LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

Similar documents
COOKSON OWNER'S MANUAL

FDO AU & BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

FDO AU AND BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

OWNER'S MANUAL. MGJ (S-Series) MODEL INDUSTRIAL DUTY DOOR OPERATOR FOR USE WITH SS90 FIRE DOOR CONTROLLER 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE

OWNER'S MANUAL. C2 Wiring SOLID STATE INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE

LMPLC EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE.

OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR 2 YEAR WARRANTY. Serial # (located on electrical box cover) Installation Date.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

OWNER S MANUAL MODEL NO. MEDIUM DUTY JACK SHAFT OPERATOR MDJ, MDJH, MDJB, MDJBH READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS

C2 Wiring 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE. Serial # Box. Installation Date. Wiring Type. See page 7 for other wiring configurations

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B.

LMPLC OWNER S MANUAL MODEL FDCL. B2 Wiring ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

LMPLC OWNER S MANUAL MODEL FDCL ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

MODELS LGO50113R and LGO50113L

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

OWNER'S MANUAL MODEL GH

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

OWNER'S MANUAL J H HJ. C2 Wiring MODELS: LOGIC CONTROL (VER. 2.0) INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE

COOKSON OWNER S MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MODEL K B-360/-500

COOKSON OWNER'S MANUAL

Model JG Industrial Gearhead Jackshaft Door Operator Safety, Installation, and Service Manual

EXTREME R MOTOR OWNER'S MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual

MEDIUM DUTY DOOR OPERATOR MODELS MT5011U & BMT5011U

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MODEL SCA Installation and Operation Manual Important:

SKC400U SLIDING GATE OPENER OWNER S MANUAL

MODEL MG Gearhead Operator

PowerMaster Model SG

INSTALLATION AND OWNER'S MANUAL Model GJ & MGJ Gear Reduced Jackshaft

OWNER'S MANUAL MODEL GH CHOHS Solid State Logic

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

Agri-Fab OWNERS MANUAL. Model No " ROUGH CUT TRAILMOWER. CAUTION: Read Rules for Safe Operation and Instructions Carefully

Roller Door Operator

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K A-600

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

R-BBU BATTERY BACK-UP UNIT INSTRUCTION MANUAL

Installation Instructions

MODEL JH-D DC BATTERY BACK-UP JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL

R-BBU BATTERY BACK-UP UNIT INSTRUCTION MANUAL

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Roll Up Door Operator

OPERATION MANUAL Fire Door Hand Chain Operator Medium (FHCM) & Hand Crank Operator Medium (FHKM)

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Operator

OWNER'S MANUAL MODEL GT

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Door Operator

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

OWNER'S MANUAL. MODELS: J & H CHSJS CHSHS Solid State Logic LOGIC CONTROL (VER. 2.0) INDUSTRIAL DUTY DOOR OPERATOR. C2 Wiring 2 YEAR WARRANTY

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

ANDCO Eagle Actuator Instruction Manual

Provided by: Operating, Maintenance & Parts Manual

Instruction Manual MB4 Rolling garage door opener

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

MJ & MH M-S SERIES JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS with SOLID STATE CONTROLS

HIGH SPEED SLIDING GATE OPENER

GH INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

LED Utility Wrap Fixture

GLM SERIES CONTROL Users Manual Rev:

ELECTRICAL. Contents - Wiring Diagrams

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Use and Care Guide. Item #

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

R3 Roller Garage Door Opener

MO-S SERIES MO-S SERIES SOLID STATE COMMERCIAL

LT Charging Cart for Laptops

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Stevens Type A/F Encoder. For Stand-Alone Encoder Part # AND Encoder Attachment Part # INSTRUCTION 90044

APOLLO Gate Operators, Inc.

750 Series Press Conveyor Installation and Maintenance Manual

LED Recessed Troffer Retrofit Kit

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

SLIDE DOOR OPERATOR ADDENDUM

ISO1000R Service Manual SALES: CUSTOMER SERVICE:

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

PN: 6410T0022 Rev. 8/18/2014 Revision D Albany RR300 Stainless Mechanical Install & Owner s Manual

Installation and Maintenance Manual

Troubleshooting Guide

INSTALLATION AND OWNER S MANUAL

INSTALLATION AND OWNER S MANUAL M50JF & M50JH M-SERIES JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS

Transcription:

COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR LMPLC CONTROL LMPLC CONTROL WIRED B/C Wiring FDO / HP FDO A & B FDO HP FDO A & B YEAR WARRANTY Serial # (located on electrical box cover) NOT FOR RESIDENTIAL USE B6 Installation Date Wiring Type LISTED DOOR OPERATOR

SPECIFICATIONS MOTOR TYPE:...Continuous duty HORSEPOWER:.../ HP HP SPEED:...75 RPM VOLTAGE:...5 Single phase 0/60 Three Phase CURRENT:...5 Volt = 8.A 0/60 Volt =.6/.8A ELECTRICAL TRANSFORMER:...MODEL (A) = VAC, 0 VA MODEL (B) = VAC, 00 VA CONTROL STATION:...NEMA three button station. OPEN/CLOSE/STOP WIRING TYPE:...C (Standard)/B (Optional) To convert to B see pages thru 7. LIMIT ADJUST:...Linear driven, fully adjustable screw type cams. 70 revolutions maximum at limit shaft. MECHANICAL DRIVE REDUCTION / Hp:.56: Reduction In Line Gear Reduced Motor. DRIVE REDUCTION Hp:...56: Reduction In Line Gear Reducer OUTPUT SHAFT SPEED / & Hp :... R.P.M. DOOR SPEED / & Hp:..." per sec. depending on door BRAKE:...Solenoid actuated disc brake. DIMENSIONS FDO A & B / H.P. 5. MOUNTING DIMENSIONS.0.5 8.58 7.00..0.50.00 7.00 6.9.5.50.0.95 DIMENSIONS FDO A & B H.P. MOUNTING DIMENSIONS.0 5. 8.58 5..0.8 8.8. 9.08. 6.50. 6.50 9.50.8

THEORY OF OPERATION GENERAL DESCRIPTION: The Fire Door Operator, FDO-A or FDO-B, is an integrated fire door control system. It is designed to interface with a normally close (NC) or normally open (NO) dry contact alarm system to control the operation of a fire door. The control station is the standard B/C wiring. There are two () models for the FDO: A model: A (AC only) model has no battery backup nor electronic speed control for door's descent. The brake is disengaged when there is no AC power. B model: B (Battery backup) model provides battery backup operations and electronic speed control for door's descent when there is no AC power. The brake is engaged when there is no power.. FDO-A MODEL: Door Descent Speed Control is required for FDO- A model.. UNIT HAS AC POWER & NO ALARM CONDITION: NOTICE THIS OPERATOR IS NOT A FIRE ALARM SYSTEM. IT CAN NOT DETECT A FIRE CONDITION. The B/C control station is used to operate the door electrically. Activation of the safety edge while door is closing will cause it to reverse to full open limit. Activation of safety edge while door is opening will cause it to stop. Activating the optional key-test switch for at least 6 seconds will put the operator in active alarm mode.. UNIT HAS AC POWER & ACTIVE ALARM CONDITION: The warning system (optional) will activate. The door will automatically close after the preset time delay. The time delay is set by means of DIP switches and, (See page ). The door will reverse to full open limit if an obstruction is encountered while closing. The door will automatically close again after the preset time delay. If the obstruction is not cleared, upon the rd attempt to close, the door will stop on the obstruction and activate the warning system (optional) then release the brake. Subsequent obstruction will cause the door to stop for two () seconds then release the brake.. UNIT HAS NO AC POWER: The unit is not functional and the brake is released.

THEORY OF OPERATION CONTINUED. FDO-B MODEL:. BATTERY MANAGEMENT SYSTEM: The battery is charged, tested and monitored automatically by the microprocessor based system. The battery is tested under load every 0 days. If the battery fails this load test then the on-board buzzer will sound for seconds of every minute to indicate that the battery needs to be replaced. If the battery is not replaced within 5 days, the door will activate the warning system (optional) and automatically close and will not allow door to be opened until the battery has been replaced. The door will activate the warning system and automatically close whenever there is not enough backup power in the battery. When this occurs the strobe will flash until the battery is sufficently charged. UNIT HAS AC POWER & NO ALARM CONDITION: The B/C control station is used to operate the door electrically. Activation of the safety edge while door is closing will cause it to reverse to full open limit. Activation of safety edge while door is opening will cause it to stop. Activating the optional key-test switch for at least 6 seconds will put the operator in alarm active mode (see ACTIVE ALARM section for detail operation of alarm active mode).. UNIT HAS AC POWER & ACTIVE ALARM CONDITION: The warning system (optional) will activate. The door will automatically close after the preset time delay. The time delay is set by means of DIP switches and, (See page ). The door will reverse to full open limit if obstruction is encountered while closing. The door will automatically close again after the preset time delay. If the obstruction is not cleared, upon the rd attempt to close, the door will stop on the obstruction and activate the warning system (optional) then release the brake. Subsequent obstruction will cause the door to stop for two () seconds then release the brake. After the rd attempt to close, the integrated braking system controls the door's descending speed.. UNIT HAS NO AC POWER & NO ALARM CONDITION: The CLOSE and STOP buttons of the B/C control station are functional. The door's descending speed is controlled by the integrated braking system. The door will stop if obstruction is encountered while closing. The OPEN button is NOT functional..5 UNIT HAS NO AC POWER & ACTIVE ALARM CONDITION: The warning system (optional) will activate. The door will automatically close after the preset time delay. The time delay is set by means of DIP switches and, (See page ). The door will stop if obstruction is encountered while closing. The door will automatically try to close again after the preset time delay. If the obstruction is not cleared, upon the rd attempt to close, the door will stop on the obstruction and activate the warning system (optional) then release the brake. Subsequent obstruction will cause the door to stop for two () seconds then release the brake.

OPERATOR MOUNTING Before your operator is installed, be sure the door has been properly aligned and is working smoothly. The operator may be wall mounted or mounted on a bracket or shelf. Refer to the illustration and instructions below that suits your application. a. Bracket or Shelf Mounting (Left Hand Shown) The operator may be mounted either above or below the door shaft. The optimum distance between the door shaft and operator drive shaft is between - 5. Refer to Figure. b. Wall Mounting (Left Hand Shown) The operator should generally be installed below the door shaft, and as close to the door as possible. The optimum distance between the door shaft and operator drive shaft is between - 5. Refer to Figure. FIGURE FIGURE c. Place door sprocket on the door shaft. Do not insert the key at this time.. Wrap drive chain around door sprocket and join roller chain ends together with master link.. Raise operator to approximate mounting position and position chain over operator sprocket.. Raise or lower operator until the chain is taut (not tight). Make sure the operator output shaft is parallel to door shaft and sprockets are aligned. When in position, secure the operator to wall or mounting bracket. 5. Align sprockets and secure, (see Figure ). WARNING W FIGURE KEEP DOOR BALANCED. STICKING OR BINDING DOORS MUST BE REPAIRED. DOORS, DOOR SPRINGS, BRACKETS AND THEIR HARDWARE MAY BE UNDER EXTREME TENSION AND CAN CAUSE SERIOUS PERSONAL INJURY. CALL A PROFESSIONAL DOOR SERVICEMAN TO MOVE OR ADJUST DOOR SPRINGS OR HARDWARE. CAUTION 5

ENTRAPMENT PROTECTION SENSING EDGES (REQUIRED) All types of sensing edges with an isolated normally open (N.O.) output are compatible with your operator. This includes pneumatic edge. If your door does not have a bottom sensing edge and you wish to purchase one, contact the supplier of your operator. The operator has been pre-wired to accept connection of a reversing edge device. Connect the normally open contacts to terminals J-5 and J-6 on the PCB Board. The cut-off switch will de-activate the safety device during the last few inches of the door's downward travel. Important Notes: a) Proceed with Limit Switch Adjustments before making any sensing edge wiring connections to operator as described below. b) Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. c) See safety edge coil cord/ take-up installation instructions for details IT IS STRONGLY RECOMMENDED THAT A SENSING EDGE OR OTHER ENTRAPMENT PROTECTION DEVICE BE USED IN CONJUNCTION WITH THIS OPERATOR. WIRING: For wiring of your sensing device to the operator, refer to the wiring diagram supplied with your operator. See field connection terminals identified as Sensing Device or Safety Edge. NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. 6

LIMIT SWITCH ADJUSTMENT MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS.. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts.. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator.. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening.. Repeat Steps and for close cycle. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. If other problems persist, call our toll-free number for assistance - -800-9-58 CLOSE Limit Switch OPEN Limit Switch Actuator Retaining Plate RPM Board SAFETY (Aux. Close) Limit Switch Rotator Cup BRAKE ADJUSTMENT The brake is adjusted at the factory and should not need additional adjustment for the the life of the friction pad. Replace friction pads when necessary. Refer to the illustrations on page 9,, and 5 for identification of components for the solenoid type brake system. BRAKE PAD 7

POWER WIRING CONNECTIONS Remove the cover from the electrical enclosure. Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. 7/8 dia. Control Wiring Access Hole (On Either Side) WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND PERMANENTLY WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. WARNING TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. FDO / H.P. OPERATOR POWER WIRING. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Refer to the operator nameplate on the cover.. Using the 7/8 dia conduit access knockout as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE. IMPORTANT: THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRIC SHOCK AND SERIOUS INJURY. ON THREE PHASE MACHINES ONLY! Incorrect phasing of the power supply will cause the motor to rotate in the wrong direction (open when CLOSE button is pressed and vice-versa). To correct this, interchange any two of the incoming three phase power lines. 7/8 Dia. Power Wiring Access Hole (On Either Side) FDO H.P. OPERATOR 7/8 dia. Control Wiring Access Hole (On Either Side) 7/8 Dia. Power Wiring Access Hole (On Either Side) 8

INSTALL CONTROL STATION Before installing control station be sure to follow all warnings described below. Failure to do so may result in severe injury to persons and/or damage to operator. Do not install any wiring or attempt to run the operator without consulting the wiring diagram. Install the Reversing Edge before proceeding with the Control Station installation. IMPORTANT SAFETY NOTES WARNING INSTALL THE CONTROL STATION WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. WARNING TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. SECURE LOCK(S) IN "OPEN" POSITION. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. WARNING CONTROL STATION WIRING Refer to Control Connection Diagrams on pages & 8. Make connection through hole labeled for control. Do not run control wires in the same conduit as power wires. CABLE CONNECTION NOTE: Be sure to use the control box opening with the 7/8 dia. knockout for CONTROL cable(s). All power wires use the -/6 dia. knockout. MOUNT WARNING NOTICE IMPORTANT: Mount WARNING NOTICE beside or below the push button station. Control Station DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND CONNECTED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. Push Buttons WARNING TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR WARNING Notice. Complete electrical connections to the operator and the control station. Fasten the control station to the wall and MOUNT THE WARNING NOTICE BESIDE OR BELOW THE PUSH BUTTON STATION.. Apply power to the operator. Press OPEN push button and observe direction of door movement and then Press the STOP button. If door did not move in the correct direction, check for improper wiring at the control station or between operator and control station. If the operator is three phase and control station wiring is correct, exchange any two of the three incoming power leads. If electrical problems persist, call our Toll Free number for assistance (-800-58-806). 9

MAINTENANCE SCHEDULE Check at the intervals listed in the following chart. EVERY EVERY EVERY ITEM PROCEDURE MONTHS 6 MONTHS MONTHS Drive Chain Check for excessive slack. Check & adjust as required. Lubricate.* Sprockets Check set screw tightness Fasteners Check & tighten as required Bearings & Shafts Check for wear & lubricate Use SAE 0 Oil (Never use grease or silicone spray). Repeat ALL procedures. Do not lubricate motor. Motor bearings are rated for continuous operation. Inspect and service whenever a malfunction is observed or suspected. CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER - -800-58-806 HOURS 7:00 TO :0 p.m. (Mountain Std. Time) MONDAY Through SATURDAY WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Electronic Parts & Service Dept. 0 N. Forbes Blvd., Suite 0 Tucson, AZ 8575 0

STANDARD POWER & CONTROL CONNECTION DIAGRAMS LMPLC Board - 5V PH LMPLC Board - 0V, 60V PH

OPTIONAL CONTROL SETTINGS NOTE: All functions are independent of each other and do not require other control settings to be set at any certain configuration. SWITCH IS NOT USED BUT MUST BE SET IN THE OFF POSITION IN ORDER FOR THE OPERATOR TO WORK PROPERLY. For dip switch location refer to illustration on next page. ALARM DELAY TO CLOSE S, and S, set the Alarm Delay to Close time of the operator. Alarm Delay to Close is the time between when the operator first receives an active alarm signal and the door starts to close. Refer to illustrations below for various settings. ON 0 SECOND DELAY 0 SECOND DELAY ON OFF OFF 5 SECOND DELAY 60 SECOND DELAY ON ON OFF OFF FIRE ALARM SYSTEM Select the alarm system being used. If the alarm is a normally open system then S, must be off. If the alarm is a normally close system then S, must be on. ON N.O. ALARM ON N.C. ALARM OFF OFF

PCB BOARD ILLUSTRATION DIP SWITCH (S) TERMINAL BLOCK (J) TERMINAL BLOCK (J) HEAT SINK

PHASE WIRING DIAGRAM (FDO50A) 9 Note: ) See Owner s Manual for Dip Switch Functions and Programming Procedures ) TO REVERSE MOTOR DIRECTION: REVERSE PURPLE AND GRAY MOTOR WIRES. ) For B Wiring Remove One End of Jumper from J- and Connect to J-6.

PHASE WIRING DIAGRAM (FDO50B) 95 Note: ) See Owner s Manual for Dip Switch Functions and Programming Procedures ) TO REVERSE MOTOR DIRECTION: REVERSE PURPLE AND GRAY MOTOR WIRES. ) For B Wiring Remove One End of Jumper from J- and Connect to J-6. 5

PHASE WIRING DIAGRAM (FDO0A & FDO0A) 96 Note: ) See Owner s Manual for Dip Switch Functions and Programming Procedures ) TO REVERSE MOTOR DIRECTION: REVERSE PURPLE AND GRAY MOTOR WIRES. ) For B Wiring Remove One End of Jumper from J- and Connect to J-6. 0V - PH MOTOR CONNECTION 5 6 7 8 9 (BN) (GY) (PU) (YE) 60V - PH MOTOR CONNECTION 7 8 5 9 6 (BN) (GY) (PU) (YE) (BN) (BN) INTERNAL MOTOR CONNECTIONS 6

PHASE WIRING DIAGRAM (FDO0B & FDO0B) 97 Note: ) See Owner s Manual for Dip Switch Functions and Programming Procedures ) TO REVERSE MOTOR DIRECTION: REVERSE PURPLE AND GRAY MOTOR WIRES. ) For B Wiring Remove One End of Jumper from J- and Connect to J-6. 0V - PH MOTOR CONNECTION 5 6 7 8 9 (BN) (GY) (PU) (YE) 60V - PH MOTOR CONNECTION 7 8 5 9 6 (BN) (GY) (PU) (YE) (BN) (BN) INTERNAL MOTOR CONNECTIONS 7

REPAIR PARTS KITS FDO50B Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 0 for all repair part ordering information. K-FDO50EB ELECTRICAL BOX KIT E E E E E5 E6 E7 E8 E9 E0 E E E E E5 E6 E7 79-506- 09D08 0-5 0-5- 0-58 0-699 -0-5-00 9-CU50E85 9-NP7 9-R50B7KWR 5-0 -0 50-788 75-705 79-9 80-75 RPM Board RPM Housing Electrical Box Cover Electrical Box Battery Top Plate Battery Strap Transformer, 00VA Overload, 0 AMP Capacitor Battery, V Power Resistor Fuse, AMP 0 Pole Terminal Block Voice Board Standoff Assembly, FDO PCB PCB, LMPLC Assembly Bracket, Resistor 7 K75-58 BRAKE ASSEMBLY KIT B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 B7 0-090 0-09 0-55 0-56 0-57 0-59 -09-09 8-09 9-800 -08-086 75-077 75-57 75-58 86-CP0-0-679 Brake Release Lever Brake Disc Brake Cover Extension Bracket Plate, DC Solenoid Solenoid Cover Spring Cup Brake Stud Spring, Brake Chain, #8 x Pitch DC Solenoid Standoff Brake Hub Assembly Pressure Plate Assembly Mounting Bracket Assembly Cotter Pin, /8 x -/ Stop, DC Solenoid * Electrical Box Kits include parts from K7-580 and K75-86 K75-58 MOTOR KIT M M M 5-987 0-500 80-07- Dual Sprocket, 8B9 and 50B9 Motor, VW0 Key, /6 x Long K7-580 LIMIT SHAFT ASSEMBLY KIT L L L L L5 L6 L7 L8 09-70 -6-008 -00 5-8B9A 80-005 86-RP0-00 87-E-08 Rotator Cup Limit Shaft Flange Bearing Limit Nut Sprocket, #8B9 x /8 Bore Washer, Spacer Roll Pin, /8 x long E-Ring, /8 K79-9 PCB, LMPLC ASSEMBLY KIT E6 79-9 PCB, LMPLC Assembly K75-86 LIMIT SWITCH ASSEMBLY KIT S S S S S5 S6 S7 S8 S9 0-00 0-55 0-806 8-006 -00-5 8-PX0-0 8-PX06-6 8-LH-06 Depress Plate Nut Plate Switch Backup Plate Spring, Depress Limit Switch Standoff, Switch Screw, #-0 Pan Head Screw, #6- Pan Head Lock Nut, #6- K7-67 RPM SENSOR ASSEMBLY KIT E E 79-506- 09D08 RPM Board RPM Housing K7-68 POWER RESISTOR ASSEMBLY KIT E9 E 9-CU50E85 9-R50B7KWR Capacitor Power Resistor 6 8

ILLUSTRATED PARTS FDO50B 9 E E0 E6 E E E E E8 E E7 L L L L L7 L5 L6 S5 S6 S S S7 B B B S S9 E7 B B9 B8 S8 S E E9 L L6 L8 L E E5 E5 E6 B7 B B B6 B7 B B5 B0 B6 B M M M B5

REPAIR PARTS KITS FDO50A Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 0 for all repair part ordering information. K-FDO50A ELECTRICAL BOX KIT E E E E E5 E6 E7 E8 E9 0-5 0-5 0-58 -55 5-00 -0 50-788 75-75 79-9 Electrical Box Cover Electrical Box Battery Top Plate Transformer, 0VA Overload, 0 AMP 0 Pole Terminal Block Voice Board (Optional) Standoff Assembly, FDO PCB PCB, LMPLC Assembly * Electrical Box Kits include parts from K7-58 and K75-86 K75-58 MOTOR KIT M M M 5-987 0-500 80-07- Dual Sprocket, 8B9 and 50B9 Motor, VW0 Key, /6 x Long 7 K75-76 BRAKE ASSEMBLY KIT B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 B7 B8 B9 B0 0-09 0-55 0-55 0-56 0-59 -56-57 -58-59 8-09 8-550 9-800 -08 75-077 75-57 75-58 8-PX06-06T 86-CP0-0-57 0-679 Brake Disc Brake Release Lever Brake Cover Extension Bracket Solenoid Cover Spring Cup Spring Cap Brake Stud Standoff Spring, Compression Spring, Compression Chain, #8 x Pitch DC Solenoid Brake Hub Assembly Pressure Plate Assembly Mounting Bracket Assembly Screw, #6- Pan Head Cotterpin, /8 x -/ Plate, DC Solenoid Stop, DC Solenoid K7-58 LIMIT SHAFT ASSEMBLY KIT L L L L L5 L6 L7-6 -008-00 5-8B9A 80-005 86-RP0-00 87-E-08 Limit Shaft Flange Bearing Limit Nut Sprocket, #8B9 x /8 Bore Washer, Spacer Roll Pin, /8 x long E-Ring, /8 K75-86 LIMIT SWITCH ASSEMBLY KIT S S S S S5 S6 S7 S8 S9 0-00 0-55 0-806 8-006 -00-5 8-PX0-0 8-PX06-6 8-LH-06 Depress Plate Nut Plate Switch Backup Plate Spring, Depress Limit Switch Standoff, Switch Screw, #-0 Pan Head Screw, #6- Pan Head Lock Nut, #6-6 K79-9 PCB, LMPLC ASSEMBLY KIT E9 79-9 PCB, LMPLC Assembly 0

ILLUSTRATED PARTS FDO50A E6 E9 E E E8 L L L L L6 L L5 S9 S B5 B6 B8 S8 S B0 B S B7 B B B6 B8 B9 B B7 S7 B B B B B9 M M M B0 B5 S S6 S5 L L7 L5 E E5 E7 E

REPAIR PARTS KITS FDO0B & FDO0B Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 0 for all repair part ordering information. K-FDO0EB & K-FDO0EB ELECTRICAL BOX KIT E E E E E5 E6 E7 E8 E9 E0 E E E E E5 E6 E7 E8 K75-7 MOTOR KIT M M 07-079- 0-00C-T Brake Hub Motor, Hp 0/60V Ph, TEFC K7-580 LIMIT SHAFT ASSEMBLY KIT L L L L L5 L6 L7 L8 79-506- 09D08 0-5 0-5- 0-58 0-699 -55 See Variables 9-CU50E85 9-NP7 9-R50B7KWR 5-0 -0 50-788 75-705 79-9 80-75 5-000-K 09-70 -6-008 -00 5-8B9A 80-005 86-RP0-00 87-E-08 RPM Board RPM Housing Electrical Box Cover Electrical Box Battery Top Plate Battery Strap Transformer, 00VA PT Series Overload Capacitor Battery, V Power Resistor Fuse, AMP 0 Pole Terminal Block Voice Board Standoff Assembly, FDO PCB PCB, LMPLC Assembly Bracket, Resistor Overload Bracket * Electrical Box Kits include parts from K7-580 and K75-86 VARIABLE COMPONENTS E5 5-00-K 5-00-5K Overload. - 5.5 Amp (0V Ph) Overload.6 -.5 Amp (60V Ph) Rotator Cup Limit Shaft Flange Bearing Limit Nut Sprocket, #8B9 x /8 Bore Washer, Spacer Roll Pin, /8 x long E-Ring, /8 K79-9 PCB, LMPLC ASSEMBLY KIT E6 79-9 PCB, LMPLC ASSEMBLY 7 K75-995 BRAKE ASSEMBLY KIT B B B B B5 B6 B7 B8 B9 B0 B B B B B5 0-090 0-09 0-66 0-57 0-67 -09-09 8-09 9-800 -08-086 75-57 75-99 86-CP0-0-679 Brake Release Lever Brake Disc Brake Cover Plate, DC Solenoid Solenoid Cover Spring Cup Brake Stud Spring, Brake Chain, #8 x Pitch DC Solenoid Standoff Pressure Plate Assembly Mounting Bracket Assembly Cotter Pin, /8 x -/ Stop, DC Solenoid K75-86 LIMIT SWITCH ASSEMBLY KIT S S S S S5 S6 S7 S8 S9 0-00 0-55 0-806 8-006 -00-5 8-PX0-0 8-PX06-6 8-LH-06 Depress Plate Nut Plate Switch Backup Plate Spring, Depress Limit Switch Standoff, Switch Screw, #-0 Pan Head Screw, #6- Pan Head Lock Nut, #6- INDIVIDUAL COMPONENTS 5 6 0-6 0-6 0-65 5-650 -0 80-097 Electrical Box Mounting Bracket Shim, Gear Reducer Electrical Box Mounting Bracket Dual Sprocket Gear Reducer, 56: Key, / x Long K7-67 RPM SENSOR ASSEMBLY KIT E E 79-506- 09D08 RPM Board RPM Housing K7-68 POWER RESISTOR ASSEMBLY KIT E9 E 9-CU50E85 9-R50B7KWR Capacitor Power Resistor 6

ILLUSTRATED PARTS FDO0B & FDO0B E0 E E E7 L L L L L7 E6 E E L5 L6 S5 S6 S S S7 B5 M B0 S S9 E7 M 6 5 B B B B B B6 B8 B7 B B B9 B5 S8 S B E E9 L L6 E8 E8 L8 L E E E5 E5 E6 E

REPAIR PARTS KITS FDO0A & FDO0A Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page 0 for all repair part ordering information. K-FDO0A & K-FDO0A ELECTRICAL BOX KIT E E E E E5 E6 E7 E8 E9 E0 0-5 0-5 0-58 See Variables See Variables -0 50-788 75-75 79-9 5-000-K Electrical Box Cover Electrical Box Battery Top Plate Transformer Overload 0 Pole Terminal Block Voice Board (Optional) Standoff Assembly, FDO PCB PCB, LMPLC Assembly Overload Bracket * Electrical Box Kits include parts from K7-58 and K75-86 VARIABLE COMPONENTS E E5 B -50-560 5-00-K 5-00-5K -0- -60- Transformer, 0 Volt Transformer, 60 Volt Overload. - 5.5 Amp (0V Ph) Overload.6 -.5 Amp (60V Ph) Brake Solenoid, 0V (0V Ph) Brake Solenoid, 60V (60V Ph) K75-7 MOTOR KIT M M 07-079- 0-00C-T Brake Hub Motor, Hp 0/60V Ph, TEFC 7 K75-998 & K75-5006 BRAKE ASSEMBLY KIT B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 B7 B8 0-09 0-55 0-66 0-67 -56-57 -58-59 8-09 8-550 9-800 -08 75-57 75-997 8-PX06-06T 86-CP0-0-57 0-679 Brake Disc Brake Release Lever Brake Cover Solenoid Cover Spring Cup Spring Cap Brake Stud Standoff Spring, Compression Spring, Compression Chain, #8 x Pitch DC Solenoid Pressure Plate Assembly Mounting Bracket Assembly Screw, #6- Pan Head Cotterpin, /8 x -/ Plate, DC Solenoid Stop, DC Solenoid K75-86 LIMIT SWITCH ASSEMBLY KIT S S S S S5 S6 S7 S8 S9 0-00 0-55 0-806 8-006 -00-5 8-PX0-0 8-PX06-6 8-LH-06 Depress Plate Nut Plate Switch Backup Plate Spring, Depress Limit Switch Standoff, Switch Screw, #-0 Pan Head Screw, #6- Pan Head Lock Nut, #6-6 K7-58 LIMIT SHAFT ASSEMBLY KIT L L L L L5 L6 L7-6 -008-00 5-8B9A 80-005 86-RP0-00 87-E-08 Limit Shaft Flange Bearing Limit Nut Sprocket, #8B9 x /8 Bore Washer, Spacer Roll Pin, /8 x long E-Ring, /8 INDIVIDUAL COMPONENTS 5 6 0-6 0-6 0-65 5-650 -0 80-097 Electrical Box Mounting Bracket Shim, Gear Reducer Electrical Box Mounting Bracket Dual Sprocket Gear Reducer, 56: Key, / x Long K79-9 PCB, LMPLC ASSEMBLY KIT E9 79-9 PCB, LMPLC Assembly

ILLUSTRATED PARTS FDO0A & FDO0A E6 E9 E E8 L L L L E L6 L L5 S9 S B S8 S B B7 M M 6 5 B B B B5 B6 B9 B B0 B6 B5 B7 B8 B B S7 B8 S E L5 L7 L S5 S6 S E0 E5 E7 E 5

OPERATOR NOTES 6

OPERATOR NOTES 7

CONTROL CONNECTION DIAGRAM B6 IMPORTANT NOTES: The -Button Control Station provided must be connected for operation. LISTED DOOR OPERATOR BUTTON STATION OR POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD OR MORE KEY-TEST J 6 7 8 9 0 J 6 7 8 9 0 J 6 7 8 9 0 Open Open Open Open Close Close Close Close Stop Stop Stop Stop Keyswitch SENSING DEVICE TO REVERSE OR STOP ALARM SYSTEM NO OR NC CONTACTS J 5 6 J J Sensing Device NC Contacts Must set DIP switch # (S,) to ON. NO Contacts Must set DIP switch # (S,) to OFF. STROBE LIGHT SPEAKER WIRING J 5 7 TB - + Strobe Light Speaker 0-97A c 00, The Chamberlain Group, Inc. All rights Reserved