Similar documents
Emergency Shock Absorbers WN-M 1,5. Deceleration Technology. ONLINE Calculation + 2D / 3D CAD Download. F m

Deceleration Technology. Shock Absorbers WM-E 1,5. Old Series: Do not use for new designs. ONLINE Calculation + 2D / 3D CAD Download

Shock Absorbers for P.E.T. Machines W-PET

Heavy-Duty Shock Absorbers HLS-110. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download. F m

Elasto-Fluid Springs WES-F. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download

Heavy-Duty Shock Absorbers LDS 25. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download. F m.

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

Pallet Stoppers WPS 500. Deceleration Technology. ONLINE 2D / 3D CAD Download

Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating

Miniature Shock Absorbers SC190 to SC925 Soft-Contact and Self-Compensating

Miniature Shock Absorbers MC150 to MC600 Self-Compensating

Safety Shock Absorbers SCS33 to SCS64

Heavy-Duty Shock Absorbers LDS

Safety Shock Absorbers SDH38 to SDH63

Heavy-Duty Shock Absorbers

Heavy-Duty Shock Absorbers

Linear drives DGC Key features

Controlflex Installation and operating manual

Feed separators HPVS

Heavy-Duty Shock Absorbers

GRIPPERS SERIES P3 - P12 ACTUATORS

Contamination switch VS

Safety Shock Absorbers SDP63 to SDP160 For Crane Installations

Cylinder Accessories Piston rod mountings, series CM2 Rod clevises. Brochure

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Hinge cylinders DW Key features

Mini slides DGSL. Festo core product range Covers 80% of your automation tasks

Hydraulic Power Packs

-H- Note. Feed separators HPV Key features at a glance. Separation of workpieces in the supply process

Smartflow FasTie Quick-Connect Ejector Tie-In System

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Breathing and air bleed filter, water-absorbing. Type BFSK. Contents. Features. RE Edition: Replaces: 51412

Linear Drive with Ball Screw Drive Series OSP-E..SB

SPRING HANGERS, SPRING SUPPORTS PRODUCT GROUP

Warranty. (Product Disclosure Statement, PDS) 36 months or 2,000 service hours For Shindaiwa manufactured Mobile Generators and Welders

Twin Rod Non Rotate Cylinders RDV and AZ

Kuhnke Technical Data. Contact Details

SKF Grease injection system

Vent and bleed filter, water-absorbing. Type BFSK 25 to 125. Contents. Features. RE Edition: Replaces: 05.13

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Angle Sensor WS1. RE Edition: Replaces:

Passive guide axes DGC-FA, without drive

Operating Instructions

Ametric Automation & Deceleration Technology

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Operating instructions

Extruded Body Cylinders, ISO 6431, ISO compliant Series 61

Hinge cylinders DFAW

VITA VACUMAT 6000 M. Date of issue: 06.11

Rotary-linear actuator HSE4 Hydraulic / 100 bar. GATEWAY to new technologies.

Tie-rod Cylinders, ISO 6431, ISO compliant Series 60

Slide units SPZ, twin piston

Linear drives DGC. Festo core product range Covers 80% of your automation tasks

WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals!

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Cartridge cylinders EGZ

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

BODAS Temperature sensor for fluids TSF

Active and Passive Brakes Series OSP-P

TY / TY User Manual

CD Couplings SERIES A1C. MTY (81) MEX (55) QRO (442) DIST.

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Our policy is one of continued research and development. We therefore reserve the right

SBM TECHNOLOGY PET Blow Valve Block

Standard Hydraulic Cylinder range

Modular. Robust. Flexible. SWS Quick-change system

Spring hangers, spring supports

HST -LS Interlocking device (Translation of Original Manual)

RA/28000, RA/ Pneumatic Cylinders ISO 6431, VDMA and NFE Non-magnetic and Magnetic, Single Acting 32 to 100 mm

-V- New. Linear drives DGC Features. 2 Internet:

SBM TECHNOLOGY Cooling / Air Recovery Valve

BALL VALVE - 340BA SERIES Pneumatic actuator - El-O-Matic

INTERNATIONAL STANDARD

BODAS Pressure sensor PR3 series 10

TITGEMEYER Tb1421GB(1115)1. TIFAS LockBolt Pin and collar fastening system

RODLESS CYLINDER SERIES PU ACTUATORS

The Medium Breaker range. Genuine all-rounders dependable, powerful, versatile

Planar surface gantry EXCM-30. Instructions. Mechanical installation b [ ]

MANUAL. Single charger

Operating instructions friction couplings ECS and ECSK

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

General Guidelines. Safety

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

HOW TO INSTALL YOUR BOV

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

KeContact P20. User manual

Installation and Maintenance Manual

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Pneumatic grease pump 50:1 and grease supply system

Round cylinders DSNU/ESNU

Power Transmission. Installation and Operating Instruction for Brake Caliper DU 060 PFM. E e.

Our policy is one of continued research and development. We therefore reserve the right to amend,

ELECTRIC ACTUATOR - RODLESS ELEKTRO SK SERIES ACTUATORS

Single and double-acting, magnetic, cushioned Standard, low friction, low temperatures and tandem versions ø 32, 40, 50, 63, 80, 100, 125mm

01 09 Installation guidelines Air suspension units GL70 GL70HD GL70L GN Air suspension units GL70 GL70HD GL70L

Aluminium profile. TANDEM: Double thrust and traction forces. LOW FRICTION: Friction force reduced by over 40%

Front panel valves SV

Transcription:

Special Shock Absorbers P.E.T. Machines W-PET 1,0-120 W-PET 1,0-1120 Deceleration Technology ONLINE Calculation and 2D / 3D CAD Download F m V S

Benefits Extended life time Piston Temperature Integrated stop RoHS - compliant Up to 20 Mio strokes Hardened, Titanium aluminium nitride Special Seals + Oils -30 C - +100 C Max. security Minor scheduled maintenance Lower maintenance costs Simple replacement against existing shock absorber Directive 2002/95/EC

Hardened aluminium-titanium coated piston for a long service life Integrated end-stop High temperature seals Pro-Surf for high corrosion resistance Weforma PET shock absorbers are designed for use in blow molding machines. Due to high cycle times standard shock absorbers quickly fail. Series W-PET provides constant performance for up to 20 million cycles in approved applications such as: P.E.T. container manufacturers Blow molding machines Injection molding machines Plastic bottle manufacturers High-speed, repetitious applications requiring exceptional durability and performance

F A B Hub Stroke M L C GW øe øf (AP2) ød SW1 SW DIMENSIONS Stroke Energy absorption GW A B C ød øe øf (AP2) F SW L SW1 M mm Nm/Hub (max.) mm mm mm mm mm mm mm mm mm mm mm W-PET 1,0-120 25 100 M27x3 135 102 3,5 6 12 17 139 30 8 23 13 W-PET 1,0-1120 25 100 M27x3 135 102 3,5 6 12 17 139 30 8 23 13 Accessories 2 Lock nuts Stop cap AP2 (lose mitgeliefert) W-PET 1,0-120 X X W-PET 1,0-1120 X X

Safety Instructions Before installation, commissioning, servicing and repair the data sheet is to be noticed. This work may only be performed by trained, introduced staff. Electric connections according to the suitable national regulation. For Germany: VDE regulation VD E0100 Before all repair and servicing works the energy supplies (main switch, etc.) have to be switched off! Moreover, measures are necessary to prevent an unintential reconnect. For example, a warning sign service works or maintenance work, applied to the switch. Designated use Check before installation and make sure the type name on the shock absorber or on the packaging is corresponding with delivery note. Industrial shock absorbers are maintenance-free and ready for installation. Temperature influence: at higher temperatures the shock absorber characteristic will change. Movable loads have to be protected during the installation and maintenance against unintentional processes. In operation outside the allowed temperature range, the shock absorber can lose his function. Due to heat radiation don t paint the shock absorber. Fluids, gases and a dirty environment can affect or destroy the sealing system of the shock absorber. The result could be a failure malfunction. Piston rod and sealing system has to be protected against fluids, gases and a dirty environment. Damages at the piston rod can destroy the sealing system. Don t grease or oil the piston rod. Avoid traction forces on the piston rod to present internal damages. The shock absorber can be pulled out of the construction during the impact.the construction needs to be able to resist the max counterforce. Sufficient security must be calculated. The maximum counterforces performed in the calculation program can vary from the really appearing counter forces, because these are based on theoretical values. Fundamentals Shock absorbers may under no circumstances be: -painted -welded -held with clamps -used on pull* (exception: clevis mounting) In hazardous environments (dirt, humidity, oil) shock absorbers must be protected against damage and failure with the necessary accessory. If several shock absorbers are used on the same application, the deceleration has to be distributed equally. The Torque (PERFORMANCE) indicates the maximum force by using the flats. The Weforma catalogue shows technical data with both minimum and maximum values. If a product is to be used in continuous operation and within a range of 20% from the minimum and maximum values shown, then written confirmation of suitability of use from Weforma is necessary.

Important information Integrated end-stop If the integrated end-stop is used the remaining energy before end of stroke must not be higher than 10% of the total energy. Installation situation The installation situation is any, however always in such a way that the complete shock absorber stroke can be used. The shock absorbers must be mounted like that the forces in centerinke about the piston rod are initiated. The maximum angle out of centre amounts to 3. Liability Due to the number of possible uses of our products and the conditions of use that lie outside of our scope of influence, we accept no liability as to whether the purchase object is suitable for the Client s intended purpose. The verification to this effect, in particular the verification as to whether the purchase object is suitable for the planned use, is the responsibility of the Client alone, unless expressly agreed otherwise in writing. For the reasons we accept no liability for the suitability of the purchase object for the purpose intended by the Client, except in cases of intent or gross negligence. With damages, the not designated use and from high-handed, in these instructions do not originate to intended interventions, any guarantee and liability claim goes out towards the manufacturer. Guarantee By non-use of the original spare parts the guarantee claim goes out. Environment protection By the exchange from damaged parts is to be respected to a proper disposal.