EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

Similar documents
DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Air Cooled Packaged Units

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

Ducted Split System Air Conditioners

Ducted Split System Air Conditioners

The World Leading Air-conditioning Company

Highline 260i EC Waterside Fan Coil Unit

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Air Cooled Packaged Units Technical Data

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

CHILLED WATER FAN-COIL UNITS

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

CENTRIFUGAL FAN COIL UNIT VCE

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Fan - Powered Terminal Unit Series Flow

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

IDENTIFICATION ACCESSORIES DESCRIPTION

Technical Sales Guide # 040 YDFC 0 1 Page 2

FCVC Series VERTICAL FAN COILS

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

(click on page links below) XAL-2C Technical Data 1. XAL-4C Technical Data 3

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

BRIZA 22 HYBRID HEATING & COOLING

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Ocelot vertical fan coil unit

Swegon PACIFIC. Integrated climate beam

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

OUTDOOR UNIT CONTROLLER (OUC)

SINGLE DUCT TERMINAL UNITS

Complete HVAC Capability

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Commercial Blower Coil Air Handlers

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

FDCLP2 Constant Volume Series Flow, Low Profile

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

NEW Slimpak EC Box Fan (SLPT EC)

BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE TECHNICAL CATALOGUE

High Static Fan Coil Units YDFC

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

VAV TERMINAL BOXES TYPE: BA BT

HIGH STATIC FAN COIL UNITS

FS Fan-Coil Units Hi-Rise, Vertical

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

MODULAR AIR HANDLING UNITS GAH SERIES

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

Address: VTS Clima L.L.C.

FAN POWERED TERMINAL UNITS

Features: Available in horizontal and vertical units

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Medium Pressure Centrifugal Fans

SECTION AIR TERMINAL UNITS

Swegon PACIFIC. Integrated climate beam

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

Sentinel D-Box Single Fan

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

High Performance Fan Coils FCHG Genesis Series Horizontal

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Landmark Rooftop Packaged Units

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

University of Delaware

DC INVERTER DUCTED AIR CONDITIONERS

KLIMA Active Chilled Beams

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

Transcription:

EC Motor MultiZone Fan Coil Units IXDL-Y Series 00 000 l/s

Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout the Western Pacific Rim. Corporate Head Office is located in New Zealand with factories in Auckland and Sydney. A network of offices, warehouses and distributors provide local support and representation in Australasia, South East Asia and China. temperzone s aim is to provide the most competitively priced, reliable and efficient air conditioning equipment available to the international market. A privately owned company, temperzone Holdings Ltd, is the parent company of temperzone ltd (est.956) in Auckland and temperzone Australia pty ltd in Sydney. The wide range of temperzone products are manufactured in Auckland for markets in Australasia and Asia. This range includes air distribution items and fans for New Zealand. The Sydney headquarters acts as both a distribution centre and manufacturer of customised and larger standard air conditioning units specifically for Australia. temperzone s Asia Regional Head Office is located in Singapore. The combined group operations employ over 500 staff. Temperzone s Fan Coil History Temperzone have been manufacturing chilled water fan coil units for more than 5 years. The original RCMC units were superseded in the mid 980 s with a new breed of RCMC which were then superseded in the late 990 s with the IMDL range. Prior to the development of temperzone s EC motor fan coils, units had all been manufactured with fixed single speed or multi-speed PSC motors. Any changes in the cooling or heating performance had been solely on the basis of varying the water flow by way of a 2-way or -way water regulating/ modulating valve. With the indoor fan running on a constant speed, this left considerable room for improvement in designing higher efficiency models. The new IXDL-Y version with EC (Electronically Commutated) motors is a step forward. EC motors allow for the air flow to be controlled over a wider range via the use of a 0 0V dc variable signal. Speeds as high as 2500 rpm and as low as 500 rpm are available by the variable voltage signal. With sophisticated controls the multipe single fan / single fan motors allow for the individual control of each outlet and fan for zone control. Other sophisticated controls and water control valves can be fitted as an optional extra (over a drain tray extension). 2

IXDL-Y Fan Coil Units GENERAL Fan coil units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. temperzone offers an extensive range of ducted fan coil units. A variety of options and accessories are available to meet most air conditioning requirements. Low operating cost, energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of temperzone IXDL Series fan coil units. All IXDL fan coil units can be handed left or right. Unless otherwise ordered units will be supplied right handed which is the standard handing, i.e. when facing the discharge side of the unit, the water and electrical connections are on the right hand side. TYPICAL APPLICATIONS Office Buildings The low overall height of 260 mm makes them ideally suited to office building applications where false ceiling space is at a premium. Hotels IXDL units are extremely well suited for individual room control. Airport Terminal Buildings temperzone fan coil units are gaining worldwide popularity in airport terminals. These complexes generally consist of a number of areas with very diverse occupancy and capacity requirements. Hospitals The majority of hospital rooms must have a separate and independent air conditioning system. This is to avoid bacterial cross contamination. temperzone fan coil units have been used successfully in these applications. STANDARD FEATURES Drain Tray The drain tray is removable for ease of cleaning and can be adjusted to slope when the unit is installed level. Motors High efficiency electronically commutated (EC) motors are fitted as standard on all units. Motors can be operated on 0-00% capacity using a 0-0V dc signal supplied by a BMS or sophisticated controller. The motors are resiliently mounted, self aligning and oiled for life. Fans Quiet low line, centrifugal type, double width, statically and dynamically balanced, multibladed impellers are used. The position and shape of the fan blades and housing has been developed after extensive testing to achieve minimum noise levels while maintaining a smooth pressure vs air flow curve. Coils Coils are manufactured in rifled copper tubing. All coils are thoroughly tested to 200 kpa. Coil rows are staggered for maximum heat exchange. Four different coil configurations are available refer table below. The coil fins are manufactured as a continuous plate, die formed from epoxy coated aluminium with a smooth corrugated surface, specially designed to overcome and prevent lint build up. The coil fins are mechanically bonded to the copper tubing which results in a rigid assembly and provides a permanent metallic contact between fins and tube for maximum heat transfer. Casing The casing is manufactured from high quality galvanised steel and internally insulated. Insulation Closed cell foam insulation has been used in the cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets the fire test standards AS 50. (989) and BS 76 parts 6 and 7. Noise attenuation material is fitted with the individual supply air plenum chambers of each fan. ELECTRICAL BOX Wiring from the motors terminate in a terminal block in a sheetmetal enclosed electrical box. The box is supplied on the same side as the water connections, but can be changed on site to the opposite side. WIRING The electrical supply required (including voltage fluctuation limits) is: phase 200-252 V a.c. 50 Hz with neutral and earth. Each IXDL unit is fully wired ready to accept the main power supply. ORDER DETAIL Coil Options: - Three row coil for cooling - Four row coil for cooling / - Three row cooling / one row heating / - Four row cooling / one row heating IXDL * Y- Examples: IXDL 60Y-/ IXDL 0Y- Series Size Coil Option

TECHNOLOGY VAV For the last 0 years virtually all fan coil units have operated with a constant fan speed and therefore constant air volume (CAV). Temperature changes in these units were achieved by the water valve, i.e. varying the water volume. With this design, energy was wasted due to fans constantly running at full speed, regardless of the requirement of the thermal zone served. With temperzone s new range of VAV fan coil units, varying air volume results in greater efficiency. Controls The new EC motor version IXDL units allow for several methods of control allowing great flexibility to meet the demands of modern buildings expectations. The fan speed could be adjusted for instance as the first step of capacity control before adjusting water flow. Potentiometer The fans could be controlled by the fitting of a potentiometer to preset the required speed. This will be particularly useful during onsite commissioning to adjust to obtain the desired air flow. BMS Many modern buildings these days have Building Management Sytems (BMS) and it is most desirable to control the fan speed variably to meet the building s load demands. The unit can accept a 0-0Vdc signal from the BMS or other sophisticated controller. The BMS can be programmed to achieve various beneficial functions such as; maintaining high air flow when on heating first thing in the morning to avoid stratification within the space, reducing the air flow down to say 50 to 60% as a capacity control method prior to adjustment of the water flow. EC Motors Brushless EC motors within the fan coil units provide a cooler running motor emitting less heat into the supply air. This is achieved as energy savings reduce the fan power to almost a quarter of a comparable PSC motor. The life expectancy of an EC motor can be up to twice as long as a comparable PSC motor due to functions such as the soft start which eliminate stress to the mounting bracket or hardware. This improved life expectancy further benefits the building owner by a reduction in maintenance costs. Key Features Energy Efficient EC Motor Significant Energy Savings On-site Adjustable Fan Air Volume Controller Remote Fan Air Volume Adjustment Capability from BMS.

Specification Model IXDL 0Y IXDL 90Y IXDL 0Y IXDL 60Y IXDL 200Y Nominal Air Flow @ 50 Pa external static (l/s) * 200 00 600 800 000 Air Flow Range (l/s) 0-225 0-50 0-675 0-900 0-25 No. of Outlet Spigots 2 5 Control Fan Type 0-0Vdc (High/Med/Low optional with conversion boards added) Forward curved centrifugal double inlet double width No. of Fans 2 5 Motor Type Power Source** Electronically Commutated (EC) DC direct drive Phase 20Volt AC 50 Hz No. of Motors 2 5 Motor Rating (W) 82 82 (x2) 82 (x) 82 (x) 82 (x5) Full Load Amps (A).. x 2 (2.8). x (.2). x (5.6). x 5 (7.0) Amps at Nominal Air Flow (A) 0. 0. x 2 (0.8) 0. x (.2) 0. x (.6) 0. x 5 (2.0) Heat Exchanger Type Cooling/Heating Medium Options Finish Test Epoxy coated aluminium corrugated plate fins to expanded rifled copper tubing Chilled water or hot water or row cooling or or row cooling + row heating Natural zinc galvanised steel 200 kpa Connection Sizes Cooling Coil 25 BSP Male ( ) Connection Sizes Heating Coil BSP Male (/2 ) Air Filter Type washable G2 / EU2 No. of Filters 2 2 2 2 Air Filter Size (mm) 66 x 6 x 8 x 6 x 68 x 6 x 858 x 6 x 058 x 6 x Static to allow for Air Filter (Clean) Static to allow for wet surface coil Outlet Spigot Options (mm) Weight (with water) (kg) 5 7 92 2 Nett Weight (without water) (kg) 2 9 68 8 0 Shipping Weight (kg) 5 72 90 0 Notes: - * With no filters fitted, a dry coil surface, and approx. 7 voltdc control voltage. ** Voltage fluctuation limits 200-252 V 5 Pa 25 Pa 250Ø Summary of Choices Size 0 / 90 / 0 / 60 / 200 Cooling and Heating Coil Configurations Multi S/A Spigot Handing Rows Cooling Rows Cooling + Row Heating Rows Cooling Rows Cooling + Row Heating 250Ø Standard Right (Standard) / Left 5

IXDL 0Y Cooling Capacity kw Entering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 200 l/s Entering Temperature C 0.9.2. 2.5. 2. 2.9 2. 2.6 2.2 2. 2. 0.5 9.2. 2.7.8 2.6.5 2.5.2 2. 2.9 2. 0.60 2.2.6 2.9.2 2.8.9 2.7.6 2.6.2 2.5 0.26.5. 2.9.9 2.8.6 2.7. 2.6.0 2.5 0. 8.5.8...0. 2.9.7 2.8. 2.7 0.59.0 5.2..8.2..0.0 2.9.6 2.8 Entering Air Temperature 2.0 C db 7.0 C wb Medium Air Flow 50 l/s Entering Temperature C 0.9.2 2.8.9 2.6.9 2..8 2.2.7 2.0.6 0.5 9.2. 2..2 2.0 2.9 2.0 2.7.9 2..8 0.60 2.2.9 2..6 2.2. 2..0 2.0 2.7.9 0.26.5.5 2.5.2 2..0 2. 2.7 2. 2.5 2.2 0. 8.5.9 2.7.6 2.6. 2.5. 2. 2.8 2. 0.59.0.2 2.8.9 2.7.6 2.6. 2.5.0 2. Entering Air Temperature 2.0 C db 7.0 C wb Low Air Flow 00 l/s Entering Temperature C 0.9.2 2..6 2.2.5 2..5.9..7. 0.5 9.2 2.9.7 2.7.7 2.5.6 2..5 2..5 0.60 2.2..8.0.8 2.8.7 2.6.6 2..6 0.26.5 2.9.8 2.7.8 2.5.7 2..6 2.0.6 0. 8.5..9.0.9 2.8.8 2.6.7 2..7 0.59.0.5 2.0. 2.0.0.9 2.8.8 2.5.7 Heating Capacity Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Nominal Air Flow 200 l/s 0.06 2.0..8 2.2 2.6.0..7..5 0. 7.7.7 2.2 2.6..5.0..9 5. 0.2 22.0.8 2. 2.9..9..9 5. 5.8 Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Medium Air Flow 50 l/s 0.06 2.0.2.6.9 2. 2.6 2.9.2.6.9 0. 7.7..9 2. 2.6.0..8.2.6 0.2 22.0.6 2. 2.5 2.9..7.2.6 5.0 Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 0.06 2.0.0..6.9 2. 2. 2.7.0. 0. 7.7.2.6.9 2.2 2.5 2.8.2.5.8 0.2 22.0..7 2. 2. 2.8..5.9.2 Low Air Flow 00 l/s 6

IXDL 0Y Air Handling (Single fan operating) l/s - Pa l/s - W 8V 0V 75 50 25 Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. 5V V V 2V 6V 7V 00 75 50 25 0 Air flows given are for IXDL-Y units without filter installed. Refer page 22 for filter pressure drop. 200 0.7A 0.6A 0.87A.A 80 60 0.9A 0 20 0.25A 0.7A 00 0.5A 0.50A 0V 80 8V 0.08A 0.A 7V 60 0.9A 6V 0 0.09A 5V 20 0.0A V.A V 2V 0.07A 0.A 0.26A 0.A 0.62A 0.87A.0A 0 0 25 50 75 00 25 50 75 200 225 250 Nominal 2.5 m/s Face Velocity Test Conditions: BS 88 PT2 985 Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 62 67 66 60 52 5 6 8 6 67 66 60 5 5 6 7* 60 65 6 58 50 8 6 58 6 6 56 8 6 5 55 6 59 5 6 2 8 52 58 57 9 2 7 2 7 55 52 5 8 2 26 2 5 9 0 25 20 Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 6 68 6 58 56 57 5 8 6 68 6 58 56 57 56 7* 6 66 62 56 5 5 5 6 59 6 6 5 5 52 9 5 57 6 58 50 50 8 5 52 58 5 6 6 9 7 55 50 2 7 2.55 52 8 5 25 *Nominal 7

IXDL 90Y Cooling Capacity kw Entering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 00 l/s Entering Temperature C 0.25 7.5 6.6 5.0 6..8 5.7.6 5...7.2 0. 8.8 8. 5. 7.5 5.2 6.9 5.0 6..8 5.7.6 0.62 8. 9.0 5.8 8. 5.6 7.7 5. 7.0 5. 6..9 0.7 9.2 8.6 5.9 8.0 5.7 7. 5.5 6.7 5.2 6. 5.0 0.55 8.9 9.7 6. 9.0 6.0 8. 5.8 7.6 5.6 6.8 5. 0.77 5.0 0.5 6.5 9.7 6. 9.0 6. 8.2 5.8 7. 5.6 Entering Air Temperature 2.0 C db 7.0 C wb Medium Air Flow 00 l/s Entering Temperature C 0.25 7.5 5.6.9 5..7.8.6...9. 0. 8.8 6.8.2 6.. 5.8.9 5..7.8.6 0.62 8. 7.6.5 7.0. 6.5.2 5.9.0 5..8 0.7 9.2 7. 5. 6.5.9 6..7 5.5.5 5.0. 0.55 8.9 8.0 5. 7. 5.2 6.8 5.0 6.2.8 5.6.6 0.77 5.0 8.6 5.6 7.9 5. 7. 5.2 6.7 5.0 6.0.8 Entering Air Temperature 2.0 C db 7.0 C wb Low Air Flow 220 l/s Entering Temperature C 0.25 7.5.8.2... 2.9.7 2.8. 2.7 0. 8.8 5.8.5 5.. 5.0.2.5.. 2.9 0.62 8. 6.5.7 6.0.6 5.6. 5...6.2 0.7 9.2 5.9.7 5.5.5 5...6.2.. 0.55 8.9 6.7.9 6..7 5.7.6 5.2.5.7. 0.77 5.0 7.2. 6.6.9 6..8 5.6.6 5.0.5 Heating Capacity Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Nominal Air Flow 00 l/s 0. 0... 5.2 6. 6.9 7.8 8.7 9.6 0.5 0. 8.8.9 5.0 6. 7. 8. 9.2 0.2. 2. 0.8 29.. 5.5 6.7 7.8 8.9 0..2 2..5 Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Medium Air Flow 00 l/s 0. 0. 2.8.7. 5.2 5.9 6.7 7.5 8.2 9.0 0. 8.8.. 5.2 6. 7.0 7.9 8.8 9.7 0.6 0.8 29..7.8 5.7 6.7 7.7 8.7 9.7 0.7.6 Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 0. 0. 2...7. 5.0 5.6 6.2 6.9 7.5 0. 8.8 2.8.6. 5. 5.8 6.6 7. 8. 8.9 0.8 29...0.8 5.6 6. 7.2 8. 8.9 9.7 Low Air Flow 200 l/s 8

IXDL 90Y Air Handling (Both fans operational) l/s - Pa l/s - W 8V 0V 50 00 250 Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. 200 5V V 2V V 6V 7V 0.7A.28A.7A 2.27A 200 50 00 50 0 Air flows given are for IXDL-Y units without filter installed. Refer page 22 for filter pressure drop. For individual fan performance see page 7 - IXDL 0Y Fan Curve 80 60.8A 0 20 0.50A.A 00 0.0A 0.99A 0V 80 8V 0.6A 0.66A 7V 60 0.8A 6V 0 0.9A 5V 20 0.0A 0.09A V 2.28A V 2V 0.A 0.28A 0.5A 0.8A.2A.76A 2.20A 0 0 50 00 50 200 250 00 50 00 50 500 Nominal 2.5 m/s Face Velocity Test Conditions: BS 88 PT2 985 Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 65 70 69 6 55 5 9 8 6 70 69 6 5 5 9 7* 6 68 67 6 5 5 7 6 60 66 65 58 50 8 5 57 6 6 55 8 0 5 60 59 5 9 8 56 5 6 9 27 2 2 52 5 0 26 2 Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 66 7 67 6 59 60 56 8 66 7 67 6 59 60 56 7* 6 69 65 59 57 57 5 6 6 66 6 56 55 5 5 5 58 6 60 52 52 50 7 5 60 56 8 8 5 8 56 5 8 2.55 2 5 9 6 2 26 *Nominal 9

IXDL 0Y Cooling Capacity kw Entering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 600 l/s Entering Temperature C 0.2 9.0 8.0 6.6 7. 6. 6.8 6. 6.2 5.8 5.6 5.5 0.6 8.5 9.7 7. 9.0 6.9 8. 6.6 7.6 6. 6.8 6. 0.5.8 0.9 7.6 0.0 7. 9. 7. 8.5 6.8 7.6 6.5 0.5 0.5 0.6 7.9 9.8 7.6 9. 7. 8. 7.0 7. 6.7 0.9 9..9 8..0 8. 0.2 7.8 9. 7.5 8. 7.2 0.6 0.2 2.9 8.8.9 8.5.0 8.2 0.0 7.8 9.0 7.5 Entering Air Temperature 2.0 C db 7.0 C wb Medium Air Flow 50 l/s Entering Temperature C 0.2 9.0 6.7 5. 6.2.9 5.7.7 5.2.5.7. 0.6 8.5 8.2 5.6 7.5 5. 7.0 5. 6..9 5.7.7 0.5.8 9. 5.9 8. 5.7 7.8 5.5 7. 5. 6. 5. 0.5 0.5 8.7 6.8 8.0 6.6 7. 6. 6.8 6. 6. 5.8 0.9 9. 9.8 7.2 9.0 7.0 8. 6.7 7.6 6. 6.9 6.2 0.6 0.2 0.6 7.6 9.8 7. 9.0 7.0 8.2 6.7 7. 6. Entering Air Temperature 2.0 C db 7.0 C wb Low Air Flow 00 l/s Entering Temperature C 0.2 9.0 5.7.2 5..0.9.9.5.7..5 0.6 8.5 7.0.6 6.5. 6.0.2 5...9.9 0.5.8 7.8.9 7.2.7 6.7.5 6.. 5.5.2 0.5 0.5 7..9 6.7.7 6.2.5 5.7. 5..2 0.9 9. 8.2 5.2 7.5 5.0 7.0.8 6..6 5.7. 0.6 0.2 8.8 5.5 8. 5. 7.5 5. 6.9.9 6.2.6 Heating Capacity Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Nominal Air Flow 600 l/s 0.08 9.0.0 5.2 6. 7. 8. 9.5 0.6.7 2.8 0.2 8..8 6. 7. 8.7 9.9.2 2.5.8 5.0 0.6 0.8 5.2 6.8 8.2 9.6 0.9 2..7 5. 6. Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Medium Air Flow 50 l/s 0.08 9.0.5.5 5. 6. 7.2 8.2 9. 0..0 0.2 8.. 5. 6. 7.5 8.5 9.6 0.7.8 2.9 0.6 0.8.5 5.8 7.0 8.2 9. 0.6.8.0. Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 0.08 9.0 2.9.8.5 5. 6. 6.8 7.6 8. 9.2 0.2 8... 5. 6. 7. 8. 9.0 9.9 0.8 0.6 0.8.8.9 5.9 6.9 7.8 8.9 9.9 0.9.8 Low Air Flow 00 l/s 0

IXDL 0Y Air Handling (All three fans operational) l/s - Pa l/s - W 8V 0V 525 50 75 Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. 200 5V V 2V V 6V 7V.A.92A 2.6A.0A 00 225 50 75 0 Air flows given are for IXDL-Y units without filter installed. Refer page 22 for filter pressure drop. For individual fan performance see page 7 - IXDL 0Y Fan Curve 80 60 2.72A 0 20 0.75A 2.2A 00 0.5A.9A 0V 80 8V 0.2A 0.98A 7V 60 0.57A 6V 0 0.28A 5V 20 0.0A 0.A V.2A V 2V 0.20A 0.A 0.79A.22A.85A 2.60A.0A 0 0 75 50 225 00 75 50 525 600 675 750 Nominal 2.5 m/s Face Velocity Test Conditions: BS 88 PT2 985 Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 68 7 7 67 58 57 52 8 68 7 7 66 57 56 5 7* 66 7 7 6 56 5 8 6 6 69 68 6 5 50 5 60 65 65 57 50 7 0 56 62 6 5 6 0 5 9 56 5 7 0 2 26 2 2 9 7 29 22 Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 69 76 72 6 6 62 58 8 68 76 70 6 60 6 57 7* 66 7 69 6 59 59 5 6 6 7 66 59 57 56 5 5 60 68 6 55 5 5 7 56 6 60 5 9 6 50 59 5 6 9 2.55 2 5 6 0 5 2 *Nominal

IXDL 60Y Cooling Capacity kw Entering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 800 l/s Entering Temperature C 0.2 0.0 0. 8. 9. 8. 8.6 7.8 7.8 7.5 7. 7. 0. 9.0 2. 9.2. 8.8 0.5 8.5 9.6 8.2 8.6 7.8 0. 2.0.8 9.8 2.7 9.5.8 9. 0.7 8.7 9.6 8. 0..8.7 0. 2.7 0.0.7 9.6 0.7 9.2 9.6 8.8 0. 8.9 5..0. 0.6.2 0.2 2.0 9.8 0.8 9. 0.5 27.5 6.7.5 5... 0.7.0 0.2.7 9.8 Entering Air Temperature 2.0 C db 7.0 C wb Medium Air Flow 600 l/s Entering Temperature C 0.2 0.0 8.5 6.6 7.8 6. 7.2 6. 6.6 5.9 6.0 5.6 0. 9.0 0. 7.2 9.5 6.9 8.8 6.6 8.0 6. 7.2 6. 0. 2.0.6 7.7 0.7 7. 9.9 7. 9.0 6.8 8. 6.5 0..8. 8.9 0. 8.6 9.6 8.2 8.8 7.9 7.9 7.6 0. 8.9 2.7 9.5.7 9. 0.8 8.8 9.8 8. 8.9 8. 0.5 27.5.7 9.9 2.6 9.5.7 9.2 0.6 8.8 9.6 8. Entering Air Temperature 2.0 C db 7.0 C wb Low Air Flow 00 l/s Entering Temperature C 0.2 0.0 7. 5. 6.7 5.2 6.2 5.0 5.6.8 5..6 0. 9.0 8.8 5.9 8.2 5.7 7.6 5. 6.9 5.2 6.2 5.0 0. 2.0 9.9 6. 9. 6. 8.5 5.8 7.7 5.6 6.9 5. 0..8 9. 6. 8.7 6.2 8.0 5.9 7. 5.7 6.6 5.5 0. 8.9 0.6 6.8 9.8 6.6 9.0 6. 8.2 6. 7. 5.8 0.5 27.5. 7. 0.5 6.9 9.8 6.6 8.9 6. 8.0 6. Heating Capacity Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Nominal Air Flow 800 l/s 0.09 9.0. 5.7 6.9 8. 9.2 0..6 2.8.0 0. 8.2 5.2 6.7 8. 9.5 0.8 2.2.6 5.0 6. 0.7 29.5 5.7 7. 8.9 0.5.9. 5.0 6.5 7.9 Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Medium Air Flow 600 l/s 0.09 9.0.8.9 5.9 6.9 7.9 8.9 9.9.0 2.0 0. 8.2.5 5.8 7.0 8.2 9. 0.5.7 2.9. 0.7 29.5.9 6. 7.7 9.0 0.2.5 2.9.2 5. Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 0.09 9.0.2. 5.0 5.8 6.6 7.5 8. 9.2 0.0 0. 8.2.7.8 5.8 6.8 7.8 8.8 9.8 0.8.8 0.7 29.5. 5. 6. 7.5 8.6 9.7 0.8.9 2.9 Low Air Flow 00 l/s 2

IXDL 60Y Air Handling (All four fans operational) l/s - Pa l/s - W 8V 0V 700 600 500 Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. 200 5V V 2V V 6V 7V.8A 2.56A.8A.5A 00 00 200 00 0 Air flows given are for IXDL-Y units without filter installed. Refer page 22 for filter pressure drop. For individual fan performance see page 7 - IXDL 0Y Fan Curve 80 60.62A 0 20.00A 2.82A 00 0.60A.98A 0V 80 8V 0.2A.A 7V 60 0.76A 6V 0 0.7A 5V 20 0.0A 0.7A V.56A V 2V 0.26A 0.55A.05A.62A 2.6A.6A.0A 0 0 00 200 00 00 500 600 700 800 900 000 Nominal 2.5 m/s Face Velocity Test Conditions: BS 88 PT2 985 Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 70 75 76 68 60 57 5 8 69 7 7 67 59 56 52 7* 67 72 72 65 57 5 8 6 6 70 70 62 5 50 5 5 6 66 66 59 5 6 0 56 62 62 55 7 5 5 57 56 9 29 2 5 8 26 Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 70 78 7 66 6 6 59 8 70 77 7 65 6 62 58 7* 68 75 7 6 59 59 55 6 65 7 70 60 57 56 52 5 6 70 66 56 5 52 7 57 66 62 5 50 7 5 6 55 6 9 2.55 5 7 0 5 2 *Nominal

IXDL 200Y Cooling Capacity kw Entering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 000 l/s Entering Temperature C 0.22 0.. 9.9 0. 9.6 9.5 9.2 8.7 8.8 7.9 8. 0. 8.8.6 0.8 2.5 0..6 0.0 0.6 9.6 9.5 9.2 0.9 0.0 5.2.6.0..0 0.7.8 0. 0.7 9.8 0.2 2.5 5. 2.2..7...9 0.8 0.7 0. 0. 8.6 7.2.0 5.9 2.5.7 2.0..5 2..0 0.8 26.0 8.6.5 7..0 5.9 2.5. 2.0.0.5 Entering Air Temperature 2.0 C db 7.0 C wb Medium Air Flow 750 l/s Entering Temperature C 0.22 0. 9. 7.8 8.6 7.5 8.0 7.2 7. 6.9 6.6 6.5 0. 8.8. 8. 0.5 8. 9.7 7.8 8.9 7.5 8.0 7.2 0.9 0.0 2.8 9.0.8 8.7 0.9 8. 9.9 8.0 8.9 7.7 0.2 2.5 2.6 0.5.6 0. 0.7 9.7 9.8 9. 8.8 8.9 0. 8.6...0 0.7 2. 0..0 9.9 9.9 9.5 0.8 26.0 5.2.6..2.0 0.8.8 0. 0.7 9.9 Entering Air Temperature 2.0 C db 7.0 C wb Low Air Flow 500 l/s Entering Temperature C 0.22 0. 8.0 6. 7. 6. 6.8 5.9 6.2 5.7 5.7 5. 0. 8.8 9.8 6.9 9.0 6.7 8. 6. 7.6 6. 6.8 5.9 0.9 0.0 0.9 7. 0. 7. 9. 6.8 8.5 6.6 7.7 6. 0.2 2.5 0.5 7.6 9.7 7. 9.0 7.0 8.2 6.7 7. 6. 0. 8.6.8 8.0 0.9 7.7 0. 7. 9.2 7. 8. 6.8 0.8 26.0 2.7 8..7 8. 0.9 7.8 9.9 7.5 8.9 7.2 Heating Capacity Entering Air Temperature 2.0 C db Entering Temperature C Nominal Air Flow 000 l/s 0 5 50 55 60 65 70 75 80 0.09.5.9 6. 7.7 9. 0..6.0. 5.6 0.2 8.9 5.8 7.5 9. 0.6 2..7 5.2 6.8 8. 0.5 27.9 6. 8. 0.0.7. 5.0 6.8 8.5 20. Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 Medium Air Flow 750 l/s 0.09.5.2 5.5 6.6 7.8 8.8 0.0. 2.. 0.2 8.9 5.0 6.5 7.8 9.2 0..8..5 5.8 0.5 27.9 5.5 7. 8.6 0.. 2.9. 5.9 7. Entering Air Temperature 2.0 C db Entering Temperature C 0 5 50 55 60 65 70 75 80 0.09.5.6.6 5.6 6.5 7. 8. 9. 0.. 0.2 8.9.2 5. 6.5 7.7 8.7 9.8.0 2..2 0.5 27.9.6 5.9 7.2 8. 9.6 0.8 2...5 Low Air Flow 500 l/s

IXDL 200Y Air Handling (All five fans operational) l/s - Pa l/s - W 8V 0V 875 750 625 Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. 200 5V V 2V V 6V 7V.85A.2A.5A 5.66A 500 75 250 25 0 Air flows given are for IXDL-Y units without filter installed. Refer page 22 for filter pressure drop. For individual fan performance see page 7 - IXDL 0Y Fan Curve 80 60.5A 0 20.25A.5A 00 0.75A 2.8A 0V 80 8V 0.0A.6A 7V 60 0.95A 6V 0 0.6A 5V 20 0.2A V 5.70A V 2V 0.A 0.69A.A 2.0A.08A.A 5.50A 0 0 25 250 75 500 625 750 875 000 25 250 Nominal 2.5 m/s Face Velocity Test Conditions: BS 88 PT2 985 Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 7 76 77 69 6 58 5 8 70 75 75 68 60 57 5 7* 68 7 7 66 58 5 9 6 65 7 7 6 55 5 6 5 62 67 67 60 52 7 57 6 6 56 8 2 6 52 58 57 50 2 5 0 2 5 52 9 2 5 2 27 Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power 25 250 500 K SWL db(a) Sound Power Levels (SWL) db 2K K 9 7 79 75 67 62 6 60 8 7 78 7 66 62 6 59 7* 69 76 72 6 60 60 56 6 66 7 7 6 58 57 5 5 62 7 67 57 5 5 8 58 67 6 5 5 8 2 52 62 56 7 0 2.55 5 55 8 6 2 25 *Nominal 5

DIMENSIONS (mm) - IXDL 90Y model shown (not to scale) FILTER ACCESS EITHER END, OR LIFT OUT D MOUNTING CENTRES B (HEIGHT = 75) WATER CONN'S 80 268 280 MTG CTR HEAT COOL DRAIN 9 OD 500 MIN. CLEARANCE 00 OVERALL 00 ALTERNATIVE POSITION VIA 90ϒ ROTATION & FLIP ON-SITE C OVAL SPIGOTS TO SUIT FLEXIBLE DUCTING ELECTRICAL BOX 252 OVERALL OUT IN A OVERALL Note:. Allow adequate clearance for the filter (if fitted) to be removed. 2. IXDL have two half length filters except for IXDL 0Y. Model A B C D S/A Spigots Conn s BSP Male IXDL 0Y 706 7 2 529 250 dia (x) 25 IXDL 90Y 250 97 820 00 250 dia (x2) 25 2 IXDL 0Y 605 7 252 0 250 dia (x) 25 IXDL 60Y 95 722 60 780 250 dia (x) 25 IXDL 200Y 255 222 207 278 250 dia (x5) 25 5 Cold Hot No. Fans / Outles / Zones 6

WIRING DIAGRAM: IXDL 0Y 7

8 WIRING DIAGRAM: IXDL 90Y

WIRING DIAGRAM: IXDL 0Y 9

20 WIRING DIAGRAM: IXDL 60Y

WIRING DIAGRAM: IXDL 200Y 2

Filter Drop G2 / EU2 rated filter media (standard) PRESSURE DROP (Pa) 70 60 50 0 0 20 0 FINAL PRESSURE DROP 25 Pa INITIAL (Clean Filter) EU2 (G2) 0 0 0.5.0.5 2.0 2.5.0.5 FILTER FACE VELOCITY (m/s) Note: G2 / EU2 filters do not meet Australian standards so are not to be used in the Australian market. G / EU filters, that meet the Australian standard, are best located behind return air grilles or in the ducting to reduce the velocity and therefore resistance losses. Filter Area : IXDL 0Y 0.075 m 2 IXDL 90Y 0.5 m 2 IXDL 0Y 0.22 m 2 IXDL 60Y 0.275 m 2 IXDL 200Y 0. m 2 Suggested Specification Furnish and install temperzone fan coil units as indicated on the schedule. Base Unit The base unit shall be fabricated of galvanised steel. Motor Motors shall be electronically commutated (EC) type with 0-00% variable capacity using a 0-0V dc signal supplied by BMS or sophisticated controller.* Coils Coils shall be comprised of die formed plate type epoxy coated aluminium fins mechanically bonded to high efficiency seamless inner rifled copper tubing. connections shall be male threaded. Cooling coils shall have a manual air vent. Drain Tray The plastic drain tray shall have an adjustment for inducing a positive drainage with the unit level. The tray shall project under the entire length and width of the coil including headers and return bends. The entire drain tray shall be removable to enable a thorough clean. Filters Filters shall be removable, mm thick, washable, rated EU2, and mounted in a plastic frame. Filters may be slid out sideways when a return air duct is used. Insultation The base unit shall be insulated with closed cell foam to ensure no particles are introduced into the air steam. Insulation shall be foil faced and meet fire test standards AS 50. (989) and BS 76 parts 6 & 7. Insulated with acoustic atenuation material on the discharge side of the fan. Noise Control Supply air plenums shall be insulated with open cell acoustic material for noise attenuation. * The fan/motor may also be set to a single predetermined speed using a potentiometer. 22

Notes 2

Note: The manufacturer reserves the right to change specifications at any time without notice or obligation. Available from manufactured and distributed by: temperzone limited Head Office, Auckland : 8 Tidal Rd, Mangere, N.Z. Private Bag 90, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.co.nz temperzone australia pty ltd Head Office, Sydney : Carnagie Pl. PO Box 68, Delivery Centre, Blacktown, NSW 28, AUSTRALIA. Email sales@temperzone.com.au Website: www.temperzone.com.au 08/7 Pamphlet No. 969 temperzone limited 207