Installation Instructions for Sun 3 RGB LED. Section One: Install the Constant Current DMX Driver

Similar documents
Section One: Install the Constant Current DMX Driver

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

A CHANNEL. Installation Instructions for Tie Stix Wall 2-Light. Section One: 4SQ Version

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

TWIGGY T1, TUBULAR 1" LENS TUNABLE WHITE 24VDC SYSTEM, 90+CRI

CIRRUS SUSPENSION WITH RECTANGULAR 1 LENS WITH REMOTE POWER, END FEED

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

Finish: Stainless Steel

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

CIRRUS CEILING SQUARE 1 WITH REMOTE POWER

OUTDOOR TRACK. LABELS Assembled in America

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

D3 INSTALLATION GUIDE

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

Motion and Light Sensor Kit LHBAS51

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

TS-350 Fully-Flush Under Vehicle Inspection Light Packages

INSTALLATION INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Customer service: or Upper mounting ring. Canopy

PRODUCTS: AMBIENT GLOW LED LIGHT STRIPS

INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Assembly Instructions Retrofitting

ALL W INSTALLATION INSTRUCTIONS


PIL0478 ISSUE 01/ 07/16

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

USER MANUAL PAR56 LED PAR CANS

APPENDIX B: LISTS OF APPROVED MATERIALS

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES

KLIK LEDpod 40 Patented

PDX and PX Retrofit Series

TS-300 Under Vehicle Inspection Light Packages

Low Pressure Sensor. Overview. Specifications. Installation and Operation

ZA292 Under Vehicle Inspection Light Packages

Purpose. Parts. Page 1 of 10

KLIK LEDpod 50 Patented

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Reveal, 24VDC Plaster-In LED system

NOVA suspension up and down, end feed with remote power supply

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

CIRRUS SUSPENSION WALL WASH WITH REMOTE POWER, END FEED

4" (10cm) 15H1-250W 18F1/F1E - 62W K 18H1-300W. Standard 120V (leave blank) 2 230V 50Hz 3 277V 60Hz. 14" (36cm)

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY!

KLIK LEDpod 40 Patented

Part No. PAFULAxxx. Figure 2

Installing Your 220v J-POD Kit

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

IL 450II Series. LED Roadway Lighting. Application. Advantages of RWL II. Technologically Advanced, low profile design

MODA GRAZE INTERIOR RGB PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

SAFE & SECURE ACTUATOR PRODUCT MANUAL

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

Installation Instructions

EcoSystem Multiple Control Input Ballasts

New X Series Centaurs

Installation Instructions: Eco SpunBay LED High Bays

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

POOL BARON Nicheless Color Changing LED Pool Light

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

SUPERVISION 150C LIGHT SOURCE INTRODUCTION.. 1 INSTALLATION.2 CONTROL SYSTEMS & SETTINGS 5 GENERAL OPERATION & MAINTENANCE..10 TROUBLESHOOTING..

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

LED FLEXIBLE LINEAR DL-FLEX-UP RGB SERIES DL-FLEX-UP-RGB

LPT50BRD (8x11x3 Enclosure)

TAG-DR Series. Indoor or Outdoor LED Driver Box - TAG LED Flood Solutions. Specifications. Overall Dimensions For Reference Only TAG-DR

Pole Mount COD Installations (PMCOD)

Installation Instructions

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Operating Instructions

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

MODA GRAZE INTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

supplemental product catalog Step1Dezigns.com

MODEL 22040, REMOTE CONTROL STAINLESS STEEL OR CHROME SPOT/FLOOD LIGHT INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT!

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Lamp: K-2200K K-2200K

PRIMUS I PRIMUS II. Primus - Downlight. Primus - Wall Wash SPEC SPEC. Trim Options

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Compact 150 Watt Motion Sensing Halogen

LED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90.

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

PIPELINE 1 SUSPENSION UP OR DOWN WITH POWER - END FEED

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

Technical Installation Manual

INSTALLATION INSTRUCTIONS

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

SloanLED THINLED. Constant Current. Installation Guide

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

MODEL SERIES 255 SL REMOTE CONTROL SEARCHLIGHT. Model Series FEATURES SPECIFICATIONS INSTALLATION INSTRUCTIONS

Product Specifications Color Changing LED Can Lighting

Transcription:

Intelligent LED Driver/Controller Output 060VDC, 00050mA, 00W SELV equivalent : 90% typ. in in out out in in out out Group Group Group LEDcode Group Group Group LEDcode 06 Edge Lighting. All Rights Reserved. IPORTANT INFORATION WARNING: Fixture must be installed in accordance with National and Local Electrical codes. Load cannot exceed the total wattage of the LED power supply rating. This fixture must be installed by a licensed electrician. For outdoor installation, use outdoor rated electrical boxes (minimum.5" deep), conduit feedings, and wire nuts. For indoor installation use octagon electrical boxes. This instruction shows a typical installation. For optical controls such as 0 beam tilt, micro louver or glass lens use SUNLL accessory (sold separately). SAVE THESE INSTRUCTIONS! 8 W. Fullerton Ave Chicago, IL 606 Tel: 095 Fax: 9556 www.edgelighting.com info@edgelighting.com Installation Instructions for Sun RGB LED SUN RGBSA 90SUNRGB_0 Section One: Install the Constant Current DX Driver A COVER PHILLIPS SCREW 6 DX LedSync DX DRIVER 00VAC 5060Hz ENCLOSURE POWER SUPPLY 5 : Loosen the six Phillips screws on front of the DX driver to remove the cover. NOTE: Use a deep double gang box to fit the controller and controller power supply. NOTE: Refer to the "Configuring Controller" on page 6 to properly operate the controller. : Connect one end of a red wire to the "VDC" terminal of the controller and the other end of the red wire to the "VDC" terminal of the power supply. : Connect one end of a black wire to the "Ground" terminal of the controller and the other end to the "VDC" terminal of the power supply. : Install a conduit from the controller electrical box to the DX driver enclosure and run the black and white line voltage wires coming from the controller power supply to the DX driver enclosure. 8 DX CABLE (BELDEN #98) 5: Connect the white wire to "N" terminal of the controller power supply. 6: Connect the black wire to "L" terminal of the controller power supply. LedSync DX : Install conduits from the controller, to the main panel (line voltage), and to the SUN housing(s). 00VAC 5060Hz 8: Run proper DX cable (Belden #98 recommended) with three data wires from controller to the DX Driver enclosure. ENCLOSURE TO SUN RGB

in in out out Group Group Group LEDcode in in out out Group Group Group LEDcode B EXT in EXT in VDC VDC 9: Connect one end of a data wire (blue with white stripes wire) to controller "LEDSYNC OUT " terminal. Connect the other end into the DX drive "DX in " terminal. POWER SUPPLY DX in DX in DX in 9 out out out 0 0: Connect one end of a data wire (white with blue stripes wire) to controller "LEDSYNC OUT " terminal. Connect the other end into the DX drive "DX in " terminal. : Connect one end of a data wire (bare wire) to controller "LEDSYNC SHIELD" terminal. Connect the other end into the DX drive "DX in " terminal. NOTE: Do not use the DX terminals on the controller. DX CABLE (BELDEN #98) LedSync DX 00VAC 5060Hz 0 DX DRIVE 9 C : Run the line voltage power wires into the DX driver enclosure. : Connect 6" of #8 AWG black & white wires to brown & blue (~) DX drive terminals. 6 : Connect the hot power wire to the black wire of the DX drive and the black wire coming from the controller with a wire nut. 5: Connect the neutral power wire to the white wire of the DX drive and the white wire coming from the controller with a wire nut. 5 LedSync DX 00VAC 5060Hz 6: ake sure the DX drive is grounded in accordance with local electrical codes, using the ground terminal on the DX drive.

D : Use #8 AWG wires connecting the DX driver to SUN RGBs. DX DRIVER 8: Run the proper wire colors (red, black, green, yellow, blue, brown, white, & orange) from the DX drive to the Sun RGB. Refer to the wiring diagram on page for reference. NOTE: Do not exceed the maximum wattage of the DX driver. ax 0 Sun RGB fixtures can be connected to the DX driver. OIT WHITE/ABER: IF ONLY WIRING SUN RGB 8 WIRES TO SUN RGB E COVER PHILLIPS SCREW 9 L N G 00V Dimming LED LED 9: Replace the DX driver cover and secure it by tightening the six Phillips screws. Section Two: Outdoor Installation F BUILDING WALL NOTE: If installing indoors, skip Sections Two and Three and go to Sections Four and Five to complete installation.." ".6" GOING TO DX DRIVE DX DRIVE : Install conduit(s) from the DX Driver to all in ground fixture outdoor electrical boxes. : Run the proper wire colors (red, black, green, yellow, blue, brown, white, & orange) wires to outdoor electrical boxes. Refer to wiring diagram on page. : ake sure the DX drive power is off. NOTE: Each Sun RGB should be connected to the next Sun RGB in series. The positive wires are the red, green, blue & white and the negative wires are black for red, yellow for green, brown for blue & orange for white. The positive wires of the closest Sun RGB to the DX drive should be (red, green, blue, & white) connected to the proper DX drive terminals. The negative wires (black, yellow brown & orange) of the last Sun RGB should be connected to the negative terminals (black color) of the DX drive. Each Sun RGB should be connected together in series with black wires of the first Sun RGB connecting to the red wire of the next Sun RGB. The yellow wire of the first one to green wire of the next one, the white wire of the first one to the blue wire next one and similarly the orange wire of the first one to white wire of the next one. Refer to the wiring diagram on page.

Section Three: Outdoor Trim Housing Installation G OUTDOOR WATER PROOF SILICON OUTDOOR : Caulk all areas of the outdoor electrical boxes and the conduit connectors with a water proof silicon to prevent water entering in the electrical boxes. H #0 SCREW TRI HOUSING : Align and secure each trim housing to the electrical box holes with the four #0 water sealant screws provided. I PLASTIC CAP." ".6" PLASTIC CAP CONCRETE : Insert the provided plastic caps to all trim housings to prevent particles and concrete debris from entering inside the box. : Poor the concrete up to plastic cap and wait to dry. 5: Refer to Section Six for wiring the trims. TRI HOUSING Section Four: Indoor Installation J OCTAGON NOTE: Use only octagon boxes to install the trim housings indoor. : Install a DX Drive onto the wall or post next to the panel to branch the power to all octagon electrical boxes. DX DRIVER DX DRIVE WALL : Install conduit and run 0 volt power wires from the panel to the branching electrical box. NOTE: Subfloor, floor, and Sun trim housings (.") heights must be considered when positioning the octagon boxes between the joists. : Install conduit(s) from the branching DX driver to all octagon fixture electrical boxes. : Run proper wire sizes from branching DX driver to all fixture electrical boxes. 5: Follow steps in Section One to connect the wires to the power supply.

Section Five: Indoor Trim Housing Installation K TRI HOUSING #8 SCREW : Align and secure the each trim housing to the octagon electrical box holes with the two #8 screws (not provided). L FLOOR PLASTIC CAP SUBFLOOR JOIST "." : Insert the provided plastic caps to all trim housing to prevent dust and debris from entering inside the box. : Finish the floor installation up to the plastic cap. : Refer to Section Six for wiring the trims. PLASTIC CAP.6" TRI HOUSING Section Six: Wiring the Trims GASKET GASKET GASKET INSTALLATION FOR OUTDOOR NOTE: If using the SUNLL accessory, refer to the instruction provided with the SUNLL to install the beam control accessories in each trim prior to wiring the trims. NOTE: For outdoor installation, place the water proof gasket (provided) onto the trim to prevent water leaking inside the electrical box. Use water proof outdoor wire nuts for power connection. : Remove the plastic caps. : Connect each trim wire to one power wire in the electrical box with a wire nut. TRI TRI HOUSING : Place all wire connections inside the electrical box and push the trim completely into the trim housing opening. : Repeat steps and for other trims. NOTE: Each fixture contains an integrated LED lamp. Each Sun consumes 0 watts. 5

Section Seven: Operation Guide for CDP Controller Selecting odes Configure your CDP Controller by setting the DIP switches on the front: O N O N 5 6 5 6 COLOR ODE CHASE ODE NOTE: The DIP switches must remain accessible after installation. When making changes in the DIP switch settings, disconnect and reconnect the power supply to activate new settings. Operating Controller Turn the light on Change brightness Turn the light off Advanced Operation for Color ode BRIGHTNESS Turn the light on Activate configuration mode Set color Save color saving SEC Advanced Operation for Chase ode Turn the light on Activate configuration mode Set show speed Save color setting SEC 6

DX CABLE (BELDEN #98) DX in EXT in DX in EXT in DX in out VDC out VDC out N L LINE VDC LEDcode LedSync DX in in out out Group Group Group CONSTANT CURRENT DX DRIVER Wiring Diagram 00VAC 5060Hz INPUT POWER NEUTRAL HOT AGNEFIED FOR CLARITY RED RED GREEN GREEN BLUE BLUE WHITE/ABER WHITE/ABER NOTE: Do not use WHITE/ABER wire terminals if connecting SUN RGB Version. SUN RGB SUN RGB SUN RGB LAST