The Battery is a client module in the Cabinet Control. It is a backup/ups module which

Similar documents
Uninterruptible Power Supplies

Electronic Circuit Breaker ESS20-0..

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Technical Documentation

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Solid State Relays contactor with Integrated Fuse Type RGC1F

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Wireless Water Rope Sensor

Data sheet... W-Series WPE 4

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Datasheet. W-series terminal with clamping yoke connection WDU 2.5 RT

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Electronic Circuit Breaker ESS20

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Data sheet. W-Series WDU 4 SL/EN

Operating Instructions (Translation)

User Manual. Solar Charge Controller 3KW

Datasheet. W-series terminal with clamping yoke connection WDU 4

Data sheet TERMSERIES TRZ 120VUC 1CO

Foreword

Datasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

USERS MANUAL MCD REMOTE OPERATOR

Technical Specification SENTINEL PRO

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

2-channel analog input module; Pt100 / RTD; for resistance sensors

1.0 Features and Description

Master MPS kva kva 3:1 3:3 VFI TYPE

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

Data sheet... W terminal earth terminal WPE 4

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

PKS-FD Servo System

INSTALLATION INSTRUCTIONS

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Master Plus kva

HID-PV m PGJ5 20/P CDM LPF

Dry Contact Closure Interface

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Installation Guidance

CX-SERIES ADVANCED BATTERY CHARGER

KNC-SRV-FD123-CA-000 Series Servo Driver

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Intelligent DC UPS Module

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Uninterruptible Power Systems. SDU DC Series

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

IGLOO IGLOO EASY INSTRUCTION MANUAL

GS2 Series - Introduction

Type 2REX-A. Oil & Gas / Heavy Industry

User Manual Solar Charge Controller 3KW

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Aurora Single Phase Emergency Lighting Inverters

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Spyder BACnet Programmable Controllers

Heat Meter Integrator

V4 Cordless Lamp System User Guide

Manual. EN Appendix. VE.Bus BMS

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

POWERWARE User s Guide VA.

Wireless Digital Compass

BRAVER UPS. (Uninterruptible Power System) User s Manual

Pure Sine Wave Inverter User Manual

Wireless Accelerometer - Vibration Meter

Installation Guide B-BOX Pro2.5 ~ 10.0

Outdoor Enclosure Power System ENC X100MP48F20

MS General Information Extended Product Type: MS

Infilex ZM Zone Manager Model WY5122

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

DC Master 24/ A

V-D2425 and V-D2440 Digital Clock

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

KNC-PKS-FD S-AAK-DKH

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

Installation and Operations Manual

Owner s Manual. DC-DC Step Down Converter

Transcription:

LFC7530 Product Guide Battery The Battery is a client module in the Cabinet Control. It is a backup/ups module which is used for supplying other modules with emergency power in the event of power failure. All modules in the Cabinet Control incorporate an A-Bus interface which is based on the industrially proven RS-485 technology. The A-Bus interface is used for power supply and for direct communication between the modules. If the Battery is installed together with an SCU, it will be recharged with power as long as the battery is supplied with 12 V from the A-Bus interface. If the main power fails, the Battery will instantaneously take over the power supply of the A-Bus. This enables the SCU to store data and send a main power failure alarm to the central server via GPRS/SMS before it shuts down safely. For more detailed information, see the specific manuals and guides.

LFC7030 Dimensional drawing Functional specifications A-Bus A-Bus client module, check SCU specification for details. 86 mm (3.39 in) Battery Initial capacity of 950 mah (7.4 V). Li-Polymer rechargeable, incl. safety circuit Reliability & Maintainability Software upgrade The software on the Battery can be updated remotely from the central server. 35 mm (1.38 in) 58 mm (2.28 in) Functionality Installation of new software New software is transferred without interrupting the normal functionality of the Battery. When the software has been transferred, the integrity of the software is checked and the software is installed. Communication A-Bus two-way communication with A-Bus masters. Self-test A built-in self-test is performed after power-up. Battery charging Battery charging is performed autonomously when the battery is not full and the temperature is in the range of 0 to 40 C (32 to 104 F). Watchdog and brown-out reset Watchdog and brown-out reset ensure that the system is up and running at all times. Auto discovery The module is automatically discovered by the SCU. In case a module is disconnected from the SCU, this is reported to the server application and the module is listed as missing. If the module is reconnected to the SCU or another SCU, it will be rediscovered by the system. LED Status LED (green): indicates whether the A-Bus is up and running. Battery LED (red): indicates whether the Battery module is charging or supplying the SCU with backup power in the event of power failure. 2 Specification Sheet - LFC7530 Battery

Installation The Battery should be protected from dust and water, preferably by enclosing the system in a metal IP class 65 (NEMA type 4) outdoor cabinet. Use shielded cables, with the shield connected to GND (pins 5 and 10 for the A-bus). If the use of shielded cables is not possible keep the cable length as short as possible and avoid placement close to sources of interference, such as RF antennas and mains power lines. Wiring A-Bus connection: Shielded twisted pair (2x2) cable Max. 3 m (10 ft) VCC A B GND GND B A VCC A-Bus cable Use shielded twisted pair (2x2) cable The Battery module can be connected to any master module in the Cabinet (the SCU). Double connections on the A-Bus makes daisy-chaining of the signals easy. For detailed information, see wiring diagrams. 1 2 A-Bus cable length < 3 m (10 ft) Battery ON Battery ON Battery turn on To minimize self-discharge the module is delivered with the battery disconnected. To enable the battery, terminal 1 and 2 of the battery connection (ON) must be connected to each other. Keep this bridge wire short. Battery connection / disconnection Terminals: 0.5 mm 2 (AWG 20) B Attention The Lithium Ion battery is not userreplaceable. Risk of explosion if the battery is replaced by an incorrect type. Disposal of used batteries must be in accordance with local environmental regulations. Specification Sheet - LFC7530 Battery 3

Specifications Environmental conditions Connections A Be careful, temperature range limited by battery! Storage temperature -20 to 60 C (-4 to 140 F) Operating -20 to 55 C (-4 to 131 F) temperature A-Bus and Battery connector 0.14 to 0.5 mm 2 (AWG 26 to 20) solid/ stranded; copper conductors only, wire rating 65 C (149 F) min.; wire strip length: 4.5 mm; screwdriver, bladed, size 0.4 x 2.0; tightening torque: min 0.12 Nm, max 0.15 Nm (1.1 to 1.3 lb in) Humidity 45% ±20% (non-condensing) Standards and approvals Charge Retention/ Storage [%]: 6 months at -20 to 25 C (-4 to 77 F) 3 months at -20 to 35 C (-4 to 95 F) 1 month at -20 to 45 C (-4 to 113 F) 2006/95/EC, Low Voltage Directive (LVD) 2004/108/EC, EMC Directive 1999/5/EC, R&TTE Directive 2002/95/EC, RoHS Directive 2006/121/EC, REACH directive Supply characteristics Input voltage 12 Vdc via A-Bus 4EE5 Current (battery charged) Typical 20 ma Maximum 55 ma Current (during charge) 120 ma Output current Maximum 500 ma Mechanical Housing Top part Gray (RAL 7035) Lexan 940 Base part Black (RAL 7021) Noryl VO 1550 Coating Conformal coated Mounting DIN-rail (EN50022) Weight 90 g (3.2 oz) 4 Specification Sheet - LFC7530 Battery

Packing data Type Box dimensions Qty Material Weight net gross LFC7530 395 x 290 x 205 mm (15.6 x 11.4 x 8.1 in) 60 Cardboard 5.4 kg (11.9 lb) 6.3 kg (13.9 lb) Ordering Data Type MOQ Ordering number EAN code level 1 EAN code level 3 EOC LFC7530/00 1 9137 003 41303 8727900 947625 8727900 947632 947625 00 2012-2018 Philips Lighting Holding B.V., all rights reserved. Specifications are subject to change without notice. Trademarks are the property of Philips Lighting Holding B.V. or their respective owners. 3222 636 36224 9 May 2018 www.lighting.philips.com