POWER DISTRIUTION MODULE - 8 POSITION - SELED This module can be fitted with a mixture of 80 style components such as Mini fuses, mini circuit breakers, mini diodes, mini resistors and ISO 80 relays. It s compact size means it can be installed anywhere thereby eliminating excessive wiring in harnesses. Voltage: 3V Rating: 10 max* (100 when following SE guidelines) Combined maximum current of positions 1 & is 60 for fuses / 30 for circuit breakers. The same applies for positions 3 & 4. Module is rated 50 max when fitted with an ISO 80 micro relay. Module Contents: Module includes cover, base with seal & bracket. Terminal Capacity: 8 terminals on a layout matrix of ( x 4). Terminals: Delphi Metri-Pack 80 Female Sealed TNGED. Temperature: -40 C to +15 C Cover: 94V0 Clear Polycarbonate. Short or tall cover options. ody: 94V0 Thermoplastic. lack, other colour options available. Side racket Standard: Zinc plated steel w/ chromate finish. racket Options: End bracket or plastic pin, contact sales. Ingress Protection Rating: IP66 (Valid when properly installed with cover, cable seals and cavity plugs). Cavity Plugs: Required to fill unused output cavities for ingress protection. Silicone material. Cable Seals: Please check the overall diameter of your cable before ordering cable seals. Silicone material UL94-V0 Terminal Tools: Terminal crimping & removal tools page 144. Pack Size: 1, 10, 100 Notes: *Please contact sales for max amperage guidelines. s, circuit breakers and relays are optional extras. CFH-SS (Short Cover) ussmann IP66 CFH-LS (Tall Cover) PDMKITLS1 PDMKITSS1 Kit - Tall Cover *, ody, Side racket, 8 x Terminals, 8 x Seals, 4 x Plugs & TP. Kit - Short Cover, ody, Side racket, 8 x Terminals, 8 x Seals, 4 x Plugs & TP. NEW NEW CFH-LS ody, Side racket & Tall Cover* - No Terminals, Cables or Seals. CFH-SS ody, Side racket & Short Cover - No Terminals, Cables or Seals. Note: *Tall cover is required when fitting relays & breakers. PDM Module Kits - see page. PDMKITLS1 Loose Terminals Kit PDMKITSS1 Terminated Cables Kit Optional ccessories - see pages 3 & 4. dd these parts to complete your installation. Mini s, Mini Resistors, Mini Diodes, Mini Shunts & Mini lade Circuit reakers. ISO 80 Ultra Micro Relays, ISO 80 Micro Relays. Pre-Terminated Cables, Terminals, Cable Seals, Cavity Plugs, etc. Page: 1
POWER DISTRIUTION MODULE - 8 POSITION - SELED 8 Position Module with Tall Cover & Terminal Kit ussmann PDMKITLS1 Tall Cover Kit PDMKITLS1 Kit Contents: - CFH-LS block with cover, bracket & secondary lock - 8 x terminals (.0-3.0mm ). - 8 x cable seals (.81-3.49mm dia. cable). - 4 x cavity plugs Note: Tall cover is required when fitting relays & breakers. 8 Position Module with Short Cover & Terminal Kit PDMKITLS1 Short Cover Kit PDMKITSS1 Kit Contents: - CFH-LS block with cover, bracket & secondary lock - 8 x terminals (.0-3.0mm ). - 8 x cable seals (.81-3.49mm dia. cable). - 4 x cavity plugs Optional ccessories - see page 4. Terminal Crimp Tool. Terminal Extractor. Pre-Terminated Cables. Cable Joiners. Terminals. Cable Seals. Cavity Plugs. Page:
PLUG-IN COMPONENTS Minifuse 3VDC MIN00 MIN003 MIN004 MIN005 MIN07.5 MIN010 MIN015 MIN00 MIN05 MIN030 MIND003-3V MIND005-3V MIND07.5-3V MIND010-3V MIND015-3V MIND00-3V MIND05-3V MIND030-3V mpere Rating 3 4 5 7.5 10 15 0 5 30 Minifuse 3VDC (Indicating) mpererating 3 5 7.5 10 15 0 5 30 14VDC utomatic TI 1105-00 1175-00 1110-00 1115-00 110-00 115-00 1130-00 14VDC Modified TII 105-00 175-00 110-00 115-00 10-00 15-00 130-00 mpere Rating 5 7.5 10 15 0 5 30 mpere Rating 5 7.5 10 15 0 5 30 Prolec Circuit reaker (utomatic Reset) Circuit reaker (Modified Reset) Minifuse 3VDC ssortment MINI-KIT 35 Piece fuse kit assortment. This fuse kit contains; MIN005 x 5pcs MIN07.5 x 5pcs MIN010 x 5pcs MIN015 x 5pcs MIN00 x 5pcs MIN05 x 5pcs MIN030 x 5pcs Mini Devices 901-1.5 90-68 Product Transorb Resistor Circuit reaker (Manual Reset) 8VDC Manual TIII 3305-00 3375-00 3310-00 3315-00 330-00 335-00 3330-00 Mini Diodes 0400104P 903-6 903-6V mpere Rating 5 7.5 10 15 0 5 30 Diode Diode Diode Ultra Micro Relays (ISO 80) 3031HCR11 3031HCR14 1V Normally Open 4 pin (SPST) 4V Normally Open 4 pin (SPST) Micro Relays (ISO 80) 3011CR11 3011CR14 3011CCR11 3011CCR14 1V Normally Open 4 pin (SPST) 4V Normally Open 4 pin (SPST) 1V Change Over 5 pin (SPDT) 4V Change Over 5 pin (SPDT) i Search these part numbers on our website for datasheets. Page: 3
TERMINLS, CLE SELS, CVITY PLUG & SECONDRY LOCK Delphi Metri-Pack 80 ccessories TERMINLS: TNGED Female sealed - Tin rass /Tin plated CLE SELS: Silicone CVITY PLUG: Silicone 108401 1077411 119493 1077413 Wire (WG) # - #0 # 18 - # 16 # 14 - # 1 #10 Wire (mm ) 0.35-0.5 0.80-1.0.0-3.0 5.0 1534983 153498 1534980 1534981 Cable D ia.(mm) 1.70-1.9.85 -.03 3.49 -.81 4.30-3.45 Colour Dark Red Green Grey lue 1010300 3006-TP Secondary Lock (TP) Secures Terminals in C onnector. Secondary Lock fits to base of the connector. PRE-SSEMLED CLES & UTT SPLICE CONNECTOR Packard 80 Metri-Pack Female Sealed Tanged Terminal C.0X300TS1T C.0X300TST C.0X85TS1TJ 19164-0044 Output Cable Output Cable Jumper Cable utt Connector Colour Red lue Red lue Wire Size (mm ) 1.84 1.84 1.84 1.0 to.0 Wire Length (mm) 305 305 90 N/ Pack Qty 10 10 1 10 Red Output Cable Red Jumper Cable lue Output Cable utt Splice Connector TERMINL TOOLS Terminal Crimp Tool CRIMPER-03 Delphi Metri-Pack 80 & Tyco MP MCP.8 terminals. Terminal Removal Tool 109449 Prolec Extracts Delphi Metri-Pack 80 terminals & other types. Need help using this crimp tool? Scan the QR code to view instructions. Scan this QR Code for more information QR Code: 8001 i Search these part numbers on our website for datasheets. Page: 4
POWER DISTRIUTION MODULE - 8 POSITION - cont'd. ussmann CFH-LS (Long cover) CFH-SS (Short cover) Dimensions in MM (optional extra) Page: 5
POWER DISTRIUTION MODULE - 8 POSITION - cont'd. ussmann Component Layout Samples (CFH-SS) Short cover allows only short components to be fitted ie. Mini fuses, diodes, resistors etc. Empty position Empty Module (8 positions) 4 Mini s / Circuit reakers Component Layout Samples (CFH-LS) Tall cover allows circuit breakers and relays to also be fitted. Ultra Micro Relay Empty Module (8 positions) 4 Mini s / Circuit reakers 1 Ultra Micro Relay & Mini s / Circuit reakers Ultra Micro Relay Ultra Micro Relay Micro Relay Empty position Ultra Micro Relays 1 Micro Relay Component Loading Options: 4 x Mini fuses or Mini lade circuit breakers or combination. x ISO 80 Ultra Micro Relays (4 pin only). 1 x ISO 80 Micro Relay (4 or 5 pin). x Mini fuses or Mini lade circuit breakers or combination & 1 x ISO 80 Ultra Micro Relay (4 pin only). Note: *Tall cover is required when fitting relays & breakers. Component information: 1. s, reakers, diodes etc. use positions (1x).. Ultra Micro Relays used 4 positions (x). 3. Micro Relays use 6 positions (3x). 4. Mini relays do NOT fit into this unit. 5. Flashers do NOT fit into this unit. Page: 6