Electrical Control Panel

Similar documents
READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Utility Distribution Systems Installation, Operation, and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Self Cleaning Hood System Installation, Operation, and Maintenance Manual

General Description. Product Specification. Document Digital Temperature Interlock

SPC-PANEL Simplex, Single Phase Pump Control Panel

Pump Installation and Service Manual HRS Hydromatic Retractable System

Operators Manual for JES-HD

Installation Manual for Ecology

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

Installation, Operation and Maintenance Manual

Model ND-2 Specification

Installation, Operation and Maintenance Manual

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

KVL-P with Plate Shelf

INSTALLATION & OWNER'S MANUAL

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

RU BMS Power Supply and Battery Management System Owners Guide

When Time Matters! listed Fire Damper

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

DC to AC Power Inverters

DC to AC Power Inverters

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Pro Island Ventilation Hoods

Zoneflow Engineering Installation and Maintenance Manual

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation Instructions for Eaton Surge Protective

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Installation, Operation and Maintenance Manual

Electronically Commutated Motors

Installation Manual. Q Series Quadplex Grinder Systems. Contents

ELECTRONIC FIREPLACE DAMPER

BCFS Belt Driven Centrifugal Filtered Supply Fans

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

MOTORTRONICS Solid State AC Motor Control

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

Special Specification 6058 Battery Back-Up System for Signal Cabinets

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

EZ SDI TM Booster Pump Assembly

WhispAire Range Hood Quiet Hood

Installation, Operation, and Maintenance Manual

Quik-Spec Coordination Panelboard Specifications

12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12

HA/HAB Fiberglass Wall Mount Ventilators

NUTONE RANGE HOOD NTM SERIES

WARRANTY INFORMATION...

Patient Care Facility

Air Curtain. Installation, Operating and Maintenance Instructions

Zoneflow Engineering, Installation, and Maintenance Manual

INSTALLATION MANUAL. Melink Corporation (513) Revision

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

DW Series - Exhaust Only Wall Canopy

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

AXIJET LEADLAG EXHAUST FAN CONTROL SYSTEM

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

WELDING FUME EXHAUSTERS & ARMS

Installation Instructions Central Battery Units

Model C230 Pump Controller

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

BBAIR V Conveyor Dryer

Direct Gas-Fired Heating

OWNERS MANUAL JANUARY 2007 ISO

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

Kitchen Tech Series Air Curtain

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

ADI-125/750 ADI-125/1500 ADI-125/2500

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

MIL-24/2600Q MIL-24/3200DQ

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Patient Care Facility

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

8-12 INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

HP190SL Series Slimline Radon Fans

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

SECTION PANELBOARDS

INSTALLATION AND OPERATIONS MANUAL POWER OPERATED TUBING STORAGE REEL MODEL TSR-P PRODUCTS, INC.

D-Series Blowers and Exhausters

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Manual Transfer Switch

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Transcription:

Electrical Control Panel Kitchen Ventilation Control System Installation and Operations Manual Photo to Come FOR MODELS: ECP Striving for Excellence STREIVOR.COM

Table of Contents General Information Pre-Installation Precautions...3 Electrical Control Panel Drawing Sample...3 Electrical Control Panel: Hood Mounted...4 Electrical Control Panel: Wall Mounted...4 Installation Procedures Control Circuit Input Power Wiring...5 Motor Circuit Input Power Wiring (ECP with Motor Starters)...5 Motor Circuit Output Power Wiring (ECP with Motor Starters)...5 Overload Setting (ECP with Motor Starters)...5 Fan Control Signal Wiring (ECP without Motor Starters)...6 Fan Switch Wiring (Remote Fan Switch Not Provided by Streivor)...6 Light Switch Wiring (Remote Light Switch Not Provided by Streivor)...6 Fan Switch Wiring (Fan Switch Provided by Streivor)...7 Light Switch Wiring (Light Switch Provided by Streivor)...7 Light Power Circuit Wiring for Hoods with Fire Suppression Systems (FSS)...8 Internal Hood Fan (IHF) Circuit Wiring for SmartAire Technology Hoods...8 Fire Suppression System (FSS) Switch Circuit Wiring...9 Hood Canopy and/or Duct Collar Temperature Monitor Wiring (Temperature Monitor Provided by Streivor)... 9-10 Shunt Trip Breaker Wiring (Optional Method)...10 Operation Procedures Start Up...11 Fan Switch...11 Light Switch...11 Temperature Monitor (Temperature Monitor Provided by Streivor)...11 Temperature Monitor Set Point Adjustment (Temperature Monitor Provided by Streivor)... 11-12 Warranty Warranty Information...13 2

General Information Pre-Installation Precautions WARNING PRIOR TO MAKING ANY ELECTRICAL CONNECTIONS TO THE ELECTRICAL CONTROL PANEL (ECP), READ AND UNDERSTAND THIS ENTIRE INSTALLATION AND OPERATIONS MANUAL. ALL WORK ON THE ECP SHOULD BE PERFORMED BY QUALIFIED CONTRACTORS IN ACCORDANCE WITH ALL APPLICABLE PREVAILING CODES AND STANDARDS. THE ECP HAS MULTIPLE ELECTRICAL CONNECTIONS. VERIFY THAT ALL POWER HAS BEEN DISCONNECTED TO THE ECP PRIOR TO WORKING ON OR NEAR THE ECP. LOCK OUT / TAG OUT ALL OF THE DISCONNECT SWITCHES OR CIRCUIT BREAKERS TO PREVENT ACCIDENTAL POWER UP. ALL ELECTRICAL WIRING AND CONNECTIONS TO THE ECP SHALL BE IN ACCORDANCE WITH THE PREVAILING CODES, THE NATIONAL ELECTRICAL CODES, AND ANSI/NFPA70. VERIFY THAT THE SERIAL NUMBER ON THE WIRING DIAGRAM (SEE SAMPLE DRAWING BELOW) PROVIDED WITH THE ECP MATCHES THE SERIAL NUMBER OF THE ECP BEFORE USING THE WIRING DIAGRAM FOR REFERENCE. VERIFY THAT THE VOLTAGE AND WIRE AMPERAGE CAPACITY AND WIRE INSULATION IS IN ACCORDANCE WITH THE CONTROL PANEL NAMEPLATE. Electrical Control Panel Drawing Sample Fan Motor Power Specifications Field Wiring Diagram Serial Number Installation Details Equipment Layout 3

General Information Electrical Control Panel: Hood Mounted Exhaust Duct Hood Duct Collar Access Enclosure with Temperature Monitor (optional) Rear Standoff Hood Light Power J-Box SmartAire Internal Hood Fan Power J-Box (optional) Hood Duct Collar Hood Light Fixture J-Box SmartAire Internal Hood Fan J-Box (optional) Hood Canopy Hood Canopy Mounted Access Enclosure with Temperature Monitor (optional) Temperature Monitor J-Box (optional) Factory Mounted Electrical Control Panel in Hood Utility Cabinet Cabinet Mounted Illuminated Fan and Light Switches (optional) Electrical Control Panel: Wall Mounted Exhaust Duct Hood Duct Collar Access Enclosure with Temperature Monitor (optional) Rear Standoff Hood Light Power J-Box SmartAire Internal Hood Fan Power J-Box (optional) Wall Mounted Electrical Control Panel Remote Fan and Light Switches (Not Provided by Streivor) Hood Duct Collar Hood Light Fixture J-Box SmartAire Internal Hood Fan J-Box (optional) Hood Canopy Hood Canopy Mounted Access Enclosure with Temperature Monitor (optional) Temperature Monitor J-Box (Optional) Hood Mounted Illuminated Fan and Light Switches (Optional) 4

Control Circuit Input Power Wiring Streivor Electrical Control Panel Operations Manual Installation Procedures a. Verify that all supply power to the control panel is locked out and tagged out. b. Verify that the circuit breaker amperage is sized correctly for the control circuit per the Electrical Control Panel (ECP) drawings. c. Connect 120 VAC single phase power to the terminal blocks in the control panel labeled H, N, and G (Figure 1). d. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. FIGURE 1: Control Circuit Input Power Motor Circuit Input Power Wiring (ECP with Motor Starters) b. Verify that the circuit breaker amperage is sized correctly for each motor input power circuit. c. Verify that the voltage and phase of each motor circuit is correct per the ECP drawings. d. Connect input power to the input power terminal blocks as shown on the ECP drawings. e. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. Motor Circuit Output Power Wiring (ECP with Motor Starters) b. The output terminals located on the Motor Starter(s) have been pre-wired to the designated output power terminal blocks in the control panel. Connect the output power terminal blocks to the designated fan motor(s) as shown on the ECP drawings. c. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. Overload Setting (ECP with Motor Starters) a. Verify that all power to the control panel is locked out and tagged out. b. Verify that each overload has been set to 125% of the full load amps displayed on the corresponding motor nameplate. c. The overload setting can be adjusted as needed by rotating the dial to the desired amperage value (Figure 2). Overload Setting Dial FIGURE 2: Motor Starter (If Provided by Streivor) 5

Installation Procedures Fan Control Signal Wiring (ECP without Motor Starters) a. Connect the terminal blocks in the control panel designated for the start/stop fan control signals to the appropriate external destination Motor Starter(s) (by others) or Building Management System (BMS). b. Refer to the EPC drawings for more information on the control signals available (24 VDC, 120 VAC, or Dry Contact). c. The wires should be torqued to 0.6-0.8 N m at the terminal blocks. Fan Switch Wiring (Remote Fan Switch Not Provided by Streivor) b. Connect 120 VAC from terminal block 1 in the ECP to the line terminal of the remote fan switch. c. Connect the load terminal of the remote fan switch to terminal block 2 in the ECP (Figure 3). d. The wires should be torqued to 1.5 1.8 N m at the terminal blocks. FIGURE 3: Fan Switch Wiring Light Switch Wiring (Remote Light Switch Not Provided by Streivor) b. Connect 120 VAC from terminal block 9 in the ECP to the line terminal of the remote light switch. c. Connect the load terminal of the remote light switch to terminal block 10 in the ECP (Figure 4). d. The wires should be torqued to 1.5 1.8 N m at the terminal blocks. FIGURE 4: Light Switch Wiring 6

Installation Procedures Fan Switch Wiring* If included, the illuminated fan switch(es) provided by Streivor may be pre-wired when installed on the front of the hood or hood utility cabinet. b. Connect 120 VAC from terminal block 1 in the ECP to the line terminal of the fan switch (Figure 5A). c. Connect the load terminal of the fan switch to terminal block 2 in the ECP (Figure 5A). d. Connect the green terminal on the fan switch to ground in the ECP to allow the switch to illuminate when turned on (Figure 5). e. The wires should be torqued to 1.5 1.8 N m at the terminal blocks. Load Terminal Line Terminal Ground Terminal (for Switch Illumination) Light Switch Wiring* FIGURE 5A: Fan Switch Wiring* If included, the illuminated light switch(es) provided by Streivor may be pre-wired when installed on the front of the hood or hood utility cabinet. b. Connect 120 VAC from terminal block 9 in the ECP to the line terminal of the light switch (Figure 5B). c. Connect the load terminal of the light switch to terminal block 10 in the ECP (Figure 5B). d. Connect the green terminal on the light switch to ground in the ECP to allow the switch to illuminate when turned on (Figure 5B). e. The wires should be torqued to 1.5 1.8 N m at the terminal blocks. Load Terminal Line Terminal Ground Terminal (for Switch Illumination) FIGURE 5B: Light Switch Wiring* *Fan and Light Switches Provided by Streivor 7

Installation Procedures Light Power Circuit Wiring for Hoods with Fire Suppression Systems (FSS) b. There are two options regarding light circuit wiring for hoods with fire suppression systems. i. To allow power to lights to remain connected upon a fire suppression system activation, connect 120 VAC single phase power from terminal block 11 (hot), terminal block 12 (neutral), and ground in the control panel to the wires labeled Lights in the junction box on the hood (Figure 6). ii. To allow power to lights to automatically disconnect upon a fire suppression system activation, connect 120 VAC single phase power from terminal block 13 (hot), terminal block 14 (neutral), and ground in the control panel to the wires labeled Lights in the junction box on the hood (Figure 7). c. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. FIGURE 6: Light Power Circuit: Lights On During a FSS Activation FIGURE 7: Light Power Circuit: Lights Off During a FSS Activation Internal Hood Fan (IHF) Circuit Wiring for SmartAire Technology Hoods Per NFPA 96 Section 8.3.2: When its fire-extinguishing system discharges, makeup air supplied internally to a hood shall be shut off. b.connect 120 VAC single phase power from terminal block 3 (hot), terminal block 4 (neutral), and ground in the control panel to the wires labeled IHF in the junction box on each hood (Figure 8). c. Internal Hood Fan power to terminal blocks 3 and 4 will be automatically shunt during a fire suppression system activation to comply with NFPA 96 Section 8.3.2. d. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. FIGURE 8: Internal Hood Fan Circuit 8

Installation Procedures Fire Suppression System (FSS) Switch Circuit Wiring b. Locate the FSS switch in the FSS Control Panel. The FSS Switch (also referred to as microswitch) shall have one set of single-pole-double-throw contacts. c. Connect the terminal blocks in the control panel to the FSS Switch(es) (Figure 9A). The building alarm circuit must be connected to the switch with lugs (Figure 9B). d. Refer to the ECP drawings for more detail regarding wiring additional FSS switches. e. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. Terminal Blocks Allocated for: Shunt Trip Building Alarm Spare Spare { { { { FSS Switch with Lugs for Building Alarm Circuits FIGURE 9A: Fire Suppression System (FSS) Switch Circuits FIGURE 9B: FSS Switch for Building Alarm Hood Canopy and/or Duct Collar Temperature Monitor Wiring* IMC 507.2.1.1 Operation. Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. b. Connect 120 VAC single phase control power from terminal block 7 (hot), terminal block 8 (signal), and ground in the ECP to the wires labeled Temp in the junction box on the hood closest to the ECP (Figure 10A). c. For systems with multiple hoods, perform step b. and connect the temperature monitor circuits from each additional hood to allow any temperature monitor on any hood to automatically activate the start signal for the fan(s) (Figure 10B). d. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. Figure 10A: Temperature Monitor Wiring* *Temperature Monitor Provided by Streivor 9

Installation Procedures Hood Canopy and/or Duct Collar Temperature Monitor Wiring* (Continued) Figure 10B: Temperature Monitor Wiring for Multiple Hoods* Shunt Trip Breaker Wiring (Optional Method) Per NFPA 96 Section 10.4.1: Upon activation of any fire-extinguishing system for a cooking operation, all sources of fuel and electrical power that produce heat to all equipment requiring protection by that system and all electrical outlets located under the exhaust hood shall automatically shut off. b. Terminal block 71 can be used to provide power to a shunt trip device to comply with NFPA 96 Section 10.4.1. Terminal block 71 provides 120 VAC power upon fire suppression system activation (Figure 11). c. The wires should be torqued to 1.5-1.8 N m at the terminal blocks. FIGURE 11: Shunt Trip Wiring (Optional Method) *Temperature Monitor Provided by Streivor 10

Operation Procedures Start Up 1. Apply power to the Electrical Control Panel CONTROL circuit via the appropriate circuit breaker protecting the ECP. a. Verify that 120 VAC is applied between terminal blocks H and N. 2. If the control panel includes Motor Starter(s), apply power to the MOTOR circuits via the appropriate circuit breakers protecting the fan motors. a. Verify that the specified fan motor power is applied to incoming power terminal blocks of each corresponding Motor Starter(s). b. Refer to the ECP drawings for voltage, phase, and designated terminal blocks for each fan motor. Fan Switch The Fan Switch can be used to manually turn the fan(s) controlled by the ECP on or off. Fan Switches provided by Streivor can be wired to illuminate when turned on. WARNING NOTE: HOOD(S) WHICH INCLUDE TEMPERATURE MONITOR(S) MAY AUTOMATICALLY TURN THE FAN(S) CONTROLLED BY THE ECP ON EVEN IF THE FAN SWITCH IS TURNED OFF. Light Switch The Light Switch can be used to manually turn the hood light(s) controlled by the ECP on or off. Light Switches provided by Streivor can be wired to illuminate when turned on. Temperature Monitor* Hood(s) which include Temperature Monitor(s) will automatically turn on the fan(s) controlled by the ECP once the adjustable set point of at least one Temperature Monitor has been reached. The fan(s) will remain on, under normal operation, until the temperature below the hoods has decreased below the set points of all of the Temperature Monitors. Temperature Monitor Set Point Adjustment* Each Temperature Monitor has an adjustable temperature set point. The set point(s) have been preset by the factory; however, depending on field conditions and cooking appliances below the hoods, further adjustment may be necessary in the field to maintain normal operation. In most cases, the recommended temperature set point is aproximately 5 F 15 F above the average ambient temperature in the kitchen space. For example, if the ambient temperature in the kitchen space is 75 F, the Temperature Monitor set point can be adjusted to approximately 80 F 90 F. Each Temperature Monitor can be accessed from below the hood via a UL Listed access enclosure. The access enclosure and Temperature Monitor may be located in the hood canopy and/or behind the grease filters against the top of the exhaust plenum near the exhaust duct collar. *Temperature Monitor Provided by Streivor 11

Operation Procedures Temperature Monitor Set Point Adjustment* (Continued) To perform a temperature set point adjustment for a Temperature Monitor: a. Verify that all power to the control panel is locked out and tagged out and verify that the Temperature Monitor circuit is unpowered. b. Locate the access enclosure and Temperature Monitor (Figure 12A). c. Remove the screws and remove the access enclosure and Temperature Monitor, being careful not to pull on the wires connected to the Monitor (Figure 12B). Figure 12A: Temperature Monitor Access Enclosure* (Hood Canopy Mounted Temperature Monitor Shown) Figure 12B: Temperature Monitor Housing* d. Remove the screw on the Temperature Monitor assembly, then remove the cover to allow access to the temperature set point dial inside (Figure 12C). Figure 12C: Temperature Monitor Set Point Dial* e. The temperature set point dial can be adjusted by hand by rotating the dial to the appropriate set point desired as indicated by the steel pin. f. Replace the Temperature Monitor cover and reinstall the Temperature Monitor assembly. g. Repeat as necessary for additional Temperature Monitors. *Temperature Monitor Provided by Streivor 12

Warranty Streivor, Inc., (Seller), warrants this equipment to be free from defects in materials and workmanship, under normal use and service, for the period of 18 months from the date of shipment. This warranty shall not apply if: 1. The equipment is not installed by a qualified installer per the Seller s installation instructions (copy of which is shipped with the product). 2. The equipment is not installed in accordance with federal, state and local codes and regulations by a qualified installer. 3. The equipment is misused or neglected. 4. The equipment is not operated within its published capacity. The Seller shall not be liable for incident and consequential losses and damages potentially attributed to malfunctioning equipment. Should any part of the equipment prove to be defective in material or workmanship within the 18 months warranty period, upon examination by the Seller, such part will be repaired or replaced by Seller at no charge. The Buyer shall pay all labor costs incurred in connection with such repair or replacement. Equipment shall not be returned without Seller s prior authorization and all returned equipment shall be shipped by the Buyer, F.O.B. Seller s factory, freight prepaid. 13

The ULTIMATE In Kitchen Ventilation Systems SmartAire Hoods The Ultimate in Energy Efficient Hood Design US Patent No. 8,857,424 ExtractAire The Ultimate Adjustable High Velocity Cartridge Filter US Patent No. 6,394,083 BalanceAire The Ultimate Hood Balancing Damper US Patent No. D634,419 DemandAire The Ultimate in Demand Ventilation Systems Enclosures The Ultimate Enclosures for the Protection of Hood and Duct Monitoring Equipment Monitors The Ultimate in Hood and Duct Monitoring Controls Striving for Excellence www.streivor.com 2150 Kitty Hawk Road, Livermore, CA 94551 Phone: (925) 960-9090 Fax: (925) 960-9055 Copyright 2016 Streivor Inc. All Rights Reserved. Utility Cabinet Systems The Ultimate in Modular Utility Cabinets 01.2016 Copyright 2016 Streivor, Inc.