Conductivity Measuring Cells ConduMax W CLS 19

Similar documents
Conductivity Sensors ConduMax W CLS 19

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Conductivity Measuring Sensor InduMax H CLS 52

Technical Information

Conductivity Measurement CLM 280

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Ceraliquid CPS41 and CPS41D

ph-kompaktelektrodensystem sensopac CPA 320

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Orbipore CPS91 and CPS91D

Process ph / ORP Electrode Holder ProbFit CPA 463 S

Digital ph transmitter

Digital ph transmitter

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Electromagnetic Flow Monitor magphant

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Technical Information Cleanfit CPA472D

Electromagnetic Flow Monitor magphant

Signet V(D) to V(D) PVDF Conductivity Electrodes

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Level Limit Switch liquiphant FTL 365 / FTL 366

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Level Limit Switch liquiphant FTL 360 / FTL 361

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Orbisint CPS11 and CPS11D

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Orbisint CPS11 and CPS11D

Inductive conductivity meter

Portable Ultrasonic Flow Measuring System prosonic flow 92

Technical Information Ceraliquid CPS41D and CPS41

Inductive conductivity meter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

RTD Assembly TH15. Compact Instructions. KA195R/24/ae/

Signet Conductivity/Resistivity Electrodes

INSERTION Adaptor for analysis

Temperature Sensor without thread

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Plastic tube variable area flowmeter for liquids and gases

Ceraliquid CPS42/CPS42D/CPS43

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Level Probe multicap DC 16

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Technical Information Omnigrad TST90, TET90

Signet Conductivity/Resistivity Electrodes

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Orbisint CPS12/CPS12D/CPS13

OEM Pressure Transmitters

Zirconia Oxygen Probe

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Pressure transducer DMU 01K Compact version

Metso Conductivity for sensor series 9400 and 9500

JUMO ecotrans Lf 01/02

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Insertion magnetic inductive flowmeter

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Thermowell for temperature sensors omnigrad M TW 13

Dissolved Oxygen, ph, and Conductivity

Cleanfit P CPA474. Technical Information. Retractable plastic process assembly with ball valve for ph and ORP electrodes

Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

mass flowmeter for compressed air

Analytical Instruments Two-Electrode Conductivity Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

Float switch For industrial applications, with temperature output Model RLS-3000

ENDURANCE Conductivity Sensors

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet ph/orp Electrodes

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Smart Electromagnetic Flowmeter Detector for Sanitary use

Magnetic-Inductive flow Meter fmi

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

Signet 3719 ph/orp Wet-Tap Assembly

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Signet ph/orp Electrodes

Metal-Protected Measuring Inserts

Differential pressure gauge Model , copper alloy Model , stainless steel version

Diaphragm seal with threaded connection Plastic version Model

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Operating Instructions (from serial number 3000)

Thermowell for temperature sensors omnigrad M TW 11

Addendum to the Catalog Diagnostic unit /DUE for function and wear monitoring of brakes BE.., BF.., BT..

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Transcription:

Technical Information TI 110C/24/ae Conductivity Measuring Cells ConduMax W CLS 19 Two-electrode measuring sensors with cell constant k = 0.01/cm or k = 0.1/cm Area of application Measurement in pure and ultrapure water: Monitoring ion exchangers Reverse osmosis The measuring range of the sensors depends on the cell constant k: k = 0.01/cm: 0.04 to 20 µs/cm k = 0.1/cm: 0.1 to 200 µs/cm Sensors with a Pt 100 temperature sensor are used together with the conductivity measuring instruments Liquisys M CLM 223/253 equipped with automatic temperature compensation. For measurement of specific resistance, MΩ cm, measuring ranges are available in the program of the transmitter. Benefits at a glance Installation in pipes or flow chambers Pt 100 temperature sensor for temperature compensation Compact design Low cost The Power of Know How

Function and system design Measuring principle Conductive conductivity measurement The conductivity of liquids is measured with a measuring system that has two coaxially arranged electrodes similar to a capacitor. The electric resistance or its reciprocal value, the conductance G, is measured according to Ohm s law. The specific conductivity K is determined using the cell constant k that is dependent on the sensor geometry. AC Conductive conductivity measurement AC = Power supply I = Current meter V = Voltage meter V I ConduMax W CLS 19 important properties Electrodes ConduMax W CLS 19 has coaxial measuring electrodes made of polished 316Ti stainless steel Temperature compensation In addition, a Pt 100 temperature sensor is installed to measure the process temperature. Easy connection The sensors are connected via a 4-pole DIN-plug that can be secured with a screw. The plug is equipped with a Pg 9 cable gland for insertion of the measuring cable Installation The sensor can be installed directly via the 1/2 NPT process connection. Mounting the sensor in cross or T-pieces with DN 20 requires a PVC-threaded coupling available as an accessory. For easy installation in cross or T-pieces with DN 32, 40 or 50, adapter couplings (made of PVC for gluing) and a 1-1/2 clamp coupling (made of PVDF) are available as accessories. Durability The sensor can withstand pressures up to 87 psi (6 bar) at 68 F (20 C) and can be applied with temperatures up to 140 F (60 C) at 14 psi (1 bar). 2

} MYCOM S CLM 153 ENDRESS+HAUSER MEAS DIAG CAL PARAM ConduMax W CLS 19 Measuring system A complete measuring system consists of: A CLS 19 conductivity sensor A transmitter, e.g. Liquisys M CLM 253 A CYK 71 measuring cable 2 1 3 Measuring system example 1 CLS 19 ConduMax W sensor 2 CLM 253 Liquisys M transmitter 3 Measuring cable Input Measured values Cell constant k Conductivity and temperature Dependent on version ordered: k = 0.01/cm k = 0.1/cm Measuring ranges Temperature sensor Conductivity k = 0.01/cm k = 0.1/cm Temperature Pt 100 (referenced to water at 77 F) 0.04 µs/cm to 20 µs/cm 0.1 µs/cm to 200µS/cm 14 to +140 F (-10 to +60 C) Cable specifications The ConduMax W is connected to the transmitter using the special measuring cable CYK 71 Cable Sensor Pin Coax BK Coax inner 1 2 Shield (outer electrode) Conductivity (inner electrode) Outer shield (PE transmitter) GN WH YE } 3 4 Pt 100 BN n.c. Measuring cable CYK 71 3

Installation Installation instructions The sensor is mounted directly via the 1/2 NPT process connection. Sensors can be mounted in a cross or T-piece with optional adapter couplings (see accessories). When mounting the sensor, make sure that the measuring surfaces are completely wetted by the process fluid. When working in ultrapure water, ingress of air must be avoided since dissolved air, particularly CO 2, may increase the conductiivity by up to 3 µs/cm. 1 2 3 Installation in cross or T-piece 1 PVC-threaded coupling (see accessoies) 2 Adapter coupling for gluing for DN 32, 40 or 50 (see accessories) 3 Cross or T-piece DN 32, 40 or 50 1.38 (35) Immersion depth Environment Ingress protection NEMA 4 (IP 65) Ambient temperature Refer to process temperature Process Process temperature Process pressure 14 to +140 F (-10 to +60 C) Maximum 87 psi (6 bar) at 140 F (60 C) Pressure / temperature load curve psi (bar) 87 (6) 72 (5) 58 (4) 43 (3) 29 (2) 14 (1) 14 (-10) 32 (0) 50 (10) 68 (20) 86 (30) 104 (40) 122 (50) 140 (60) F ( C) CLS 19 pressure/temperature load curve 4

Mechanical construction Design, dimensions 2 1 3 4 4.96 (126) 0.67 (17) 2.87 (73) 0.67 (17) AF 36 1/2 NPT } 5 Ø 0.63 (16) CLS 19 design 1 Connection head 2 Measuring cable outlet 3 Threaded shaft (PES) 4 Electrodes (coaxially arranged) 5 Measuring surface CLS 19, dimensions in inches (mm) Weight Approximately 0.2 lb (0.1 kg) Mateirals Process connection Cable connection Electrodes Sensor shaft 1/2 NPT Pg 9 cable gland 316Ti SS PES (Polyethersulfone) 5

Ordering information ConduMax W CLS 19 Conductivity Measuring Cell CLS 19-1 2 3 4 1 Measuring range and cell constant A Range: 0.04-20 µs/cm (k = 0.01) B Range: 0.1-200 µs/cm (k = 0.1) 2 Process connection/material 1A 1/2 NPT / sensor shaft PES 3 Cable connection 1 4-pole connector with Pg 9 fitting 4 Temperature sensor A Integrated Pt 100 temperature sensor D Without temperature sensor Accessories Installation couplings PVC-threaded coupling For cementing in standard PVC cross or T-pieces with DN 20, with G 1/2 internal thread, self-sealing, 1/2 NPT sensor thread: Order number: 5006636 PVC equalizing sleeves AM For adapting the PVC threaded coupling to larger nominal diameters, AM 32: for installation into cross or T-piece DN 32 Order number: 50004738 AM 40: for installation into cross or T-piece DN 40 Order number: 50004739 AM 50: for installation into cross or T-piece DN 50 Order number: 50004740 PVDF-threaded coupling With G 1/2 internal thread and G 1 external thread, maximum pressure 174 psi (12 bar) at maximum 68 F (20 C), including o-ring, internal thread, self-sealing with 1/2 NPT sensor thread: Order number: 50004381 1/2 adapter clamp Made of PVDF, for mounting CLS 19 sensor in a clamp adapter: Order number: 50043781 Measuring cables Special measuring cable CYK 71 for two electrode conductivity sensors with integrated temperature sensors, 1 low-noise coaxial line, 4 auxiliary cores at 0.75 mm 2 each with a common shield, outer diameter 0.25 (7 mm). Sold by 1 meter lengths, minimum 15 ft (5 m) Order number: 50085333 15 ft (5 m) length Order number: 50088280 30 ft (10 m) length Order number: 50088281 150 ft (50 m) length Order number: 50088284 300 ft (100 m) length Order number: 50088285 VDM junction box for cable extension, with 10 screw terminals, NEMA 4X (IP 65) Pg 13 cable entry Order number: 50003987 1/2 NPT cable entry Order number: 51500177 6

Calibration solutions Calibration set Related products Calibration solutions are precision solutions to SRM (Standard Reference Material) of NIST for qualified cablibration of conductivity measuring systems according to ISO, accuracy ± 0.5%, with temperature table. CLY 11-A: 74 µs/cm, reference temperature 77 F (25 C), 500 ml container Order number: 50081902 CLY 11-B: 149.6 µs/cm, reference temperature 77 F (25 C), 500 ml container Order number: 50081903 ConCal conductivity calibration set is for ultrapure water applications, complete, factory-calibrated measuring set with certificate, traceable to SRM of NIST and DKD, comparative measurement in ultrapure water applications of up to 10 µs/cm. 230 VAC units, order number: 50083777 115 VAC units, order number: 50083778 ConCal recalibration, for factory recalibration and new issue of calibration certificate, traceable to SRM of NIST and DKD, factory calibration procedure according to ASTM D-5391-93. Order number: 51502486 ConduMax W CLS 15 conductivity sensor for measurement in pure and ultrapure water, see CLS 15 Technical Information TI 109C/24/ae. Supplemental documentation Transmitters Calibration solutions / Calibration set Liquisys M CLM 223/253 transmitter Technical Information CLY 11 Calibration solutions Technical Information ConCal Calibration set Technical Information TI 193C/24/ae TI 162C/24/ae TI 163C/24/ae 7

For application and selection assistance, in the U.S. call 888-ENDRESS For total support of your installed base, 24 hours a day, in the U.S. call 800-642-8737 Visit us on our web site, www.us.endress.com United States, Inc. 2350 Endress Place Greenwood, IN 46143 Phone: (317) 535-7138 888-ENDRESS FAX: (317) 535-8498 Canada Canada Ltd. 1440 Graham s Lane Unit 1, Burlington ON, L7S 1W3 Phone: (905) 681-9292 800-668-3199 FAX: (905) 681-9444 Mexico Paseo del Pedregal No. 610 Col. Jardines del Pedregal 01900, Mexico D.F. Mexico Phone: (525) 568-2405 FAX: (525) 568-7459 TI 110C/24/ae/07.03 2003, Inc.