Softstarters. Softstarters Power electronic brakes Type PEB

Similar documents
Power electronic brakes

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

APPENDIX A: TECHNICAL SPECIFICATIONS WARRANTY INFORMATION...

smissline Description

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Technical data OT16E3 OT160E3 UL & CSA

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

MOTORTRONICS Solid State AC Motor Control

System pro M compact Modular DIN rail components E220 - E270 Series

Individual & fixed bank capacitors

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

WARRANTY INFORMATION...

System pro M compact Miniature Circuit Br eakers Description Features

DNH INDUSTRIES ***** COMPACT ***** EASY TO INSTALL ***** STATUS INDICATORS ***** DUAL LINE FUSING ***** INSULATED FRONT COVER ***** ADJUSTABLE OUTPUT

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

MaxPak Plus Analog DC V S Drive

SECTION MOTOR CONTROL

EPS-ECONOMY PUMP STARTER

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

MAGNETIC MOTOR STARTERS

TDX - Taco Duplex Starter with

Designed for ease of integration with automation systems

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

FJ303-3PB6B. 4X Plastic 12. Catalog List Catalog List number price number price

CONTROL FEATURES AVAILABLE OPTIONS

Sensors. Proximity Photoelectric Ultrasonic. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Sensors

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Application Description

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Softstarters Type PSR. Softstarters

Limit Switches Metal casing, 40mm & 60mm Assembled Components

Softstarters Type PSS. Softstarters. General information

CTi Automation - Phone: Fax: Web:

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Fincor Series 2230 MKII/2240

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds


Description 1/8-7.5HP

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

RVS-AX Instruction Manual

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

NEMA Contactors & Starters (Freedom)

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

MVC4MEDIUM VOLTAGESOLIDSTATESOFTSTARTER

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Dimensions WxHxD [mm] Weight [kg]

Submittal Data Information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

RVS-DN Digital Reduced Voltage Motor Starter

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Kits 30A 800A, 600V, 3 pole 1 UL fuse class J, CC, T, L

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

IEC Utilization Categories (Explanation)

LH4 Modular Soft Start

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Softstarters Softstarters

SD Series Non-Fused Load Switches

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

AF series contactors (9 2650)

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

EPS-ECONOMY PUMP STARTER

MODEL 422 Submersible Pump Controller

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

RVS-DX Digital Reduced Voltage Motor Starter

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Aldi V4 & V V1.1 5/23/2014

MOTOR TERMINAL CONNECTIONS

AIR COOLED RECTIFIER SPECIFICATION S-50-A

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Application Engineering

60 Series Engine Controls

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Table of Contents. Chapter 1: Introduction 1.1 General Description 1. Chapter 2 - Installation 2.1 Receiving and Unpacking.. 5

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

Product Description. Application Description

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Overload Relay Heater Tables

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

AF series contactors (9 2650)

team master medium voltage solid state starters

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Application Engineering

SECTION MOTOR CONTROLLERS

Transcription:

Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB) Series features full-wave DC braking which can be adjusted to stop your load quickly, repeatedly and reliably...even if load con ditions change. Unlike other brakes that only provide voltage control, the PEB Series is a current regulated brake. It automatically adjusts for resistance changes in the motor windings due to any input voltage fl uctuations. What does this mean? Repeatable, reliable operation every time you stop your motor. An exceptionally accurate method of microprocessor controlled sensing de termines when the motor shaft has come to a stop. Braking current is removed when the motor stops, elim inating excess braking current which means longer motor life. Built-in jogging circuitry allows you to select the time you need for machine setup and positioning without applying DC current to the motor windings. DC current is only applied when system setup is complete... no excess current, no excess heating, no premature motor failure. The PEB Series has a built-in feature to control a mechanical holding brake. Any fault indication automatically enables the mechanical brake for fail-safe operation. The PEB Series has been designed and tested to meet the most stringent industry standards: UL & cul. UL File # E19883 Low Voltage Products & Systems.55 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03 Spec Tech Industrial 203 Vest Ave. Valley Park, MO 3088 Phone: 888 SPECTECH Fax: 3 537-1405 www.spectechind.com

Softstarters General information Catalog number explanation PEB - 010-48 - 1 Maximum brake amps 010 10 024 24 050 50 100 100 200 200 300 300 400 400 550 550 800 800 1000 1000 Enclosure No digit Open chassis 1 NEMA 1 2 NEMA 12 3 NEMA 3R 4 NEMA 4 X NEMA 4X Voltage 24 208/240 48 480 0 00.5 Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com

Power electronic brakes Open Softstarters PEB-100-48 PEB-10-48 Max 208V 240V 480V 00V amps Horsepower Catalog Horsepower Catalog Horsepower Catalog Horsepower Catalog List 1 Std. duty Hvy. duty number Std. duty Hvy. duty number Std. duty Hvy. duty number Std. duty Hvy. duty number price 10 3 1 PEB-010-24 3 1 PEB-010-24 7.5 3 PEB-010-48 10 5 PEB-010-0 $ 755 24 7.5 3 PEB-024-24 10 5 PEB-024-24 20 10 PEB-024-48 25 15 PEB-024-0 1070 50 15 7.5 PEB-050-24 20 10 PEB-050-24 40 25 PEB-050-48 50 30 PEB-050-0 1450 100 30 20 PEB-100-24 40 15 PEB-100-24 75 50 PEB-100-48 100 0 PEB-100-0 2250 200 75 40 PEB-200-24 75 50 PEB-200-24 150 100 PEB-200-48 200 125 PEB-200-0 3900 300 100 0 PEB-300-24 125 75 PEB-300-24 250 150 PEB-300-48 300 200 PEB-300-0 4300 400 150 75 PEB-400-24 150 100 PEB-400-24 350 200 PEB-400-48 400 250 PEB-400-0 500 550 250 125 PEB-550-24 200 150 PEB-550-24 500 300 PEB-550-48 00 350 PEB-550-0 8700 800 350 200 PEB-800-24 350 200 PEB-800-24 700 450 PEB-800-48 900 500 PEB-800-0 10,250 1000 400 250 PEB-1000-24 400 300 PEB-1000-24 900 500 PEB-1000-48 1000 00 PEB-1000-0 13,000 NOTE: If duty cycle is not known, it is recommended to use the heavy duty brake since braking current can be adjusted down to meet actual load requirements. 1 Never exceed the motor FLA without checking the motor manufacturers data with regards to application duty cycle. Low Voltage Products & Systems Discount Schedule SSP.57 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03

Softstarters Power electronic brakes Enclosed, NEMA 1 Maximum motor HP ratings Maximum 208V 240V 480V 00V Amps Standard Heavy Standard Heavy Standard Heavy Standard Heavy FLA Duty Duty Duty Duty Duty Duty Duty Duty Options 1 Model number NEMA 12 NEMA 3R NEMA 4 NEMA 4X PEB-010 $ 100 $ 100 $ 150 $ 450 PEB-024 100 100 150 450 PEB-050 100 100 150 450 PEB-100 100 100 150 450 PEB-200 150 150 200 00 PEB-300 300 300 350 1050 PEB-400 300 300 350 1050 PEB-550 300 300 350 1050 PEB-800 300 300 350 1050 PEB-1000 300 300 350 1050 NEMA 1, 480V NEMA 1, 00V List Catalog number Catalog number price 10 3 1 3 1 7.5 3 10 5 PEB-010-48-1 PEB-010-0-1 $ 805 24 7.5 3 10 5 20 10 25 15 PEB-024-48-1 PEB-024-0-1 1120 50 15 7.5 20 10 40 25 50 30 PEB-050-48-1 PEB-050-0-1 150 100 30 20 40 15 75 50 100 0 PEB-100-48-1 PEB-100-0-1 2450 200 75 40 75 50 150 100 200 125 PEB-200-48-1 PEB-200-0-1 4320 300 100 0 125 75 250 150 300 200 PEB-300-48-1 PEB-300-0-1 4800 400 150 75 150 100 350 200 400 250 PEB-400-48-1 PEB-400-0-1 7000 550 250 125 200 150 500 300 00 350 PEB-550-48-1 PEB-550-0-1 9200 800 350 200 350 200 700 450 900 500 PEB-800-48-1 PEB-800-0-1 10,750 1000 400 250 400 300 900 500 1000 00 PEB-1000-48-1 PEB-1000-0-1 13,500 NOTE: See below for additional enclosure styles and price adders. 1 Add to list price of NEMA 1 enclosed products and change part number appropriately..58 Discount Schedule SSPE Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com

Technical data Softstarters Item Specifi cation Voltage rating Models rated from 208-00V ±10% Selectable for 50/0Hz ± 2 Hz Current ratings 10-1000A in 10 sizes: 10, 24, 50, 100, 200, 300, 400, 550, 800, 1000A Output capacity 25% duty cycle at 100% unit rating Power circuit Full wave bridge, 4 SCRs, designed for use without isolation contactors Transient protection RC snubber dv/dt circuit on each SCR device Fusing Approved for use with existing motor starter fusing when unit is sized for motor FLA. Consult NEC for any other fusing requirements. Control circuit Self-powered directly from line terminals. No separate control voltage required Control method Microprocessor unit controls sequencing, I/O monitoring and status annunciation. Braking current is adjustable via true RMS regulated control using phase angle fi ring of SCRs. Operator adjustments Brake Time and Jog Time = 7 position binary dipswitch Brake Current = potentiometer Adjustment ranges Brake Jog Times = 0-127 seconds in 1 sec. increments Brake Current = Up to 100% unit rating Inputs Starter Monitor = Dry input for auxiliary contact from motor starter. Jumper selectable for N.O. or N.C. contact. Brake Disable = Dry input for N.O. contact to disable braking before or during operation. Can be wired to the starter thermal overload N.O. auxiliary contact to prevent braking of overloaded motor. Motor Power Sensor (T3) = voltage input used for sensing motor power presence in sequencing/status circuit and for zero speed sensing during braking Outputs Starter Coil Interlock = Two sets of FORM C relay contacts for use in interlocking the starter coil and/or other devices to prevent energizing as the braking power is applied. Mechanical Brake Release = N.O. relay contact for use in controlling electro-mechanical brake as a holding brake. When the PEB Series is disabled, this circuit controls the mechanical brake normally as if it is the only brake in the system. Auxilliary contact ratings 5 amps, 250VAC max LED Status indicators Large LEDs: Braking = green; Fault = red Small LEDs: Power On, Jog/Armed, Brake Off, Disabled, Over Temp, and Wiring Error Operating design temperature 0-50 C (32-122 F) open 0-40 C (32-104 F ) enclosed Ambient conditions 0-95% relative humidity 0-3300ft (1000M) elevation Approvals UL, cul Listed Low Voltage Products & Systems.59 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03

Softstarters Approximate dimensions & Circuit diagram Open Approximate dimensions (inches) F B E C A D Model No. A B C D E F PEB-10 8.5 7.3.2 8.9 0.21 PEB-24 8.5 7.3.2 8.9 0.21 PEB-50 10.5 7.9 7.2 10.8 0.22 PEB-100 10.5 7.9 7.2 10.8 0.22 PEB-200 1.5 10 10 15.9 9 0.28 PEB-300 1 1 10 15 15 0.5 PEB-400 1 1 10 15 15 0.5 PEB-550 1 1 10 15 15 0.5 PEB-800 1 1 10 15 15 0.5 PEB-1000 1 1 10 15 15 0.5 Circuit diagram LINE POWER L1 L2 START/STOP CONTROL L1 STARTER INTERLOCK L1 L2 L3 COMMAND PEB POWER ELECTRONIC OPTIONAL DISABLE MECHANICAL 21 22 97 98 MECH RELAY A1 M A2 95 OL 9 L1 L2 L3 M OL MECHANICAL COIL MOTOR N.0 Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com

Approximate dimensions & Circuit diagram Enclosed Softstarters Approximate dimensions (inches) 1 B C E F A D Circuit diagram Model No. A B C D E F PEB-10 1 12 9 14.5 10.5 0.5 PEB-24 1 12 9 14.5 10.5 0.5 PEB-50 20 1 9 18.5 14.5 0.5 PEB-100 20 1 9 18.5 14.5 0.5 PEB-200 24 20 13 22.5 18.5 0.5 PEB-300 3 24 13 34.5 22.5 0.5 PEB-400 3 24 13 34.5 22.5 0.5 PEB-550 3 24 13 34.5 22.5 0.5 PEB-800 3 24 13 34.5 22.5 0.5 PEB-1000 3 24 13 34.5 22.5 0.5 LINE POWER L1 L2 START/STOP CONTROL L1 STARTER INTERLOCK L1 L2 L3 COMMAND PEB POWER ELECTRONIC OPTIONAL DISABLE MECHANICAL 21 22 97 98 MECH RELAY A1 M A2 95 OL 9 L1 L2 L3 M OL MECHANICAL COIL MOTOR N 1 Dimensions apply to NEMA 1, NEMA 12, NEMA 3R and NEMA 4 enclosures. Consult factory for NEMA 4X dimensions. Low Voltage Products & Systems.1 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03

Softstarters Notes.2 Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com