transformers: Life Cycle and Operational Cost Optimization Conventional, Wind and Solar Applications

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

The Status of Energy Storage Renewable Energy Depends on It. Pedro C. Elizondo Flex Energy Orlando, FL July 21, 2016

60 MW GE LM6000 PC Gas Turbine Power Plant

Offshore Wind Connections HVDC for Offshore Grids

Refurbishment & Upgrade of the Celilo HVdc Converter Station

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Building Collaboration Between East African Nations via Transmission Interconnectors

Switchgear and Distribution Systems for Engineers and Technicians

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

The modular energy storage system for a reliable power supply SIESTORAGE

Retrofitting unlocks potential

Life cycle services for protection and control relays Full support from start to finish

ABB solar inverters Product portfolio

Inspection Testing Repair

C. System Design and Performance Requirements

ABB Transformadores para aplicaciones solares y eolicas

successful integration of distributed generation in rural areas

What is Smart Grid? R.W. Beck Inc.

Electrical Machine Service. Overhaul, Conditioning, On-Site Service and Diagnostics. Excellent Technology, Efficiency and Quality

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

Liquid-filled power transformers

Power IT Compact Secondary Substations, CSS. Substations

NXPLUS C Single busbar. Maintenance-free for lifetime

The Smart Way. HVDC PLUS One Step Ahead. Answers for energy.

Transcription:

ICREPQ 07 Seville Miguel Oliva ABB Development, innovations and transformer solutions ABB Group -1- M.Oliva - Mar-07

Transformer Development, Innovations and Solutions ABB Group -2- Energy is precious. Energy conservation and reliability of supply are actual topics these days. Efficient and environmentally sound operation of power plants, distribution networks and industrial processes. Reliable systems for cost-effective and secure power supply The classical objective triangle for power supply consisting of economy, reliability and environmental impact. Innovations for utilities and industry. To use the existing operating resources to maximum effect, and thus ensure secure returns on investment.

Transformer Development, Innovations and Solutions Transformers are one of the most important and costly components and the critical nodes in the electricity networks. ABB Group -3- Utilities have to use their existing equipment more efficiently ensuring high reliability and an adequate level of quality in the service provided.

Transformer Development, Innovations and Solutions Energy efficiency, environmental care, reliability and secure supply of electricity. Innovation and development: Efficiency: Reduction of losses. Noise level reduction. Dry type transformers of higher voltages. ABB Group -4- Transformer solutions: Polytransformers and universal GSU s. On field repair and upgrading. HV testing on site.

Distribution Transformers ABB Group -5-

Power Transformers ABB Group -6-

Transformer Innovation and Development Cooling system - Cooling systems - Cooling design Mechanical design - Design/materials - Manufacturing - Short circuit strength Insulation system - 800 kv HVDC - Safe Insulation - Diagnostics - Processing Acoustic - Noise - Higher requirements and regulations. Core & magnetics - Core optimization - Magnetic materials E&M modelling - Hf transient sim & network interaction - Losses ABB Group -7- Reduction in losses. Noise level reduction. Dry type transformers of higher voltages.

Efficiency: Reduction of Losses No load losses: Different material grades. RGO: Regular grain oriented. HIB: Highly oriented High permeability. DR: Domain Refined (Laser scribed). ABB Group -8-

Efficiency: Reduction of Losses Load losses reduction: The use of 3D magnetic field calculation tools allow to reduce load losses. Circulating current losses: Optimum location of transpositions. Stray losses: By an adequate loaction and dimensioning of magnetic shielding. ABB Group -9-

Efficiency: Reduction of Losses Use of 3D magnetic field calculation tools to reduce Load losses: 800 Load Losses (kw) 400/230kV B450MVA 750 kw 700 ABB Group -10-650 63056 63081 63128 63136 63162 63163 Serial Number

Efficiency: Reduction of Losses Use of 3D magnetic field calculation tools to reduce Load losses: 800 Load Losses (kw) 400/230kV B450MVA 750 kw 778.5 kw (Avg) 700 BEFORE MF3D ABB Group -11-650 63056 63081 63128 63136 63162 63163 Serial Number

Efficiency: Reduction of Losses Use of 3D magnetic field calculation tools to reduce Load losses: 800 Load Losses (kw) 400/230kV B450MVA 750 kw 778.5 kw (Avg) 700 BEFORE MF3D ABB Group -12-650 63056 63081 63128 63136 63162 63163 Serial Number

Efficiency: Reduction of Losses Use of 3D magnetic field calculation tools to reduce Load losses: 800 750 kw Load Losses (kw) 400/230kV B450MVA AFTER MF3D 778.5 kw (Avg) 707.7 kw (Avg) 700 BEFORE MF3D ABB Group -13-650 63056 63081 63128 63136 63162 63163 Serial Number

Efficiency: Reduction of Losses Use of 3D magnetic field calculation tools to reduce Load losses: 800 750 kw Load Losses (kw) 400/230kV B450MVA AFTER MF3D 778.5 kw (Avg) 707.7 kw (Avg) GARANTÍA 823kW 700 BEFORE MF3D 70.8 kw (9%) Load Losses Reduction ABB Group -14-650 63056 63081 63128 63136 63162 63163 Serial Number

Efficiency: Reduction of Losses Use of 3D magnetic field calculation tools to reduce Load losses: 800 750 Load Losses (kw) 400/230kV B450MVA AFTER MF3D 600 550 500 Losses (kw) 400/230kV kw 778.5 kw (Avg) 707.7 kw (Avg) 450 700 BEFORE MF3D 9% Load Losses Reduction kw 400 350 300 I2R Aditional 650 63056 63081 63128 63136 63162 63163 Serial Number 250 200 150 ABB Group -15- I2R Losses: Constant (1% diference) Aditional Losses (Eddy, CC, Stray): Before: 234kW (Avg.) 100 27% Reduction 63056 63081 63128 63136 63162 63163 Serial Number After: 170kW (Avg)

Sources of Noise from Power Transformers No - Load Noise Core Noise. Caused by Magnetostriction of core material. Cooling Equipment Noise. Caused by Fans and Pumps. Load Noise Leakage Flux. Produced by vibrations of the windings and tank. Exclusively 100 Hz or 120 Hz. ABB Group -16- Total Noise = No-Load Noise + Load Noise

Noise level reduction Sound power Radiation Classic acoustics: measurements statistics Tank resonance Structural dynamics Tank Vibration transmission Core resonance Oil transmission Winding resonance Transformer specific structural and fluid dynamics ABB Group -17- Core Magnetostriction NO-LOAD Windings Magnetic pull Electromagnetic Force LOAD CURRENT Classic Transformer physics

Noise level reduction Vibration isolation between core and tank Combined with evacuated membrane cells. Most effective for No-load sound. Membrane absorbers Combined with vibration isolated core supports. Sound panels 110 MVA transformer Tank-mounted sound panels covering 4 walls and top ABB Group -18- Reduction: 11 dba Sound pressure level 60 dba

Noise level reduction: Active noise control Active Noise Control Reduce tonal components of the noise spectrum. Features Reduce low frequency tones in several directions. It can be applied to existing transformers. ABB Group -19- Benefits Up to 15 db reduction @ 100/120 & 200/240 Hz No cooling perturbation Free access to the transformer for maintenance System could be reused on other transformers Allows to build houses closer to substations Increased value of the surrounding land

Noise level reduction: Active noise control Microphone Resonant Acoustic Device applied wave, equal in magnitude and 180 out of phase ABB Group -20- Analog/ Digital Digital Signal Processing Digital/ Analog Line Frequency Power Amplifier

Dry type transformers Continuous technology advances Dry type transformer technology, although well proven is relatively new and is in continuous development. New manufacturing processes. New insulation materials. Class F, Class H, Class C. Less size for the same power. New applications concept. Low losses. Green transformers. Low temperature designs. Special application designs. ABB Group -21-

Large Power & Large Voltage levels in Dry ABB Group -22- Dry type transformers have been historically been limited to MV applications Conventional voltage/power ranges in Dry type transformers HV up to 36 kv 170 kv BIL level Up to 10 MVA New power demands require larger transformers On Load Tap Changer Transformers Power above 40 MVA Voltage high level up to 52 kv series Higher voltages under development

Dry type transformers for Windmill applications Environmentally friendly Ecological: no risk of oil spillage. No visual impact of transformer located outside. Eliminates fire hazard. Safety for people and property. Special designs Reduced dimensions to enter through the door. Up to 4500 KVA Transformer installed in the Nacelle. Prototypes up to 6000 KVA. ABB Group -23-

Applications dry type Urban Substations Saving in losses with Dry transformers. Sitting the power transformers five km closer to the load enables 69 kv cable to be used (instead of 24 kv cable) for the extra distance. Quantified over a 30-years period, the total saving is 8.5 Gwh or 280 MWh per year. The saved losses can be also expressed in terms of reduced emissions (CO2, SO2, NOx) ABB Group -24-

Transformer solutions to secure the supply In today s competitive environment, it is imperative to assure a secure supply of electricity with: Strict cost control. Reliability and Quality. As a consequence, there is a need of: Increased equipment utilization. Reduction of forced outages. Reduction of failure rates. ABB Group -25-

Transformer solutions to secure the supply Large power transformers reliability is very important: They are critical for the operation of the system. Their replacement implies considerable time and cost. ABB Group -26- Actions to optimize performance and reliability: (1) Scheduled and predictive maintenance operations: - To determine and follow up the actual condition of the transformers. - Minimizes incidences. - Optimises performance. (2) Contingency planning: - Arrangements in case of a transformer failure that results in a prolonged outage. - To mitigate risks. It includes: Redundant transformers. Spare units.

Polytransformer The Multivoltage Substation Power Transformer ABB Group -27- Different voltage levels both in HV and LV. Multiple voltage levels on tertiary winding. Designed to be connected to different transmission systems. Compact easy to transport. Designed to be used as universal spare. Minimizes number of spare units even in case of complicated networks.

Polytransformer The Polytransformer may be used for several applications: (1) Spare Transformer: The Polytransformer may replace a wide number of different transformers from several substations. The Polytransformer is a multi-voltage spare transformer that can be used as a universal spare unit. ABB Group -28- (2) New Substations: The standardized design allow the Polytransformer to be used in new substations. It can be installed permanently on-site or used as temporary replacement of other units.

Polytransformer ABB Group -29- (3) Valuable asset: It can be rented, leased or lent to others in case of emergency or temporary need to cover the requirements of other utilities. (4) Peaks of load: It could be used to provide additional power in the network during seasonal or emergency consumption peak periods. This reduces the risk of black outs, and will prevent other installed units from being overloaded. (5) Reduction of inventory and maintenance cost: As the Polytransformer can take the place of different transformers, the total fleet of transformers in a system could be reduced, reducing the inventory, investments and maintenance costs.

Polytransformer ABB Group -30- All available transformation ratios (REE, Politrafo) HIGH LOW TERTIARY 400kV 230kV 33kV 400kV 138kV 33kV 400kV 110kV 33kV 400 kv 230 kv 26.4 kv 400 kv 138 kv 26.4 kv 400 kv 110 kv 26.4 kv 400kV 230kV 24kV 400kV 138kV 24kV 400kV 110kV 24kV 230kV 132kV 19kV 230kV 107kV 19kV 230kV 132kV 15kV 230kV 107kV 15kV 230 kv 132 kv 13.8 kv 230 kv 107 kv 13.8 kv

Polytransformer Assembled dimensions and weights: The autotransformer was designed to be mechanically and electrically compatible with other three phase transformers installed in the 400kV transmission system (up to six existing different designs). 1 2 3 4 5 6 ABB Group -31-

Universal GSU s In a generating power plant, the transformer may become the fuse. In a 500 MVA power plant, 1 day of outage means 500 k. The time to deliver a new transformer today could be higher than 12 months. The universal GSU is a unit designed to substitute several transformers in different power plants. One single spare transformer: To work on the highest power range. To work on with all different voltages on high and low. Transported to any of the power plants. Compatible with all installation constrains in each plant. ABB Group -32-

Application of universal GSU to Spanish CCC ABB Group -33- Uds MVA unit MVA total Tensión AT 1 400 400 420 2 320 640 420 2 500 1000 220 2 500 1000 220 1 480 480 400 1 400 400 420 2 315 630 420 1 485 485 415 1 475 475 230 1 500 500 230 1 508 508 230 3 105 315 230 2 480 960 415 1 345 345 410 2 315 630 410 1 530 530 220 3 370 1110 415 1 470 470 230 3 471 1413 406 3 312 936 405 1 500 500 230 3 380 1140 415 2 550 1100 400 1 485 485 230 3 380 1140 415 44 17592

Application of universal GSU to Spanish CCC ABB Group -34- Uds MVA unit MVA total Tensión AT 1 400 400 420 2 320 640 420 2 500 1000 220 2 500 1000 220 1 480 480 400 1 400 400 420 2 315 630 420 1 485 485 415 1 475 475 230 1 500 500 230 1 508 508 230 3 105 315 230 2 480 960 415 1 345 345 410 2 315 630 410 1 530 530 220 3 370 1110 415 1 470 470 230 3 471 1413 406 3 312 936 405 1 500 500 230 3 380 1140 415 2 550 1100 400 1 485 485 230 3 380 1140 415 44 17592 Universal GSU Type 1 230/19-20-21 4 Power Plants 4 Transformers 2030 MVA Universal GSU Type 4: 230/17-19-21 2 Power Plants 2 Transformers 985 MVA Universal GSU Type 2: 400/15-17-19 8 Power Plants 15 Transformers 5875 MVA Universal GSU Type 3: 230/17-19-21 2 Power Plants 2 Transformers 978 MVA 4 Universal Generator Step Up will cover: 9868 out of 17592 MVA (56%) 23 out of 44 Transformers (52%) 16 out of 25 Power Plants (64%) For 3 different utilities.

On field repair and upgrading ABB Group -35- Transformers repairs. Field repairs provide: A reduced cost solution. Shorter total repair time. Proved quality and reliability of the final result. Some advantages and key points are: Reduced cost and shorter repair time compared to shipment to a repair facility. Possibility to follow the same process than in a manufacturing facility, including change of windings and hot oil spray processing. HV dielectric testing (induced test with PD measurements) using portable testing equipment provides additional verification of an adequate repair quality.

On field repair or upgrading and HV testing State of the art equipment and processes to repair and upgrade transformers on site providing: Clean environment. Heavy lifting capacity. Experienced teams of skilled workers. Special tools and fixtures. Drying capabilities. Testing capabilities. ABB Group -36-

On field repair or upgrading and HV testing Shell Type, Spain Almaraz NPP GSU Transformer WES 400 MVA, 400 kv ABB Group -37-

On field repair or upgrading and HV testing Generator Step Up transformer: 3ph, Core type, 500 MVA 220/19 kv Scope of repair at site: Untanking and dismantling of the unit Exchange of High Voltage winding Core refurbishment Reassembly Drying out HV Tests Commissioning ABB Group -38- Time challenge: Site total repair time: 3 months Factory repair: 5 months + Trans. risk New unit: production time ~ 14 months + transportation time

Transformer Development, Innovations and Solutions Innovation and development: Efficiency: Reduction of losses. Noise level reduction. Dry type transformers of higher voltages. Transformer solutions: Polytransformers and universal GSU s. On field repair and upgrading. HV testing on site. ABB Group -39-

Transformer Development, Innovations and Solutions Thank you for your attention! Questions? Questions or comments: miguel.oliva@es.abb.com ABB Group -40-