SP PRO Grid Fail - Generator Backup Kit Installation Note

Similar documents
SP PRO ABB Managed AC Coupling

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

SP PRO KACO Managed AC Coupling

mygrid Installation Notes

Connecting Two and Three wire Generator Controllers to the SP PRO

Configuration Diagrams

Instruction Manual for. SP PRO - GO Series Grid Optimised Interactive Inverter Charger. Installation Operation Service

Instruction Manual for SP PRO Interactive Inverter Charger

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

The power to be independent. Grid Independence Outstanding Reliability Ultimate Flexibility

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

Instruction Manual for SP LINK Configuration and Monitoring

TN004 Australian & New Zealand Export Power Control Functionality

SolarEdge. StorEdge Solution Applications. Connection and Configuration Guide. For North America Version 1.0

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

SimpliPhi Power PHI Battery

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

Reverse Power Protection

Generator Start Control Module

SH5K+ Hybrid Inverter Overview & Installation.

Radian Series Inverter/Charger GS7048E. Operator s Manual

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

CZH-LABS Electronics-Salon

Photovoltaics. MPI Hybrid Series

TROJAN BATTERY COMPANY Renewable Energy Warranty Claim Form

Introduction of EzManage Application

Radian Series Inverter/Charger GS8048. Operator s Manual

Relay Driver Applications Guide

SimpliPhi Power PHI Battery

StorEdge Solar and Energy Storage System Review

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

Crop Link Pump Control Wiring

FLEXnet DC Programming & Guidelines

PowerValue 11/31 T kva

PS1 Sinewave Interactive Inverter Charger. User Manual. Document: PC0004 Revision 03

Using Apollo Solar Remote Monitoring Software

Installation Guidance. B-Box Pro2.5~10.0

Lithium Ion Battery Energy Storage for Microgrids

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

SAFE AND RELIABLE POWER FOR MARINE APPLICATIONS MEMBER CERTIFIED. The World Depends on Sensors and Controls

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

Radian Series Inverter/Charger GS4048A GS8048A. Operator s Manual

How To Set Up SimpliPhi Batteries Using OutBack Chargers

Application Engineering Europe

QUICK INSTALLATION GUIDE

The Intelligent Power Selector (IPS) converts any conventional Inverter into a Solar Inverter.

Radian Series Inverter/Charger GS7048E GS3548E. Operator s Manual

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor

SimpliPhi Power PHI Battery INTEGRATION GUIDE: OUTBACK POWER. Power. On Your Terms.

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Using Inverter Input Modes for Smart Grid Management

APS & APS

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

GLM SERIES CONTROL Users Manual Rev:

XW XW XW Hybrid Inverter/Charger. Operation Guide. XW Hybrid Inverter/Charger

SolarEdge. StorEdge Solution Applications. Connection and Configuration Guide. For Europe, APAC & South Africa Version 1.1

:43 1/13 Victron & BYD B-Box

Steca Elektronik SOLARIX PLI

MERCURY TO METAL CONTACTORS AND RELAYS

BYD Battery-Box LV Installation Guidance

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

SMART 1000 / 2000 SERIES

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

TECHNICAL BRIEF Americas

Schneider Electric Conext SW

IMEON 9.12 USER MANUAL

FXR Series Inverter/Charger FXR2012A FXR2524A FXR3048A VFXR2812A VFXR3524A VFXR3648A. Operator s Manual

The system is neat and tidy in its installation, has met the client s requirements and creates an excellent model for other hybrid systems.

Model: ACP-12 AUTO COMPRESSOR PUMP SYSTEM 12 VDC INSTALLATION & OPERATION MANUAL. Phone:

twin engine two battery bank split charge system

Coleman Air Diversion Controller Model C40

RH Series Battery Testers

OpenEVSE. Testing Basic and Advanced

FXR Series Inverter/Charger FXR2012E FXR2024E FXR2348E VFXR2612E VFXR3024E VFXR3048E. Operator s Manual

Goodwe 5048ES with BYD B-BOX (2.5-10) Installation Guide

BYD Battery-Box Pro User Manual Battery-Box Pro 13.8

Lesson 4 Configuring the system. copy right reserved by GoodWe

Installation Guide B-BOX Pro2.5 ~ 10.0

SA Power Networks Commissioning Witnessing Checklist

14 October 09 Vas Kandiah AOQ SSMBB

GENERATOR START CONTROL MODULE

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

182T and T182T Back-Up Alternator System ICA Revision: Date: 17 September 2008

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Smart Hybrid Solar Inverter System

Conext SW Inverter/Charger

SimpliPhi Power PHI Battery

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

Web/SNMP Management Card Event Support Chart

On and Off Grid Interactive Features AC Coupling

Conext XW Inverter/Charger

User Manual. Hybrid PV Inverter. Version: 2.1

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

Transcription:

SP PRO Grid Fail - Generator Backup Kit Installation Note Introduction This installation note details the addition of the Grid fail-generator backup kit to the SP PRO inverter. The kit is only suitable for the small range (SPMC) of SP PRO AU or GO series (Series II) in a single phase or a three phase Advanced Multiphase Solar Hybrid installation. NOTE: Three kits are required for a three phase Advanced Multiphase Solar Hybrid installation. The Grid fail - Generator Backup ONLY operates with Auto Start generators and CANNNOT BE USED with manual start generators. A three phase generator must be used in a three phase installation. When the Grid fail-generator backup kit is installed into the SP PRO, the system allows for the connection of an auto start backup generator that is automatically started and stopped by the SP PRO as required during a grid outage. SP PRO Models Grid fail Generator backup kit, single phase. Grid fail Generator backup kits, three phase. SPMC 240-AU, 004723 SPMC 241-AU, 004724 SPMC 481-AU, 004725 SPMC 482-AU, 004726 SPMC 1201-AU, 004722 1 off SPMCA-GFGB-2448, 005268 No Kit Available 3 off SPMCA-GFGB-2448, 005268 No Kit Available Preparation When installing a single phase system, make sure one Grid Fail Generator Backup kit (005268) is on site. When installing a three phase Advanced Multiphase system, make sure three Grid Fail Generator Backup kits (3 x 005268) are on site. - If installing a three phase system, make sure the AMP Three Phase kit is on site (Order code 005304) This document needs to be read in conjunction with the SP PRO Instruction Manual and SP LINK instruction manual (both found in SP LINK Help menu) Additional information Selectronic web site http://www.selectronic.com.au or contact the Selectronic Sales Team This document applies for SP PRO Series II Rev 21 and above IN0020 Revision 05 004799 1 of 8 POWER PERFORMANCE PASSION

Operation The Grid Fail - Generator Backup (GFGB) functions as follows: 1. When the grid is available and in tolerance the grid is connected via the GFGB contactor to the SP PRO and the SP PRO synchronises to the grid as per normal Solar Hybrid Operation. 2. When the grid fails, or is out of voltage or frequency tolerance (as per the settings in the SP PRO), the SP PRO will disconnect from the grid via the SP PRO AC source contactor. At this stage, the GFGB contactor is keeping the SP PRO attached to the grid supply, and if the grid is restored then the SP PRO will again synchronise to the grid. 3. The SP PRO will continue to power the loads from the battery bank and any connected renewable energy until the grid is restored. 4. If the grid is not restored before a Generator start condition, the SP PRO will automatically start the generator and switch over the GFGB contactor to connect the SP PRO AC source input to the generator supply. The SP PRO will then synchronise to the generator to charge the batteries and power the loads. 5. When the Generator Stop condition is satisfied, the SP PRO stops the generator and continues to run from the battery and any connected renewable energy. This cycle will continue until the grid is restored. 6. When the grid is restored and stable for 60 seconds, the SP PRO will stop the generator (if it is running and has been running longer than the Minimum Runtime in Configuration Settings>AC Source>Generator Controller Settings), disconnect its AC source contactor then switch over the GFGB contactor to return the SP PRO to the grid. The SP PRO will then synchronise to the grid. Note: The GFGB contactor is a break before make changeover contactor. This ensures that the generator supply and grid supply cannot be cross connected. IN0020 Revision 05 004799 2 of 8 POWER PERFORMANCE PASSION

Wiring Overview The following is an overview of the internal and external connections which form part of the Grid Fail Generator Backup Expansion housing. Grid Fail Generator Backup in a Single phase system Note: Diagram is applicable for 24V and 48V SP PRO. Grid Fail Generator Backup in an Advanced Multiphase system IN0020 Revision 05 004799 3 of 8 POWER PERFORMANCE PASSION

SP PRO Installation The SP PRO must be installed as per the installation instructions in the user manual. All wiring is carried out in the SP PRO with the exception of the grid L input and the generator L input wiring. These are wired to the Grid fail-generator backup kit once it is installed. Note: For Advanced Multiphase systems, one Grid fail-generator backup module is installed in each SP PRO. When connecting the AC wiring to the SP PRO, please leave enough space for the Grid fail- Generator backup kit to be installed in the wiring cavity of the SP PRO. Please note the following: 1. Backup loads connect into the AC Load L and N terminals in the SP PRO. 2. Only the L wire from the Grid fail-generator backup connects into the AC Source L terminal within the SP PRO. 3. The Grid L connects to the GRID L terminal on the Grid fail-generator backup kit. The Grid N connects to the AC source N on the SP PRO. 4. The Generator L connects to the GEN L terminal on the Grid fail-generator backup kit. The Generator N connects to the AC source N on the SP PRO. Once the SP PRO has been installed and wired, follow the steps below to install the Grid fail Generator backup kit. IN0020 Revision 05 004799 4 of 8 POWER PERFORMANCE PASSION

Installing the Grid fail-generator backup kit into the SP PRO Referring to the diagram above (page 4), follow the steps below to install the kit. 1. Fit 2 x 5mm mounting screws to the base of the SP PRO inverter at position A. Leave screws loose. 2. Fit Grid fail-generator backup kit to screws as shown. Tighten screws. 3. Wire the connections from the Grid fail-generator backup kit to the SP PRO as shown. NOTE the polarity of the B+ and B- connections 4. Wire the Generator L and Grid L to the GEN L and GRID L terminals respectively on the Grid fail-generator backup kit. 5. Double check all terminals are tight and clamping the wire only and not the insulation. Generator Control Wiring The Generator Run control wiring is wired into the expansion card as shown. This configuration is for a controller that require two wires to be closed to start and run and then opened to stop the generator. In a three phase Advanced Multiphase system the Generator Control Wiring is ONLY connected to the SP PRO on the L1 phase. Note: Refer to Tech Note TN0025 for other control options. SP PRO Configuration Additional Configuration Settings The Site Configuration Wizard is used to configuration the SP PRO with the Grid Fail Generator Backup. Step though the wizard to setup the system to suite the appropriate application. Note: For more information when stuck through the Site Configuration Wizard, right click on the page and a help guide will appear to help setup the system. The settings detailed in Appendix I (pages 7 to 8) will be set when the Site Configuration Wizard is used to configure the SP PRO. Only the settings required to enable Grid Fail Generator Backup are shown. The remainder of systems settings will be set by the Site Configuration Wizard. IN0020 Revision 05 004799 5 of 8 POWER PERFORMANCE PASSION

SP PRO CONFIGURATION AUTOMATIC GENERATOR CONTROL The generator will run upon loss of grid supply on the default settings based on low battery voltage or SoC if enabled. If you wish to enhance this operation, consult SP PRO User manual Generator Automatic Start for full details. Reference Information RL1 - VOLTAGE MONITOR The internal voltage monitor (RL1) is factory set and should not be adjusted. The factory setting is detailed below: : + 15 % : - 8 % : 3 s : DIP-switches under cover 1 ON (DEL-REC) 2 OFF (N.E.) 3 ON (6 s) 4 OFF (INHIBIT) 5 ON (230 VAC) 6 OFF (230 VAC) WARNING: Do not open the DIP-switches cover if the Power Supply is ON. IN0020 Revision 05 004799 6 of 8 POWER PERFORMANCE PASSION

Appendix I: SP LINK Configuration Check AC SOURCE AC INPUT Check the Alternative Source is set to accommodate the different power limit and voltage/frequency range that the SP PRO will accept when the backup generator is running. The Primary Source settings are shown by way of comparison between grid and backup generator. Alternate AC Source Power maximum power SP PRO will draw from backup generator Min, Max AC Voltage allowable voltage range from generator Min, Max AC Frequency allowable frequency range from generator Note: Default Values shown - Adjust values to suit the backup generator. External CT and Extern. Contactor/CT settings are not used in this configuration. AC SOURCE GENERATOR CONTROLLER SETTINGS Generator Controller: Enabled Note: Remaining settings can be adjusted based on specific backup generator requirements. See SP PRO User Manual Generator Controller Settings for further details. IN0020 Revision 05 004799 7 of 8 POWER PERFORMANCE PASSION

INPUTS / OUTPUTS Make sure the SP PRO is configured to control the correct inputs and outputs to monitor and switch between the grid and backup generator. Digital Inputs Normal/Alternate AC Input Power Selector: Follow Backup Select Inhibit Export Input: Follow Backup Select Note: Low Batt Shut Down Override Input setting is not used in this configuration. Grid Fail Generator Backup Grid Fail Backup: Enabled Grid Available Input: Digital Control Input 4 Backup Select Output: Relay Output 3 Generator Outputs Generator Run Output Relay Output 1 The actual generator output type used will depend on what signal is required by the backup generator to start and stop. Refer to generator documentation for details. Note: Default settings shown. Start Output is not used in this configuration. IN0020 Revision 05 004799 8 of 8 POWER PERFORMANCE PASSION