Gusher 10. Easy grasp handle. Durability long life LM6 diecast alloy. Easy maintenance designed for instant access

Similar documents
Gusher Titan. Tough and Lightweight Polypropylene Models GUSHER TITAN combines powerful performance and lightweight design

INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

BP3000 / BP3010 / BP3020

Gusher 30. Ease of use easy grip handle. Ease of operation extra long handle

Diaphragm* Service Kits

To the Fitter: Ensure all relevant personnel read the points listed below and that a copy is passed on to the end user.

Marine. Leading marine systems. We are passionate about delivering quality, innovation and service

We are passionate about delivering quality, innovation and service. Marine Leading Freshwater, Bilge and Waste Systems

Whale - Electric Bilge Pump Range From the Experts in Bilge Pumps experience in electronics

Watermaster Exterior Socket (Part Number ES1001 or ES5001) Vehicle Wall Outside Caravan. Dust Cover. Water Container

Exterior Pump Range INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation and Maintenance Manual MRW-01. Radial Winch 20 ST

Installation and Maintenance Manual MRW-02. Radial Winch 20 ST

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Air Operated 1:1 Oil Ratio Pump OP-11

Radial Electric Winch 46 Rewind

HUGH CRANE. SOUTH WALSHAM ROAD, ACLE, NORWICH, NORFOLK, NR13 3ES TEL: FAX:

Installation and Maintenance Manual MRW-01. Radial Winch 40.2 ST

D 40 ALUMINIUM (CLAMPED)

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

D 25 POLYPROPYLENE (BOLTED)

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

80 Litre Suction Oil Drainer With Inspection Chamber

AJAX PUMPS PUMPS AJAX. ~Pli~r. on s SYDNEY BRISBANE ADELAIDE PERTH. ~Pli~[ ODS ~ISTON PURPOSES

SERIES PC INSTRUCTION AND OPERATION MANUAL

Intelligent Water Systems for Intelligent Boats

INSTRUCTION MANUAL (original instructions) K2, K3

Performa Winch 50.2 STP

08 general Purpose Pumps

Electric Diesel Pump EDP/12, EDP/24

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Performa Winch 80.2 STP

Performa Winch 70.2 STP

Series 900 Minifolds. Aluminium Air Distribution Manifolds. Manifolds & Minifolds. Technical Specifications. hnl-uk.com. Series 900 Minifolds

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

Installation and Maintenance Manual MRW-01. Radial Winch 40.2 PT

PART 8 MACHINERY INSTALLATIONS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Performa Winch 80.3 STP

Installation and Maintenance Manual MRW-02. Radial Winch 80.3 ST

POND PUMP Model Nos:SPP3 & SPP6 0200

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

WARNING Carefully Read These Instructions Before Use

Illumifalls Patio Pond

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

Page ATALOGUE. Web: Tel: Fax:

Performa Winch 40.2 STP

CROMMELINS FIRE FIGHTING PUMP SINGLE IMPELLER

F479 HVE V PARTS LIST

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

Principal Dimensions:

Model: PumpAgents.com - buy pumps and parts online JABSCO Y-VALVE. Model: FEATURES INSTALLATION APPLICATION

Operations Manual. and. Seal Kit Replacement Guide

Installation & Operator s Manual

02 Bilge Pumping Systems

PA 32. Parts Manual HEDGE/GRASS TRIMMER. Publication 410 August 2001 Part No Revision:

Model &

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

jbs nfb INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Jet Boat Mechanical Steering HELM MOUNTING KIT SB39462

Temperature Regulator I-1285-B through G Series (Bronze Valve Body)

262CC. Quick Start Guide

MM184 Rev. 12 (9 94)

07 Oil Change & Diesel Transfer Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

JACKALL HYDRAULIC SYSTEM

Installation & Operator s Manual

3/4 Fittings. 3/4 Fittings

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

SERIES OPERATION AND MAINTENANCE MANUAL

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Servicing the Tool. Service Kit SERVICE KIT. For all servicing we recommend the use of the service kit (part number (S)).

POMPE AUTOADESCANTI SELF-PRIMING ELECTRO PUMP ACM DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR MULTISTAGE SELF-PRIMING PUMPS

OPERATION MANUAL 1 POLYPROPYLENE PUMP DURA-FLO TM AIR DISTRIBUTION SYSTEM

Radial Electric Winch 60 Rewind

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Troubleshooting WARNING

E3 3" Bolted Metallic Pumps Operating Instructions

Air Lift. Kit Honda Prelude ( ) PERFORMANCE INSTALLATION GUIDE

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Warning. Document ref: A October 2015

PRESSURE REDUCING VALVES

E1 1" Bolted Plastic Pumps With Metallic Center Sections Operating Instructions

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Parts Manual E 24 Walk-Behind Scrubber

Performa Winch 35.2 PTP

Powered Radial Winch 60.2 ST E/HY

07 Oil Change & Diesel Transfer Pumps

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series

SAFETY MANUAL READ FIRST!

...your single dedicated resource for cost-effective mine pumping solutions. For Rugged Mining Duty

SILI PUMP, Your reliable one-stop supplier of marine pumps.

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

Transcription:

Whale's long life diecast alloy range Gusher 10 The original bilge pump choice for sailors in extreme conditions Durable Diecast Alloy Bilge Pump Top performance - 65 ltrs (17 US gals) minute, robust design stands up to the toughest marine conditions Easy grasp handle Durability long life LM6 diecast alloy Easy maintenance designed for instant access Simple plumbing 38mm (1½") smooth hose connections Product code: see table Mounting options Models on-deck / Thru-deck options High flow non choke valves no filter to block or clean 34 34Manual Bilge Schiffsausrüster Tel.: +49 (0)40-88 90 100 www.toplicht.de

Features and Benefits Robust design stands up to the toughest marine conditons Top performance - 65 ltrs (17 US gals) per minute Mounting options On Deck / Bulkhead, Thru deck Designed for simple installation and maintenance Efficiency - Large non-choke valves Ideal for workboats, cruisers, offshore racing Easy pump action - Self priming Typical uses - Bilge pump out / holding tank pump out 5 Year Warranty Awards and Accreditations Suitable as a primary bilge pump on boats equal to or greater than 12m (40ft) in accordance with ISO15083 COMPLETE YOUR SYSTEM Whale high quality bilge accessories including non-return valves, elbows and Y pieces see page 48-51 MANUAL BILGE i Product Information Gusher 10 Mk3 Standard BP3708 Gusher 10 Mk3 Thru Deck/Bulkhead BP3740 Model Specifications Model On Deck / Bulkhead Thru Deck / Bulkhead Product Code BP3708 BP3740 Weight Hose Connections Materials Materials Contact With Fluid Service Kits Accessories Maximum Suction Lift Maximum Discharge Head 2.3 kg (5 lbs) 38 mm (1 1 2") Smooth Hose Connections Pump Body: Marine Grade LM6 Aluminium Alloy (epoxy coated) Diaphragm: Neoprene (Nitrile option available) Fasteners: Stainless Steel Marine Grade LM6 Aluminium Alloy (Epoxy Coated) Neoprene, Nitrile, Stainless Steel AK3706 - Neoprene Parts AK3714 - Nitrile Parts for Oil and Diesel Contains: Diaphragm, Valves, Seals DP3804 - Alloy Deck Plate DP8904 - Plastic Deck Plate Lid AS4405 - Spare Handle 4 m (13.5 ft) 4 m (13.5 ft) Front View Side View Side View Typical Installation Performance Data BP3708 / BP3740 BP3708 / BP3740 Suction Lift 1 m (3 ft) 2 m (6 ft) Discharge Head 0.5 m (1.5 ft) 0.5 m (1.5 ft) 45 Strokes per Minute 41 ltrs (11 US gals) 41 ltrs (11 US gals) 70 Strokes per Minute 65 ltrs (17 US gals) 65 ltrs (17 US gals) Note: These specifications are retail items only. For details of our bulk pack range for boat builders and wholesalers - contact Whale Support. 35

Manual Bilge Pumps Gusher 10 Mk 3 On Deck/Bulkhead : BP3708, Thru Deck/Bulkhead: BP3740 - Diecast Alloy Bilge Pump Note* Contained in Service Kit AK3706 (Neoprene ) or AK3714 (Nitrile ) CURRENT MODEL AS4405 Handle assembly S/S Bridge piece & screws* Valve* AS3719 Eyebolt & clamping plate assembly DP3804 Metal deckplate with lid Diaphragm* Gasket* Bridge piece & screws* Valve* Buffer* AS3723 Outlet valve plate assembly AS3725 Gaiter & O-ring kit AS3780 Fork assembly Accessories Service Kits DP3804 Alloy Deckplate DP8904 Plastic Deckplate with Lid AS4405 Spare Handle SB4222 Side Entry Strainer SB5865 Top Entry Strainer SF5425 1 1 /2 Skin Fitting LV1215 1 / 1 1 /2 Non Return Valve EB3488 1 1 /2 Elbow AK3706 Service Kit with Complete Set of Serviceable Parts for Whale Gusher 10 Mk 2 & Mk 3 Pumps (Neoprene ) (See list below) AK3714 Service Kit with Complete Set of Serviceable Parts for Whale Gusher 10 Mk 2 & Mk 3 Pumps (Nitrile ) 2 Valve (Mk 2 pump only) 4 Screw 3 /8 4 Screw 1 /2 2 Bridge piece 1 Diaphragm 1 Buffer 2 Valve (Mk 3 pump only) 1 Gasket (Mk 3 pump only) AS3719 Bushed Eyebolt & Clamping Plate Assembly 2 Clamping plate 1 Nut 1 Fulcrum bush 1 Eyebolt 1 Buffer 1 Label AS3780 Fork Assembly 1 Fork 1 Insert fork 2 Bolt 2 Fulcrum sleeve 2 Nut 4 Washer 2 Fulcrum bush

Manual Bilge Pumps Gusher 10 Mk 3 On Deck/Bulkhead: BP3708, Thru Deck/Bulkhead: BP3740 - Diecast Alloy Bilge Pump AK3706 AK3714 AS3719 AS3723 AS3725 AS3780 AS4405 DP3804 DP8904 SB4222 SB5865 SF5425 Note: Cast body and mounting bracket are not available as service parts. Service Kits (Continued) AS3723 Outlet Valve Plate Assembly (Mk 3 only) 2 Screw 4 Screw 1 Bridge piece 1 Valve (Mk 3 Pump) 1 Valve plate 1 Gasket AS3725 Gaiter Kit for Deckplates 1 Gaiter (for metal or plastic deckplate) 1 O-ring (for metal deckplate)

Whale Gusher 10 MK3 Pump Models: BP3708 and BP3740 READ CAREFULLY BEFORE INSTALLATION AND USE To the Fitter: Check that the product is suitable for the intended application, follow installation instructions and ensure operating instructions are passed on to the end user. To the User: Read the instructions carefully. (See parts diagram) APPLICATION This bilge pump is designed exhaust standing water. Output capacity depends on installation conditions and pumping rate. Users should be aware that capacity may not be sufficient to cope with rapid influx of water. If it is intended for any other purpose or with any other liquid, it is the users responsibility to ensure that the pump is suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used. With all applications it is important that a system of safe working practice is applied to installation, use and maintenance. INSTALLATION The Gusher 10 is designed for mounting on or through deck, or on or through bulkhead. The handle can be fixed in four different positions relative to the inlet and outlet (see Fig. 1) To Reposition Handle:: (a) Slacken wormdrive clip and remove diaphragm (b) Undo the bolts from bracket and rotate body to new position relative to the fork and diaphragm. Note: Inlet and outlet are always at 180 to each other (c) Reassemble bolts, washers and securing brushes in bracket and tighten Select a suitable position free from obstructions where the pump can be operated efficiently and comfortably To minimise pumping effort, site the pump halfway (in height) between the strumbox / strainer and hull outlet Avoid installations which require a cockpit locker to be opened in order to operate the pump. To ensure good priming and flow, avoid sharp bends in pipework and fit a Whale strumbox/strainer (incorporating a non-return valve) which prevents the end of the hose sucking against a flat surface and allows the water level to be reduced to a minimum. Ensure that the pump is installed to allow easy access for servicing. For Mounting On Deck/Bulkhead: 1. Use pump as a template, mark off and drill four 1/4 (6mm) holes. 2. Check flow direction and secure the pump with 1/4 (6mm) bolts. 3. Attach 1 1/2 (38mm) smooth bore reinforced hose with stainless steel worm drive hose clips. Tighten to prevent air leaks 4. With thru-hull discharge, make sure that the discharge point is well above the water line. 5. Check the installation for air leaks, correct priming and discharge For Mounting Underdeck or Thru Deck/Bulkhead Three deckplates available - see accessories 1. Using template mark off the 6 holes for the mounting and cut out the hole for the pump handle. Round off top edge of large hole as shown in fig. 3. Deck fitting for Gusher Pumps (Half sectional elevation of deck fitting, pump and bracket) Fig 3 Fig. 1 - Mounting arrangements for a standard model Fig 2 2. Minimum deck thickness required is 1/4 (6mm). For thinner decks use a backing plate of suitable thickness so that the backing plate plus the deck is at least the minimum thickness and no greater than 1 (25mm). Bond the backing plate to the deck. If using Deck plate DP3804 the minimum deck thickness is 1/2 (13mm) 3. Position the pump under deck and check flow direction. Work the rubber gaiter up through the hole until its flange rests on the deck. Secure the 6 1/4 (6mm) countersunk mounting screws provided. 4. As points 3-5 of previous instructions.

OPERATION The Gusher 10 ensures efficient throughput with an easy pumping action. Full even strokes will obtain the best results. The detachable handle is fitted with a lanyard and should be safely secured close to the pump. Gusher 10 output at 1m Lift and 0.5m Head Ouput Fig 3: Performance table Performance data is based on factory tests and is typical of what may reasonably be achieved. Actual performance may vary depending on installation and operating conditions. MAINTENANCE At 60 strokes/min At 70 strokes/min Gallons/min 16 20 Litres/min 74 71 ACCESSORIES DP3804 - Alloy deck plate with lid DP8903 - Plastic deck plate AK3706 - Neoprene Spares Kit AK3714 - Nitrile Spares Kit SF5425 Skinfitting SB5865 Top entry strainer SB4222 Side entry strainer DV5606 2 way diverter valve EB3488 90 elbow (male to female) LV1215 In line non return valve HELPFUL HINTS Pump fails to prime or chokes: 1. Check inlet hose connection is airtight, free from blockages and does not collaspe during suction stroke 2. Inspect diaphragms - replace if damaged 3. Solid objects in the body of the pump may not prevent its operation but should be removed to prevent damage 4. Inspect inlet and outlet valves for blockages. Clear with finger or screwdriver and test. Screw WARRANTY Whale Pumps are guarenteed for 5 years (1 year on rubber parts) from date of purchase against defects in materials and workmanship. If the unit proves faulty return it to your supplier with proof of purchase and purchase date. The manufacturer retains the right to repair or replace the unit. The manufacturer cannot be held responsible for claims arising from the incorrect installation, unauthorisd modification or misuse of the product. The above does not affect your satutory rights. Bridge piece Valve Inspection: Regular inspection of the pump is recommended. Rubber components should be replaced if worn or every three years regardless of condition. Replacement components and service kits (AK3706 for Neoprene (clean bilge water) and AK3714 for Nitrile (oily bilge water) are available from your local chandlery. It is recommended a service kit is kept on board. Winterising At the end of the season, drain all water in the pipework and pump chamber. Handle knob Tolerance ring Handle Tube Clamping plate Diaphragm Worm Drive Clip Nut Bracket Body Bolt M6 Nut Washer Securing brush Changing the Diaphragm and Valves 1. Slacken and remove the wormdrive clip to release the diaphragm 2. Release diaphragm nut and remove diaphragm plates and diaphragm 3. Replace old inlet and outlet valves. Note: both inlet and outlet valves are same shape. The service kits contain two sets of valves - round ones for the MK 2 pump and square valves for the MK 3 pump. DO NOT mix the valve types! 4. Replace diaphragm and tighten wormclip in position and test for correct priming and discharge Lanyard Buffer Fork liner Fork Locknut Clamping plate Label Fulcrum brush and sleeve Eye Bolt Bolt Screw Gasket Valve plate Fulcrum brush and sleeve Whale and Gusher are registered marks of: Munster Simms Engineering Ltd Washer Old Belfast Road Bangor, Co. Down, N. Ireland, BT19 1LT Tel: 02891 270531 Fax: 02891 466421 info@whalepumps.com Ref No: sr_180.07_0313