EVE. Silicon gasket. Ex de

Similar documents
EWE. Cooling fins. Ex de

EWE. Ex de. Cooling fins

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

FHL. Ex d. Body in aluminium

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

M-0. M-0... series control, monitoring and signalling devices. Ex e

YFC. Limit switch. Ex d. 24 operating head types

PY, SPY; FSQC, FP; EPC; AP

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

CCAI, CCAIF, CCAIF..H

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Junction boxes for control, monitoring and control panel Ex tb

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

CTB. Ex e. Captive screws B.67. Detail of TIG welding of walls. Earth stud with cable anti-rotation bracket

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Light Fitting for Fluorescent Lamps Series 6009

Compact Sheet-Steel Light Fittings Series 6114/1

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Floodlight LED Series 6525

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight LED Series 6525

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Floodlight Series 6521/4

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Emergency Luminaire with LED Series EXLUX 6409/1

Floodlight LED Series 6125

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Terminal Boxes Series 8125

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

New products Ex Equipment 2015

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Floodlight Series 6121

K: bracket type. L: pole type

Operating Instructions

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Sheet-Steel Light Fittings Series 6014 / 6414

7 Lighting Technology

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D

Tank Inspection Lights Series 6122

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

7 Lighting Technology

Compact Sheet-Steel Light Fittings Series 6114

INSTRUCTION MANUAL (ATEX / IECEx)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

LED Linear Luminaire Series EXLUX 6402

Operating Instructions

L-3000, L-5, L-5R. - High efficiency - Smart energy saving - IP67 protection rating - Exceptional ergonomic design - Zone 0, 1, 2 L-5R L-5 L-3000

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Easy and safe installation

Terminal Boxes TNCN. Explosion protection Marking

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Pendant Light Fitting IEC

Linear fittings EVDL LED fitting - zones 21, & 22

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

ILED Aquarius Illuminated Windsock. User Manual

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

P, I, A. Command and control stations Ex e

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

INSTRUCTION MANUAL (ATEX / IECEx)

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Position Switches Series 8060/2

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

PRE Series 63 Amp Plugs and Sockets Increased Safety

Position Switches Series 8074/2

Zone 1 Linear Range - Installation Guide

EX-D ENCLOSURES AND DISTRIBUTIONS

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Position Switches Series 8070/2

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Transcription:

EVE - Optimal performance at high (+ C) and low (- C) temperatures - Easy to install, low maintenance costs - Zone 1, 2, 21, 22 Silicon gasket 4 Joule shock resistant borosilicate glass globe Stainless steel reflector fixing screw Stainless steel protective guard B.9 ED.2018

EVE series Lighting fixtures for energy saving lamps EVE series lighting fixtures have been specially designed for use in the petrochemical and oil refining industries as they combine beauty and functionality along with high performance and simplicity in complete compliance with the technolo gical requirements of the Ex sector. The low copper content aluminium alloy, shockproof borosilicate glass and electropolished stainless steel components make these lighting fixtures ideal for use in environments with corrosive atmospheric agents, salts and industrial pollution. Mechanical characteristics such as ceramic lamp holders with high heat resistance and insulating properties and acid-proof neoprene gaskets guarantee a long working life with little maintenance. Scheduled maintenance work involves simply cleaning the glass that, thanks to its IP66 protection, can be safely cleaned with a wet cloth. Electrical connection is made via a terminal box in a Ex e compartment that allows the entry to the lighting fixture through an Ex O-ring (non barrier) cable gland as specified in the installation specification standards (EN/IEC 079-14). Application sectors Oil refineries Chemical and petrochemical plants Onshore plants Offshore plants Low temperatures Fuel depots Fuel tanker loading/ unloading areas 100% Cortem product CERTIFICATION DATA Classification: Group II Categoria 2GD Installation: EN 079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2GD Ex e mb IIC T.. Gb - Ex tb IIIC T.. C Db IP66 Certification: ATEX CESI 12 ATEX 006 IEC Ex CES 07.0004 TR CU AVAILABLE All IEC Ex and TR CU certification data can be downloaded at www.cortemgroup.com Standards: CENELEC EN 079-0: 2012, EN 079-1: 2007, EN 079-7: 2007, EN 079-31: 2009 and EUROPEAN DIRECTIVE 2014/34/UE IEC 079-0: 2011, IEC 079-1: 2007, IEC 079-7: 2007, IEC 079-31: 2008 European Directive 2006/95 Low voltage European Directive 2004/108 Electromagnetic compatibility European Directive 2003/108 WEEE Waste electrical and electronic equipment European Directive 2011/64 RoHS Class temperature: See the selection table Ambient temperature: Standard -20 C + C Special - C + C not possible for model EVE...100 Degree of protection: IP66 ED.2018 B.10

EVE series Lighting fixtures for energy saving lamps MECHANICAL FEATURES ORIGINAL PRODUCT Body: Globe: Gaskets: Guard: Mounting: Bolts and screws: Entries: Coating: Low copper content aluminium alloy Shock and temperature resistant borosilicate glass with aluminium shade ring Acid/hydrocarbon resistant silicone Electro-polished stainless steel. Can also be supplied on request without a guard as the lighting fixture has passed the glass breakage test (4 Joule EN079-0 / IEC079-0) See EVE series dimensional drawings Stainless steel See EVE series dimensional drawings Polyester coating Ral 35 (Light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN068-2-30 (hot/humid cycles) and EN068-2-11 (salt mist tests) ELECTRICAL FEATURES Lamp holder: E27 or E40 ceramic Rated voltage: 230 V AC Rated frequency: / Hz Connection: Direct connection to the terminal box L, N, Pe. Section 4 2 ACCESSORIES AVAILABLE / SPECIAL REQUESTS Energy saving lamps, halogen, mixed and LED lights External reflector Cable gland: REVD2IB for armored or REV2IB for non-armored cable Warning signs: G-0513 Swivel bracket for inclined mounting B.11 ED.2018

EVEA series selection chart Pendant mounting Code Dimensions A B Lamp type Lamp holder Watt Class Ta=+ C Max Surface Temperature C EVEA- 261 1 AL E 27 T4 123 1,9 1x1x330 Weight kg EVEA- 261 1 AL E 27 105 T3 154 1,9 1x1x330 EVEA- 261 1 AL E 27 140 T3 154 1,9 1x1x330 EVEA- 261 1 ELS E 27 15 T6 84 1,9 1x1x330 EVEA- 261 1 LED E 27 8 T6 74 1,9 1x1x330 EVEA- 323 1 EL E 27 23 T5 86 2,7 190x1x390 EVEA- 323 1 ELS E 27 23 T5 86 2,7 190x1x390 EVEA- 323 1 LED E 27 12 T6 74 2,7 190x1x390 EVEA- 357 200 MIX E 27 100 T3 152 3,7 210x200x430 EVEA- 357 200 MIX E 27 1 T3 152 3,7 210x200x430 EVEA- 357 200 EL E 27 33 T6 83 3,7 210x200x430 EVEA-80 430 220 MIX E 40 2 T3 166 6,0 230x220x510 EVEA-80 430 220 ELS E 27 42 T5 89 6,0 230x220x510 EVEA-100 489 280 ELS E 40 75 T5 88 8,7 280x280x8 EVEA-100 489 280 ELS E 40 105 T5 91 8,7 280x280x8 EVEA-100 489 280 MIX E 40 0 T3 185 8,7 280x280x8 EVEA Pendant mounting Key EL = Linear tubes (FBT) AL = Halogen (HSGSA) MIX = Mixed light (QB) ELS = Spiral tubes (FB) LED = With LED (DB) Dimensions in ED.2018 B.12

EVEGC series selection chart Pendant mounting with eyebolt Code Dimensions A B Lamp type Lamp holder Watt Class Ta=+ C Max Surface temperature C EVEGC- 296 1 AL E 27 T4 123 2,1 1x1x330 Weigth kg EVEGC- 296 1 AL E 27 105 T3 154 2,1 1x1x330 EVEGC- 296 1 AL E 27 140 T3 154 2,1 1x1x330 EVEGC- 296 1 ELS E 27 15 T6 84 2,1 1x1x330 EVEGC- 296 1 LED E 27 8 T6 74 2,1 1x1x330 EVEGC- 358 1 EL E 27 23 T5 86 2,8 190x1x390 EVEGC- 358 1 ELS E 27 23 T5 86 2,8 190x1x390 EVEGC- 358 1 LED E 27 12 T6 74 2,8 190x1x390 EVEGC- 389 200 MIX E 27 100 T3 152 4,5 210x200x430 EVEGC- 389 200 MIX E 27 1 T3 152 4,5 210x200x430 EVEGC- 389 200 EL E 27 33 T6 83 4,5 210x200x430 EVEGC-80 465 220 MIX E 40 2 T3 166 6,3 230x220x510 EVEGC-80 465 220 ELS E 27 42 T5 89 6,3 230x220x510 EVEGC-100 524 280 ELS E 40 75 T5 88 9,2 280x280x8 EVEGC-100 524 280 ELS E 40 105 T5 91 9,2 280x280x8 EVEGC-100 524 280 MIX E 40 0 T3 185 9,2 280x280x8 EVEGC Pendant mounting with eyebolt Key EL = Linear tubes (FBT) AL = Halogen (HSGSA) MIX = Mixed light (QB) ELS = Spiral tubes (FB) LED = With LED (DB) Dimensions in B.13 ED.2018

EVEIX series selection chart Wall mounting Code Dimensions A B C Lamp type Lamp holder Watt Class Ta=+ C Max Surface temperature C EVEIX- 285 1 310 AL E 27 T4 123 2,9 190x1x390 Weight kg EVEIX- 285 1 310 AL E 27 105 T3 154 2,9 190x1x390 EVEIX- 285 1 310 AL E 27 140 T3 154 2,9 190x1x390 EVEIX- 285 1 310 ELS E 27 15 T6 84 2,9 190x1x390 EVEIX- 285 1 310 LED E 27 8 T6 74 2,9 190x1x390 EVEIX- 339 1 344 EL E 27 23 T5 86 3,7 2x210x490 EVEIX- 339 1 344 ELS E 27 23 T5 86 3,7 2x210x490 EVEIX- 339 1 344 LED E 27 12 T6 74 3,7 2x210x490 EVEIX- 368 200 365 MIX E 27 100 T3 152 4,7 2x210x490 EVEIX- 368 200 365 MIX E 27 1 T3 152 4,7 2x210x490 EVEIX- 368 200 365 EL E 27 33 T6 83 4,7 2x210x490 EVEIX-80 435 220 409 MIX E 40 2 T3 166 7,5 240x240x0 EVEIX-80 435 220 409 ELS E 27 42 T5 89 7,5 240x240x0 EVEIX-100 488 280 448 ELS E 40 75 T5 88 8,7 280x280x8 EVEIX-100 488 280 448 ELS E 40 105 T5 91 8,7 280x280x8 EVEIX-100 488 280 448 MIX E 40 0 T3 185 8,7 280x280x8 EVEIX Wall mounting with 30 bracket Key EL = Linear tubes (FBT) AL = Halogen (HSGSA) MIX = Mixed light (QB) ELS = Spiral tubes (FB) LED = With LED (DB) Dimensions in ED.2018 B.14

EVEX series selection chart Ceiling mounting Code Dimensions Lamp type Lamp holder Watt A B Class Ta=+ C Max Surface temperature C Weight kg EVEX- 2 1 AL E 27 T4 123 1,9 1x1x330 EVEX- 2 1 AL E 27 105 T3 154 1,9 1x1x330 EVEX- 2 1 AL E 27 140 T3 154 1,9 1x1x330 EVEX- 2 1 ELS E 27 15 T6 84 1,9 1x1x330 EVEX- 2 1 LED E 27 8 T6 74 1,9 1x1x330 EVEX- 322 1 EL E 27 23 T5 86 3,3 190x1x390 EVEX- 322 1 ELS E 27 23 T5 86 3,3 190x1x390 EVEX- 322 1 LED E 27 12 T6 74 3,3 190x1x390 EVEX- 353 200 MIX E 27 100 T3 152 4,5 210x200x430 EVEX- 353 200 MIX E 27 1 T3 152 4,5 210x200x430 EVEX- 353 200 EL E 27 33 T6 83 4,5 210x200x430 EVEX-80 429 220 MIX E 40 2 T3 166 4,5 210x200x430 EVEX-80 429 220 ELS E 27 42 T5 89 7,6 230x220x510 EVEX-100 488 280 ELS E 40 75 T5 88 7,6 230x220x510 EVEX-100 488 280 ELS E 40 105 T5 91 8,8 280x280x8 EVEX-100 488 280 MIX E 40 0 T3 185 8,8 280x280x8 EVEX Ceiling mounting Key EL = Linear tubes (FBT) AL = Halogen (HSGSA) MIX = Mixed light (QB) ELS = Spiral tubes (FB) LED = With LED (DB) Dimensions in B.15 ED.2018

Selection chart for lighting fixtures with loop-in/loop out systems Code Dimensions A B Lamp type Lmap holder Watt Class Ta=+ C Max Surface temperature C Weight kg EVE - 294 1 AL E 27 T4 123 2,2 1x1x330 EVE - 294 1 AL E 27 105 T3 154 2,2 1x1x330 EVE - 294 1 AL E 27 140 T3 154 2,2 1x1x330 EVE - 294 1 ELS E 27 15 T6 84 2,2 1x1x330 EVE - 294 1 LED E 27 8 T6 74 2,2 1x1x330 EVE- 356 1 EL E 27 23 T5 86 3,5 190x1x390 EVE- 356 1 ELS E 27 23 T5 86 3,5 190x1x390 EVE- 356 1 LED E 27 12 T6 74 3,5 190x1x390 EVE- 387 200 MIX E 27 100 T3 152 4,1 210x200x430 EVE- 387 200 MIX E 27 1 T3 152 4,1 210x200x430 EVE- 387 200 EL E 27 33 T6 83 4,1 210x200x430 EVE-80 463 220 MIX E 40 2 T3 166 6,5 230x220x510 EVE-80 463 220 ELS E 27 42 T5 89 6,5 230x220x510 EVE-100 523 280 ELS E 40 75 T5 88 9,0 280x280x510 EVE-100 523 280 ELS E 40 105 T5 91 9,0 280x280x510 EVE-100 523 280 MIX E 40 0 T3 185 9,0 280x280x510 EVE Pendant mounting Key EL = Linear tubes (FBT) AL = Halogen (HSGSA) MIX = Mixed light (QB) ELS = Spiral tubes (FB) LED = With LED (DB) Dimensions in ED.2018 B.16

Selection chart for lighting fixtures with loop-in/loop out systems Code Dimensions A B Lamp type Lamp golder Watt Classe Ta=+ C Max Surface temperature C Weight kg EVES - 317 1 AL E 27 T4 123 2,7 1x1x330 EVES - 317 1 AL E 27 105 T3 154 2,7 1x1x330 EVES - 317 1 AL E 27 140 T3 154 2,7 1x1x330 EVES - 317 1 ELS E 27 15 T6 84 2,7 1x1x330 EVES - 317 1 LED E 27 8 T6 74 2,7 1x1x330 EVES- 379 1 EL E 27 23 T5 86 3,5 190x1x390 EVES- 379 1 ELS E 27 23 T5 86 3,5 190x1x390 EVES- 379 1 LED E 27 12 T6 74 3,5 190x1x390 EVES- 410 200 MIX E 27 100 T3 152 4,0 210x200x430 EVES- 410 200 MIX E 27 1 T3 152 4,0 210x200x430 EVES- 410 200 EL E 27 33 T6 83 4,0 210x200x430 EVES-80 486 220 MIX E 40 2 T3 166 6,5 230x220x510 EVES-80 486 220 ELS E 27 42 T5 89 6,5 230x220x510 EVES-100 546 280 ELS E 40 75 T5 88 9,0 280x280x510 EVES-100 546 280 ELS E 40 105 T5 91 9,0 280x280x510 EVES-100 546 280 MIX E 40 0 T3 185 9,0 280x280x510 EVES Ceiling mounting Key EL = Linear tubes (FBT) AL = Halogen (HSGSA) MIX = Mixed light (QB) ELS = Spiral tubes (FB) LED = With LED (DB) Dimensions in DON T FORGET TO ORDER THE ACCESSORIES Esempio: Tipo Armatura UBD5G Example: Type of lighting + + altro... vedi legenda EWL fixture Lamp Dome reflector -80 + Cavallotto per montaggio + a palo + other... see key LAMP-PL23 G-427D EVEA- ACCESSORIO RICAMBIO B.17 ED.2018

EVE... series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Halogen lamp Spiral electronic lamp E27 E27 -E40 W (HSGSAW) LAMPALW 105 W (HSGSA105W) LAMPAL105W 140 W (HSGSA140W) LAMPAL140W 15 W (FB15W) LAMPSP15W 23 W (FB23W) LAMPSP23W 45 W (FB42W) LAMPSP45W 75 W (FB75W) LAMPSP75W 105 W (FB105W) LAMPSP105W LED lamp E27 8 W (DB8W) LAMPLED8W E27 12 W (DB12W) LAMPLED12W E27 100 W (QB100W) LAMP100WHWL Mixed light lamp E27 1 W (QB1W) LAMP1WHWL E40 2 W (QB2W) LAMP2WHWL E40 0 W (QB0W) LAMP0WHWL Linear tube electronic lamp E27 23 W (FBT20W) LAMP-PL23W E27 33 W (FBT33W) LAMP-PL33W Cable gland For models and codes, visit www.cortemgroup.com REVD2IB REV2IB Swivel bracket for inclined mounting (see example in installation methods) Material: galvanised steel G-0543 G-0417 Protective guard Material: G-0417 electro-polished stainless G-0417 80 steel G80-0417 100 G100-0417 Ceramic lamp holder E27 2 V 4 A PORT E-27 E40 7 V 16 A PORT E-40 Globo OR-4512SHS O-ring Globo Globo Globo 80 Material: silicone K15-131S K33-131S K34-131S Globo 100 K27-131S ED.2018 B.18

EVE... series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Warning signs on the frame Materials: G-0513 translucent film on plexiglass and aluminium frame G-0513/1 Emergency Exit U-420/P Emergency Exit on the right U-420/P1 Emergency Exit on the left G-0513 G-0513/1 Material: film translúcido U-420/P2 Emergency Exit upward U-420/P3 Emergency Exit downward U-420/P4 White painted aluminium Stainless stee G-427 G-427IN White painted aluminium Stainless stee G-427 G-427IN Reflector White painted aluminium Stainless stee G-427 G-427IN 80 White painted aluminium Stainless stee G80-427 G80-427IN 100 White painted aluminium Stainless stee G100-427 G100-427IN Contact our Sales Office for availability White painted aluminium G-427D Dome reflector Contact our Sales Office for availability 80 White painted aluminium G80-427D 100 White painted aluminium G100-427D Contact our Sales Office for availability White painted aluminium G-427DI 30 inclined dome reflector White painted aluminium G-427DI 80 White painted aluminium G80-427DI 100 Contact our Sales Office for availability B.19 ED.2018

EVE... series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Ex e pendant mounting EVE Attacco tipo Ex e a soffitto EVES 80 100 80 100 3 x entries ISO M25 2 x entries ISO M25 G-0444 G-0439 G-0440CM Globe with shade ring Borosilicate G-0440CM glass globe Threaded aluminium G-0440CM 80 shade ring G80-0440CM 100 G100-0440CM Pendant eyebolt Material: galvanised steel GOF-8 Pendant mounting EVEA 80 1 x ISO M25 entry G-0213I 100 Pendant mounting with eyebolt EVEGC 80 4 x ISO M25 entries G-0216I 100 Ceiling mounting EVEX 80 4 x ISO M25 entries G-0214I 100 Wall mounting with 30 bracket 80 4 x ISO M25 entries G-0215I 100 ED.2018 B.20

Installation and mounting methods Example of swivel bracket mounting Example of ceiling mounting with lighting fixture for loop-in/loop-out Example of wall mounting Dimensiones en B.21 ED.2018

Photometric diagram EVE.. 23W EL EVE..80 2W MIX EVE..100 0W MIX On Cortem Group web site you can download.ldt and.ies lighting data files for the design and simulation of lighting levels in 2D and 3D, rendering and ray tracing. = plane 902 = plane 0180 ED.2018 B.22