CE DECLARATION OF CONFORMITY

Similar documents
PRODUCT INFORMATION BOOKLET Document Reference: SPK_SUB_PIB_EN_1.3 Distribution Date: October 30th, SpekTrix Sub [ ]

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

PRODUCT INFORMATION BOOKLET Document Reference: SPK_T_PIB_EN_1.3 Distribution Date: October 30th, SpekTrix-t [ ]

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

Installation Instructions

JBL VTX-V20-DF SUSPENSION MANUAL

SRM1850 SRM W 18" Powered Subwoofers

RF DIRECTIONAL THRULINE POWER SENSOR MODEL 5010

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 12

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Installation & instruction manual

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Attachment Point type APAS

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

Ex m Solenoid Operator Type 0519

EU Declaration of conformity

MV Series Motors Operation & Parts Manual

Tokyo SILO., Marunouchi, Chiyoda-ku Tokyo JAPAN. Rated Voltage: Rated Power: Protection Class:

C300z PRECISION PASSIVE LOUDSPEAKER. FEATURES: 2-way portable Precision Passive loudspeaker system APPLICATIONS

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

PTS SERIES With AE402 Indicator

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

ANNEXES. to the COMMISSION DELEGATED REGULATION

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

METEOROLOGICAL INSTRUMENTS

Immersion temperature sensor QAE26.9.

METEOROLOGICAL INSTRUMENTS

Safety Standards. Model Number:

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Data sheet chainflex CF885.PE

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

1/4" Square Single-Turn Cermet Sealed Trimmer

METEOROLOGICAL INSTRUMENTS

EC Declaration of Conformity, EC DoC. ew Graze QLX Powercore ew Graze EC Powercore ecolor Graze QLX Powercore. ecolor Graze EC Powercore

IB-TPK Tight Pack Kit ibox Series Suspension Brackets

Technical Data Sheet Sigma Series DS Meter

SL Ceiling Mic. Mounting instructions

Differential pressure sensor

Ulyser Component Maintenance Manual

Pressure Transmitters

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Proportional pressure regulators VPPE

Use and Maintenance Manual

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Switching DC Power Supply

NEW AND EXTREME HIGH QUALITY CABLE GUARDS RED LINE USE WITH HIGH VOLUME VEHICULAR TRAFFIC

TECHNICAL BULLETIN Suspension of Objects from Hall Ceilings A supplement to our Technical Regulations

Customer Specification PART NO. V16110

RSB List of Documents and references

Resistance thermometer Model TR10-E, for additional thermowell

SIGMA SERIES DE METER

KARA modular wst. modular wst system RIGGING PROCEDURES VERSION

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

Tiger Lifting Home of the Tiger hoisting range & Tiger subsea lifting products

Tokyo BILD., Marunouchi, Chiyoda-ku Tokyo JAPAN. Industrial Robot

Thermowell For sanitary applications Model TW61, for orbital welding

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Thermowell For sanitary applications Model TW61, for orbital welding

(Text with EEA relevance)

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Differential Pressure Switch QBM81-

Power Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching

Data sheet chainflex CF886

User Manual. T29870 Beam Clamp. Original Instructions. Rev /08//14.

LIFT-O-FLEX Lift-O-Turn LIFTER USER MANUAL. We re here for you. PLACE SERIAL NUMBER LABEL HERE. Have Questions?

COMMISSION REGULATION (EU) / of XXX

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

DECLARATION OF CONFORMITY EUROPEAN UNION DIRECTIVE

Electromotoric Actuators

INSTRUCTION MANUAL. Box/Bag Filler Type KSF640/650

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

COMMISSION REGULATION (EC)

Small Wind Energy - International Standards. Small Wind Energy International Standards. Overview

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

ASSEMBLY INSTRUCTIONS

Cert if ied St ainl ess St eel 316L Lif t ing Eye Nut

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

INSTRUCTION MANUAL. Box/Bag Filler Type KSF660D

Diaphragm/piston pressure switches 250 V

Model 14 Sound Level Meter User Manual Page 1. User Manual for the Model 14 Sound Level Meter

MS General Information Extended Product Type: MS

Certificate of constancy of performance

Operating Instructions Hoist Chains EN 818-7

Design and application

ILED Aquarius Illuminated Windsock. User Manual

Powerful centrifugal fans for universal use: The product ranges TEM and REM

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Data sheet chainflex CFSOFT1

Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

PROTECTION AND CONNECTION. Product environmental information Cable distribution cabinet, Kabeldon CDC

Lexium integrated drives

K&F Rotation Clamp 450

Technical Data Sheet Sigma Series DE Meter

Ride-on lawnmowers (combustion engine powered)

Data sheet chainflex CF881

Transcription:

CE DECLARATION OF CONFORMITY PRODUCT Product Model: Description: p/n 2047570-90 p/n 2047597-90 p/n 2047584-90 p/n 2047564-90 p/n 2047553-90 p/n 2047536-90 p/n 2047528-90 p/n 2047581-90 Loudspeaker / Structural Accessory Dimensions (H X W X D): 248.9mm X 683.0mm X 332.7mm 9.80in X 26.89in X 13.10in 522.7mm X 919.8mm X 790.7mm 20.58in X 36.21in X 31.13in 436.8mm X 683.0mm X 595.0mm 17.20in X 26.89in X 23.43in 690.0mm X 414.0mm X 419.0mm 27.17in X 16.30in X 16.50in 690.0mm X 414.0mm X 419.0mm 27.17in X 16.30in X 16.50in 505.0mm X 315.0mm X 326.0mm 19.88in X 12.40in X 12.83in 505.0mm X 315.0mm X 326.0mm 19.88in X 12.40in X 12.83in 333.0mm X 489.0mm X 501.0mm 13.1in X 19.2in X 19.7in Material: Supplied Accessories: Locking Quick Release Pin* p/n 2046978 *Accessories only supplied for RS208L and RSX12 models. Accessories: RSX12X U-Bracket p/n 2047697-90 RSX8X U-Bracket p/n 2047698-90 FBX100 Flybar p/n 2047169-00 PA-A2 Eyebolt Kit p/n 0028272 Page 1 of 5 July 2016

COUNTRY OF ORIGIN FOR THE PRODUCT AND COMPONENTS Country of Origin: RSX12X U-Bracket RSX8X U-Bracket FBX100 Flybar PA-A2 Eyebolt Kit TECHNICAL SPECIFICATIONS The RSX208L and s are to be suspended below the FBX100 Flybar. When used in accordance with the RADIUS Owner s Manual and Resolution Software the Working Load Limits (WLL) and Design Factor are: Nominal Weight of 18.4 kg / 40.5 lb Nominal Weight of 34.5 kg / 76.0 lb Nominal Weight of FBX100 Flybar 16.3 kg / 36.0 lb Weight Load Limit of FBX100 Flybar (Hang Points 1-8) 165.0 kg / 365.0 lb Weight Load Limit of FBX100 Flybar (Hang Point 9) 145.0 kg / 320.0 lb Weight Load Limit of FBX100 Flybar (Hang Point 10) 127.0 kg / 280.0 lb Weight Load Limit of FBX100 Flybar (Hang Point 11) 118.0 kg / 260.0 lb Ultimate Strength Design Factor >10:1 The RSX129, RSX126, RSX89, and s are designed with the intent to be suspended from the RSX12X U-Bracket, RSX8X U-Bracket or the PA-A2 Eyebolt kit. Nominal Weight of 26.3 kg / 58.0 lb Nominal Weight of 26.3 kg / 58.0 lb Nominal Weight of 15.1 kg / 33.6 lb Nominal Weight of 15.1 kg / 33.6 lb Nominal Weight of RSX12X U-Bracket 8.2 kg / 18.0 lb Nominal Weight of RSX8X U-Bracket 5.0 kg / 10.8 lb Weight Load Limit of RSX12X U-Bracket 27.2 kg / 60.0 lb Weight Load Limit of RSX8X U-Bracket 17.7 kg / 39.0 lb Ultimate Strength Design Factor >10:1 Page 2 of 5 July 2016

STANDARDS CONFORMITY The RSX208L and s are designed with the intent to be suspended only from the FBX100 Flybar in accordance with the RADIUS Owner s Manual and Resolution Software. When suspending an RSX208L/RSX12 loudspeaker array by an FBX100 Flybar, the Flybar must be mounted to the top loudspeaker via the integrated proprietary rigging system. - When using Hang Points 1 through 8, up to eight (8) RSX208L, four (4) RSX12 or a mix of RSX208L and s not exceeding 365lb [165kg] may be vertically suspended in a column below the FBX100 Flybar. - When using Hang Point 9, up to seven (7) RSX208L, three (3) RSX12 or a mix of RSX208L and s not exceeding 320lb [145kg] may be vertically suspended in a column below the FBX100 Flybar. - When using Hang Point 10, up to six (6) RSX208L, three (3) RSX12 or a mix of RSX208L and RSX12 Loudspeakers not exceeding 280lb [127kg] may be vertically suspended in a column below the FBX100 Flybar. - When using Hang Point 11, up to five (5) RSX208L, two (2) RSX12 or a mix of RSX208L and RSX12 Loudspeakers not exceeding 260lb [118kg] may be vertically suspended in a column below the FBX100 Flybar. See Figure A for Hang Point locations. The total weight of the RADIUS array must not exceed the Weight Load Limit of the integrated proprietary rigging system or that of the FBX100 Flybar. FIGURE A FIGURE B Page 3 of 5 July 2016

The RSX8X and RSX12X U-Brackets were designed with the intent to suspend a single RSX129, RSX126, RSX89, or. When suspending an RSX129, RSX126, RSX89, or horizontally, be sure the RSX12X or RSX8X U-Bracket is mounted in the correct orientation with the mounting slot facing upward. Consult the RSX129, RSX126, RSX89, or RSX86 user manual for full instructions on how to properly mount the loudspeaker with U-Bracket. See Figures C, D and E for acceptable u-bracket mounting orientations. FIGURE C FIGURE D FIGURE E The ultimate strengths for the Radius Loudspeakers, Locking Quick Release Pin, FBX100 Flybar and RSX U-Brackets were determined utilizing FEA software and/or calibrated, certified destructive pull-tests. Page 4 of 5 July 2016

Loud Technologies, Inc., as the manufacturer, hereby certifies that, in their delivered versions, the RSX208L Loudspeaker,,,,,,,, and FBX100 Flybar comply with the provisions of the directives and standards listed below. European Council Directives: 2006/42/EC, European Parliament and of the Council on machinery Rigging and lifting: BGV-C1: (German Standard for Lifting Accessories and Audio Rigging) DIN 56950 (German Machinery Installation Safety) European Council Directives: 2014/35/EU (Low Voltage Directive) 2014/30/EU (EMC Directive) All applicable amendments 2011/65/EU (RoHS Directive) EMC: EN55032:2012 Class A EN61000-3-2:2014 EN61000-3-3:2013 EN55103-2:2009 Safety: IEC60065 (ed.7) + am1 + am2 EN60065:2002+A1:2006+A11:2008+A2:2010+A12:2011 CB Ref. Certif. No. US-27775-A1-UL This declaration becomes void in case of any changes to the product without written authorization by Loud Technologies Inc. The Technical Report/File is maintained at: LOUD Technologies Inc. Worldwide Headquarters 16220 Wood-Red Road NE Woodinville, WA 98072, USA Tel: +1 425 892 6500 Tel: +1 866 858 5832 Fax: +1 425 487 4337 E-mail: info@eaw.com Authorized Representative: Case Kuehn Chief Financial Officer LOUD Technologies Inc. Issued: July 2016 Page 5 of 5 July 2016