80PK-2A Type K Immersion Probe

Similar documents
80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe

Infrared Thermocouple Probe

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Tachometer. English. Users Manual

i400s Calibration Information Introduction

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Temperature Calibrator

P5510. Users Manual. Pneumatic Comparison Test Pump

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

5618B Platinum Resistance Thermometer User s Guide

Users Manual. MegOhmMeter

Users Manual. Phase Rotation Indicator

5616 Platinum Resistance Thermometer User s Guide


302+/303 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

323/324/325 Clamp Meter

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

373 Clamp Meter. Users Manual

1551A Ex/1552A Ex. Calibration Manual. Stik Thermometer

MegOhmMeter. Users Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

712 RTD Calibrator. Instruction Sheet. Introduction

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

233 True-rms Remote Display Digital Multimeter Safety Information

362 Clamp Meter. Users Manual

716 Pressure Calibrator

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

i3000s/i2000 Flex AC Current Probe

362 Clamp Meter. Users Manual

Visit us at

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Go to to register your product and find more information.

PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

TMD90A Dual Input Digital Thermometer

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

PY-11 Voltage & Continuity Tester

1000FLT. Users Manual. Fluorescent Light Tester

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

P5515, P5515-V, & P5515-EP Hydraulic Comparison Test Pump

HR-20P Pneumatically Controlled Pressure Regulator

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

HLY-1111 HEAD TEMPERATURE GAUGE

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

ODY-19-1 AIR PRESSURE GAUGE

Users Manual. Airflow Meter

11812 NE 116th Street TEL: Kirkland, WA USA FAX: INSTALLATION & SERVICE MANUAL AMFLOW PR7B Back Pressure Regulator

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

SOLAR DASH CHARGING SYSTEM USER GUIDE

SOIL RESISTIVITY TESTER

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

IMPROVED BUTTON CONTROLS NEW TOMAHAWK USER MANUAL

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

Mechanical Spiral Sensor

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

MIL-24/2600Q MIL-24/3200DQ

Installation Manual Model 3800/3810

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual

ADI-125/750 ADI-125/1500 ADI-125/2500

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

ODY-10-1 rev. B FUEL PRESSURE GAUGE

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Cabling for power, control, and video must be run to the installation site before the mount is installed.

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL


EASY CONNECT CRANE KIT Festoon Conductor Systems

Microscope light manual

HBC-20 - LED HIGH BAY

BEAMER Tilt Beam Sensor

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

SUNTURA SOLAR TRACKER

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

TACH-10 Contact / Non-Contact Tachometer

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

OWNERS MANUAL JANUARY 2007 ISO

Operating Instructions for PAC800 Battery Charger

SUNTURA HD SOLAR TRACKER

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Installation Instructions

Power. On Your Terms.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

DC to AC Power Inverters

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

DC to AC Power Inverters

Transcription:

80PK-2A Type K Immersion Probe Instruction Sheet WARNING TO AVOID ELECTRICAL SHOCK, DO NOT USE THIS PROBE WHEN VOLTAGES EXCEEDING 24V AC RMS OR 60V DC ARE PRESENT. THE PROBE TIP IS ELECTRICALLY CONNECTED TO THE OUTPUT TERMINALS. INTRODUCTION The 80PK-2A Type K Thermocouple Immersion Probe is designed for use in liquids or gels. The probe can also be used as a general purpose temperature probe. The thermocouple junction is protected from tip to handle by an Inconel sheath. The 40-inch (1-meter) cable is terminated with a Type K miniature thermocouple connector with 0.792-mm (0.312-in) pin spacing. The 80PK-2A can be used with any temperaturemeasuring instrument that is designed to accept Type K thermocouples and has a miniature connector input. NOTE The 80PK-2A is not recommended for use in food or beverage preparation. SPECIFICATIONS Type: K Standard grade Ni-Cr vs. Ni-Al (Chromel vs. Alumel) Measurement Range: -40 C to 1090 C (-40 F to 1994 F) Accuracy: (With respect to ANSI MC96.1 Standard Limits of Error) NOTE All error calculations should be done in C, then scaled to F. RANGE -40 C to 275 C (-40 F to 527 F) 275 C to 1090 C (527 F to 1994 F) ACCURACY (% of reading) ±2.2 C ±0.75% ( C) November 1987 Rev. 4, 4/02 1987-2002 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies.

Output: @ 25 C (77 F) =1.00 mv (reference junction @ 0 C) Seebeck Coefficient: @ 25 C (77 F) = 40.50 µv / C Measurement Time: (Time Constant):.75 seconds in 100 C still water at sea level pressure. Complete step change equals 5 time constants (3.75 seconds). Maximum Voltage: 24V ac rms or 60V dc Maximum Temperature of Tip: 1090 C (1994 F) Sheath: Material: Inconel 600 Dimensions: Diameter: 3.175 mm (1/8 in) Length: 20.32 cm (8 in) Grounding: Junction welded to sheath. Cable: Length: 40 inches (1 meter) Insulation: Material: PVC Maximum Temperature: 105 C (220 F) Jacket Color: Gray Conductors: Type: K Size: AWG #24 stranded (7 strands of #32) Handle: Material: Gray Hytrel Maximum Temperature: 125 C (257 F) Connector: Type: Mini-thermocouple connector with.792 mm (0.312 in) pin spacing Material: Yellow Hytrel Maximum Temperature: 125 C (257 F) Overall Length: 31.75 cm (12.5 in) from probe tip to end of cable strain relief. Protection: Class 3. Relates solely to insulation and grounding properties defined in IEC 348. MEASUREMENT CONSIDERATIONS Instrument Compatibility The 80PK-2A is compatible with any temperature-measuring instrument that accepts Type K thermocouples, has a miniature thermocouple connector, and has cold reference junction compensation. Accuracy of the temperaturemeasuring instrument must be considered along with the 80PK-2A accuracy specification to determine the overall accuracy of the combination. Temperature Limitations The probe tip of the 80PK-2A has a continuous temperature rating of 1090 C (1994 F). However the opposite end of the sheath nearest the handle should not be subjected to temperatures greater than 125 C (257 F). This is the maximum temperature limitation of the handle. Media Limitations The sheath material of the 80PK-2A is Inconel, an alloy of chromium and nickel. It has excellent resistance to oxidation and corrosion at high temperatures, but it should not be used in the presence of sulfur above 537 C (1000 F).

OPERATION Use the 80PK-2A as follows: 1. Connect the 80PK-2A to a compatible Type K temperature measuring instrument using the miniature (0.312-inch pin spacing) thermocouple connector. 2. Turn on the measuring instrument, and select the appropriate range and scale. 3. Check the readout on the measuring instrument. With no heat or cold source applied to the tip of the probe, the measuring instrument should display the ambient (room) temperature. If the instrument does not read out properly, refer to the TROUBLESHOOTING paragraphs below. MINIMIZING THERMAL SHUNTING The 80PK-2A Immersion Probe should be inserted at least 6.35 cm (2.5 in) into the environment to be measured to minimize the shunting effect of the sheath. TROUBLESHOOTING With no heat or cold applied to the probe, the measuring instrument should display the ambient temperature. If the measuring instrument does not read out properly, try the following: 1. Verify that the temperature-measuring instrument is designed to be used with Type K thermocouples. The temperature-measuring instrument should have a yellow input connector and / or be marked with a K either on the case or on the display. 2. Check for an open circuit indicator on the measuring instrument. Some temperature measuring instruments have a built-in circuit to indicate if the connected probe is open. (All Fluke Temperature-measuring instruments have this feature.) Refer to the owners manual accompanying the measuring instrument to see if this feature is available. Short the two input pins of the measuring instrument with a piece of wire. If the instrument is functioning, it should indicate the ambient temperature. 3. If you suspect a broken connection, use an ordinary ohmmeter to read the continuity of the probe from pin to pin. The ohmmeter should read 10 ohms or less if there is continuity. SCALE CONVERSIONS Use the following equation to convert C to F: ( C x 1.8) + 32 = F Use the following equation to convert F to C: ( F 32) x 0.5556 = C PROBE MOUNTING GROOVE The probe finger guard contains a groove to simplify mounting the probe in a fixed position. The figure below shows nominal dimensions for the finger guard and groove, and suggests a temporary quick mounting method. However, any mounting method should be carefully designed to prevent damage to the probe or the measured medium. CAUTION The handle and plug of the probe are made of material that may deteriorate when exposed to some solvents on a long-term basis.

1.6 mm (.062 in) 20.3 mm (.80 in) 23.6 mm (.930 in) CLIP NOT INCLUDED WITH PROBE FINGERS MAY BE BENT UP SLIGHTLY FOR PROBE RETENTION

LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke s warranty obligation is limited, at Fluke s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not effect the validity or enforceability of any other provision. 5/94

For application or operation assistance, or information on Fluke products, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke s Web site at www.fluke.com. Address correspondence to: Fluke Corporation Fluke EuropeB.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven, USA The Netherlands