Installation manual ACO Mains operated drain doser (MODD) for Grease Traps

Similar documents
Domestic Water Supply Pressure Pumps

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

FlushMaster Cistern & Valve assembly

Owners Manual: - Pumps

c-go 24V/6A 24V/8A 24V/12A

24V Cordless 1/2in. Impact Wrench

Sectional and Tilting Door Opener

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Installation and Operation Instructions

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

BATTERY CHARGER-STARTER

Cordless Rechargeable Saw Instructions for Use

PRESSURE BOOSTER 150

Battery Charger JCB-FCH20LI2

OPERATION & MAINTENANCE INSTRUCTIONS

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

Sectional And Tilting Door Opener

VSP SERIES Installation, Operation and Maintenance Manual

Battery Charger JCB- SCH20LI.2

Sectional and Tilting Door Opener Installation Instructions and User Guide

BATTERY CHARGER BTC-1005A

OPERATION & MAINTENANCE INSTRUCTIONS

Model: SW02 Advanced OPERATING MANUAL

24 Volt - 3/8" Cordless Impact Wrench

Instructions for Use

Operating Instructions AC/Rechargeable Professional Hair Clipper

OPERATION & MAINTENANCE INSTRUCTIONS

2.0Ah BATTERY INSTRUCTION MANUAL

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

7 Handle Tubes. 10 Charging Jack 11 LED Indicator 12 ON/OFF button

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

AG-HA-2500N GASOLINE GENERATOR

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Battery Charger JCB-FCH12Li

PowerPlex 40V MAX Standard Battery Pack/Charger

Porte 150 Users Manual Swing Gate Opener 24V DC

DIGITAL BATTERY TESTER 12V

LEAD ACID BATTERY CHARGER

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Electronic Cordless Sweeper. Operating Instructions

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

V3700UK OWNER S GUIDE.

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

FREQUENCY INVERTER INSTALLATION & USER GUIDE

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Instructions for: FOLDING ENGINE CRANE PREMIER 2 TONNE. MODEL No: SPC2000

AirTMCordless HANDHELD

EASY CHARGE Weather-resistant fixed mount Battery Charger

BENCH GRINDER MODEL NO. OZBG150WA

EASY CHARGE Waterproof portable Battery Charger

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

Operating instructions in the back. PD1420LP

Instructions for use and installation Cooker Hood

Operating instructions in the back. PD1820LF

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

TC TC Operating instruction

Universal Battery Charger Cat. No.: Instruction Manual

Car Battery Charger Instructions for Use

Agxcel GX12i Chemical Injection System

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

C3 Operating Instructions

POSITIVE DISPLACEMENT FLOWMETER

18V CORDLESS DRILL MODEL NO: CON18LiC

2 Ton - 50 Ton Bottle Jack

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

STRUT SPRING COMPRESSOR

LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

Rolling Door Opener INSTALLATION INSTRUCTION AND OWNERS MANUAL

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

Description. ST-164 Dual injector. User Manual ST-164. Artikel-Nr.: XXX

80 Litre Suction Oil Drainer With Inspection Chamber

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

BOLT TENSIONERS. carefully before use and retain it for reference.

3.25 Ton Heavy Duty Floor Jack

TOOLPRO 18V Li-Ion Brushless Impact wrench

INSTALLATION & OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 (Coolers Only)

JABSCO & Series 1½ 80 SIZE UTILITY Pump

STRX-9 100% TAKE CONTROL INSTRUCTION MANUAL READY-TO-RUN. w/ Adult Supervision

12v / 24v Diesel Transfer Pump Kit

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

ABSOLUTE EQUIPMENT PTY LTD

ASSEMBLY AND INSTRUCTIONS FRANKE MINERVA 3-IN-1 KETTLE TAP WATER FILTER HOUSING KIT

ORIGINAL INSTRUCTIONS

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

ABSOLUTE EQUIPMENT PTY LTD

Installation & Operating Manual

tyre changer - automatic

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

INDEX RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 6 INSTALLATION USE MAINTENANCE... 33

These installation and maintenance instructions must be read in full and completely understood before the installation!

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

AUTOMATE Li-ion Solar Charging Power Panel

HOME BOX EV CHARGING STATION WITH FIXED CABLE

Transcription:

Installation manual ACO Mains operated drain doser (MODD) for Grease Traps

Installation manual Installation manual - ACO Mains operated drain doser (MODD) for Grease Traps Safety Notes IMPORTANT: Please read the following precautions carefully before using this equipment. This unit contains high voltage circuits that may expose you to the danger of electric shock. Means for disconnection must be incorporated in accordance with the wiring rules. PLEASE DO NOT: open the enclosure without isolating the signal and supply sources. Ensure that these sources have been isolated for at least 5 minutes before entering the enclosu power the unit outside of the values stated on the rating label. use damaged or frayed cables. dismantle or modify this equipment. PLEASE DO NOT: mount the unit to unstable, irregular or non-vertical surfaces. place heavy objects on top of the unit. attempt to place items (such as screwdrivers) into the moving parts of the pump head. discard of the manual, this must be retained. ALWAYS: ensure that care is taken when handling chemicals. NEVER: insert fingers into mechanisms without turning the power supply off first.

ACO This unit must be installed by suitably qualified personnel in accordance with local regulations, or in the absence of local regulations, installed in accordance with the applicable requirements in the National Electrical Code, NFPA 70, Canadian Electrical Code (CEC), Part 1, CSA C22.1, and Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96. This appliance can be used by children age from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard. Before Installation Ensure you have checked all parts required are present and inspect for any damage before installation. In the unlikely event your items are faulty, DO NOT install faulty or damaged parts as this unsafe and will void any warranty. Please return to your distributor in the original delivery condition including any packaging. This unit is ONLY to be installed by a suitably qualified person complying with local regulations.

Installation manual Accessories Peristaltic tubing 5 mm silicone incl. compression fit connectors Ceramic weight and foot filter Pipe Injector Polyethylene 2ubing 3000 mm (2 pcs.) Fixings pack: screws + wall plugs (4 pcs.)

ACO Installation MOUNTING AND CONNECTION: 1 Using the wall plugs and screws specified for this unit, fix the mounting bracket to the wall. There is an embedded spirit level to aid with this part of the installation. 2 3 4 Mount the unit to the wall by hooking it onto the wall bracket. Press down firmly and you will hear a click sound when the unit is secure. Ensure there is no power to the unit, remove the front cover by turning removing the screw anti-clockwise and pulling the front cover towards you as shown. Insert one end of the tube ensuring that it is slotted into the body of the enclosure as shown. IMPORTANT INFORMATION: Silicone grease provided must be applied to the tube and the pump & rotor assembly before the tube is inserted. Failure to apply the grease will affect the pump performance during operation.

Installation manual 5 6 Now by manually rotating the pump head, feed the tube into the unit as shown. IMPORTANT to aid prolonging tube life and efficent running of both mains and battery powered models. Please use the Silicone Grease (supplied) on the outer of the tube. Spread liberally to the outside of the tube to help ease installation, this will also aid continuous smooth operation and help prevent any potential snagging. Now insert the other end of the tube ensuring that it is slotted into the body of the enclosure as shown. IMPORTANT INFORMATION: Supplier accepts no responsibility and/or damages caused to either the product or premises if the installation process is not complied with in full.

ACO Installing the Pipe Injector 1 2 3 Drill a 14 mm hole in the top of your intended waste pipe. For added security it is recommended to use Silicone Sealant (not-supplied) in-between the Pipe Injector and the drilled hole (as shown above). Slowly wind in the Pipe Injector until tight, it is not necessary to over tighten with tools as this may damage the threading on the injector. Now connect the delivery tubing to the Pipe Injector, turning the compression nut clockwise until hand tight. Mains Power Supply (mains version only) Connect Brown and Blue cores of the two core cable to a maximum 240 V AC single phase mains power supply. IMPORTANT INFORMATION: Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. Supply 100-240 V AC BLUE BROWN +

Installation manual Connecting Chemicals 1 Ensure there is no power to the unit; connect the suction tube from the chemical container to (A). Now connect the delivery tube from (B) to the drain or injection point. Flowrate: 100 ml/min (3.38 fl.oz/min) NOTE: Flowrate measured with water and a suction length of 2 metres. A B Programing Modes 1 Set your language by pressing the up or down buttons, and then press the right arrow to confirm your selection (a). Now confirm if you would like to set a PIN (b). If N go straight to Step 3. a b 2 If you selected Y=Yes set a unique 4 digit PIN to enable unwanted access (a). Now confirm the pin entered with Y/N? (If N=No is selected you will need to repeat steps 1&2). a b

ACO 3 Set the day of reference i.e Wed = Wednesday and the current time. 4 (a) Input your first dosing Event by choosing Y=ON, N=OFF using the up and down arrows (please note N will return you to the main menu). Entering the day MTWTSS notice that a dash (-) = no event programed for that day i.e M-W- F-S means no program for Tues, Thurs, Sat. Now set the time for dosing to commence and its duration i.e 01:30 = 1 min 30 secs and press the right button to confirm. The event is now stored (b). Press the right arrow again to repeat this process and store another event. a b TIP: You can check all your entered events by selecting the event number (this will begin to flash), you can now scroll and check through all events entered. Remember that the Y or N next to the event number indicates ON or OFF for each event. Priming the pumps: Hold down the up arrow until the chemical reaches the injection point.

Installation manual Adjusting Date, Time and Password 1 (a) Enter the menu system by holding down the right button. (b) Once in the menu press and hold the left button for 2 seconds. a b 2 (a) (a) Adjust the access code by select Y or N to keep current code (b) Press right to access the time and date settings. Adjust accordingly and press right to get bck to the main menu. a b Useful Information The Drainwatch pump has a maximum run time of 3 minutes per event. The pump cannot be programed to run longer than this per event. 3 min Warranty Your product comes as standard with a 2 year warranty from the date of manufacture, against manufacturing fault or defects and mechanical or electrical breakdown. WEEE Directive Please remember to respect the local regulations: hand in the non-working electrical equipment s to an appropriate waste disposal centre. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.

ACO

ACO. creating the future of drainage www.aco-buildingdrainage.com ACO Mains operated drain doser (MODD) for Grease Traps/JMa/EN/Q2/18