Model ED 400 Drying and heating chambers Classic.Line with natural convection

Similar documents
Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Heating oven with mechanical control

Heating oven with natural convection

Safety drying ovens. Advantages: Areas of application: FDL series 115

Heating chamber with mechanical convection

Heating oven with mechanical convection

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

Heating chamber with mechanical convection

Refrigerated incubator with Peltier technology

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

Climate chambers with illumination

Climate chamber with illumination

Safety drying ovens with expanded temperature range

Safety drying oven with expended temperature range

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

MDL series Safety drying ovens with first class safety features and an expanded temperature range

MK MKF MKT MKFT Environmental simulation chambers

Dynamic climate chambers. MK MKF MKT MKFT series

Environmental simulation chambers MK MKF MKT MKFT

FUNCTION LINE HEATING AND DRYING OVENS

Cooled incubators (ST), laboratory refrigerators

BAC 55. Specifications and optional equipment. Outer dimensions in mm 600 W x 500 D x 580 H Inner dimensions in mm 415 W x 315 Dx 410 H Volume

Liquid Nitrogen Storage Solution. Extra large LCD and cryogenic intelligent management establishing new standards of global

Laboratory refrigerators

INCUBATORS I PAGE 4-8. COMPRESSOR-COOLED INCUBATORS ICPeco PAGE COMPRESSOR-COOLED INCUBATORS ICP PAGE 19-20

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

GMP dry heat ovens for depyrogenisation and sterilisation

BASIC LINE. LAB Freezers & Refrigerators

Flash Point Process Analyzer

Ovens. UL Certified Ovens WON, WOF & WOV models. WiseVen. High-Clean Air Ovens

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

PCR Laminar Flow Cabinets

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

WATERBATHS WNB, WNE, WPE PAGE 4-9 OILBATHS ONE PAGE ADDITIONAL INFORMATION PAGE 14

GENERAL PURPOSE INCUBATOR

UFlex Storage System. Anodized aluminum. Thermal plastic bumper. A wealth of possible combinations STORAGE

Bench Centrifuge or Bench Centrifuge with Trolley

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

CFPP Process Analyzer

Incubators. Incubators

RALF At a glance. Bioengineering RALF essentials. General

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

Boekel Complete Culture Control Incubators

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

Optidew Vision Optical Dew-Point Meter

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

Humidity Cabinet HYGROTHERM

Integrated temperature test and calibration bench Model CBS-SC4000

task & ergonomic Century Task

Instruments for the Analysis of Petroleum Products. Oxidation Stability

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

Zwick. Materials testing. Product Information Temperature chambers for AllroundLine

END OF YEAR WAREHOUSE CLEARANCE SALE! Ex Demo & Superseded Instrumentation

Refrigerators/Freezers

Cyclic Corrosion Test CORR Series

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

Guth modulating valves. The sophisticated solution

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

FPA4 DATASHEET JUNHO 2013

Industries: Aerospace. Optical Electronics ASTM Test Ovens. Automotive. Automotive Components. Petroleum Curing Ovens. Ceramics

Our test laboratory - Apparatebau Kirchheim-Teck GmbH

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

Power Conversion System The Best Technology for your photovoltaic and storage system

Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Product Data Sheet 632 NU-006

Thermo Scientific TSX Series Ultra-Low Freezers

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Nexa 1200 Fuel Cell System

Dehydrators - Technical Characteristics and Pricelist

Low and High Voltage Power Supplies

Digital incubating/ refrigerating benchtop shakers.

Cyclic Corrosion Chamber C.C.T AUTO Series

Analogue refractometer KERN ORA. Refractive index measurement for laboratories and the industry. Features. Technical data

OVENS & INCUBATORS RESPONSE TO THE DEMANDS OF MODERN LABORATORY. INCUBATORS from 5 to 240 lt. OVENS from 5 to 720 lt

-86 0 C FREEZER. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

better measurement Simply a question of

Designer Series. Blanket Warming Cabinet.

Transparent and Functional Motors Application AEL-FTM

OSU Rate of Heat Release Apparatus

Product Data Sheet 4184 N/17X. The engineer's choice

PRODUCT VTS C LOW TEMP. FREEZERS SPECIFICATIONS DIMENSIONS FEATURES LOADING QUANTITIES BIOMEDICAL SOLUTIONS

Accessories Catalogue

CIRCULAIRE LAMINAR AIR FLOW CABINETS with Visionaire Technology.

Product Data Sheet 8412 NHU-519

Centrifugal pumps. Version

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

better measurement Simply a question of

Manual Kinematic Viscosity Bath Tamson TV12

TQC s production facility is located in The Netherlands TQC has distributors in more than 60 countries TQC, DEVELOPERS AND MANUFACTURERS OF PAINT TEST

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Transcription:

Model ED 400 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the natural convection, all thermal processes which use this drying chamber are highly efficient. The ED series ensures fast, uniform drying. BENEFITS Uniform drying conditions thanks to APT.line technology Identical test conditions throughout the chamber interior independent of sample size and quantity Outstanding thermal insulation saves operation costs Model 400 MAIN FEATURES Temperature range: room temperature plus 5 C to 300 C APT.line preheating chamber technology Natural convection Adjustable exhaust air flap Controller with timer functions 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model ED 400 14.1 400 V 3 ph 50/60 Hz with RS 422 ED400-400V-I 9010-0075 208 V 3 ph 60 Hz with RS 422 ED400UL-208V-I 9010-0168 Page 1 / 6

TECHNICAL DATA Description ED400-400V-I 1 ED400UL-208V-I 1 Article Number 9010-0075 9010-0168 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 300 Temperature variation at 150 C [± K] 3 3 Temperature fluctuation at 150 C [± K] 0.5 0.5 Heating-up time to 150 C [min] 71 71 Recovery time after 30 seconds door open at 150 C [min] 31 31 Air change data Air change (approx.) at 150 C [x/h] 10 10 Electrical data Rated Voltage [V] 400 208 Power frequency [Hz] 50/60 60 Nominal power [kw] 3.4 3.4 Unit fuse [A] 3 x 16 3 x 16 Phase (Nominal voltage) [ph] 3 3 Outer dimensions Width net [mm] 1235 1235 Height net [mm] 1025 1025 Depth net [mm] 765 765 Wall clearance back [mm] 160 160 Wall clearance sidewise [mm] 100 100 Doors Unit doors 2 2 Internal Dimensions Width [mm] 1000 1000 Height [mm] 800 800 Depth [mm] 520 520 Measures Interior volume [L] 400 400 Net weight of the unit (empty) [kg] 125 125 permitted load [kg] 90 90 Load per rack [kg] 35 35 Environment-specific data Energy consumption at 150 C [Wh/h] 672 672 Fixtures Number of shelves (std./max.) 2/10 2/10 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. Page 2 / 6

OPTIONS AND ACCESSORIES Access port with silicone plug Alarm function for overheating Analog output, 4 20 ma Calibration certificate, expanded Calibration certificate, temperature back left 10 mm 01 8012-1282 30 mm 01 8012-0540 50 mm 01 8012-0546 10 mm 01 8012-1275 30 mm 01 8012-0537 50 mm 01 8012-0542 100 mm 01, 11 8012-0722 right top 10 mm 01 8012-1268 30 mm 01 8012-0536 50 mm 01 8012-0541 100 mm 01, 11 8012-0721 10 mm 01 8012-1262 30 mm 01 8012-0539 50 mm 01 8012-0545 100 mm 01, 10 8012-0547 Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device 120 V, 208 V option model 8012-1303 230 V, 400 V option model 8012-1299 for temperature values (output not adjustable) 8012-0430 for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1115 for temperature, measurement in center of chamber at specified temperature 8012-1134 temperature measurement incl. certificate and 27 measuring points at specified temperature 8012-1593 temperature measurement incl. certificate, 15-18 measuring points at specified temperature 8012-1572 temperature measurement incl. certificate, 9 measuring points at specified temperature 8012-1551 Cart Cart stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm 9051-0019 Class 3.1 independent temperature safety device Data Logger Kit Data Logger Software with visual alarm (DIN 12880) 04, 12 8012-0032 T 350: For continuous temperature logging from 0 C to 350 C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0714 19 8012-0821 Door gasket made of FKM, silicone-free 03 8012-0497 Door lock lockable door handle 8012-1253 Inner chamber, reinforced Instrument tray including 2 reinforced racks (max. total load 250 kg, max. load per rack 70 kg) 8012-1730 with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm small 4022-0123 with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm large 4022-0124 Page 3 / 6

RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 Interface converter 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0405 230 V, 50/60 Hz option model 8012-0380 Interface converter, USB / RS422 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) 8012-0665 Measurement of air exchange rate in accordance with ASTM D5374, definition and protocol according to ambient temperature 8012-0195 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor Rack additional flexible Pt 100, interior, with external connection incl. LEMO connector (3-pin) 8012-1173 chrome plated 6004-0005 stainless steel 6004-0011 RS 422 interface modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 interface, cable (15 m) RS 422 interface, cable (50 m) RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Shelf, perforated stainless steel 6004-0032 APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 Software version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 Viewing window and interior lighting viewing window in each door, 470 x 290 mm, and 30 W interior lighting 208 V option model 8012-0271 400 V option model 8012-0269 SERVICES Installation services Data Logger Kit installation service unit function instructions for operation and programming of the controller 18 DL100400 Installation and set up of unit at operating location, connect to existing connections 13, 18 DL100100 Preventive maintenance Preventive maintenance Execution of equipment inspection according to maintenance plan 14, 18 DL200200 Calibration services Data Logger Kit calibration service including certificate, one measuring point in center of chamber at specified temperature DL300101 Measurement of air exchange rate including certificate (in accordance with ASTM D5374) DL330000 Temperature measurement 18 measuring points including certificate, 18 measuring points at specified temperature DL300118 Temperature measurement 27 measuring points including certificate, 27 measuring points at specified temperature DL300127 Temperature measurement 9 measuring points including certificate, 9 measuring points at specified temperature DL300109 Page 4 / 6

Validation services Data Logger Kit validation service in accordance with qualification folder 15, 18, 20 DL400100 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL440500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0761 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0942 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL002041 beginning with the date of delivery, wearing parts are not included DL002042 Page 5 / 6

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract (see the chapter on BINDER Service) to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for both items. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 6 / 6

Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on any accessories shown can be found by keying the part number into the search box on our website. The specifications listed in this brochure are subject to change by the manufacturer and therefore cannot be guaranteed to be correct. If there are aspects of the specification that must be guaranteed, please provide these to our sales team so that details can be confirmed.