Technical Specifications. Symmetra PX kw 208 V

Similar documents
Symmetra PX. Technical Specifications 07/

Technical Specifications

Installation Guide. Marine Filter SURT023M SURT024M

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation Power Management Unit Battery Cables and Battery Harness

Broadband PowerShield. CP27U Models. User Manual

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Symmetra PX. 20 kw 208 V. Technical Specifications 01/2016.

EPS Technical Specifications 06/2015.

Installation and Operation

Single and Parallel Installation

Single and Parallel Installation. MGE Galaxy kva 208/220 V

Galaxy : kva 380/400/415 V 3: kva 220/230/240 V. Technical Specifications 04/

Symmetra PX kw 208 V. Installation 01/

Symmetra PX 96 and 160 kw

10 Year Limited Warranty

Power Distribution Units

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Power. On Your Terms.

PVI 60KW, PVI 82KW, PVI 95KW

Power Distribution Units AP9560 & AP9561

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

END USER TERMS OF USE

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Installation and Operation

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Toro Sprayer Calibration Tool

SUA1000I-IN / SUA1500I-IN 230 VAC

Galaxy Technical Specifications 05/

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation Manual & Warranty

II DISTRIBUTION & SUBSTATION TYPE C

Single and Parallel Installation

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

G3PE-Single-phase. Solid State Relays for Heaters

Cabling for power, control, and video must be run to the installation site before the mount is installed.

MaxLite LED Linear HighBay Fixtures

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

WEB CONTROL PRODUCTS

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Technical Specifications. MGE Galaxy kva 380/400/415 V

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Vertabelo Academy. Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

SPC-PANEL Simplex, Single Phase Pump Control Panel

Galaxy VX. 480 V UPS System Technical Specifications 07/

HR-20P Pneumatically Controlled Pressure Regulator

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Users Guide for Ac-sync

Installation and Operation

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Traffic Logix SafePace 450 Radar Speed Sign

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

StormPro BA Series Sump Pump

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

MaxLite StaxMax LED Flood Lights

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Operation and Maintenance

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

SUNTURA SOLAR TRACKER

Web Volume Control Model WV220

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

Pump Installation and Service Manual HRS Hydromatic Retractable System

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Features and Benefits

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

4-Ton Electric Log Splitter

A Member of the. Integrated Metering Technologies

INSTALL GUIDE Dodge/RAM 5.7L HEMI

StormPro BCV400 Sewage Ejector Pump

Galaxy VX. 380 V, 400 V, 415, and 440 V UPS System Technical Specifications 12/

SUNTURA HD SOLAR TRACKER

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

AD-7 THERMAL INDICATING AMMETER

High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual

DC to AC Power Inverters

Service Guide JATCO Environmental Protection Tank Model J-7000

Transcription:

Technical Specifications Symmetra PX 10 40 kw 208 V

American Power Conversion Legal Disclaimer The information presented in this manual is not warranted by the American Power Conversion Corporation to be authoriative, error free, or complete. This publication is not meant to be a substitute for detailed operational and site specific development plan. Therefore, American Power Conversion Corporation assumes no liability for damages, violations of codes, improper installation, system failures, or any other problems that could arise based on the use of this Publication. The information contained in this Publication is provided as is and has been prepared solely for the purpose of evaluating data center design and construction. This Publication has been compiled in good faith by American Power Conversion Corporation. However, no presentation is made or warranty, either express or implied, as to the completeness or accuracy of the information this Publication contains. NO EVENT SHALL AMERICAN POWER CONVERSION CORPORATION BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, CONTRACT, REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION) RESULTING FROM, ARISING OUT, OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS PUBLICATION OR THE CONTENT, EVEN IF AMERICAN POWER CONVERSION CORPORATION HAS BEEN EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AMERICAN POWER CONVERSION CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME WITHOUT NOTICE. Copyright, intellectual, and all other proprietary rights in the content (including but not limited to software, audio, video, text, and photographs) rests with American Power Conversion Corporation or its licensors. All rights in the content not expressly granted herein are reserved. No rights of any kind are licensed or assigned or shall otherwise pass to persons accessing this information. This Publication shall not be for resale in whole or in part.

Table of Contents Technical Data... 1 Model List... 1 Efficiency... 1 Efficiency Curves... 1 Batteries... 2 Efficiency DC to AC... 2 Battery Run-Times APC Solutions... 3 Battery Discharge Current... 4 End of Discharge Voltage... 5 Battery Gassing Rates... 5 Battery Material Safety Data Sheet... 5 Emergency Power Off... 6 Compliance... 6 Facility Planning... 7 AC Input Specifications... 7 AC Bypass Input Specifications... 7 AC Output Specifications... 7 Battery Specifications... 8 Recommended Cable Sizes... 8 Recommended Cable Logs and Crimping Tool... 9 Overcurrent Protective Devices in Single Systems... 9 Physical...10 Weights and dimensions...10 Shipping Weights and dimensions...10 Environmental...10 Heat Dissipation...10 Drawings...11 Symmetra PX 40 kw UPS with ISX PDU...12 Options...13 Hardware Options...13 Battery Systems...13 Symmetra Accessories...13 UPS Network Management Cards...13 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications i

Symmetra Power Module...13 Configurable Power Distribution...13 Maintenance Bypass Panel...13 Configuration Options...14 APC by Schneider Electric Limited Factory Warranty...15 Three Phase Power Products or Cooling Solutions One-Year Factory Warranty...15 Terms of Warranty...15 Non-transferable Warranty...15 Assignment of Warranties...15 Drawings, Descriptions...15 Exclusions...15 Warranty Claims...16 ii Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

Technical Data Model List Symmetra PX 10 kw Scalable to 40 kw N+1, 208 V Symmetra PX 20 kw Scalable to 40 kw N+1, 208 V Symmetra PX 30 kw Scalable to 40 kw N+1, 208 V Symmetra PX 40 kw Scalable to 40 kw N+1, 208 V Efficiency System 25% load 50% load 75% load 100% load Symmetra PX 10 kw 87.3 90.6 91.2 91.1 Symmetra PX 20 kw 89.5 91.9 92.2 92.0 Symmetra PX 30 kw 90.4 92.4 92.6 92.3 Symmetra PX 40 kw 90.8 92.7 92.7 92.4 Efficiency Curves Symmetra PX 10 kw Scalable to 40 kw Symmetra PX 20 kw Scalable to 40 kw 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 1

Symmetra PX 30 kw Scalable to 40 kw Symmetra PX 40 kw Scalable to 40 kw Batteries Efficiency DC to AC Efficiency at nominal battery voltage (%) Symmetra PX 10 kw Scalable to 40 kw Symmetra PX 20 kw Scalable to 40 kw Symmetra PX 30 kw Scalable to 40 kw 89% 89% 89% 89% Symmetra PX 40 kw 2 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

Battery Run-Times APC Solutions Symmetra PX 10 kw Scalable to 40 kw Curve A B C D E Part Number(s) SY10K40F SY10K40F + (1)SYBT4 SY10K40F + (2)SYBT4 SY10K40F + (3)SYBT4 SY10K40F + (1)SYCFXR8 8 Symmetra PX 20 kw Scalable to 40 kw Curve A B C D E Part Number(s) SY20K40F SY20K40F + (1)SYBT4 SY20K40F + (2)SYBT4 SY20K40F + (1)SYCFXR8 8 SY20K40F + (2)SYCFXR8 8 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 3

Symmetra PX 30 kw Scalable to 40 kw Curve A B C D E Part Number(s) SY30K40F SY30K40F + (1)SYBT4 SY30K40F + (1)SYCFXR8 8 SY30K40F + (2)SYCFXR8 8 SY30K40F + (3)SYCFXR8 8 Symmetra PX 40 kw Curve A B C D E Part Number(s) SY40K40F SY40K40F + (1)SYCFXR8 8 SY40K40F + (2)SYCFXR8 8 SY40K40F + (3)SYCFXR8 8 SY40K40F + (4)SYCFXR8 8 Battery Discharge Current Symmetra PX 40 kw Ibat @ Vbat nominal, 100% load 114.5 Ibat @ Vbat min, 100% load 139.1 4 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

End of Discharge Voltage Battery Gassing Rates Note: We recommend that room ventilation is based on maximum values. Gassing rate cc/hr (ml/hr) per battery string/row of 4 batteries Typical Maximum 24 48 Battery Material Safety Data Sheet Note: For Material Safety Data Sheet (MSDS), go to http://nam-en.apc.com/app/answers/detail/a_id/564/kw/msds. 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 5

Emergency Power Off Compliance FCC Part 15 Class A UL 1778 cul Listed 6 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

Facility Planning AC Input Specifications Note: All current values are based on a 40 kw maximum configuration. Connection type 40 kw System 3PH + N + G Input voltage (V) 3 Phase 208 V (166 V - 240 V) Input frequency (Hz) 40 70 THDI Nominal input current (A) 123 Maximum input current continuous, at minimum mains voltage (A) < 6% at full load 154 Input current protection (external to UPS, not supplied) 1 175 Maximum Short Circuit Withstand (ka) 30 1 Input: 175 Amp. 3-Pole AC circuit breaker with 30 kaic. Note: If your installation does not include an Isolation Transformer and a MBP (optional equipment), use a 175 Amp Class J current limiting fuse on each input phase. AC Bypass Input Specifications 40 kw System Connection type 3PH + N + G Input frequency (Hz) 40 70 Nominal input current (A) 111 AC Output Specifications Output voltage Connection type Overload capacity 208 V Nominal output current (A) 111 Maximum output current (in bypass only at 125% overload, per phase) (A) 3PH + N + G 150% for 30 seconds (normal operation) 150% for 30 seconds (battery operation) 125% continuous (bypass operation) 1000% for 500 ms (bypass operation) 139 Neutral output current with 100% switch mode load (A) 1 192 Output current protection external to UPS, not 150 supplied (A) 2 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 7

Output frequency (on line, in bypass) 3 Output frequency (on battery) (Hz) 50/60 Synchronized to input over the range 57 Hz 63 Hz Slew rate (Hz/s) Programmable to 0.25, 0.5, 1, 2, 4, and 6 THDU < 2% linear < 5% non-linear 1 Neutral output wires: rate for 173% of output phase current if feeding all Switch Mode Power Supply loads without power factor correction. 2 Output: 150 Amp 3-pole AC circuit breaker with 30 kaic. 3 The following ranges can be selected: 40-60 Hz, 47-53 Hz, 49.9-50.1 Hz, 50-70 Hz, 57-63 Hz, and 59.9 60.1 Hz Battery Specifications Type VRLA Nominal voltage (VDC) +/- 192 (96 cells at 2 V) Float voltage (VDC) +/- 219 (96 cells at 2.28 V) 1 End of discharge voltage at full load (VDC) +/- 158 (96 cells at 1.65 V) Maximum charging power Typical recharge time (to 80% of capacity) 4 kw (5 kw if redundant Power Module is present). It may drop to lower vales at low AC Mains. 3.5 hours 1 Float voltage is temperature compensated. It is decreased 320 mv per ºC for temperatures higher than 20ºC Recommended Cable Sizes Caution: All wiring must comply with all national and/or local electrical code. Note: The recommended cable sizes are based in an environment with an ambient temperature of 40 C (104 F) Note: Neutral output wires: rate for 173% of output phase current if feeding all Switch Mode Power Supply loads without power factor correction. Note: Ground wires: sized in accordance with NEC Article 250-122 and Table 250-122. Note: Maximum cable sizes: 250 kcmil. Input Output 2/0 AWG 90 C (194 F) rated copper wire. 1/0 AWG 90 C (194 F) rated copper wire 8 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

Recommended Cable Logs and Crimping Tool Recommended cable lugs and crimping tools. Manufacturer: Framatome Connectors International (FCI). Cable Size (AWG) Terminal bolt diameter: 8 mm Cable Lug Type Crimping Tool Die 8 YA8CL2TC38 MD7-34R W8CVT 6 YA6CL2TC38 MD7-34R W5CVT 4 YA4CL2TC38 MD7-34R W4CVT 3 YA3CL2TC38 Y35 U3CRT 2 YA2CL2TC38 MD7-34R W2CVT 1 YA1CL2TC38 MD7-34R W1CVT 1/0 YA25CL2TC38 MD7-34R W25VT 2/0 YA26CL2TC38 MD7-34R W26VT 3/0 YA27CL2TC38 MD7-34R W27VT 4/0 YA28CL2TC38 MD7-34R W28VT Overcurrent Protective Devices in Single Systems Symmetra PX 40 kw Utility/mains input 175 Amp 3-Pole AC circuit breaker with 30 kaic 1 Output 150 Amp 3-pole AC circuit breaker with 30 kaic 1 If your installation does not include an Isolation Transformer and a Maintenance Bypass Panel (optional), use a 175 Amp class J current limiting fuse on each input phase. 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 9

Physical Weights and dimensions UPS Weight kg (lbs) Height mm (in) Width mm (in) Depth mm (in) Symmetra PX 10kW Scalable to 40kW N+1, 208V Symmetra PX 20kW Scalable to 40kW N+1, 208V Symmetra PX 30kW Scalable to 40kW N+1, 208V Symmetra PX 40kW Scalable to 40kW N+1, 208V 406.18 (895) 2070 (81.5) 600 (23.62) 902 (35.50) 529.55 (1165) 2070 (81.5) 600 (23.62) 902 (35.50) 652.27 (1435) 2070 (81.5) 600 (23.62) 902 (35.50) 775 (1705) 2070 (81.5) 600 (23.62) 902 (35.50) Shipping Weights and dimensions UPS Weight kg (lbs) Height mm (in) Width mm (in) Depth mm (in) Symmetra PX 10kW Scalable to 40kW N+1, 208V Symmetra PX 20kW Scalable to 40kW N+1, 208V Symmetra PX 30kW Scalable to 40kW N+1, 208V Symmetra PX 40kW Scalable to 40kW N+1, 208V 453.18 (997) 2311 (91) 749 (29.5) 1054 (41.5) 586.82 (1291) 2311 (91) 749 (29.5) 1054 (41.5) 720.45 (1585) 2311 (91) 749 (29.5) 1054 (41.5) 854.1 (1879) 2311 (91) 749 (29.5) 1054 (41.5) Environmental Operating temperature 0-40 C (32-104 F) Storage temperature -15-40 C (5-104 F) Operating relative humidity 0-95% Storage relative humidity 0-95% Operating elevation 0-3000 meters (0-10000 feet) Storage elevation 0-15000 meters (0-50000 feet) Audible noise 1 meter from surface of unit 64 dba Protection Class NEMA 1 Colour Black Heat Dissipation Heat dissipation kw (BTU/hr) Symmetra PX 10kW Scalable to 40kW Symmetra PX 20kW Scalable to 40kW Symmetra PX 30kW Scalable to 40kW 3381 5942 8913 11611 Symmetra PX 40kW Scalable to 40kW 10 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

Drawings Note: A comprehensive set of drawings is available on the engineering website at www.engineer.apc.com. Note: These drawings are for reference ONLY subject to change without notice. 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 11

Symmetra PX 40 kw UPS with ISX PDU 12 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

Options Hardware Options Battery Systems Battery Module for Symmetra PX, Smart-UPS VT or Galaxy 3500 (SYBT4) Symmetra PX 40 kw Extended Run Battery Frame (SYCFXR8) Symmetra PX 40 KW Extended Run Battery Frame with 8 Battery Modules & Startup (SYCFXR8 8) Symmetra PX40 KW Extended Run Battery Frame with Startup (SYCFXR8S) Symmetra Accessories Emergency Power Off (EPO) (EPW9) UPS Network Management Cards UPS Network Management Card 2 (AP9630) UPS Network Management Card 2 with Environmental Monitoring (AP9631) Symmetra Power Module Symmetra PX 10kW Power Module, 208V (SYMP10KF) Configurable Power Distribution InfraStruxure PDU 208 V:208 V W/ MBP (PD40F6FK1-M) InfraStruxure PDU 40 kw 208V:208V Transformerless W/ MBP (PDRPPNX10-M) InfraStruxure PDU 40 kw 480V:208V W/ MBP (PD40G6FK1-M) InfraStruxure PDU 40 kw 600V:208V W/ MBP (PD40L6FK1-M) Maintenance Bypass Panel APC 40 KW 208 V 1 MOD. 1 Maintenance Bypass Panel (SBP40KFC1M1) 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 13

Configuration Options Internal N+0 or N+1 redundancy Top or bottom feed Extended battery runtime Line-up/remote extended battery runtime enclosures StruxureWare Central compatible Secondary Network Management Card SmartSlot device management cards 40 kw InfraStruxure PDU with Maintenance Bypass Panel and optional isolation transformer Battery Breaker Box Service Bypass Panel 14 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

APC by Schneider Electric Limited Factory Warranty Three Phase Power Products or Cooling Solutions One-Year Factory Warranty The limited warranty provided by APC by Schneider Electric (APC ) in this Statement of Limited Factory Warranty applies only to products you purchase for your commercial or industrial use in the ordinary course of your business. Terms of Warranty American Power Conversion warrants that the product shall be free from defects in materials and workmanship for a period of one year from the date of product start-up when start-up is performed by APC authorized service personnel and occurs within six months of The APC shipment date. This warranty covers repairing or replacing any defective parts including on-site labor and travel. In the event that the product fails to meet the foregoing warranty criteria, the warranty covers repairing or replacing defective parts at the sole discretion of APC for a period of one year from the shipment date. For APC cooling solutions, this warranty does not cover circuit breaker resetting, loss of refrigerant, consumables, or preventive maintenance items. Repair or replacement of a defective product or part thereof does not extend the original warranty period. Any parts furnished under this warranty may be new or factory-remanufactured. Non-transferable Warranty This warranty is extended to the first person, firm, association or corporation (herein referred to by You or Your ) for whom the APC product specified herein has been purchased. This warranty is not transferable or assignable without the prior written permission of APC. Assignment of Warranties APC will assign you any warranties which are made by manufacturers and suppliers of components of the APC product and which are assignable. Any such warranties are assigned AS IS and APC makes no representation as to the effectiveness or extent of such warranties, assumes no responsibility for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this Warranty to such components. Drawings, Descriptions APC warrants for the warranty period and on the terms of the warranty set forth herein that the APC product will substantially conform to the descriptions contained in the APC Official Published Specifications or any of the drawings certified and agreed to by contract with APC if applicable thereto ( Specifications ). It is understood that the Specifications are not warranties of performance and not warranties of fitness for a particular purpose. Exclusions APC shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper 990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 15

installation or testing. Further APC shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair, installation, start-up by non-apc designated personnel, a change in location or operating use, exposure to the elements, Acts of God, fire, theft, or installation contrary to APC recommendations or specifications or in any event if the APC serial number has been altered, defaced, or removed, or any other cause beyond the range of the intended use. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. APC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. APC EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, APC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. APC WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES, SPECIFICALLY, APC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. NO SALESMAN, EMPLOYEE OR AGENT OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT. Warranty Claims Customers with warranty claims issues may access the APC worldwide customer support network through the APC web site: http://www.apc.com/support/contact/. Select your country from the country selection pull-down menu. Open the Support tab at the top of the web page to obtain contact information for customer support in your region. 16 Symmetra PX 10 40 kw 208 V Technical Specifications 990 4641 001

990 4641 001 Symmetra PX 10 40 kw 208 V Technical Specifications 17

Worldwide Customer Support Customer support is available at no charge via e-mail or telephone. Contact information is available at www.apc.com/support/contact APC by Schneider Electric. APC and the APC logo are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners. 990 4641 001 03/2012