- Wiring Brochure Universal Reset Module 422e

Similar documents
- Wiring Brochure Universal Reset Module 422

- Wiring Brochure Mixing Expansion Module 440

- Wiring Brochure tekmarnet 4 Thermostat 545

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 336

- Wiring Brochure tn4 Gateway 483

- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

SetPoint 501 and 501s Controllers Installation and Operation Manual

SetPoint 150 Controller Installation Manual

Installation & Operation Manual

Installation & Operation Manual

E Series CE Approved Intermittent Pilot Ignition Control

SIGNAL WORDS QUALIFIED PERSON

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Powers TM Controls EA 338 Electronic Actuator

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

A419ABG-3C Electronic Temperature Control

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

High Frequency SineWave Guardian TM

INSTALLATION/OPERATING INSTRUCTIONS MCP

Electric Stone Hearth Oven

OnCommand Troubleshooting Guide Hayward Industries

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

1.Safe testing IMPORTANT:

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

MODEL ELC-12/40-CVM-D BATTERY CHARGER

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Fan Coil Unit (FCU) Fan Motor Control

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Modulating Furnace Information. Warning on Meter Setting - Read First!

G72x Series Direct Spark Ignition Controls

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

Installation Instructions

MODEL ELC-12/60-D BATTERY CHARGER

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Installation Instructions

Safety & Installation Instructions

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

G600 Series Replacement Intermittent Pilot Ignition Controls

Instruction Manual. Q Series 2 Motor Control Modules - OEM

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Installation and Construction Notes for EVSE4

How to Select the RE Industrial Actuator Part Number

Mini Multimeter with Non-Contact Voltage Detector (NCV)

R & D SPECIALTIES ROTROL I USER'S MANUAL

6900-( )-( ) HIGH SPEED SANDWICH PRESS

Application Engineering

Owner's/Installation Manual

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

HAN-L62 MOUNTING PLATE

G76x Direct Spark Ignition Controls

SYSTEM CONTROL KIT. Model: CK-41F ITEMS INCLUDED IN KIT:

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Switching DC Power Supply

Freedom egen System End-of- Line Functional Checklist

BATTERY OPERATED DIGITAL MILLI-OHMMETER

Planning Low Voltage Layouts

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Declaration of Conformity

HILLSTONE DC LOAD BANK

GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

SAVE THESE INSTRUCTIONS

Solar Controller SUNGO S

MC200CAB/4 Integral Version

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

True RMS Autoranging Multimeter

TC62D Installation Instructions

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

8300 Series Installation Guidelines

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Autoranging Multimeter

OPERATING INSTRUCTION

B21 Series BASOTROL Gas Valve

INSTALLATION INSTRUCTIONS

Electronically Commutated Motor Wiring Manual

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

L5000 Plus. Installation & Setup Guide

ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance

DIGITAL RCD(ELCB) TESTER

Transcription:

- Wiring Brochure Universal Reset Module 422e W 422e 01/08 1 Information Brochure hoose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in wiring instructions 4 Wiring Brochure Wiring and installation of specific control 5 Data Brochure ontrol settings and sequence of operation 6 Job Record Record settings & wiring details for future reference Introduction The following wiring brochure describes how to wire the kanmor Universal Reset Module 422e. The 422e is to be installed in an enclosure together with a kanmor Power Manager 345e. The 422e controls one boiler (on-off or modulating),, setpoint and one mixing (either variable speed injection or floating action). The wiring of tekmarnet 4 (tn4) components is simple and cost effective. 51 52 53 54 55 56 R 2 tn4 24 V (ac) Boil/Mix2 57 58 59 60 Output 1 VA Floating Output: 24 V (ac) 8 VA Limited power available, see wiring brochure Opn ls R R 61 62 63 Powered Output + - om Boil Mix om Out Mod (dc) 64 65 66 67 68 69 70 H7014A Test Var. Fuse T2.5 A 250 V tn4 / Mix2 Boil Sens Sup / Ret On-Off / Mod Off / kanmor Stager Off / Flushing 71 72 Menu Item 73 74 Variable Speed 2.5 A Universal Reset Module 422e INSTALLATION ATEGORY II Made in anada Supply/signal wires 90 min. tektra 991-04 For product instructions, see brochure Var. : 230 V (ac) 2.5 A s: 20-260 V (ac) Relay Rating: 230 V (ac) 5 A aution! Disconnect All Power before Opening 10 A 75 76 77 78 max Primary Mix Sys P1 kanmor wiring Enclosure (not included) kanmor Power Manager 345e 1 of 12 2008 W422e - 01/08

Table of ontents Wiring Symbols & Definitions... 2 Module Installation... 3 Electrical Drawings... 4-7 Wiring the ontrol... 8-9 Troubleshooting Instructions... 9-11 Technical Data... 12 Wiring Specification Guide... 12 Wiring Symbols, signals control to operate. Requires a power and neutral connection. Use 24 to 260 V (ac), usually switched externally. Example: Dry contact switch. Operates a device. Example: Powered switch. 24-230 V (ac) power, switched output to valve, pump, etc. Variable Power Switch. Varied power output to injection pump. Fuse, field replaceable. Black reverse lettering denotes an internally powered output. Do not apply power to these terminals. Serious control damage will result. Earth ground tekmarnet 4 Definitions The following defined terms and symbols are used throughout this manual to bring attention to the presence of hazards of various risk levels, or to important information concerning the life of the product. aution: Refer to accompanying documents aution: Refer to accompanying documents INSTALLATION ATEGORY II Local level appliances aution Improper installation and operation of this control could result in damage to the equipment and possibly even personal injury or death. It is your responsibility to ensure that this control is safely installed according to all applicable codes and standards. This electronic control is not intended for uses as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit. Do not attempt to service the control. Refer to qualified personnel for servicing. Apart from any field replaceable fuse(s) there are no user serviceable parts. Attempting to do so voids warranty and could result in damage to the equipment and possibly even personal injury or death. 2008 W 422e - 01/08 2 of 12

Module Installation Install the Universal Reset Module 422e in the left side of a tekmarnet 4 (tn4) wiring enclosure. The enclosure comes with a Power Manager pre-installed in the right side. Review the figure below to understand the installation of the 422e: To Install the 422e 1. Remove the front cover of the wiring enclosure by removing the two screws. 2. Remove the left side blank by removing the centre screw holding the blank and the Power Manager in place. Make sure the Power Manager stays in place. 3. Discard the blank. 4. The 422e has connector pins protruding from the underside of the board. The Power Manager has wiring harnesses with plugs that connect to these pins. Remove the required wiring harnesses from their retaining clips in the enclosure. 5. arefully connect the Power Manager s plugs onto the pins on the underside of the 422e. There is one smaller gauge connector with three pins and one larger gauge connector with 2 pins. These connectors can be installed only one way. Take care to ensure a good connection and avoid bending the pins. 6. Lower the 422e into the enclosure at an angle. Insert the two tabs on the left side of the 422e in to the corresponding slots in the left side of the wiring enclosure. 7. Lower the 422e toward the center of the enclosure until the two halves fit together. Make sure that the connector wires are placed underneath without pinching the wire. 8. Replace the center screw to hold the two controls in place. 9. Strip all wiring to a length of 3/8 in. or 10 mm for all terminals. Electrical Drawings The electrical drawing examples on the following pages show the 422e in common applications hoose the drawing that most accurately depicts the components in your system and use that drawing as a guide to aid in wiring your system. These are only concept drawings, not engineered drawings. They are not intended to describe a complete system nor any particular system. It is up to the system designer to determine the necessary components for and configuration of the particular system being designed including additional equipment isolation relays (for loads greater than the controls specified output ratings) and any safety devices which in the judgement of the designer are appropriate in order to properly size, configure and design that system and to ensure compliance with building and safety code requirements. 3 of 12 2008 W 422e - 01/08

Electrical Application 422e E1 Description: Variable Speed Injection Mixing,,, Single On / Off, External tn4 = Temperature. On / Off all all External tn4 ontrol Temp. Mix Outdoor 070e tn4 51 52 53 54 55 56 R 2 tn4 24 V (ac) Boil/Mix2 57 58 59 60 Output 1 VA Floating Output: 24 V (ac) 8 VA Limited power available, see wiring brochure Opn ls R R 61 62 63 Powered Output + - om Boil Mix om Out Mod (dc) 64 65 66 67 68 69 70 24 V (ac) R & tn4 = Mix 1 temp. H7014A Menu Universal Reset Module 422e See D 422e tn4 / Mix2 Boil Sens Sup / Ret On-Off / Mod Off / kanmor Stager Off / Flushing Item tektra 991-04 For product instructions, see brochure Var. : 230 V (ac) 2.5 A s: 20-260 V (ac) Relay Rating: 230 V (ac) 5 A aution! Disconnect All Power before Opening onnections from Power Manager Test Var. Fuse T2.5 A 250 V 71 72 73 74 Variable Speed 2.5 A INSTALLATION ATEGORY II Made in anada Supply/signal wires 90 min. 75 76 Primary 77 78 Mix Sys P1 10 A max 230 V (ac) L & N To ground Refer to Job Record for Maximum Allowable Loads 2008 W 422e - 01/08 4 of 12

Electrical Application 422e E2 Description: Floating Action Mixing,,, Single 0-10 V (dc) Modulating, External tn4 = Mix 2 Temperature. *May be required for modulating boiler Signal* all all External tn4 ontrol Temp. Mixing Valve Floating Action 24 V (ac) Motor 0-10 V (dc) Modulating Mix Outdoor 070e tn4 om Opn ls 51 52 53 54 55 56 R 2 tn4 24 V (ac) Boil/Mix2 57 58 59 60 Output 1 VA Floating Output: 24 V (ac) 8 VA Limited power available, see wiring brochure Opn ls R R 61 62 63 Powered Output + - om Boil Mix om Out Mod (dc) 64 65 66 67 68 69 70 24 V (ac) R & tn4 = Mix 1 temp. H7014A Menu Universal Reset Module 422e See D 422e tn4 / Mix2 Boil Sens Sup / Ret On-Off / Mod Off / kanmor Stager Off / Flushing Item tektra 991-04 For product instructions, see brochure Var. : 230 V (ac) 2.5 A s: 20-260 V (ac) Relay Rating: 230 V (ac) 5 A aution! Disconnect All Power before Opening onnections from Power Manager Test Var. Fuse T2.5 A 250 V 71 72 73 74 Variable Speed 2.5 A INSTALLATION ATEGORY II Made in anada Supply/signal wires 90 min. 75 76 Primary 77 78 Mix Sys P1 10 A max 230 V (ac) L & N 5 of 12 2008 W 422e - 01/08

Electrical Application 422e E3 Description: Floating Action Mixing,,, Multi-stage ontrol, External tn4 = Temperature. *Refer to boiler staging control info all all External tn4 ontrol Temp. Mixing Valve Floating Action 24 V (ac) Motor 0-10 V (dc) Signal to kanmor Stager* Mix Outdoor 070e tn4 om Opn ls 51 52 53 54 55 56 R 2 tn4 24 V (ac) Boil/Mix2 57 58 59 60 Output 1 VA Floating Output: 24 V (ac) 8 VA Limited power available, see wiring brochure Opn ls R R 61 62 63 Powered Output + - om Boil Mix om Out Mod (dc) 64 65 66 67 68 69 70 24 V (ac) R & tn4 = Mix 1 temp H7014A Menu Universal Reset Module 422e See D 422e tn4 / Mix2 Boil Sens Sup / Ret On-Off / Mod On / kanmor Stager Off / Flushing Item tektra 991-04 For product instructions, see brochure Var. : 230 V (ac) 2.5 A s: 20-260 V (ac) Relay Rating: 230 V (ac) 5 A aution! Disconnect All Power before Opening onnections from Power Manager Test Var. Fuse T2.5 A 250 V 71 72 73 74 Variable Speed 2.5 A INSTALLATION ATEGORY II Made in anada Supply/signal wires 90 min. 75 76 Primary 77 78 Mix Sys P1 10 A max 230 V (ac) L & N To ground Refer to Job Record for Maximum Allowable Loads 2008 W 422e - 01/08 6 of 12

Electrical Application 422e E4 Description: Variable Speed Injection Mixing, Storage Tank or Potable Water Heat Source, External tn4 = Mix 2 Temperature. Storage tank heat source = Off Potable water heat source = Flushing Enable Signal External tn4 ontrol Mix 2 Temp Optional Mix Outdoor 070e tn4 51 52 53 54 55 56 R 2 tn4 24 V (ac) Boil/Mix2 57 58 59 60 Output 1 VA Floating Output: 24 V (ac) 8 VA Limited power available, see wiring brochure Opn ls R R 61 62 63 Powered Output + - om Boil Mix om Out Mod (dc) 64 65 66 67 68 69 70 24 V (ac) R & tn4 = Mix 1 temp H7014A Menu Universal Reset Module 422e See D 422e tn4 / Mix2 Boil Sens Sup / Ret On-Off / Mod Off / kanmor Stager Off / Flushing Item tektra 991-04 For product instructions, see brochure Var. : 230 V (ac) 2.5 A s: 20-260 V (ac) Relay Rating: 230 V (ac) 5 A aution! Disconnect All Power before Opening onnections from Power Manager Test Var. Fuse T2.5 A 250 V 71 72 73 74 Variable Speed 2.5 A INSTALLATION ATEGORY II Made in anada Supply/signal wires 90 min. 75 76 Primary 77 78 Mix Sys P1 10 A max 230 V (ac) L & N To ground Refer to Job Record for Maximum Allowable Loads 7 of 12 2008 W 422e - 01/08

Wiring the ontrol Terminals 51-78 The following section explains how to wire individual devices to the Universal Reset Module 422e. For step by step wiring refer to the terminal number on the right of the page. Before wiring ensure all power is turned off and take all necessary precautions. Install the supplied wiring compartment barriers by sliding them into the grooves provided as to isolate the low and high voltage wiring. Strip all wiring to a length of 3/8 in. or 10 mm for all terminals. Refer to the current and voltage ratings at the back of this brochure before connecting devices to this control. Wiring the Terminals 51-52 Terminals 51-52 are a dry contact. No power is available from this switch. When the switch at 51-52 is closed the boiler is to turn on. The boiler gets no power from these terminals and the boiler must be wired to power as per the manufacturers directions. These two terminals are typically connected to the boiler s control circuit (commonly labeled as T-T). onnect these two terminals directly to the boiler T-T connections. T-T contacts on boiler 51 52 Wiring the s (, ) Terminals 53-58 To generate a a voltage between 20 and 260 V (ac) must be applied across the terminals (53-54). To generate a, a voltage between 20 and 260 V (ac) must be applied across the terminals (55-56). 24 V (ac) is provided on terminals 57 and 58 to power the and the. Each demand uses approximately 0.1 VA. The example below shows the wiring to generate a. Switch (from ontrol or aquastat) R 24 V (ac) 53 54 55 56 57 58 Wiring tekmarnet 4 (tn4) Between Devices Terminals 59-60 Terminals 59 and 60 provide a tn4 connection for tn4 devices on either the or Mix 2 tn4 bus. onnect terminals 59 () and 60 (tn4) to the corresponding terminals on the other tn4 device. Polarity is important. Ensure that terminal 59 () is connected to the terminal on the tn4 device and that terminal 60 (tn4) is connected to the tn4 terminal on the tn4 device. tn4 connection on additional control tn4 2 tn4 Boil/Mix2 59 60 Wiring a Floating Action Actuator (Mixing Valve) Terminals 61-63 The control operates a 24 volt floating action (power open / power close) valve motor. Power is provided through an internal transformer to a maximum of 8 VA. onnect the wiring from the motor to terminals 61, 62, 63 where terminal 61 is 24 volt (neutral) and terminal 62 is 24 V R (hot) for opening and terminal 63 is 24 V R (hot) for closing. Valve motor contacts om Opn ls Opn ls R R 61 62 63 2008 W 422e - 01/08 8 of 12

Wiring the Modulating Output Terminals 64-65 The control provides a 0-10 V (dc) modulating output to a single modulating boiler or to a kanmor boiler staging control that accepts an External Input Signal in place of an outdoor sensor. (Example: 264e) Polarity is important. onnect the + wire from the boiler or staging control to terminal 64 and the wire from the boiler or staging control to terminal 65. Note: Some modulating boilers may also require an on / off signal in addition to the modulating signal. See terminals 51 and 52. + - Modulating or kanmor Stager + - Mod (dc) 64 65 and Mixed (kanmor ) Terminals 66-69 onnect the two wires from the to the om and Boil (66-67) terminals. The is used by the control to measure the boiler water temperature. onnect the two wires from the Mix to the om and Mix (68-69) terminals. The Mix is used by the control to measure the mix supply temperature. mounted on mix supply pipe mounted on boiler pipe om Boil Mix om 66 67 68 69 Outdoor (kanmor 070e) Terminals 69-70 onnect the two wires from the Outdoor 070e to the om and Out (69-70) terminals. The outdoor sensor is used by the control to measure the outdoor air temperature. Note: If an Outdoor 070e is connected to a tekmarnet 4 thermostat in the system, it is not required to be connected to the control. mounted on exterior wall om Out 69 70 Wiring the Variable Speed Terminals 73-74 The control varies the speed of a permanent capacitor, impedance protected or equivalent pump motor that has a locked rotor current of less than 2.4 A. Refer to Essay E 021e for a listing of approved pumps. If a variable speed injection pump is used, the pump is wired directly to terminals 73 and 74. The pump s ground wire is connected to the ground screw provided in the wiring chamber. L & N 73 74 Variable Speed Wiring the Primary, and Mixing P1 Terminals 71-72, 75-76, 77-78 The control operates a Primary, a and a Mixed System (Mix Sys P1). If a Primary is used, the pump is wired directly to terminals 75 and 76. If a is used, the pump is wired directly to terminals 71 and 72. If a Mixed System is used, the pump is wired directly to terminals 77 and 78. The pumps ground wires are connected to the ground screw provided in the wiring chamber. Note: For pumps larger than the control s rated capacity, an external isolation relay must be used. L & N 75 76 Primary 9 of 12 2008 W 422e - 01/08

Troubleshooting the Wiring General The following tests are to be performed using standard testing practices and procedures and should only be carried out by properly trained and experienced persons. A good quality electrical test meter, capable of reading from at least 0-300 V (ac), 0-30 V (dc), 0-2,000,000 Ohms, and testing for continuity is essential to properly test the wiring and sensors. Test Meter ### ontrol Terminals For an explanation on the use of the Test Button, the Test sequence or any error messages, refer to the Data Brochure. Testing the ontrol Terminals 51-78 Testing the ontact Terminals 51-52 1. Shut off power to the control and the boiler circuit. 2. Remove the front cover from the control. Disconnect the wires from the boiler contact (terminals 51-52). 3. Apply power to the control and press the Test button. 4. Use an electrical test meter and check for continuity between terminals 51 and 52. When the burner symbol is displayed in the LD, there should be continuity. When the burner symbol is not displayed in the LD, there should be no continuity. 5. Reconnect the wires to the boiler contact (51-52), install the front cover on the control and apply power to the boiler circuit. Testing the or Terminals 53-58 1. Remove the front cover from the control. 2. Use an electrical test meter to measure (ac) voltage between the terminals (53-54) or the terminals (55-56). When the demand device is on a voltage between 20 and 260 V (ac) should be measured between terminals and the LD should display DEM and or SETP. When the demand device is off, less than 5 V (ac) should be measured between the terminals. Testing Auxiliary 24 V Power Supply Terminals 57-58 1. Remove the front cover from the control. 2. Use an electrical test meter to measure (ac) voltage between the Power R and Power terminals 57 and 58 The reading should be 24 V (ac) + / 10%. 3. If power is not present: heck the power supply to the Power Manager and the field replaceable fuse for the transformer on the Power Manager. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. Testing tn4 Network To test the tn4 Network, check the wires for continuity. 1. Disconnect the two wires (tn4 and ) at one end and connect them together. 2. Go to the other end of the wires and disconnect them. 3. Using an electrical test meter, check for continuity. Testing Floating Action (power open / power closed) Terminals 61-63 1. Ensure that the control is set to operate the floating action output. 2. Remove the front cover from the control. 3. Press the Test button. 4. When OPN is displayed in the LD, use an electrical test meter to measure the (ac) voltage between the and R Opn (Open) terminals (61-62). The reading should be 24 V (ac) + / 10%. 2008 W 422e - 01/08 10 of 12

5. When LS is displayed in the LD, use an electrical test meter to measure the (ac) voltage between the and R ls (lose) terminals (61-63). The reading should be 24 V (ac) + / 10%. 6. If power is not present: heck the power supply to the Power Manager and the field replaceable fuse for the transformer on the Power Manager. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. 7. When OPN and LS are not displayed in the LD, use an electrical test meter to measure the (ac) voltage between the and R Opn (Open) terminals (61-62) and the and R ls (lose) terminals (61-63). The reading should be 0 V (ac). Testing the Modulation Output (0-10 V dc) Terminals 64-65 1. Ensure that the control is set to operate the modulating output. 2. Remove the front cover from the control. 3. Press the Test button. 4. When the % output graph and the burner symbol are displayed in the LD, use an electrical test meter to measure the (dc) voltage between the Mod (dc) + and the Mod (dc) terminals (64-65). The reading should vary between 0 V (dc) and 10 V (dc). 5. If power is not present: heck the power supply to the Power Manager and the field replaceable fuse for the transformer on the Power Manager. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. Testing kanmor s Terminals 66-70 To test the sensors, the actual temperature at each sensor location must be measured. Use a good quality digital thermometer with a surface temperature probe for ease of use and accuracy. Where a digital thermometer is not available, strap a spare sensor alongside the one to be tested and compare the readings. Disconnect each sensor from the control. Test the sensors resistance according to the instructions in the sensor Data Brochure D 070e. Testing the Variable Speed Injection Terminals 73-74 1. Ensure that the control is set to operate the variable speed output. 2. Remove the front cover from the control. 3. Press the Test button. 4. When the Mix 1 output ramps up to 100%, use an electrical test meter to measure the (ac) voltage between the Variable Speed terminals (73-74). The reading should be 230 V (ac) + / 10%. Note: at outputs below 100% the electrical test meter will not read accurately. If power is not present: heck the power supply to the Power Manager and the field replaceable fuse for the variable speed output. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. Testing, Primary, and Mixing System P1 Terminals 71-72, 75-76, 77-78 1. Remove the front cover from the control. 2. Press the Test button. 3. When the Primary (Prim) symbol is displayed in the LD, use an electrical test meter to measure the (ac) voltage between the Primary terminals (75-76). 4. When the Mixing System symbol 1 is displayed in the LD, use an electrical test meter to measure the (ac) voltage between the Mixing System terminals (77-78). 5. When the symbol is displayed in the LD, use an electrical test meter to measure the (ac) voltage between the terminals (71-72). The reading should be 230 V (ac) + / 10%. Note: The proper mode must be selected before testing the pump output. If power is not present: heck the power supply to the Power Manager. Also check the Plug in connections on the underside of the control. 11 of 12 2008 W 422e - 01/08

Technical Data Universal Reset Module 422e; Two tekmarnet 4, Mixing,, & ontrol Microprocessor PID control; This is not a safety (limit) control Packaged weight 1.87 lb. (848 g) Dimensions 3-5/8 H x 5-3/8 W x 9/16 D (92 x 137 x 14 mm) Approvals E Approved Ambient conditions Indoor use only, 32 to 122 F (0 to 50 ). RH 80% to 88 F (31 ), down to 50% from 104 to 122 F (40 to 50 ) Altitude <2000 m, Installation ategory II, Pollution ategory 2 Power Supply Provided by interconnected Power Manager Relay 230 V (ac) 5 A 1/4 hp, pilot duty 240 VA Primary Relay 230 V (ac) 5 A 1/4 hp, pilot duty 240 VA Mixing P1 Relay 230 V (ac) 5 A 1/4 hp, pilot duty 240 VA Variable Speed 230 V (ac) 2.5 A 1/6 HP, fuse T2.5 A 250 V ombined Load 10 A Maximum (for, Primary, Mixing and Variable Speed ) Floating Action Output 24 V (ac) 8 VA Maximum Modulation Output 0-10 V Minimum 2500 Relay 230 V (ac) 5 A 1/4 hp, pilot duty 240 VA s 20-260 V (ac) / 0.1 VA @ 24 V s NT thermistor, 10k @ 77 F (25 ± 0.2 ) ß=3892 Included Outdoor 070e and 2 of Universal s kanmor ontrol Systems Ltd. 5100 Silver Star Road Vernon, B.. ANADA V1B 3K4 250-545-2693 Fax. 250-549-4349 Web Site: www.kanmor.com 2008 by kanmor ontrol Systems Ltd. Used with permission. kanmor trademark is used under license 12 of 12 All specifications are subject to change without notice. Printed in anada. W 422e - 01/08.